ROOFING SOR 1

SCHEDULE OF RATES

ROOFING

S/N DESCRIPTION UNIT RATE ($)

1 Supply and fix BRC 3315 to roof to support sisalation paper. m2 1.90

2 Supply and fix 25mm thick woodwool slab to roof. m2 23.10

3 Supply and fix 50mm thick woodwool slab to roof. m2 31.10

4 Supply and lay 900 x 600 x 20mm thick ferrocement secondary roof m2 31.70
slabs, reinforced with galvanised fine mesh to reinforced concrete flat
roof including all necessary supporting concrete solid blocks, labour
and materials for sealing up pipes, etc as specified (rate inclusive of
the provision of a 10-year warranty and shall be measured flat on
plan).

5 Supply and lay 600 x 600 x 30mm thick ferrocement secondary roof m2 21.13
slabs, reinforced with galvanised fine mesh to reinforced concrete flat
roof including all necessary supporting concrete solid blocks, labour
and materials for sealing up pipes, etc as specified (rate inclusive of
the provision of a 10-year warranty and shall be measured flat on
plan).

6 3mm thick acrylic polymer modified cementitious coating to roof m2 10.80


surfaces and gutter as specified.

7 Apply a complete Waterproofing Membrane System to reinforced m2 8.50


concrete flat roof consisting of 6 coats of waterproofing membranes, 1
layer of open woven glass membrane and 1 coat of bituminous
aluminium finishing paint as specified; complying with SS133:19 and
its latest amendments and in accordance with the manufacturer's
instructions ( rate inclusive of the provision of a 10-year warranty and
shall be measured flat on plan).

8 Apply a complete Panel Roofing System to roof surfaces consisting of m2 31.70


38mm thick waterproofing cement and sand panel (1:3), 50mm thick
Styrofoam insulation board or other approved equivalent and 6 coats of
waterproofing membranes, 1 layer of open woven glass membrane and
a minimum of 20mm thick waterproofing cement and sand screed (1:3)
laid to fall as specified and including all necessary labour and
materials for jointing (rate inclusive of the provision of a 10-year
warranty and shall be measured flat on plan).

9 Supply and fix 22G galvanised steel flashing not exceeding 400mm m 5.30
girth as specified.
ROOFING SOR 2

SCHEDULE OF RATES

ROOFING

S/N DESCRIPTION UNIT RATE ($)

10 Supply and install 0.6mm thick hot dipped galvanised steel Scantile m2 43.10
metal roofing coated with PVF2 Kynar 500 including all necessary
fixing accessories as specified and in accordance with manufacturer's
instructions.

11 Supply and install ridge/hip tile to Scantile metal roofing including all m 27.70
ridge/hip end capping piece and all necessary fixing accessories as
specified.

12 Supply and install 0.53mm thick Speed Deck Hi-Ten colorbond metal m2 32.90
roofing including all necessary fixing accessories as specified (rate
inclusive of the provision of a 10-year warranty).

13 Supply and install colorbond ridge capping (type A) to Speed Deck Hi- m 21.30
Ten roofing including all necessary fixing accessories as specified
(rate inclusive of the provision of a 10-year warranty).

14 Supply and install 0.47mm thick colorbond XRW Spandek Hi-Ten m2 31.90
metal roofing sheets including all necessary fixing accessories as
specified (rate inclusive of the provision of a 10-year warranty).

15 Supply and install 0.47mm thick colorbond XRW Trimdek Hi-Ten m2 29.30
metal roofing sheets including all necessary fixing accessories as
specified (rate inclusive of the provision of a 10-year warranty).

16 Supply and install 0.53mm thick colorbond XRW Kliplok Hi-Ten m2 38.30
metal roofing sheets including all necessary fixing accessories as
specified (rate inclusive of the provision of a 10-year warranty).

17 Supply and install 0.65mm thick colorbond XRW Kliplok Hi-Ten m2 45.10
metal roofing sheets including all necessary fixing accessories as
specified (rate inclusive of the provision of a 10-year warranty).

18 Supply and install 0.47mm thick colorbond XRW V-Crimp Hi-Ten m2 30.40
metal roofing sheets including all necessary fixing accessories as
specified (rate inclusive of the provision of a 10-year warranty).

19 Supply and install 0.60mm thick colorbond XRW standard ridge m 12.00
capping to Kliplok roofing including all necessary fixing accessories
as specified (rate inclusive of the provision of a 10-year warranty).

