2000 LPH 40pct Recovery

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Toray Membrane Europe RPI Calculator

Project Information Water Composition


raw feed brine
Project Name 2000 LPH
Calcium Ca 108.22 108.22 180.18 mg/l
Revision Revision #1
Magnesium Mg 66.88 66.88 111.35 mg/l
End Customer
Sodium Na 32.38 32.64 54.35 mg/l
Project Date 2024-06-29
Potassium K 0 0 0 mg/l
Ammonium NH₄ 0 0 0 mg/l
Plant Operation Data
Barium Ba 0 0 0 mg/l
Feed Flow 5 m³/h Strontium Sr 0 0 0 mg/l
Product Flow 2 m³/h Iron Fe 0 0 0 mg/l
Concentrate Flow 3 m³/h Aluminium Al 0 0 0 mg/l
Operation Time 24 h/d Manganese Mn 0 0 0 mg/l
Recovery 40 % Sulfate SO₄ 11.06 11.06 18.41 mg/l
Concentration Factor 1.67 Chloride Cl 324.89 324.89 540.93 mg/l
SDI 3 Fluoride F 2.24 2.24 3.73 mg/l
Rejection 99.8 % Bicarbonate HCO₃ 168 168 279.71 mg/l
Nitrate NO₃ 2.74 2.74 4.56 mg/l
Antiscalant & Dosing Amount Phosphate PO₄ 0 0 0 mg/l

Antiscalant Selection RPI-3000A (Broad Spectrum) Silicate SiO₂ 106.49 106.49 177.3 mg/l

Antiscalant Datasheets https://ropur.com/antiscalants/rpi-3000a Bromide Br 0 0 0 mg/l

Total Feed Dose 14 mg/l Carbon Dioxide CO₂ 0 7.67 7.67 mg/l

24h requirement 1.68 kg Carbonate CO₃ 0 0.41 0.69 mg/l

24h requirement 1.46 l Boron B 0 0 0 mg/l

Daily requ. [at 24 h/d] 1.68 kg


Daily requ. [at 24 h/d] 1.46 l Scaling Ability
Comment <div>"Manual dosage."</div> Ca⁺⁺ Mg⁺⁺ Na⁺ + K⁺
LSSC 64.61 % 24.21 % 11.18 %
pH-Control LSSC indicates the feedwater scaling ability based on its cationic composition.

pH raw water 7.5


pH feed water 7.5 Bio-Fouling Probability
pH brine water 7.7
Feed AOC (0.00 - 100.00 µg/l) 0 µg/l
without
Acid/Alkali Selection Feed Temperature (min 10 °C - max 40 °C) 25 °C
acid/alkali
Feed total Phosphorous (0.00 - 1.00 mg/l) 0 mg/l
Water Classification CFU in plant assumed >0 /mL

raw feed brine Probability of RO Biofouling (within 6 months) 0 %

LSI 0.1 0.1 0.73 Probability of RO Biofouling based on AOC only 6 %

SDSI 0.32 0.32 0.92


Effective Type of Water Brackish
Brackish Well or Softened
Classification
Tapwater

Maximal Salt Saturation in %

Calculation generated on 2024-06-29 05:43:58[GMT] by RPICalcX v2.2.0

You might also like