7 102 21.0 742
8 116 19.8 699
ZA-150 10 145 17.4 614 150 110 DN65 2200 2500*1500*1850
12 174 15.8 558
7 102 25.2 890
8 116 24.0 848
ZA-180 10 21.1 745 175 132 DN65 2300 2500*1500*1850
145
12 174 18.3 646
7 102 28.7 1014
8 116 27.6 975
ZA-220 10 145 24.6 869 220 160 DN80 3900 2800*1800*1900
12 174 21.5 759
7 102 32.0 1130
8 116 30.4 1074
ZA-250 145 971 250 185 DN80 4200 2800*1800*1900
10 27.5
12 174 24.8 876
7 102 36.7 1296
8 116 34.7 1226
ZA-300 300 220 DN100 4600 3300*1900*1950
10 145 30.2 1067
12 174 27.8 982
7 102 42.0 1484
Star delta startup currents Startup current peak for ZA-350 8 116 40.5 1431
350 250 DN100 5000 3300*1900*1950
10 145 38.1 1346
a DOL system 12 174 34.5 1219
WHY DO YOU CHOOSE
VARIABLE SPEED COMPRESSOR?
40%
Energy-saving
Using VSD screw air compressor can help save huge power fee. ZAKF PM Variable Speed Compressor
Variable Speed Compressor running 3years , the operation energy
savings charges will higher than the purchase new compressor.
Running for 8,000 hours a year, with an average load of 70%, 100
the direct power saving results are:
Efficiency %
90
80
IE4
Save electricity cost US$ US$ US$ US$ US$ US$ US$ US$
(one year us$ ) 2800.00 4085.00 6900.00 10242.00 13970.00 16700.00 20500.00 46570.00 70 IE3
IE2
IE1
60
50
0.12 0.37 0.75 1.5 3 7.5 15 37 90 160 400 1600
Output kW
ZAY PM VARIABLE
SPEED COMPRESSOR FIRST-CLASS OVERALL SOLUTION
The use of large brand contactors can ZAKF frequency converter stepless
meet the control needs of high-voltage speed regulation, the regulator
circuits, with good anti vibration through the internal controller or pid
performance, ensuring stable and converter, can gentle start to use, since
reliable operation in mechanical start the inverter itself has a soft-start
stop and other situations. It can work function, the starting current is at most
normally in high-temperature environ- 1.2 times of the rated current, mitigat-
ments and meet various harsh industri- ing the impact on the power grid and
al application scenarios. energy saving
Professional design
intake valve
Stable
Small pressure loss
High efficiency oil filter
Higher efficiency
High efficiency motor Long life
IP54 protection level Easy to replace
Efficient and stable
ZAKF PM VARIABLE SPEED COMPRESSOR TECHNICAL PARAMETER ZAKF TWO STAGE COMPRESSOR TECHNICAL PARAMETER
Model KW HP Mpa Air Flow Noise Air Tank Lubricant Drive Start Dimension Power Outlet
CBM/MIN dB(A) Volume Method Method size
8Bar ZAKF Screw Compressor
Built-in Dryer with Tank
ZAI-7.5 5.5 7.5 0.5 60 150L 12 Belt
1450*700 G1/2
Drive
*1334.5
Combined compressor,dryer,line filter
and air tank in one shape. ZAI-10 7.5 10 0.8 1.1 230L Y-△ 380/3/50
Conversion
Frequency
380V/60HZ
ZAIV-10 7.5 10 0.8 1.1 230L 220V/60HZ
Direct 380V/50HZ
ZAIV-15 11 15 1.6 62 18 1450*750 G3/4
300L Drive
*1500
ZAIV-20 15 20 2.2
TECHNICAL PARAMETER
Max
Air Flow Filtration
Model KW HP Mpa Noise residual
oil
Dew
Dimension Weight
CFM accuracy Point
dB(A) content (L*W*H) (kg)
m³/min (ppm) (μm) (°C)
ZAH-15A 11 15 1.1
1500*760*1205 650
1500*880*1360 850
ZAH-30A 22 30 2.3
Above tech date are based on ISO1217 Standard,suction temp is about 20'℃,
Relative humidity is 60%,suction pressure is 0.1Mpa.
