Electrical Component

S.No. Description Qty Unit Rate


Sub Head-I (Shifting of Street light poles)
10 Shifting of 6.0 metre long street light pole along with loop in
loop out box, light bracket , light fitting including lifitng and
errecting on street light pole CC pedestal (CC pedestal rate not
included) by mechanical means i/c supplying & fixing of 4 Nos.
16 mm dia, 750 mm long foundation 'J' bolt with double nut 10 Each
at top (to be fixed in CC pedestal during casting),
etc as required.

11 Manufacturing, Supply and Installation of Ornamental type GI


street light bracket made of approved type and design with 32 mm
dia., ISI marked medium class GI pipe 500 mm (Nominal) out reach
from street light pole complete with 0.5 m long, 100 mm dia heavy
class GI collar with MS cap on top, supporting the bracket with 20
mm dia. medium class, GI pipe, painting with one coat of 145.00 Kgs
Anticorrosive Primer and two or more coats of automotive grade
metallic paint of approved brand and shade, etc., as
required.

12 Earth work in excavation by mechanical means (Hydraulic


excavator) / manual means in foundation trenches or drains
(not exceeding 1.5 m in width or 10 sqm on plan), including dressing
of sides and ramming of bottoms, for all lift, including getting out
the excavated soil and disposal of surplus excavated soil as
directed,
within a lead of 50 m.
All kinds of soil. 8 Cum
13 Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work
up to plinth level :
1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural 1 Cum
sources : 10 graded stone aggregate 40 mm nominal size
derived from natural sources)
14 Providing and laying in position specified grade of reinforced
cement concrete, excluding the cost of centering, shuttering,
finishing and reinforcement - All work up
to plinth level :

1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural 4 Cum
sources : 3 graded stone aggregate 20 mm nominal size
derived from natural sources)
15 Centering and shuttering including
strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, 23 Sqm
etc. for mass concrete
16 Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
upto plinth level.
Thermo-Mechanically Treated bars of 150 Kg
grade Fe-500D or more.
17 Providing 6 mm thick cement plaster of
following mix :
1:3 (1 cement : 3 fine sand) 12 Sqm
18 Supplying and fixing street light luminaire with die cast
aluminium housing and toughened glass/ cover with min IP66
degree of protection, Individual LED with optical lens for better
light distribution throw across and along the road, with
luminaire efficacy of greater than 100 Lumen / watt, colour
rendering Index
The luminaire should have 5 KV surge
designed thermal management system with aluminium heat
sink. The Driver used be a constant current driver with
loop earthing, testing and commissioning etc. as required.

35-45 W with minimum 4000 lumens lamp output 10 Each


19 Supplying and drawing 1.5 sq mm PVC insulated PVC round
sheathed (un armoured) 3 core copper conductor cable in existing
PVC conduit / street light pole 80 Metre
from looping box to fitting as required.

20 Supplying of following sizes of XLPE insulated and PVC


sheathed aluminium conductor armoured cable of 1.1 KV grade in
the existing RCC/ HUME / METAL pipe /Surface /Tray
/connections conforming to IS:7098 (Part-I) 1988 with upto date
amendments duly ISI marked
complete as required.

a) 4 x 16 sq. mm 400 Metre


21 Laying of one number PVC insulated and PVC sheathed / XLPE
power cable of 1.1
KV grade of following size in the existing RCC/ HUME/ METAL pipe
as required.

Upto 35 sq. mm 370 Metre


22 Supplying and making end termination with brass
compression gland and aluminium lugs for following size of PVC
insulated and PVC sheathed / XLPE aluminium conductor cable
of 1.1 KV grade
as required.
a) 4 X 16 sq. mm (28mm) 20 Each
23 Providing and fixing 6 SWG dia G.I wire on surface or in recess for
loop earthing along with existing surface/ recessed conduit/
submain wiring/ cable as 800 Metre
required.

