AU_WA_CANNINGTON_WESTFIELD CAROUSEL_EXE_FL01_REV00

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

DETAIL: footer floor layout da loja

CHILLI BEANS SOLAR . WESTFIELD CAROUSEL . CANNINGTON . WA . AU A B

DETAIL OF FINISHING THE CORNS ON THE DETAIL OF FOOTBOARD PLACEMENT


DRYWALL WALLS INTERNAL wall with white acrylic latex finish and wallpaper application (CHILLI BEANS)

NOTE:
SCREW ATTENTION for the placement of the
plinth in the corners in half square · The present project was developed from the survey provided +0,00m
STOCK / SUPPORT
3,60m²

by the franchisor,
neo-rex metal ANGLE or FOOTER FLOOR
similar h=10cm

· For execution of the work on the store it is essential to check all


measures in loco. EXISTING wall

+0,00m P.A.
T1231B
STRUCTURE 52,00m²

PLAN . drywall without footer floor PLAN . drywall with footer floor
no scale no scale A B A B

INTERNAL wall with white acrylic latex finish and wallpaper application 'CHILLI BEANS'

INTERNAL wall with white acrylic latex finish and wallpaper application 'CHILLI BEANS'
DETAIL footer floor DISTRIBUTION DISTRIBUTION
BOARD existing BOARD existing

C C
INTERNAL wall with white acrylic latex finish and wallpaper application (CHILLI BEANS) INTERNAL wall with white acrylic latex finish and wallpaper application (CHILLI BEANS)

· MDF with white formica finish 1 1 LOGO panel projection


MDF with white formica finish 3 3 LINE of bulkhead over existing

NOTE: ATTENTION install the baseboard only on the h=10cm


walls indicated on the renovation plan and after installing +0,00m CASHIER counter +0,00m
PERSPECTIVE STOCK / SUPPORT STOCK / SUPPORT
the furniture. +0,00m P.A.
T1231B
scale 1:25 3,60m² 3,60m² 52,00m²

THE FOOTBOARD IS NOT PART OF THE SCOPE OF


THE FURNITURE SUPPLIER. ACCESSORIES
exhibitor

2 2 +0,00m
MALL

DA
CHA
KIDS FA

exhibitor
ACCESSIBLE service desk module EXISTING wall
EYEWEAR
EXISTING wall
· Metal structure finished in glossy white automotive paint, display
· Joinery with white Formica finish; A B

01 UNIT BOUNDARY WALLS WILL NOT BE BOUNDARY WALLS WILL NOT BE


used to support any elements used to support any elements
(facilities, shelves, etc.) (facilities, shelves, etc.)
mit
E li
OR
ST

EYEWEAR
display MIRROR

+0,00m P.A.
SELF-SUPPORTING auxiliary wall TO
BE CONSTRUCTED for fixing furniture
MIRROR +0,00m P.A.
SELF-SUPPORTING auxiliary wall TO
BE CONSTRUCTED for fixing furniture
reform legend
T1231B T1231B
52,00m²
12.5mm RF gypsum plasterboard with
52,00m²
12.5mm RF gypsum plasterboard with 1 WHITE FORMICA FOOTBOARD h=10cm.
TOP in joinery with white formica
finish
metal structure metal structure
SERVICE table
INTERNAL walls with white acrylic latex finishing SELF-SUPPORTING AUXILIARY CLOSURE IN PLASTERBOARD RF 12.5mm.
and wallpaper application 'chilli beans' 2
2 2 WOODENWORK DOOR WITH WHITE FORMICA FINISH AND APPLICATION OF 'CHILLI BEANS' WALLPAPER
SERVICE TABLE . upper view
scale 1:20 3 (BY CIVIL WORK)
EYEWEAR
display
EYEWEAR
display

INTERNAL wall with white acrylic latex finish and wallpaper application 'CHILLI BEANS'

INTERNAL wall with white acrylic latex finish and wallpaper application 'CHILLI BEANS'

INTERNAL wall with white acrylic latex finish and wallpaper application 'CHILLI BEANS'

