CUSTOMER: M/s ISGEC John Thompson End Customer: M/s Addax Bioenergy, Sierra Leone (SL) Ltd., Africa ALTERNATOR DATA SHEET R D H Issued: RVP Page Doc No : 1CYJ476632A712D e C G Checked SD v B F Released BD n A Customer Comments E Date 01.07.2011 REV-0 Rev Sl No. Description Technical Detail Vender Data Quantity Make Remarks 1 Rated Apparent Output 40000 kVA 1 TDPS 2 Rated Active out put 32000 kW 3 Rated current 2099 A 4 Synchronous speed 1500 rpm 5 Power factor 0.8 lag 6 Duty - Continuous OK 7 Voltage 11kV + 10% 8 Frequency 50Hz + 5% 9 Combine Variation Voltage & Freq. - + 10% 10 Excitation type - Brushless OK 11 Excitation system response time <25 ms 12 Excitation system with PMG. OK 13 Type of rotor - Cylindrical OK 14 Type of coupling - Flanged End OK Rotor -F OK Stator -F OK 15 Class of insulation Exciter armature -F OK Exciter field -F OK PMG stator -F OK Alternator with PMG Rotor -B OK Stator -B OK 16 Temperature rise Exciter armature -B OK Exciter field -B OK PMG stator -B OK Star point design 17 NGR Earthing (RESISTIVELY EARTHED) - Direction of rotation 18 CW from DE (Looking from Drive END) : 19 Type of driving machinery - Steam turbine OK Generator - IP 54 OK 20 Degree of protection Exciter - IP 54 OK PMG stator - IP54 NA 21 Colour shade - RAL 7032 OK 22 Coat thickness - 125 microns OK 23 Installation - Indoor OK 24 Design Ambient Temp. - 50 DegC OK 26 Altitude Above sea level - 1000MSL OK Air inlet temperature - 42 degC 27 Air outlet temperature 56 degC 28 Method of cooling - CACW OK
29 Atmosphere - Non Hazardous OK
Page 2 of 3
PROJECT: IJT Ac Addax Bioenergy Ltd – 1x32MW
CUSTOMER: M/s ISGEC John Thompson End Customer: M/s Addax Bioenergy, Sierra Leone (SL) Ltd., Africa ALTERNATOR DATA SHEET R D H Issued: RVP Page Doc No : 1CYJ476632A712D e C G Checked SD v B F Released BD n A Customer Comments E Date 01.07.2011 REV-0 Rev Sl No. Description Technical Detail Vender Data Quantity Make Remarks 30 Cooling System Cooling water Inlet Temperature: 32 Deg C 31 Cooler Location : TOP No. of Coolers - 4 x 33% cooler sections 32 Required cooling water flow - 3500 LPM 33 Temperature rise of cooling water (Max. temp rise) 6 degC Cooling water recommended Pr. At the inlet 1 to 2 kg/cm2 34 Pressure Drop cooling water - 1 kg/cm2 35 Fouling factor (Cleanliness Factor 85% req.) - 0.0002 m2/kcal/hr/deg.C Cooling water type - Clear untreated water 36 Type of bearing: Sleeve 37 Required Oil Flow to Bearing (LPM) - 60 LPM Required Oil Pressure - 1 to 2 kg/cm2 38 Type of Oil- ISO VG 46 OK Generator - 400V, 3-ph, 50/60Hz, 4Nos.x1kW OK 39 Space heater Exciter - 220V, 1-ph, 50/60Hz, 1No.x200W OK For winding temperature 5 per phase - 15 nos duplex OK Core teeth temperature - 6 nos. duplex OK For bearing temperature(for each bearing) - 01 No(Duplex) OK 40 RTD (Pt100/6Wire/Duplex) Hot air Temperature - 02 Nos(Duplex) OK Cold AirTemperature - 02 Nos (Duplex) OK Exciter Field RTD - 02 Nos OK For hot air outlet temperature - 2 Nos OK 41 Local Temperature gauges without contacts For cold air temperature - 2Nos OK For Each Bearing - 1 No. OK 42 Leak/moisture detector Leakage Detector device - 1 No per tray OK (Total 2 no.s of WLD provided) Moisture detector - 2 nos. OK 43 Short circuit