24 Supplying and laying of following size DWC HDPE pipe ISI marked
along with all accessories like socket, bend, couplers etc. conforming
to IS 14930, Part II complete with fitting and cutting, jointing
etc.direct in ground (75 cm below ground level) including
excavation and refilling the trench but excluding sand cushioning
and protective covering etc., complete as
required.

a) 63 mm dia (OD-63 mm & ID-51 mm nominal) 20 Metre


Sub Head-II (Pumpsets)
Pump Panel
25 Supplying, installation, testing and commissioning of
Outdoor type motor control panel (as per general arrangement
drawing approved by engineer-in-charge) suitable for operation on
415V, 3 Phase, 4 Wire, 50 Hz, AC supply system, fabricated in totally
enclosed compartmentalized flush finish made made out of 2 mm
thick CRCA sheet for frame work and covers, compartmentalized,
dust and vermin proof, hinged doors with knobs & with
locking arrangement, 3mm thick gland plate including. cleaning
and finishing with
7 tank process for powder coating in approved shade,
provision for incoming & outgoing termination from bottom of the
panel, 100 amps capacity 4 strip aluminum bus bars of high
conductivity, DMC/ SMC bus bar supports, PVC sleeves, bottom base
channel of ISMC 75 (75 mm x 40 mm x 4.4 mm thick), copper earth
bar of size 25mm x 5 mm at the rear for the entire width of the
panel with 2 nos. earth studs
,connections from busbar to switchgear and control wiring with
required size FRLS
PVC insulated copper conductor cable of suitable size,

cable alley, cable gland for supporting and fixing the following
switchgear, as per attached specifications and confirming to the
CPWD general specifications part-I (Internal), part-II (External),
part-IV (Sub
station).

Incoming:
a) 63 A, 4 pole MCCB, 25 KA rating, (Icu=100% Ics) thermal
magnetic release type complete with Rotary handle,
spreader terminals etc. - 1 No.
b) Digital Multifunction Meter with RS485
port - 1 No.
c) R,Y,B LED indication lamps along with
2A control MCBs - 1 set.
d) Suitable ratio CTs - 1 set.
Outgoing:
2Nos DOL starter control compartments
suitable for 7.5HP motors including supplying and fixing
following items in
each compartment

a) 40A TP MCB - 1 No.


b) DOL starter with thermal over relay - 1 Set
c) Single phasing and Dry run preventer
(current sensing type) - 1 No.
d) Digital ammeter - 1 No.
e) ON/OFF illuminated push buttons - 1
set.
f) Trip indication lamps - 1 No.
g) Auto/Manual Selector switch - 1 No. 1 Each
Sub Head-III (HT Cabling)
26 Supplying aluminium conductor, XLPE insulated PVC sheathed
armoured power cable of 11KV(Earthed) grade conforming to
IS:7098/(Part-II)1988 amended upto
date of following size.

a) 3 X 120 sq mm 180 Metre


27 Laying of one number PVC insulated and PVC sheathed / XLPE
power cable of 11 KV grade of following size direct in ground including
excavation, sand cushioning, protective covering and refilling the
trench
etc as required.

a) Upto 120 sq. mm 20 Metre


28 Laying of one number PVC insulated and PVC sheathed / XLPE
power cable of 11 KV grade of following size in the existing
RCC/ HUME/ METAL pipe as required.
a) Upto 120 sq. mm 20 Metre
29 Laying of one number PVC insulated and PVC sheathed/ XLPE power
cable of 11 KV grade of following size in the existing
masonry open duct as required.
a) Upto 120 sq. mm 140 Metre
Sub Head-IV (Yard Fencing)
30 Providing and fixing fencing to a height of
2.1 metres with chain link mesh/welded mesh (made of 8 SWG GI
wire with 50 mm x 50 mm mesh size) welded to G.I (hot dipped
Galvanized Iron) angle iron frame of 50 mm x 50 mm x 5 mm of
3.1 m total length( 1.0 m below ground and 2.1 m above ground
and width not more than 1.5 metre to form continuous support at
top and bottom and assembled at site to form the required
fencing. All the vertical members of frame shall be extended by 100
cm for errection in ground & GI flat of size
25 mm x 5 mm shall be welded in the center of the frame to
provide additional support to G.I mesh including erection of the 110 Metre
angle iron frame in 1:2:4 cement concrete of size 0.23 m (L) x
0.23 m (B) x
0.70 m below ground & 0.3 m above ground including
excavation, painting with aluminium paint etc., as required (to be
measured on linear basis).