INTERNAL wall with white acrylic latex finish and wallpaper application 'CHILLI BEANS'
TOP in joinery with white formica NOTE:
finish
BOUNDARY WALLS WILL NOT BE BOUNDARY WALLS WILL NOT BE
used to support any elements used to support any elements THIS ARCHITECTURAL PROJECT, REGARDING THE NEW OPERATION OF CHILLI BEANS, CONTEMPLATES THE PRESERVATION OF THE
STRUCTURE in 2x2cm metallic
(facilities, shelves, etc.) (facilities, shelves, etc.)
profile with a gloss white automotive
EXISTING FACILITIES AND INFRASTRUCTURES:
paint finish

MIRROR · FIRE FIGHTING PREVENTION AND PROTECTION PLAN (PPCI),


· CLIMATIZATION;
SELF-SUPPORTING auxiliary wall TO SELF-SUPPORTING auxiliary wall TO · STRUCTURAL, INCLUDING A PORCH TO SUPPORT THE FACADE AND METALLIC CURTAIN;
BE CONSTRUCTED for fixing furniture BE CONSTRUCTED for fixing furniture
· ELECTRICAL / DATA AND VOICE, WITH ADEQUACY REGARDING LIGHTING AND ELECTRICAL POINTS / DATA AND VOICE
12.5mm RF gypsum plasterboard with 12.5mm RF gypsum plasterboard with EYEWEAR ACCORDING TO THE NEW LAYOUT PROPOSED AND INDICATED ON THE LIGHTING PLANS AND POWER POINTS.
SERVICE table
metal structure metal structure display
SERVICE TABLE . front view SERVICE TABLE . side view
scale 1:20 scale 1:20
EYEWEAR
display sealing legend
C C C C · TO MAINTAIN (EXISTING
· TO BE BUILT (ASSIGNEE):
CLOSURES AND BOUNDARIES):
12.5mm RF gypsum board with metal structure
MIRROR MALL masonry
SERVICE CHAIR
02 units 2 2
MALL structure

FEATURED
exhibitor

DRYWALL

EYEWEAR
display NOTES:
LINE of bulkhead over existing LINE of bulkhead over existing
· All dimensions must be confirmed on site,
1 FEATURED table
· All installation points must be checked on site;
· It will be in charge of the shopkeeper the execution of its internal installations of air conditioning;
2 EXISTING store divider
profile
2 EXISTING store divider
profile · Wall and floor coverings are the responsibility of the shopkeeper;
· The shopkeeper must check in loco the internal dimensions of the store and the positions of the facilities provided before issuing his executive
projects;
FACADE with porch in red FACADE with porch in red · The entry positions of the installations provided by the store may change depending on the better distribution of the installations of the ceiling of the
+0,00m P.A. acm (PANTONE 186 C) +0,00m P.A. acm (PANTONE 186 C) same;
T1231B T1231B
· Dolls on pillars to cover plummets are the responsibility of the shopkeeper;
52,00m² 52,00m²
· The shopkeeper must build a drywall wall, parallel to the partition made by the mall, and the bottom plate (next to the floor) must be made of RU
drywall (moisture resistant);
· It is foreseen in the project, a structure on the independent / self-supporting facade supported on the store floor to receive loads from the facade (light
and roll-up door);
· Placement of a "same level" type finishing profile at the junction between floors of different materials;
FEATURED
· There should be no unevenness between the store floor and the mall;
exhibitor
· Provide a support element for the lining (profile "L" - TABICA), separating it from the walls of the store, in order to avoid structural movements that end
up causing cracks in it;
CADEIRA JUNO . TOK&STOK · On drywall/plaster walls, perform an auxiliary structure for fixing the furniture;
· The architectural project must be compatible with all complementary projects;
ID 311546 JUNOCD · Do not fix, support, embed, or embed any element in the store's structures and masonry;
EXISTING sliding door entry EXISTING sliding door entry · The store's boundary walls have an exclusive separation function and cannot be used to support any elements of the facilities such as shelves,
COR: PRETO BRILHANTE 10mm tempered glass 10mm tempered glass showcases, showcases and equipment, and these accessories must be self-supporting;
LOGO projection LOGO projection
h=81cm / L=50,5cm / p=51cm / Peso: 3,7kg ·
·
The store's boundary walls cannot receive built-in installations or serve to fix equipment or structures embedded in the jirau;
Ensure that there are no sharp corners in the furniture;
FIXED to the facade portico FIXED to the facade portico · As per specification, all the lighting in the store will be in LED;
· The accessibility service desk must have its exclusive use for priority service, not being allowed to use it as support for objects or exhibition.
*PRODUCT WILL NOT BE SUPPLIED BY
EXISTING showcase structure EXISTING showcase structure
THE FURNITURE EXECUTOR* 2
+0,00m +0,00m
MALL MALL NOTE: THIS ARCHITECTURAL PROJECT DOES NOT INCLUDE COMPLEMENTARY STRUCTURE,
12.5mm RF gypsum plasterboard 12.5mm RF gypsum plasterboard
closure with metal structure closure with metal structure AIR CONDITIONING, ELECTRICAL, SPRINKLER AND SMOKE DETECTION PROJECTS. CONTACT
A A A COMPANY SPECIALIZED FOR SUCH SERVICES.
H AD HAD
C C
FA FA