Product Feature
Air pressure dew point reaches 5℃ Atomospheric
Design Criterion: dew point reaches -17℃-23℃
Power consumption:30%less than same types
Operating Pressure:design criterion-0.7Mpa from other factories
(0.4Mpa min,1.0Mpa max)
Service Condition
Air Inset Temperature:<45℃ Environmental Operating Pressure:design criterion-0.7Mpa
Requirements (0.4 Mpa min,1.0Mpamaxi
Air Inset Temperature:Eshaust temperature
Temperature:<38℃,if>38℃,air convection of air compressor<45℃
device needed Operating Pressure:design criterion-0.7Mpa
(0.4Mpa min,1.0Mpa max)
Installed Environment:good ventilation, Air Inset Temperature:<45℃ Environmental
no dust andflying catkins Requirements
Temperature:<38℃,if>38℃,air convection
device needed
Installed Environment:good ventilation,
no dust andflying catkins
Standard Standard
Capacity Voltage Power Current Refrigeration Caliber of Tube Weight Dimension Capacity Voltage Power Current Refrigeration Caliber of Tube Weight Dimension
m³/MIN AC KW A Type (in and out) KG L*W*H m³/MIN AC KW A Type (in and out) KG L*W*H
Model Model
AC-10 1.5 0.37 3.90 1”PT 60 700*450*730 ND-100 13 2.25 5.5 240 1200*600*1140
1/2PT
AC-20 2.5 0.37 3.90 70 700*450*780 ND-150 18 3.0 7.50 330 1300*700*1220
1Φ220V
AC-30 3.8 0.74 4.00 1 1/2”PT 90 950*500*840 ND-200 23 3.75 7.80 400 1350*700*1440
50HZ 3/4PT
AC-50 7.0 1.09 6.70 120 1030*500*890 ND-250 28 6.0 10.80 450 1500*800*1640
R22 R22
AC-75 10.0 1.58 8.80 160 1200*600*1140 ND-300 36 6.8 12.4 500 1650*900*1650
R134A 2”PT R134A 1-1/4PT
AC-100 13.0 1.94 10.70 200 1300*700*1220 ND-400 45 3Φ380V 7.5 15.4 650 1650*900*1650
R407C R407C
50HZ 1-1/2PT
AC-150 18.0 2.57 7.50 230 1350*700*1440 ND-500 55 9.0 19 850 1640*1070*2010
R404A R404A
AC-300 36 50HZ 5.78 13 DN100 330 1500*800*1640 ND-1000 110 22.5 35 1700 2200*1250*2170
TECHNICAL PARAMETER
TECHNICAL PARAMETER
Standard
Capacity Connecting Pipe of Dimension Weight
Standard Model m³/MIN Inlet and Outlet air L*W*H KG
Capacity Heater Connecting Pipe of Dimension Weight
m³/MIN Power Inlet and Outlet air L*W*H KG YX-10 1.5 Rc1 560*650*1200 60
Model
YX-20 2.5 Rc1 560*650*1400 80
YW-013 13 6.0 PN1.0DN50 800*1000*2300 420
YX-30 3.8 Rc1 710*650*1830 150
YW-100 100 15.0 PN1.0DN125 2860*1390*3464 5286 YX-700 80 PN1.0DN125 2700*1290*3414 4584
Remark:Specifications are subject to change,please refer to actual products Remark:Specifications are subject to change,please refer to actual products
AIR STORAGE AF Compressed
Line Filter
TANK
TECHNICAL PARAMETER
Specification Design Temperature Tank Height Tank dia Inlet Outlet Base
SR# Connector
Volume/Pressure °C H1 Φ H2 DN RP H3 DN RP Φ1 d
1 0.3/0.8 1558 634 1204
2 0.3/1.0 1590 635 1205
150 500 25 Pp1” 25 Pp1” 360 20 R3/4”
3 0.3/1.25 1592 636 1206
14 1.0/1.0 150 2092 800 711 40 Pp11/2” 1811 40 Pp11/2” 560 24 R3/4”
15 1.0/1.25 2096 713 1813
17 1.5/1.0 150 2275 1000 763 80 Pp2” 1793 80 Pp2” 700 24 R3/4”
18 1.5/1.25 2279 764 1794
29 4.0/1.0 150 2904 1400 956 100 2207 100 1050 30 R1”
30 4.0/1.25 2908 959 2209 AF015 G3/4 or 1’’ 1.5 1 1.1 270 240 85
31 5.0/0.8 3752 930 3130
32 5.0/1.0 150 3754 1400 932 100 3132 100 1050 30 R1” AF024 G1 1/2’’ 2.4 1 2.2 360 326 110
33 5.0/1.25 3756 933 3133
38 8.0/1.0 150 4556 1600 984 125 3834 125 1200 30 R1”
39 8.0/1.25 4560 985 3835
AF090 G2 1/2’’ 9 1 10 535 485 150
40 10.0/0.8 3766 1083 2933
41 10.0/1.0 150 3768 2000 1084 150 2934 150 1500 30 R1” AF 120 G2 1/2’’ 12 1 13 950 900 150
42 10.0/1.25 3774 1087 2937
47 15.0/1.0 150 4640 2200 1200 150 3700 150 1650 30 R1”
48 15.0/1.25 4648 1202 3702
AF 240 DN80 24 2 pc 120 75 1495 1190 344
49 20.0/0.8 5238 1299 4199
50 20.0/1.0 150 5244 2400 1302 150 4202 150 1800 30 R1” AF 300 DN100 30 2 pcs 150 85 1650 1350 344
51 20.0/1.25 5248 1304 4204
52 25.0/0.8 6250 1375 5095 AF 360 DN100 36 3 pcs 120 120 1495 1190 398
53 25.0/1.0 150 6256 2400 1378 200 5098 200 1800 30 R1”
54 25.0/1.25 6260 1380 4100
AF 450 DN125 45 3 pcs 150 130 1650 1345 398
55 30.0/0.8 6829 1305 5865
56 30.0/1.0 150 6835 2500 1318 200 5868 200 1900 30 R1”
AF 600 DN125 60 4 pcs 150 160 1810 1311 520
57 30.0/1.25 6839 1320 5870