Professional Documents
Culture Documents
R10-H10C03-CHC-MAT-ST-0002 Rev.00 Material Technical Approval for curing compound
R10-H10C03-CHC-MAT-ST-0002 Rev.00 Material Technical Approval for curing compound
R10-H10C03-CHC-MAT-ST-0002 Rev.00 Material Technical Approval for curing compound
R10-H10C03-CHEAC-MA-0004
Roads and Access Platform Material Technical Approval Internal No
works at Sheybarah south for curing compound
Island Hotel 10 REVISION 00
28-Jun-21
Signature: Date:
Additional Distribution
Revision : 00
PROJECT NAME
PILING, FOUNDATIONS, HAUL ROADS AND
ACCESS PLATFORMS WORKS AT HOTEL 10
CLIENT
THE RED SEA DEVELOPMENT COMPANY
CONTRACTOR
中国港湾工程沙特阿拉伯有限责任公司
CHAINA HARBOR ENGINEERING ARABIA CO LTD.
Piling,Foundations,Haul CHEAC
R10-H10C03-CHEAC-MA-0004
Roads and Access Platform Material Technical Approval Internal No
works at Sheybarah south for curing compound
Island Hotel 10 REVISION 00
TABLE OF CONTENTS
3 BILL OF QUANTITY
☒
Section 1
MATERIAL TECHNICAL APPROVAL SHEET
Date:- 6/7.7 /2021
41 ##..[I:'
l>Mte:
TO: THE RED SEA DEVLOPMENT COMPANY Project Title:- Piling, Foundations, Haul Roads and Access Platforms works at Hotel 10 NO OF KARO COPIES SUBMITTAL CODE
Om Non..lnspectable 00
MATERIAL TECHNICAL APPROVAL FOR CURING COMPOUND
(1] NO
R10.H11C03-<.liEAC·llD-000.9
ITEM NO DESCRIPTION MANUFACnJRER / SUPPLIER CATALOG,SPECIFICATION,DRAWING NO (FOR TRSDC USE ONLY) COMMENTS
1 CURING COMPOUND
1. MFG Name:- HENKEL POLYBIT
INDUSTRIES LTD.
Location:- Saudi Arabia
Project Specification#, Rl0-H11C03-CHEAC-
DD-0009
Project Drawings #. N/A
APPROVED D
APPROVED AS NOTED D
REVISE AND RESUBMIT D
REJECTED D
.
CHEAC REVIEWED & APPROVED BY: TRSDC
SIGNATURE:
\1r-;\-� -� "\"\
NAME: Muhammad Sohail Roheel Bari Naveed Anwar Zhang Jun fUADHASAN
POSITION: Procurement Engineer Procurement Manager QA Manager Associate Project Director SNR.PROJECl' DIRECTOR (TRSDC)
Section 2
PROJECT SPECIFICATION & DRAWINGS
Piling, Foundations, Haul DOCUMENT
R10-H11C03-CHEAC-DD-0009
Roads and Access NUMBER
Design Document-
Platforms works at
Concrete Specification
Ummahat Al Shaykh Island REVISION 00
9-3 Hotel 11
ISSUED BY CHEAC ISSUED DATE 16-Jun-21
TRSDC Ref. No.: R 1 0 - H 1 1 C 0 3 - C H C - S P C - S T - 0 0 0 2
6. Bituminous paint shall be applied to the lips of the loop of copper waterstop and
the loop filled with bituminous compound before embedding in the concrete.
C. Joint Fillers
1. Expansion joint filler shall be pre-formed bitumen bonded cork board 25mm thick
and shall compress to 50% of thickness and shall recover to not less than 70% of
its original thickness.
D. Joint Sealants
2. Expansion joint fillers and primers shall be compatible with and obtained from the
same manufacturer as the adjacent sealant.
E. Grouting Material
2. Alternatively, the Contractor can design the grout consisting of cement mixed
with water in approved proportions. Fine aggregate may be included in approved
quantities. In all cases, a shrinkage compensating additive shall be incorporated
in the material in accordance with manufacturer's recommendations.