31 Providing and fixing Pre-fabricated gate for transformer yard


consisting of two leaves of size 2.1 metre (height) x 1.25 metre
(width) (total width 2.5 metre) fabricated out of angle iron frame
work with 50 mm x 50 mm x 5 mm angle iron equally spaced across
the height of the gate, including welding wire mesh made of 8
SWG GI wire having 50 mm x 50 mm nominal mesh size for each leaf
welded to the two frames on both sides to a channel iron support
made of each 3.1 metre long MS channel of designation ISMC 100
(9.2 Kg/mtr.) (GI flat of size 25 mm x 5 mm shall be welded in the
center of the frame to provide additional support to G.I 3 Each
mesh using a suitable suspension arrangement heavy duty
hinges providing locking arrangement erection of the
vertical support in 1: 2: 4 cement concrete (1 cement
: 2 coarse sand : 4 graded stone aggregate 40mm nominal size)
of size 0.23m(L) x 0.23m(B) x 0.7m below ground & 0.3m
above ground in such way as to ensure proper alignment etc., as
required.

32 Supply and spreading quarry dust of


approved quality (granite dust) in the yard complete as required . 60 Cum
33 Supplying & spreading of 40 mm nominal size stone aggregate
in the yard and 60 Cum
levelling etc. as required.
34 Earth work in excavation by mechanical means (Hydraulic
excavator) / manual means in foundation trenches or drains
(not exceeding 1.5 m in width or 10 sqm on plan), including dressing
of sides and ramming of bottoms, for all lift, including getting out
the excavated soil and disposal of surplus excavated soil as
directed,
within a lead of 50 m.
(a) All kinds of soil. 70.00 Cum
35 Providing and laying in position cement concrete of specified grade
excluding the
cost of centering and shuttering - All work up to plinth level :
(a) 1:5:10 (1 cement : 5 coarse sand (zone- III) derived from 15.00 Cum
natural sources : 10 graded stone aggregate 40 mm nominal
size derived from natural sources)
36 6 mm cement plaster of mix :
(a) 1:3 (1 cement : 3 fine sand) 80.00 Sqm
37 Brick work with common burnt clay F.P.S.
(non modular) bricks of class designation
7.5 in foundation and plinth in:
(a) Cement mortar 1:4 (1 cement : 4 coarse sand) 20 Cum
Sub Head-V (Switch gear Panel)
38 Fabrication, supply and installation of wall/floor mounted
outdoor type MV cubical enclosure , fabricated out of 14 SWG
( 2.0 mm ) nominal thickness CRCA sheet steel duly powder coated
type, of size not less than 600 mm (Width) x 1000 mm (Height) x
800 mm (Depth), front openable, hinged, single shuttered, double
door on front , with locking arrangement, good quality dust,
damp and vermin proof rubber gaskets, earth studs,
including fixing of following switch gear, drilling holes, detachable
gland plates / knockout plates for facilitating entry / exit of UG
cables, i/c fixing of enclosure on wall/floor mounted with dash
fastners, bottom base frame with MS channel (ISMC 75
designation) of section not less than 75 mm X 40 mm X 4.4 mm thick.
etc complete as
required.

