R4830N2 Rectifier User Manual V1.

Environmental Specifications
Item Specification
Operating -40ºC to +75 ºC(referring
temperature to Figure 3)
Storage -40ºC to +75ºC(not
temperature packaged)
Relative humidity 5%-95% (non-condensing)
Altitude range ≤ 4000 m

Efficiency The peak point is ≥94%;


≥93%(230V AC,30%–100% load)
Note: If the altitude is within the range of 3000 m to 4000 m, the maximum operating
Height x Width x Depth 41 mm x 95.5 mm x 208 mm temperature decreases by 1 °C (1.8°F ) as the altitude increases by 200 m.

Weight ≤1.3 kg
Electrical Specifications
Cooling Built-in fan(The rotation of fan
Item Specification
depends on the internal
temperature.) Input
Operating voltage 85–300 V AC

Description
Frequency 45–66 Hz
Rated : 50Hz and 60 Hz
The R4830N2 is a digital rectifier with high efficiency and
power density.It converts 85–300 V AC input voltage to Rated input current ≤10 A
53.5 V DC output voltage. The output voltage can be
Power factor ≥ 0.99 (load≥50% )
adjusted by the host.
It performs comprehensive protection functions, supports
soft start, and produces low noise. With the latest power THD ≤ 3.5% (full load)
monitoring technology, states of the rectifier and load are ≤5% (load≥50% )
monitored in real time. Output
Multiple rectifiers can be paralleled.
Output voltage 42–58 V DC
Rated voltage: 53.5 V DC

Key Features Output power 1605 W (176–300 V AC);


755 W (85–175 V AC decreased
• Input voltage range: 85–300 V AC linearly)
• Operating temperature range: –40ºC to +75ºC Regulated voltage ≤±0.6%Vo
precision
• Total harmonic distortion (THD): ≤ 3.5%
Ripple and noise ≤ 200 mVp-p
• Digital control mode (Bandwidth≤20MHz)
• Hot swap Dynamic response Over shoot:≤ ±5% Vo
• Supports intelligent electric meter Recovery time: ≤ 200 us
Standby power ≤5W
• Supports CAN communication
Turn-on output delay 3–8s
• Supports LED display
Hold up time >10 ms
• Supports voltage adjustment,current
adjustment,and current sharing Psophometrically ≤ 2 mV
weighted noise
• Meet Rohs requirement
Wideband noise ≤ 50 mV (3.4k–150 kHz)
• Passes the TUV, CE,UL certifications and gets voltage ≤ 20 mV (0.15M–30MHz)
the CB certificate.
• Disconnect above 320 V AC HUAWEI TECHNOLOGIES CO., LTD.
1
R4830N2 Rectifier User Manual V1.0

Other Features
Item Specification Output Feature
Protection
Figure 1 Output feature
Input overvoltage Protection point:>300 V AC
Output Voltage vs. Output Current
protection
Recovery range:290–300 V AC 70

Input undervoltage Protection point:<80 V AC 60


protection
Recovery range:70–85 V AC

Output Voltage(V)
50

Output overvoltage 56–60 V DC (can be set by 40


protection monitoring unit )
30
1.If the overvoltage occurs inside the
rectifier due to a fault, the rectifier will 20
latch off.
10
2.If the output voltage is higher than 63
V and lasts for more than 500 ms, the 0
rectifier will latch off. 0 5 10 15 20 25 30 35 40

Output Current (A)


Output current See Figure 1.
limiting protection
Figure 2 Efficiency
Output short circuit A long term short circuit is allowed. (Vin = 230 V AC, Vout =53.5 V, Ta:25 ºC)
protection After the fault is rectified, the rectifier is
Efficiency
restored to a healthy state
automatically. 96

Over-temperature The module protects against 94

protection overtemperature. 92

Safety/EMC/Lightening protection
EFFI

90

Safety Passes TUV, CE, UL certifications. 88


certification Catch the CB certificate.
86
Complies with
UL60950-1;IEC60950-1;EN60950-1; 84
CAN/CSA C22.2 No. 60950 -1 ; 0 5 10 15 20 25 30
LOAD(A)
EMC EN55022 Class B ;
EN55024;
Figure 3 Power derating curve
EN61000-3-2;
EN61000-3-3; Power Derating Curve
ETSI EN300 386; 1800
ETSI EN301489; 1600
ITU-T K.20; 1400
1200
Lightning 5 KA
Po(w)

1000

Reliability 800
600
MTBF > 500,000 hours 400
200
Audible Noise 0
-40 -20 0 20 40 60 80
Specification ≤45dB(25 ºC,full load)
Ta(℃)

HUAWEI TECHNOLOGIES CO., LTD.