ratio 0.61 Effective winding capacitance to earth 44 (a) Per Phase (Micro Farad) 0.258 Micro Farad (b) All phase connected together (Micro Farad) 0.774 Micro Farad 45 Surge Impedance - Ohm /Phase 46.9 ohm 46 Synchronous impedance - Ohm 4.92 ohm 47 Maximum permissible cap. Loading (MVAR) 20.6 MVAR 48 Maximum permissible ind. Loading (MVAR) 30.9 MVAR 49 Stator Wdg. Test voltage - kV / Min 23 kV for 1 min 50 Field Wdg. Test voltage - kV / Min 1.5 kV for 1 min 51 Maximum Over speed - 1800 rpm for 2 min 52 Critical speed First Lateral Critical speed > 2160 RPM 53 Rotor Inertia GD2 - kg-m2 12,216 54 Rotor Inertia WK2 - 3,054 55 Minimum Barring speed 15 RPM Total weight of rotor - - 20,500 Total weight of stator - - 42,000 56 Total weight of generator - Total weight of Alternator - 78,000 Heaviest lift - Complete Generator (Without Cooler) Page 3 of 3
PROJECT: IJT Ac Addax Bioenergy Ltd – 1x32MW
CUSTOMER: M/s ISGEC John Thompson End Customer: M/s Addax Bioenergy, Sierra Leone (SL) Ltd., Africa ALTERNATOR DATA SHEET R D H Issued: RVP Page Doc No : 1CYJ476632A712D e C G Checked SD v B F Released BD n A Customer Comments E Date 01.07.2011 REV-0 Rev Sl No. Description Technical Detail Vender Data Quantity Make Remarks BASE MVA / Base kV 40 MVA / 11 kV Xd unsat/sat ( P.U.) 1.849 / 1.627 Xd' unsat/sat ( P.U.) 0.304 / 0.268 Xd" unsat/sat ( P.U.) 0.18 Reactance - 1.814 / 1.597 Xq unsat/sat ( P.U.) 57 ( IS / IEC tolerence is applicable for all reactance & resistance value ) Xq' unsat/sat ( P.U.) 1.814 / 1.597 Xq" unsat/sat ( P.U.) 0.374 X0 unsat/sat ( P.U.) 0.157 / 0.138 X2 ( P.U.) 0.28 Armature Leakage Reactance (unsat/sat) ( P.U.) 0.178 / 0.157 Td' (s) 0.789 Time Constant - Td" (s) 0.035 A 58 ( IS / IEC tolerence is applicable for all time Tdo' (s) 4.795 constant value ) 1.011 Tdo" (s) Ta (s) 0.526 59 Armature Resistance (25Deg.C) - ohm/phase 0.0060 60 Armature Resistance (100Deg.C) - ohm/phase 0.0077 61 Field Resistance (25Deg.C) - ohm/phase 0.5656 62 Field Resistance (100Deg.C) - ohm/phase 0.7287 63 Effective Neg. seq. Resistance ohm/phase 0.0142 64 Stator insulation treatment VPI 65 Rotor insulation treatment VPI 110% overload for one hour 66 Overload capability of generator in every 12 hour 67 Nagative sequence capabilities I2 = 15%.I2²t = 20 sec 68 Temp rise in stator ( ETD method) 83 Degree C 69 Temp rise in rotor ( Resistance method ) 88 Degree C 70 Cooler tube material SS 304 100% of rated output with one cooler 71 Redundancy in case of one cooler out of service out of service. Generator withstand capability for three phase line to line , 3 sec 72 line to earth or two line to earth short circuit Excitation (Main Machine) - Excitation System Type - brushless Brushless PMG rating and Voltage - kVA / V 10 / 200 PMG full load current - A 28.8 Exciter Rating - kW 250 Maxi. Field Voltage(EXCITER) - V 147 Min. Field Voltage(EXCITER) - V 12 73 Maxi. Field current(EXCITER) - A 26 Min. field current(EXCITER) - A 2 Voltage at no load (Main Field) - V 144 Voltage at full load (Main Field) - V 399 Current at no load (Main Field) - A 197 Current at full load (Main Field) - A 548 At full load - 97.9 At 3/4 load - 97.8 74 Efficiency at rated PF (%) At 1/2 load - 97.4 At 1/4 load - 95.8