a) 400 Amps four pole, 50KA breaking capacity (Icu=Ics) at


415V short circuit current rating MCCB, microprocessor type
release with over load and short circuit fixed, in-built earth
fault protection, spreader links, rotary handle - 1 Nos

b) 3 Nos. Phase indication LED lamps with 2 Amp backup MCB, 1 Job
breaker ON / OFF LED indicating lamps with 2 Amp backup
MCB - 1 Sets.
Sub Head-VI (LT Cables)
39 Supplying of following sizes of XLPE insulated and PVC
sheathed aluminium conductor armoured cable of 1.1 KV grade
conforming to IS:7098 (Part-I) 1988 with upto date amendments
duly ISI marked
complete as required.

a) 3 ½ x 300 sq.mm 400 Metre


40 Laying of one number PVC insulated and PVC sheathed / XLPE
power cable of 1.1 KV grade of following size in the existing
RCC/ HUME/ METAL pipe as required.
Above 185 sq. mm and upto 400 sq. mm 380 Metre
41 Supplying and laying of following size DWC HDPE pipe ISI marked
along with all accessories like socket, bend, couplers etc. conforming
to IS 14930, Part II complete with fitting and cutting, jointing
etc.direct in ground (75 cm below ground level) including
excavation and refilling the trench but excluding sand cushioning
and protective covering etc., complete as
required.

a) 63 mm dia (OD-63 mm & ID-51 mm nominal) 40 Metre


42 Supplying and installing following size of perforated Hot Dipped
Galvanised Iron cable tray (Galvanisation thickness not less than 50
microns) with perforation not more than 17.5%, in convenient
sections, joined with connectors, suspended from the ceiling
with G.I. suspenders including G.I.
bolts & nuts, etc. as required.

a) 300 mm width X 50 mm depth X 1.6 mm thickness 25 Metre


b) 150 mm width X 50 mm depth X 1.6 mm thickness 25 Metre
c) 100 mm width X 50 mm depth X 1.6 mm thickness 25 Metre
43 Providing, laying and fixing following dia RCC pipe NP2 class (light
duty) in ground complete with RCC collars, jointing with
cement mortar 1:2 (1 cement : 2 fine sand)
including trenching (75 cm deep) and refilling etc as required.
a) 300 mm dia 60 Metre
44 Supply, fabrication and erection of MS angle, channel iron
supports for E&M equipments/ pipelines/cable supports etc.,
including cutting, welding, painting, complete as required.(for 2500 Kgs
cable supports in
cable trench)
Sub Head-VII (UPS Outgoing panel)
45 Supplying, installation, testing and commissioning of indoor
type cubical LT Essential panel (as per general arrangement drawing
approved by engineer-in-charge) suitable for operation on 415V, 3
Phase, 4 Wire, 50 Hz, AC supply system, fabricated in totally
enclosed compartmentalized flush finish made made out of 2 mm
thick CRCA sheet for frame work and covers, compartmentalized,
dust and vermin proof, hinged doors with knobs & with
locking arrangement, 3mm thick gland plate i/c. cleaning and
finishing with 7 tank process for powder coating in
approved shade, provision for incoming & outgoing termination
from Top/bottom of
the panel with cable chamber,

and fabrication of the panel shall be done in transportable sections,


entire width of the panel shall have a common copper earth bar of
size 2 Nos x 25 mm x 5 mm at the rear with 2 Nos. earth stud,
connection and interconnections from main bus bar to switch gears
with required size of aluminium bus bars and control wiring
with 1.5 sq.mm & CT wiring with 2.5 sq mm FRLS PVC insulated
copper conductor single core cable, cable alleys, detachable cable
gland plates including providing and fixing the following MCCB/
Switchgears
/metering accessories etc
complete as required. Ventilation, bottom base frame with MS
channel (ISMC 75 designation) of section not less than 75 mm X 40
mm X 4.4 mm thick. The cubical panel shall generally confirm to
CPWD General Specification for Electrical works, Part-I Internal
2013, Part II External 1994 and Part IV substation equipment 2013 as
amended
upto date.
The size of the Panel shall be not less than 1000 mm (Width) x 1500
mm (Height) x 300
mm (Depth) and shall be erected on
existing cement concrete or brick masonry
foundation as per directions of Engineer-in- charge.
Incoming
b) 160 Amps. 4 pole, Moulded Case Circuit Breaker (MCCB), 36 KA
breaking capacity (Icu=Ics) with thermal magnetic release, with
over load and short circuit protection, spreader links, rotary handle,
ON/OFF indication lamps with MCB protection, etc -
1 Nos.