20 Supply and install 0.60mm thick custom made colorbond XRW m 5.40
flashings/cappings/trims not exceeding 100mm girth to Kliplok/
Spandek/V-Crimp roofing including all necessary fixing accessories as
specified (rate inclusive of the provision of a 10-year warranty).
ROOFING SOR 3

SCHEDULE OF RATES

ROOFING

S/N DESCRIPTION UNIT RATE ($)

21 Supply and install 0.60mm thick custom made colorbond XRW m 7.40
flashings/cappings/trims exceeding 100mm but not exceeding 200mm
girth to Kliplok/Spandek/V-Crimp roofing including all necessary
fixing accessories as specified (rate inclusive of the provision of a 10-
year warranty).

22 Supply and install 0.60mm thick custom made colorbond XRW m 10.60
flashings/cappings/trims exceeding 200mm but not exceeding 300mm
girth to Kliplok/Spandek/V-Crimp roofing including all necessary
fixing accessories as specified (rate inclusive of the provision of a 10-
year warranty).

23 Supply and install 0.60mm thick custom made colorbond XRW m 13.50
flashings/cappings/trims exceeding 300mm but not exceeding 400mm
girth to Kliplok/Spandek/V-Crimp roofing including all necessary
fixing accessories as specified (rate inclusive of the provision of a 10-
year warranty).

24 Supply and install 0.60mm thick custom made colorbond XRW m 16.40
flashings/cappings/trims exceeding 400mm but not exceeding 500mm
girth to Kliplok/Spandek/V-Crimp roofing including all necessary
fixing accessories as specified (rate inclusive of the provision of a 10-
year warranty).

25 Supply and install 0.60mm thick custom made colorbond XRW m 19.50
flashings/cappings/trims exceeding 500mm but not exceeding 600mm
girth to Kliplok/Spandek/V-Crimp roofing including all necessary
fixing accessories as specified (rate inclusive of the provision of a 10-
year warranty).

26 Supply and install 0.60mm thick custom made colorbond XRW m 22.20
flashings/cappings/ trims exceeding 600mm but not exceeding 700mm
girth to Kliplok/Spandek/V-Crimp roofing including all necessary
fixing accessories as specified (rate inclusive of the provision of a 10-
year warranty).

27 Supply and lay one layer of 'Parsec Thermo-brite II' double sided m2 8.20
reflective roof heat insulation sheet including lapping with 'Parsec
Thermo-brite' tape and secured to roof structure by self-drilling
fasteners complete with metal washers as specified and in accordance
with manufacturer's instructions.

28 Supply and lay one layer of 'Super Sisalation' double sided reflective m2 7.00
roof heat insulation sheet including lapping with PPC 493 reinforced
aluminium foil tape and secured to roof structure by self-drilling
fasteners complete with metal washers as specified and in accordance
with the Manufacturer’s instructions.
ROOFING SOR 4

SCHEDULE OF RATES

ROOFING

S/N DESCRIPTION UNIT RATE ($)

29 Supply and lay one layer of 'Super Brite' double sided reflective roof m2 7.00
heat insulation sheet including lapping and secured to roof structure by
self-drilling fasteners complete with metal washers as specified and in
accordance with manufacturer's instructions.

30 Supply and lay "Heisterholz K 21" semi-glazed shale clay roofing tiles m2 71.40
laid on and including 50 x 25mm timber batterns with 125mm head
laps and 52mm side laps including all necessary fixing accessories as
specified.

31 Extra Over "Heisterholz K 21" semi-glazed shale clay roofing tiles for m 38.60
Right/Left verge tiles as specified.

32 Extra Over "Heisterholz K 21" semi-glazed shale clay roofing tiles for m 12.30
Boarding Plate tiles as specified.

33 Supply and lay "Heisterholz K 21" semi-glazed shale clay roofing m 58.10
Ridge/Hip tiles including cement mortar (1:3) packing as specified.

34 Extra Over "Heisterholz K 21" semi-glazed shale clay roofing no 47.90


Ridge/Hip tiles for Ridge Start/End tile including cement Mortar (1:3)
packing as specified.

35 Supply and lay "Ergoldsbacher" plain unglazed coloured roof tiles m2 119.50
(straight cut with rounded corners) in double tiling pattern laid on and
including 50 x 25mm timber battens complete with all necessary fixing
accessories as specified.

36 Supply and lay "Ergoldsbacher" plain unglazed coloured roof ridge m 63.10
tiles no. 16 including cement mortar (1:3) packing as specified.

