Professional Documents
Culture Documents
DDTC144EE_DII
DDTC144EE_DII
Features
· Epitaxial Planar Die Construction A SOT-523
· Complementary PNP Types Available Dim Min Max Typ
(DDTA) A 0.15 0.30 0.22
B C
·
TOP VIEW
Built-In Biasing Resistors, R1 = R2 B 0.75 0.85 0.80
· Lead Free/RoHS Compliant (Note 1) C 1.45 1.75 1.60
G
Mechanical Data H D ¾ ¾ 0.50
G 0.90 1.10 1.00
· Case: SOT-523 K
N M
H 1.50 1.70 1.60
· Case Material: Molded Plastic. UL Flammability
Classification Rating 94V-0 J J 0.00 0.10 0.05
D L
· Moisture sensitivity: Level 1 per J-STD-020C K 0.60 0.80 0.75
· Terminal Connections: See Diagram L 0.10 0.30 0.22
· Terminals: Finish - Solderable per MIL-STD-202, Method M 0.10 0.20 0.12
208
N 0.45 0.65 0.50
· Lead Free Plating (Matte Tin Finish annealed over Alloy OUT
42 leadframe). a 0° 8° ¾
3
· Marking & Type Code Information: See Table Below and C
All Dimensions in mm
Last Page
· Ordering Information: See Last Page B R1
E
P/N R1, R2 (NOM) MARKING
2
DDTC123EE 2.2KW N04 1 2 E
DDTC143EE 4.7KW N08 GND(0)
DDTC114EE IN GND (0)
10KW N13
DDTC124EE 22KW N17
DDTC144EE 47KW N20 Schematic and Pin Configuration Equivalent Inverter Circuit
DDTC115EE 100KW N24
250
5
f = 1MHz
Pd, POWER DISSIPATION (mW)
200
4
100 2
50
1
0
0 0 10 15 30
5 20 25
-50 0 50 100 150
VR, REVERSE BIAS VOLTAGE (V)
TA, AMBIENT TEMPERATURE (° C) Fig. 2 Output Capacitance
Fig. 1 Derating Curve
100
150° C
150° C
-55° C
0.1
-25° C
0.01
1 0 10 20 30 40 50
1 10 100
IC, COLLECTOR CURRENT (mA) IC, COLLECTOR CURRENT (mA)
Fig. 3 Typical DC Current Gain Fig. 4 VCE(SAT) vs. IC
vs. Collector Current
100
VCE = 0.3V
VIN, INPUT VOLTAGE (V)
10
-55° C
1
150° C
0.1
0 10 20 30 40 50
150° C
hFE, DC CURRENT GAIN
100
150° C
0.1
25° C 75° C
-25° C
10 -55° C
-25° C 25° C 75° C
-55° C
1 0.01
1 10 100 0 10 20 30 40 50
IC, COLLECTOR CURRENT (mA) IC, COLLECTOR CURRENT (mA)
Fig. 6 Typical DC Current Gain vs Collector Current Fig. 7 VCE(SAT) vs. IC
100
VCE = 0.3V
Vin, INPUT VOLTAGE (V)
10
-25° C -55° C
1
150° C
75° C 25° C
0.1
0 10 20 30 40 50
IC, COLLECTOR CURRENT (mA)
Fig. 8 Input Voltage vs. Collector Current
VCE = 5V IC/IB = 20
150° C
hFE, DC CURRENT GAIN
100
150° C
0.1
25° C 75° C
-55° C -25° C
10
25° C 75° C
-25° C
-55° C
1 0.01
1 10 100 0 10 20 30 40 50
IC, COLLECTOR CURRENT (mA) IC, COLLECTOR CURRENT (mA)
Fig. 9 Typical DC Current Gain vs Collector Current Fig. 10 VCE(SAT) vs. IC
VCE = 0.3V
-55° C -25° C
1
150° C
75° C
25° C
0.1
0 10 20 30 40 50
IC, COLLECTOR CURRENT (mA)
Fig. 11 Input Voltage vs. Collector Current
100
150° C
0.1
-55° C -25° C 25° C
75° C
10
25° C 75° C
-55° C -25° C
1 0.01
1 10 100 0 10 20 30 40 50
IC, COLLECTOR CURRENT (mA) IC, COLLECTOR CURRENT (mA)
Fig. 12 Typical DC Current Gain vs Collector Current Fig. 13 VCE(SAT) vs. IC
100
VCE = 0.3V
Vin, INPUT VOLTAGE (V)
-25° C
10 -55° C 150° C
25° C
75° C
0.1
0 10 20 30 40 50
IC, COLLECTOR CURRENT (mA)
Fig. 14 Input Voltage vs. Collector Current
0.1
10
75° C
25° C
-55° C -25° C
0.01
1
0 10 20 30 40 50
1 10 100
IC, COLLECTOR CURRENT (mA)
IC, COLLECTOR CURRENT (mA)
Fig. 16 VCE(SAT) vs. IC
Fig. 15 Typical DC Current Gain vs Collector Current
100
VCE = 0.3V
Vin, INPUT VOLTAGE (V)
-25° C
10 -55° C 150° C
25° C
75° C
0.1
0 10 20 30 40 50
IC, COLLECTOR CURRENT (mA)
Fig. 16 Input Voltage vs. Collector Current
Marking Information
NXX = Product Type Marking Code (See Page 1)
YM = Date Code Marking
NXXYM Y = Year ex: T = 2006
M = Month ex: 9 = September
Date Code Key
Year 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012
Code N P R S T U V W X Y Z
Month Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Code 1 2 3 4 5 6 7 8 9 O N D
DS30313 Rev. 8 - 2 6 of 7 DDTC (R1 = R2 SERIES) E
www.diodes.com
IMPORTANT NOTICE
Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further
notice to any product herein. Diodes Incorporated does not assume any liability arising out of the application or use of any product described herein; neither
does it convey any license under its patent rights, nor the rights of others. The user of products in such applications shall assume all risks of such use and will
agree to hold Diodes Incorporated and all the companies whose products are represented on our website, harmless against all damages.
LIFE SUPPORT
Diodes Incorporated products are not authorized for use as critical components in life support devices or systems without the expressed written approval of the
President of Diodes Incorporated.