b) 3 Nos. Phase indication LED lamps with 2 Amp backup MCB,


breaker ON / OFF LED indicating lamps with 2 Amp backup
MCB - 1 Sets.

c) Digital type Multi-function meter with


RS485 port - 1 Sets
Bus Bars:
Horizontal and vertical 4 strip aluminium bus bars of 200 Amps
capacity with heat shrinkable coloured sleeves and i/c
DMC/SMC bus bars supports at required intervals complete
suitable for withs tanding fault level of 31 MVA for 1 Sec. - 1
Set

Out going:
a) 100 Amps. 4 pole, Moulded Case Circuit Breaker (MCCB), 25 KA
breaking capacity (Icu=Ics) with thermal magnetic release, with
over load and short circuit protection, spreader links, rotary handle,
ON/OFF indication lamps with MCB protection, etc -
2 Nos.

b) 63 Amps. 4 pole, Moulded Case Circuit Breaker (MCCB), 25 KA


breaking capacity (Icu=Ics) with thermal magnetic release, with
over load and short circuit protection, spreader links, rotary handle,
ON/OFF indication lamps with MCB protection, etc -
1 Nos.

c) Digital type Multi-function meter with 1 Job


RS485 port for all outgoing switches.
Sub Head-VIII (Shifting of exisiting
40KVA DG set)

46 Dismantling the existing 40 kVA DG set including disconnecting


power and control cables, exhust pipe coonections, lifting by using
suitable capcity crane, shifting the DG set with all accessories to
new DG set location in the same campus, errect the DG set with 1 Job
suitable capacity crane, keeping in designated position, making
electrical
power and control cables, refixing exhaust
pipe connections etc., testing and
commissioning the DG set as required. (excluding foundation
works)
47 Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick
including accessories, and providing masonry enclosure with cover
plate having locking arrangement and watering pipe of 2.7 metre
long etc. 2 Set
with charcoal/coke and salt as required.

48 Providing and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I.


pipe from earth electrode including connection with brass nut, bolt, 20 Metre
spring, washer excavation and re- filling etc. as required.
49 Providing and fixing 25mm x 5mm copper strip on surface or in recess
for connections etc. as required. 20 Metre
50 Supplying of following sizes of XLPE insulated and PVC
sheathed aluminium conductor armoured cable of 1.1 KV grade
conforming to IS:7098 (Part-I) 1988 with upto date amendments
duly ISI marked
complete as required.

d) 4 x 25 sq.mm 80 Metre
51 Laying of one numberPVC insulated and PVC sheathed / XLPE
power cable of
1.1KV grade of following size in the existing RCC / HUME /
TRAY/ METAL
pipe as required.

UP to 35 sq.mm 70 Metre
52 Supplying and making end termination with brass
compression gland and aluminium lugs for following size of PVC
insulated and PVC sheathed / XLPE aluminium conductor cable
of 1.1 KV grade
as required.
b) 4 X 25 sq. mm (38mm) 3 Each
53 Supplying and laying of following size DWC HDPE pipe ISI marked
along with all accessories like socket, bend, couplers etc. conforming
to IS 14930, Part II complete with fitting and cutting, jointing
etc.direct in ground (75 cm below ground level) including
excavation and refilling the trench but excluding sand cushioning
and protective covering etc., complete as
required.

a) 63 mm dia (OD-63 mm & ID-51 mm nominal) 60 Metre