37 Extra Over "Ergoldsbacher" plain unglazed coloured roof ridge tiles no 9.60
no. 16 for Ridge Start/End tile including cement mortar (1:3) packing
as specified.

38 Extra Over "Ergoldsbacher" plain unglazed coloured roof mortar (1:3) no 225.00
packing as specified.

39 Supply and install 10mm thick Acrylic / Perspex sheet complete with m2 157.00
aliminium / metal frames including all necessary coating finishes
ROOFING SOR 5

SCHEDULE OF RATES

ROOFING

S/N DESCRIPTION UNIT RATE ($)

Supply and install polycarbonate sheet to linkway, pavilion, etc,


complete with aliminium / steel frames including all necessary coating
finishes

40 5mm thick m2 184.00

41 6mm thick m2 218.00

42 9mm thick m2 276.00

43 Supply and install 9mm thick polycarbonate sheet m2 135.00

44 Supply and install 0.63mm thick “EAGLE Tile” roofing sheet to steel m2 45.00
purlins with bilts, nuts, washers, sealing washers, fixing brackets and
all necessary accessories. Material shall be of 0.42-0.55mm base metal
with zinc/aluminium alloy coated to a minimum 150g/m2 total both
sides or zinc coated ZM275. Tile total coated thickness of 0.48-
0.63mm, width of 7550mm (actual) 2580 (effective cover), tile
coverage of 0.95m2 per tile, sidelap 170mm and weight 5-7kg per tile.
Finish with multicote coating systems and all setting out and
installation to manufacturer’s specifications.

45 Supply and apply 1 coat of "Newcoat" Primer S m2 0.40

46 Supply and apply 1 coat of "Newcoat" water based acrylic polymer m2 2.50
waterproofing membrane with integral micro fibre reinforcement
(adhoc repair) (Removal of existing waterproofing membrane
measured separately)

47 Supply and apply complete "Newcoat" roof waterproofing system m2 7.00


consisting of 3 coats of "Newcoat" water based acrylic polymer
waterproofing membrane with integral micro fibre reinforcement
including 1 coat of Primer S (complete system) (Removal of existing
waterproofing membrane measured separately)

122 Supply & lay all types of roof tiles (all colours) to pitch roof including m2 82.40
stripping off existing and removing debris off site.
Exceeding 5 pieces (measured net)

123 Supply & lay in repairs of roof tile including stripping off existing and no 6.50
removing debris off site
Roof tiles not exceeding 5 pieces

124 Supply & lay in repairs of roof tile including stripping off existing and m2 62.20
removing debris off site
Roof tiles exceeding 5 pieces (measured net)
ROOFING SOR 6

SCHEDULE OF RATES

ROOFING

S/N DESCRIPTION UNIT RATE ($)

Aluminium Composite Panel


Supply and install aluminium composite panel sandwiched between 2
skins of aluminium alloy of 0.5mm thick with PVDF coating (top) and
polyester white/mill finish (bottom) complete with necessary capping
(standard colour) complying with BS 476 Part 4, 6 & 7

453 3mm thick m2 126.50

454 4mm thick m2 138.00

455 6mm thick m2 149.50

Supply and install aluminium honeycomb composite panel sandwiched


between 2 skins of aluminium alloy of 1mm thick with pvdf coating
(top) and 0.5mm thick in polyester white/mill finish (bottom) complete
with necessary capping (standard colour) complying with BS 476 Part
4, 6 & 7

456 10mm thick m2 172.50

457 20mm thick m2 207.00

458 Supply and install sandwich panels 10.65mm thick enamel steel top m2 218.50
sheet 0.8mm aluminium fluorcarbon finish bottom sheet bonded to
10mm thick aluminium honeycomb as core include aluminium capping
and end capping (powder coated finish)

459 Extra over item 453 to 458 for curving of composite panel m2 19.50

460 Provide powder coating to all metal work surface m2 12.00

461 Supply and lay asbestos-free corrugated roofing sheets (any profile) to m2 21.80
match existing including stainless steel screws

462 Supply and fix asbestos-free ridge fitting m 27.00

463 Supply and fix 12mm thick gypsum board as ceiling board including m2 22.90
removal of existing sheet and mild steel hollow section and support if
necessary

464 Supply and fix 6mm thick “Cape Masterboard” asbestos free m2 20.60
buildingboards as ceiling board in fill to suspended system or nailed to
timber joints

465 Supply and fix 12mm thick “minaboard” or other approved mineral m2 22.10
fibre or glass fibre ceiling board in fill including “L” shape aluminium
stiffener, if necessary