• Superior coating extends tank life and reduces life cycle For the best tank solution
maintenance costs for your fire protection needs
• Ability to disassemble and reassemble in the field enables call (913) 621-3700.
facility expansion
B. Design:
I. Tank Designed in Accordance with: AWWA D103-97
II. Seismic Design: AWWA D103-97
III. Seismic Zone: 4
IV. S (Site Amplification Factor): 1.5
V. I (Use Factor): 1.25
VI. RW (Force Reduction Coefficient): 3.5
VII. Wind Design: AWWA D103-97
VIII. Wind Speed: 100 (MPH) - 161 (KPH)
IX. Roof Design: CTT Standard Design
X. Live Load (psf): 25
XI. Roof Design (Snow/Live) Load (psf): 25
XII. Internal Tank Design Pressure: 2Oz./Sq. In.
XIII. Internal Tank Design Vacuum: 0.5Oz./Sq. In.
C. Coating:
I. Coating: OptiBond™ Epoxy Coating Process
Electro-statically applied over a minimum SSPC-SP 10 near-white blast and thermally cured
II. Interior and both sides of bottom painted Trico Bond EP™ (7 mils average, DFT)
III. Exterior Primer: Trico Bond EP™ (3 mils average, DFT)
IV. Exterior Finish Coat: Performance Urethane (1.5 mils average, DFT)
V. Exterior Color: Will Advise
D. Hardware:
I. Galvanized bolts, nuts, and washers
II. Plastic encapsulated head bolts for interior vertical and roof seams
III. Encapsulated nuts for all floor seams
F. Accessories:
I. 1 - Partial Deck Perimeter Guardrail (5' Each Side of Ladder)
II. 2 - 24" X 46" (610mm X 1168mm) Flush Cleanout w/ 2-Piece Cover
III. 1 - CST Storage Decal Installed on Top Ring
IV. 1 - Nameplate, Liquid Tank
V. 1 - 3" (80 mm) INLET - 150# Raised Face Slip On Single Flanged Nozzle - Inlet
VI. 1 - 4" (100 mm) 150# Raised Face Slip On Single Flanged Nozzle - Drain
VII. 1 - 4" (100 mm) Suction Nozzle with Elbow and Vortex Breaker - Suction
VIII. 1 - 4" (100 mm) Overflow w/ Internal Weir Cone and External Flanged Nozzle - Overflow
IX. Asphalt-Impregnated Fiberboard - Full Bottom Area
XI. 1 - 24" (610mm) Square Roof Manway With Hinged Cover
XII. 4 mil Polyethylene
XIII. Electronic Tank Calculations (Approvals and Finals)
A Storage Legacy Exceptional design capabilities have given CST a reputation as the most innovative storage
manufacturer in the world. With our proven engineering capabilities and design standards, CST offers
Peabody TecTank unrivaled expertise as the world’s first manufacturer of bolted liquid and dry bulk storage tanks and silos to:
The business roots for CST Industries run deep –
Receive API-12B Monogram (Parsons, KS Facility - License No. 12B-0004)
all the way back to 1893 following our heritage as ®
Design FM Approved and composite elevated bolted tanks
Columbian Steel Tank Company TM, Peabody TecTank Provide a proof load tested jacking system designed by licensed engineers to ensure construction safety
Apply bolted technology to large scale quick assembly frac water tanks
and Columbian TecTank®. Apply bolted tanks to SAGD oil field applications
Apply bolted tanks to slurry applications
CST introduced the first bolted steel storage tanks for the petroleum industry and Design and build the world’s largest externally supported bolted pressurized roof at 137 ft. (42 m)
initiated the widely utilized API-12B standard implemented in 1929. The API-12B Apply build gaskets to bolted tanks
standard is still featured in CST’s TecTank™ storage systems today. Suspended aluminum decks for cryogenic service per API 620 and EN 14620
In the 1940s, CST initiated jacking tanks on grain bins and silos for the
With a legacy of 125 years and over 350,000 field proven storage tank installations
agriculture market. Additionally, CST has designed silos with drive-
in more than 125 countries, no other company can match CST’s world-renowned
through skirts for railcar loadout and tanks with unique hoppers. We
brands, premium engineered designs, world-class manufacturing
have even designed tanks with office space under the hopper bottom.
or construction experience. CST is the world’s leading and largest dome manufacturer and has
installed the longest clear-span aluminum truss in the world at 291 ft.