3. In all cases care shall be taken to ensure that no pockets of air voids are trapped
in the grouted spaces. Grouting material and method shall be subject to the
approval of the Client’s representative.
A. General
1. The Contractor shall prepare and submit a detailed method statement for wet
curing of concrete and maintaining the curing regime to the standards and times
specified. All necessary supports and coverings shall be provided to form
enclosed conditions to provide shade and support the necessary hessian and
polythene.
3. Surfaces:
b. The curing compound shall be applied immediately after the initial bleed
water evaporates and the concrete has achieved its initial set. In case of de-
shuttering, the concrete surface is wetted with water but not with free
standing water, before the curing compound is applied. The application can
be done by a brush, roller or an airless spray.
1. Concrete shall be protected from contamination by oil, fuel and other deleterious
materials for a minimum period of 30 days after placing.
C. Insulation Formwork
1. Insulating formwork and insulating blankets shall be left in place until the peak
temperature in the concrete has been reached and without causing thermal
distress to the concrete. The period in the formwork will count towards the curing
period.
D. Protection of Joints
1. Rebates formed to receive sealant and the surfaces of construction joints shall
be protected from curing compound by wet hessian to ensure proper curing of
the joint surface and adjacent concrete. The protection shall remain in place until
the joint surface is sealed.
Piling,Foundations,Haul CHEAC
R10-H10C03-CHEAC-MA-0004
Roads and Access Platform Material Technical Approval Internal No
works at Sheybarah south for curing compound
Island Hotel 10 REVISION 00
Section 3
BILL OF QUANTITY
Piling,Foundations,Haul CHEAC
R10-H10C03-CHEAC-MA-0004
Roads and Access Platform Material Technical Approval Internal No
works at Sheybarah south for curing compound
Island Hotel 10 REVISION 00
BILL OF QUANTITY
Sr # Material Description Quantity
1 Curing Compound 10,000 Liters
Piling,Foundations,Haul CHEAC
R10-H10C03-CHEAC-MA-0004
Roads and Access Platform Material Technical Approval Internal No
works at Sheybarah south for curing compound
Island Hotel 10 REVISION 00
Section 4
MANUFACTURER / VENDORTECHNICAL
DATA SHEET
Piling,Foundations,Haul CHEAC
R10-H10C03-CHEAC-MA-0004
Roads and Access Platform Material Technical Approval Internal No
works at Sheybarah south for curing compound
Island Hotel 10 REVISION 00
CHARACTERISTICS
► Dual protection as curing and sealing compound
► Protects concrete from water borne chlorides, sulphates
and atmospheric carbon dioxide
► Economical, Labour saving, Easy to apply
TDS_Polycure AC_GCC_0519
easy to apply reduce surface non toxic
dust
DESCRIPTION
Polycure AC is a non-degradable liquid type of curing and
sealing compound based on acrylic and proper wetting
agents. Polycure AC is used to prevent rapid evaporation
of water from fresh concrete ensuring uniform hydration,
adequate strength development and minimizes plastic and
drying shrinkage cracks. This will also act as sealing coat 1
for protecting concrete from the attack of water borne salts
and ingress of carbon dioxide from the atmosphere. The shuttering, the concrete surface is wetted with water but
cured film further acts as a primer system for subsequent not with free standing water, before the curing compound
surface finishes. It also provides a dust free surface to the is applied. The application can be done by a brush, roller
concrete with a reduced incidence of drying shrinkage or an airless spray at a coverage rate of 5m²/L. For highly
cracks. porous surfaces, a second coat has to be applied at the
FIELDS OF APPLICATION same coverage rate.
A cost effective curing compound as well as surface sealer PRIMER FOR SUBSEQUENT FINISHES
for fresh concrete. An effective alternative to hessian, water Polycure AC acts as a primer and bonding agents for the
or polyethelyne curing aids. following systems:
Polycure AC is suitable for use on all concrete surfaces
– water based emulsion paint systems containing PVA,
and acts as a more effective and economical alternative to
PVC, and acrylic co-polymers
separate curing, priming systems.