MODULES (25x25cm) in acm in white MODULES (25x25cm) in acm in white


and red (PANTONE 186 C) and red (PANTONE 186 C)

MODULES must be riveted to each MODULES must be riveted to each


Adress
other and screwed to the structural 2 other and screwed to the structural 1382 . ALBANY HWY . CANNINGTON . WA . 6107 . AUSTRALIA
metal plate metal plate Owner Phone:
E-mail:
Release / Stamp
A B A B

BACKLIGHT in red ACM (PANTONE 186 C) BACKLIGHT in red ACM (PANTONE 186 C)
· acrylic sandwich back film · acrylic sandwich back film
EXISTING store divider
profile
· illuminated with LED profile with
acrylic diffuser
EXISTING store divider
profile
· illuminated with LED profile with
acrylic diffuser MenegazzoDesign
ARQUITETURA
it it
im im
El FACADE with porch in red El FACADE with porch in red
OR OR
ST acm (PANTONE 186 C) ST acm (PANTONE 186 C)
The execution and partial or total reproduction of this project
and/or misuse of the file is prohibited without the express
authorization or knowledge of the author, Gustavo Caligaris
REFORM PLAN . ground floor LAYOUT PLAN . ground floor Menegazzo, under RNP A37163-7. Copyrights reserved by
law nº 9.610 of 02/19/1998.
Technical Manager CAU-SP
scale 1:25 scale 1:25 GUSTAVO C. MENEGAZZO 0000701599
RRT RNP A37163-7
· There will be no anchored elements on the walls or in any elements of the mall, · There will be no anchored elements on the walls or in any elements of the mall,
· There will be no difference in level between the store floor and the mall floor; · There will be no difference in level between the store floor and the mall floor;
· No element of the facade may exceed the limits of the store, except for the sign; · No element of the facade may exceed the limits of the store, except for the sign;
· No element can be fixed to the mall's pedestal profile. · No element can be fixed to the mall's pedestal profile.

00 28.mar.22 INITIAL ISSUE


Review Date Description Verification Approval

Location Store Name Number


WESTFIELD CAROUSEL . T1231B
CANNINGTON . WA . AUSTRALIA Level

Area
Project Title
PROJETO DE ARQUITETURA
REFORM PLAN / LAYOUT PLAN / TYPICAL DETAILS 52,00 m²
Scale Date Page Review Number
INDICATED
Autor do Projeto
MARCH / 2022
CAU-SP ARCH 01/05 00
GUSTAVO C. MENEGAZZO 0000701599 / RNP A37163-7
Adress

RUA PADRE CHICO . 85 . CONJ. 73 . VILA POMPÉIA . SÃO PAULO . SP . BRASIL

Technical Manager CAU-SP Phone: +55 11 3672.5484


GUSTAVO C. MENEGAZZO 0000701599 / RNP A37163-7 E-mail: rodrigo@gustavomenegazzo.com
menegazzo.renata@gmail.com

You might also like