2
R4830N2 Rectifier User Manual V1.0

Interface Description CAUTION


• Only trained and qualified personnel can be allowed
The rear panel of the rectifier provides an golden to install or service the rectifier. To avoid electric
finger connection which is used as AC input, DC shock or burning, Wear antistatic clothes, antistatic
gloves, and ESD wrist straps before operating the
output and signal connection. For the location of rectifier.
the pins, see Figure 4. For the definitions of the
• Each rectifier input is protected by two fuses, one for
pins, see Table 1. the live wire and the other for the neutral wire.

Figure 4 Pins on the rear panel Removing the Rectifier


Figure 5 Removing a PSU

Step 1: Push the locking latch left.


Step 2: Remove the PSU out of the PDU by
externally drawing the handle, as shown
in Figure 5.

Installing the Rectifier


Figure 6 Installing a PSU

Step 1: Push the locking latch left and pull out


the handle.
Step 2: Push the PSU slowly into the subrack
along the guide rail and push the locking
latch right to fix the handle, as shown in
Figure 6.

Table 1 Definitions of the pins on the rear panel Transport


Pin Definition Function The product must be packed with firmly packing box
when transport. Out of the box the mark “prevent
1、8 L Live line
moisture ”,”lay down carefully” and other required
2、9 N Neutral line mark must have. Any transport tools are permitted if
3、10 PE Protect earth the product in the packing box .When transport
must avoid rain and snow attack directly and
4 CANL CANL mechanical shock.
12 CANH CANH
5 ACD2 Slot detect signal 2
Storage
11 ACD1 Slot detect signal 1
Product should be packaged in the packing box
6 OUTPUT+ Output:48V+ before use .The store room should be meet :-40 ℃
7、14、15 OUTPUT- Output:48V- to +70℃ ambient temperature ,related humidity
less than 80%,dry ,ventilation and hasn’t any
13 Pre-Charge Pre-Charge corrosive gas.

HUAWEI TECHNOLOGIES CO., LTD.


3
R4830N2 Rectifier User Manual V1.0

Maintenance
DANGER
• The high -voltage power supply energize equipment. Contacting the high-voltage power supply directly or through a dampened
object may cause you to death.
• Improper operations on the high-voltage power supply may cause accidents such as fire or electric shock.

Base on following suggestion, Simple fault can be dealt with .


Table 2 Describes the states of LEDs and the causes for abnormal.

Indicator Color Status Description Measures


Power Green Steady The rectifier is supplied with alternating The rectifier runs properly, and no
indicator on current (AC) input power. measure is required.
Off The rectifier is not supplied with AC input Replace the rectifier if the AC input is
power. normal.
The rectifier is faulty. Replace the rectifier.
Blinking The rectifier is being queried. No measure is required.
at 0.5 Hz
Blinking The rectifier is loading an application The rectifier automatically recovers after
at 4 Hz program. loading, and no measure is required.
Alarm Yellow Off No alarm is generated. The rectifier runs properly, and no
indicator measure is required.
Steady The rectifier generates a prewarning for Check that the air vent is not blocked and
on power limiting due to overtemperature. the ambient temperature is within a
The rectifier generates an alarm for normal range.
shutdown due to ambient
overtemperature or undertemperature
protection.
The rectifier generates an alarm due to Check that the electrical grid voltage is
AC input overvoltage or undervoltage within a normal range.
protection.
The rectifier is hibernated. No measure is required.
Blinking The rectifier communication Replace the rectifier or monitoring
at 0.5 Hz is interrupted. module.
Fault Red Off The rectifier is not faulty. No measure is required.
indicator
Steady The rectifier is locked due to output Pull out the rectifier and reinsert it after 1
on overvoltage. minute.
There is no output because the rectifier Replace the rectifier.
is faulty.

Suggestions

1. Rectify the faults by referring to Table 2.


2. If you cannot rectify the fault according to Table 2, replace the rectifier.
3. Return the faulty rectifier to Huawei for repairing.
Huawei Technologies Co., Ltd.