Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

ProSpector 2 ProSpector 2 LE ProSpector 3 Basic ProSpector 3 Advace ProSpector 3 Max

Image of the Instrument

X-Ray Tube W, 40 kV Rh (W, Ag), 40 kV Rh, 40 kV (Option 50 Kv) Rh, 40 kV (Option 50 Kv) Rh, 50 kV (Option 50 Kv)

Primary Filter Single Automatic 4 Position Changer Single Automatic 8 - Position Changer Automatic 8 - Position Changer

Collimators Single Single Single Automatic 2 - Position Changer Automatic 2 - Position Changer

Extra large area Fast SDD with


X-Ray Detector Si-PIN-Diode Large Area SDD SDD (Option - Large Area Fast SDD) Large Area Fast SDD
graphene window

Detector Window - - Be, 12 um Be, 8 um Grafene, 1 um

Detection Range Cl-U Mg-U S-U Mg-U Mg-U (Na-U)

CCD Camera No Simple view (Option) Sample View (Option) Simple Vie (Option - Macro view) Simple View, Macro view

Temperature Correction Yes Yes Yes Yes Yes

Barometric Correction No Yes No Yes Yes

Bluethoot Option Option Option Option Yes

Wi-Fi No Option Option Option Yes

GPS No No No Option Yes

Ingress Protection IP54 IP54 IP65 IP65 IP66

He Purge No No No No Option
Range Analysis of ProSpector 2

: elements that can be analyzed by ProSpector 2

H : elements that cannot be analyzed by ProSpector 2 He

Li Be B C N O F Ne

Na Mg Al Si P S Cl Ar

K Ca Sc Ti V Cr Mn Fe Co Ni Cu Zn Ga Ge As Se Br Kr

Rb Sr Y Zr Nb Mo Tc Ru Rh Pd Ag Cd In Sn Sb Te I Xe

Cs Ba * Hf Ta W Re Os Ir Pt Au Hg Tl Pb Bi Po At Rn

Fr Ra ** Rf Db Sg Bh Hs Mt Ds Rg Cn Nh Fl Mc Lv Ts Og

* La Ce Pr Nd Pm Sm Eu Gd Tb Dy Ho Er Tm Yb Lu

** Ac Th Pa U Np Pu Am Cm Bk Cf Es Fm Md No Lr
Range Analysis of ProSpector 2 LE

: elements that can be analyzed by ProSpector 2 LE

H : elements that cannot be analyzed by ProSpector 2 LE He

Li Be B C N O F Ne

Na Mg Al Si P S Cl Ar

K Ca Sc Ti V Cr Mn Fe Co Ni Cu Zn Ga Ge As Se Br Kr

Rb Sr Y Zr Nb Mo Tc Ru Rh Pd Ag Cd In Sn Sb Te I Xe

Cs Ba * Hf Ta W Re Os Ir Pt Au Hg Tl Pb Bi Po At Rn

Fr Ra ** Rf Db Sg Bh Hs Mt Ds Rg Cn Nh Fl Mc Lv Ts Og

* La Ce Pr Nd Pm Sm Eu Gd Tb Dy Ho Er Tm Yb Lu

** Ac Th Pa U Np Pu Am Cm Bk Cf Es Fm Md No Lr
Range Analysis of ProSpector 3 Basic

: elements that can be analyzed by ProSpector 3 Basic

H : elements that cannot be analyzed by ProSpector 3 Basic He

Li Be B C N O F Ne

Na Mg Al Si P S Cl Ar

K Ca Sc Ti V Cr Mn Fe Co Ni Cu Zn Ga Ge As Se Br Kr

Rb Sr Y Zr Nb Mo Tc Ru Rh Pd Ag Cd In Sn Sb Te I Xe

Cs Ba * Hf Ta W Re Os Ir Pt Au Hg Tl Pb Bi Po At Rn

Fr Ra ** Rf Db Sg Bh Hs Mt Ds Rg Cn Nh Fl Mc Lv Ts Og

* La Ce Pr Nd Pm Sm Eu Gd Tb Dy Ho Er Tm Yb Lu

** Ac Th Pa U Np Pu Am Cm Bk Cf Es Fm Md No Lr
Range Analysis of ProSpector 3 Advance

: elements that can be analyzed by ProSpector 3 Advance

H : elements that cannot be analyzed by ProSpector 3 Advance He

Li Be B C N O F Ne

Na Mg Al Si P S Cl Ar

K Ca Sc Ti V Cr Mn Fe Co Ni Cu Zn Ga Ge As Se Br Kr

Rb Sr Y Zr Nb Mo Tc Ru Rh Pd Ag Cd In Sn Sb Te I Xe

Cs Ba * Hf Ta W Re Os Ir Pt Au Hg Tl Pb Bi Po At Rn

Fr Ra ** Rf Db Sg Bh Hs Mt Ds Rg Cn Nh Fl Mc Lv Ts Og

* La Ce Pr Nd Pm Sm Eu Gd Tb Dy Ho Er Tm Yb Lu

** Ac Th Pa U Np Pu Am Cm Bk Cf Es Fm Md No Lr
Range Analysis of ProSpector 3 Max

: elements that can be analyzed by ProSpector 3 Max

H : elements that cannot be analyzed by ProSpector 3 Max He

Li Be B C N O F Ne

Na Mg Al Si P S Cl Ar

K Ca Sc Ti V Cr Mn Fe Co Ni Cu Zn Ga Ge As Se Br Kr

Rb Sr Y Zr Nb Mo Tc Ru Rh Pd Ag Cd In Sn Sb Te I Xe

Cs Ba * Hf Ta W Re Os Ir Pt Au Hg Tl Pb Bi Po At Rn

Fr Ra ** Rf Db Sg Bh Hs Mt Ds Rg Cn Nh Fl Mc Lv Ts Og

* La Ce Pr Nd Pm Sm Eu Gd Tb Dy Ho Er Tm Yb Lu

** Ac Th Pa U Np Pu Am Cm Bk Cf Es Fm Md No Lr

You might also like