– tile adhesives based on the above polymers
– in high rise construction where continous wet curing is
not possible. – bitumen based emulsions or solutions
– in areas subjected to high drying winds which require – cementitious systems
continuous curing. Note:
– surfaces, which requires subsequent finishes. – concrete curing compound will effectively prevent
evaporation of water from concrete, provided it is not
APPLICATION INSTRUCTIONS puctured or damaged, but will not allow the ingress of
Mix the contents of the drum thoroughly prior to the water to replenish that is lost by self desiccation.
application in order to remove the sediments. It is – where water curing is inconvenient or potable water for
recommended that the curing compound is applied curing is not available, sealing fresh concrete surface with
immediately after the initial bleed water evaporates and curing compound is the best alternate curing method.
the concrete has achieved its initial set. In case of de-
STORAGE & SHELF LIFE TECHNICAL SPECIFICATION
Store in a cool, dry place and keep away from all sources PROPERTIES VALUES Test Standards
of heat and sunlight. In tropical climates, store in air Appearance White liquid -
condition rooms. The shelf life is up to 12 months in un- Specific gravity, [g/cc] 1.0±0.05 ASTM D 1475
opened conditions and if stored as per recommendations.
Toxicity Non toxic -
Excessive exposure to sunlight, humidity and UV will result
Applicable standard ASTM C 309
in the deterioration of the quality of the product and reduce
Type 1&2, class A&B
its shelf life. ASTM C 156 -
HEALTH & SAFETY Application temperature, [°C] 5 to 55 -
As with all construction chemical products, caution should All values given are subject to 5-10% tolerance
always be exercised. Protective clothing such as gloves
and goggles should be worn. Treat any splashes to the Apart from the information given here it is also important to observe the relevant
skin or eyes with fresh water immediately. Should any of guidelines and regulations of various organisations and trade associations as
the products be accidentally swallowed, do not induce well as the respective standards. The aforementioned characteristics are based
on practical experience and applied testing. Warranted properties and possible
vomiting, but call for medical assistance immediately. uses which go beyond those warranted in this information sheet require our
written confirmation. All data given was obtained at an ambient and material
SUPPLY temperature of +23°C and 50 % relative air humidity at laboratory conditions
unless specified otherwise. Please note that under other climatic conditions
Polycure AC 20L & 200L drum hardening can be accelerated or delayed.
The information contained herein, particularly recommendations for the
handling and use of our products, is based on our professional experience.
As materials and conditions may vary with each intended application, and
thus are beyond our sphere of influence, we strongly recommend that in each
case sufficient tests are conducted to check the suitability of our products
for their intended use. Legal liability cannot be accepted on the basis of the
TDS_Polycure AC_GCC_0519
contents of this data sheet or any verbal advice given, unless there is a case
of wilful misconduct or gross negligence on our part. This technical data sheet
supersedes all previous editions relevant to this product.
As the quality of the coating is dependent on the substrate and material temperatures, it is recommended to follow the general
working guidelines:
a) Store the materials in a dry and temperature controlled area preferably in the range of +20° C to +25° C.
b) Ensure that the surface temperature where the coating will be applied is kept within the temperature range of +4° C to
+45° C.
c) Application should be done preferably when the day time atmospheric temperatures are considerably low.
d) The equipments should be kept cool so that they do not impart additional temperature to the material when it is being
mixed or applied.
e) Ensure that sufficient material and labour is available at site during application.
Surface Preparation
1) The concrete surface should be fresh and free from bleed water.
2) For freshly de-moulded concrete, dampen the surface properly with clean water prior to the application of the curing
compound.
Application
1. Mix the contents of the drum properly to remove any sediment and also aid the even distribution of wax and pigments.
2. The recommended method of application of the curing compound is by using airless spray equipment which will provide a
continuous and uniform application. Alternatively, the curing compound can be also applied with a good quality lambskin
roller and it will take 5 hours time to fully dry.
3. When using the spray, the nozzle is to be held at about 400 to 500 mm from the concrete surface. Move the nozzle back
and forth to ensure even and complete coverage.
Similarly, when applying by roller, it should be rolled back and forth for a proper application.
