PROJECT : 3-STOREY DORMITORY PAGE :

CLIENT : JEROME UY DESIGN BY : B A BAUN


JOB NO. : DATE : REVIEW BY :
Steel Beam Design for WF16x77(maximum)

INPUT DATA & DESIGN SUMMARY


BEAM SECTION (WF, Tube or WT) => W16X77 WT Ix Sx J bf tf tw
49 7.77 1.10 7.12 0.72 0.43
SLOPED DEAD LOADS wDL,1 = 1.42 kips / ft
wDL,2 = kips / ft
PROJECTED LIVE LOADS wLL,1 = 0.84 kips / ft
wLL,2 = kips / ft
CONCENTRATED LOADS PDL = kips
PLL = kips
BEAM SPAN LENGTH L1 = 19.68 ft
CANTILEVER LENGTH L2 = ft, (0 for no cantilever)
0 : 12 (θ=
0
BEAM SLOPE 0.00 )
DEFLECTION LIMIT OF LIVE LOAD LL = L / 240

BEAM YIELD STRESS Fy = 36 ksi

THE BEAM DESIGN IS ADEQUATE.

ANALYSIS
DETERMINE REACTIONS, MOMENTS & SHEARS

 w DL ,1  w  
R 2  0.5   w LL ,1  L1   DL ,2  w LL ,2   L1  0.5 L 2  L 2  P L1 L 2
 cos    cos   L1 L1
= 3.60 kips

 w DL ,1   w 
R1    w LL ,1  L1   DL ,2  w LL ,2  L 2  P  R 2
 cos    cos  
= 3.60 kips

X1 = 10.00 ft
X2 = 10.00 ft
X3 = 0.00 ft

 w DL ,2 
M Min  0.5   w LL ,2  L 22  P L 2  0.0 ft-kips
 cos   

  X 1 X 2 
2
 w DL ,1
M Max    w LL ,1   18.0 ft-kips
 cos   8

V max = 3.60 kips, at R1 right.

CHECK MMin BENDING CAPACITY ABOUT MAJOR AXIS (AISC 360-05 Chapter F)

l  Max  L 2 , X 3   0.00 ft, unbraced length

Chapter F Sections for WF Tube WT


Required Conditions F2 F3 F4 F5 F7 F9 M allowable = M n / b =
Double Symmetric x x x 19.4 ft-kips
Compact Web x x
x
> M Min [Satisfactory]
Noncompact Web
x
Slender Web where
Compact Flanges x b = 1.67 , (AISC 360-05 F1)
Noncompact Flanges x
Slender Flanges
Applicable Section ok

CHECK MMax BENDING CAPACITY ABOUT MAJOR AXIS (AISC 360-05 Chapter F)
M allowable = M n / b = 19.4 ft-kips, top flange fully supported
> M Max [Satisfactory]