When using the
lipolysis function, it
must be handled by
a professional
physician.
This instrument
does not assume
responsibility for
medical risks! !
-2-
Attention
Respected user:
Thank you for choosing the instruments carefully designed and manufactured by our company. In
◆◆ Please install, use and operate correctly according to the requirements in the manual.
◆◆ Except for authorized personnel of the company, it is strictly forbidden to open the cover and
Safety Precautions
◆◆ The naked eye cannot directly look at the direction in which the laser is thrown.
◆◆ Laser projection can not be aligned with any part of the human body or flammable items.
◆◆ The laser output can be viewed from the side of the phone camera.
◆◆ Operation must be in accordance with the national laser operation level IV to protect.
Due to continuous improvement, update, and replacement of the product, the instrument
you obtained may not be exactly the same as the illustration in the manual. We sincerely
apologize.
-3-
980nm+1470nm lipolysis diode laser
【1】、Product appearance(For reference only, subject to the actual product)
【2】、Part lists:
consumable
【3】、Treatment theory:
The semiconductor laser therapy device uses the 980nm and1470nm wavelength fiber-coupled
laser to treat the needle with a disposable lipolysis fiber, precisely locates excess fat and fat in the
-4-
body, directly hits the target tissue fat cells, and rapidly dissolves and liquefies. The instrument
mainly acts on deep fat and superficial fat, and transfers the energy directly to the fat cells for
uniform heating. During the heating process, the connective tissue and fat cell structure can be
changed by controlling the heat, and the adipose tissue has a photothermal effect (so that the fat is
dissolved). And the photodynamic effect (separating the fat cells from the normal tissue)
decomposes the fat cells to make them evenly liquefied, and the fat liquid is excreted through the
ultra-fine positioning needle, which fundamentally reduces the number of fat cells, effectively
【4】、Treatment scope
1) Accurately remove stubborn fat from the abdomen, arms, buttocks, thighs, etc.
2) It can also be refined and dissolved in parts that cannot be reached by traditional methods
such as jaw and neck.
3) Facial lifting, firming and wrinkle removal.
【5】、Technology Parameters:
-5-
⑥
○
3
○
2
○
4 ⑨ ⑧ ⑦
○
1 ○
5
Structure: ①power button ②Touch screen ③Emergency stop button ④Foot switch
⑤Laser output port ⑥Lipolysis fiber ⑦Power outlet ⑧Foot switch outlet
⑨Ice compress hammer outlet(Please purchase separately if needed.)
Install power line to ⑦ power outlet, install foot switch to ⑧ foot switch outlet
-6-
Figure 8 Lipolysis fiber port;
Optical fiber output port of the
Figure 7 Installed Lipolysis Figure 9 Connect the fiber head to
instrument;
fiber fiber handle; the fiber output port and tighten
Gently unscrew the respective
protective cap;
【Pay attention】
A. After use, be sure to install a protective sleeve on the fiber output port to
prevent dust and contamination of the laser.
B. Laser lipolysis must be performed under the operation of a professional
physician.
C. When replacing the optical fiber, be sure to tighten it, but do not use too
much force. Do not touch the optical fiber input port and optical fiber output
port with your hands! So as not to get into the dust.
【8】、Touch screen:
Home Page
-7-
Power adjust
button djust
Brightness
adjust
Pulse mode
Pulse
adjust Ready
Frequency Start
adjust
Continuous mode
Number of shots Number of shots
from this boots from factory
【9】、Operate guide:
After power-on, do not look directly at the hand piece plug with the naked eye, the 980nm and 1470nm
output light is invisible! However, the damage caused by the laser to the eyes is irreversible and can
●Setup aiming:Click the adjust lamp, the aiming lamp in screen will on, there are three brightness,
●Setup power:Click the energy adjustment button + or - energy value. The 980 nm laser
●Setup Pulse: Click the pulse width adjustment button + or - pulse width value.
The highest value is 60 ms.
●Current times: Display value The number of lasers emitted after this power-on.
-8-
It is automatically cleared after shutdown.
●Total times: The displayed value is the total number of lasers emitted by the machine
and will not be cleared after shutdown. If you need to clear, you can press and hold the display value.
(5)After the setting is completed, click the button and step on the foot switch to start working.
To pause or adjust the parameters, press the button to stop working and enter standby mode.
【10】、Instrument maintenance and care
(1)The optical fiber is easily broken. It is forbidden to bend less than the minimum radius of the bend
when laying. It is forbidden to pile up pressure on the optical fiber. It is forbidden to step on the foot.
The optical fiber is lightly handled when laying. It is forbidden to pull hard.
(2)This instrument is strictly prohibited to be dismantled. Please contact us if there is any trouble.
(3)In order to ensure the normal use of the instrument, purchase or replacement of the spare parts of
【 Attention 】 The customer only needs to carry out daily cleaning and maintenance of the
instrument or the simple fault elimination under the guidance of our company's engineering
personnel. Other maintenance work should be performed by the company's technical staff.
【 warning 】 Before you maintain this instrument, you must turn off the power and dial out the
-9-
【Pay attention】
A. Be sure to connect the fiber optic handpiece before
turning it on! Never have a laser output when there is a fiber
cap on the main unit! After use, be sure to install a protective
sleeve on the fiber output port to prevent dust and
contamination of the laser.
B. Laser lipolysis must be carried out under the supervision
of a professional physician.
- 11 -