5. All tools are to be cleaned immediately after use with cleaning solvents. Hardened materials
can be removed mechanically only.
Note: This is an Acrylic resin based curing compound which penetrates into the concrete surface and seals the pores, thus
preventing the evaporation of the moisture from the concrete. This curing compound will act as a primer for any further
coatings or renders to be applied onto the concrete surface.
HAAD Poison and Drug Information Center UAE, TOLL FREE TEL. NUMBER 800-424
Classification (CLP):
The substance or mixture is not hazardous according to Regulation (EC) No 1272/2008 (CLP).
The substance or mixture is not hazardous according to Regulation (EC) No 1272/2008 (CLP).
For full text of the H - statements and other abbreviations see section 16 "Other information".
Substances without classification may have community workplace exposure limits available.
For full text of the R-Phrases indicated by codes see section 16 'Other Information'.
Substances without classification may have community workplace exposure limits available.
General information:
In case of adverse health effects seek medical advice.
Inhalation:
Move to fresh air, consult doctor if complaint persists.
Skin contact:
Rinse with running water and soap. Skin care. Remove contaminated clothes immediately.
Eye contact:
Rinse immediately with plenty of running water, seek medical advice if necessary.
Ingestion:
Rinse mouth and throat. Drink 1-2 glasses of water. Seek medical advice.
4.2. Most important symptoms and effects, both acute and delayed
No data available.
4.3. Indication of any immediate medical attention and special treatment needed
See section: Description of first aid measures
Hygiene measures:
Wash hands before work breaks and after finishing work.
Do not eat, drink or smoke while working.
Valid for
Ver.Arab.Emir.
None
MSDS-No.: 557934 POLYCURE AC Page 4 of 9
V001.0
Valid for
Bharain
None
Valid for
Egypt
None
Valid for
Jordan
None
Valid for
Kuwait
None
Valid for
Israel
None
Valid for
Kenya
None
Respiratory protection:
Ensure adequate ventilation.
Hand protection:
Recommended are gloves made from Nitril rubber ( Material thickness >0,1 mm, Perforation time < 30s).Gloves should be
replaced after each short time contact or contamination. Available at laboratory specialized trade or at pharmacies / chemist's
shops.
Eye protection:
Goggles which can be tightly sealed.
MSDS-No.: 557934 POLYCURE AC Page 5 of 9
V001.0
pH 7,0 - 8,5
(20 °C (68 °F))
Initial boiling point Not available.
Flash point Not available.
Decomposition temperature No data available / Not applicable
Vapour pressure No data available / Not applicable
Density 1,00 g/cm3
(20 °C (68 °F))
Bulk density No data available / Not applicable
Viscosity No data available / Not applicable
Viscosity (kinematic) No data available / Not applicable
Explosive properties No data available / Not applicable
Solubility (qualitative) No data available / Not applicable
Solidification temperature No data available / Not applicable
Melting point No data available / Not applicable
Flammability No data available / Not applicable
Auto-ignition temperature No data available / Not applicable
Explosive limits No data available / Not applicable
Partition coefficient: n-octanol/water No data available / Not applicable
Evaporation rate No data available / Not applicable
Vapor density No data available / Not applicable
Oxidising properties No data available / Not applicable
Sensitizing:
An allergic reaction cannot be excluded after repeated skin contact.
Skin corrosion/irritation:
12.1. Toxicity
No data available.
Waste code
080410
14.7. Transport in bulk according to Annex II of Marpol and the IBC Code
not applicable
MSDS-No.: 557934 POLYCURE AC Page 9 of 9
V001.0
15.1. Safety, health and environmental regulations/legislation specific for the substance or mixture
VOC content 0%
(VOCV 814.018 VOC regulation
CH)
Further information:
This information is based on our current level of knowledge and relates to the product in the state in which it is delivered. It is
intended to describe our products from the point of view of safety requirements and is not intended to guarantee any
particular properties.
The product is intended for industrial use.
Relevant changes in this safety data sheet are indicated by vertical lines at the left margin in the body of this document.
Corresponding text is displayed in a different color on shadowed fields.