(89 m) long and the largest clear-span aluminum dome in the world at 443 ft. (135 m) diameter. CST has installed over
18,000 aluminum covers worldwide. The company developed the center tower erection methodology for safe, efficient
Highest Quality – Promised and Delivered – assembly and lifting of large domes.
in Tanks for Liquid Applications Our integrated project team works with you to ensure your tank is designed to yield the best lifelong value for your
application. Factors such as capacity, seismic conditions, specific gravity and wind loading vary widely from one
Our commitment to performance is delivered through time-proven design and application to the next. The draftsmen and licensed professional engineers in our Engineering and Design Department
engineering, our precision manufacturing technologies, and our commitment give individual consideration to every tank and silo. With our staff and consultants, drawings can be supplied with the PE
to excellence in installation. All CST operations are ISO 9001:2015 Certified. seal from any state, territory or province. CST offers more FM pre-approved models than any other storage provider.
Trico Bond EP® precision-applied powder coating with high Trico Bond EP®, precision-applied powder coating with high Panel coating not applicable. Exterior coated pieces are
performance urethane topcoat for additional protection and UV performance urethane topcoat for additional protection and 2 mil (50 μm) to 3 mil (75 μm) standard epoxy coating.
PANEL COATING EXTERIOR resistance at 3.5 mil (85 μm) to 5 mil (130 μm) average dry film UV resistance at 3.5 mil (85 μm) to 5 mil (130 μm) average 1.5 mil (35 μm) to 3 mil (75 μm) high performance urethane
thickness. (Unlimited topcoat color options) dry film thickness. (Unlimited topcoat color options) for additional protection and UV resistance.
Trico Bond EP® up to 140° F (60° C) Trico Bond EP® up to 140° F (60° C)
OPERATING TEMPERATURES Trico Bond SD™ up to 200° F (93° C) Trico Bond SD™ up to 200° F (93° C) Standard coating up to 140° F (60° C)
NSF 61 Approved NSF 61 Approved
18,000 lb (8164.66 kg) hydraulic actuated, synchronized jack Delivered in one piece on specialized equipment, ready for
Third party safety PE stamped scaffold system. Fastest
FIELD INSTALLATION system third party proof load tested and PE stamped. Fastest lift and place on prepared foundation (by others).
bolted installation for tanks 24 ft. (7 m) tall or less.
bolted installation for tanks greater than 24 ft. (7 m). Fastest installation.
AGE OF COMPANY & “YEARS Established in 1893. More tank and employee experience
OF EXPERIENCE” than the next two competitors combined.
CST employed or exclusive subcontract crews using third CST employed or exclusive subcontract crews using
Typically by others - Ask your CST Manufacturers’
FIELD CONSTRUCTION party safety certified & PE stamped scaffold design. third party safety certified & PE stamped scaffold design.
Representative for recommendations.
*Most experienced crews. *Most experienced crews.
Up to 1/2 in. (1 cm) thick. Available in carbon steel, aluminum Up to 5/16 in. (0.8 cm) thick. Available in carbon steel, Up to 1/2 in. (1 cm) thick. Available in carbon steel,
PLATE THICKNESS
and 304/316 grades of stainless steel. aluminum and 304/316 grades of stainless steel. aluminum and 304/316 grades of stainless steel.
World-Renowned TecTank ®
Flat Panel Tank Systems Flat panel tanks are typically assembled from the top down
by using a hydraulic actuated, synchronized jacking system
TecTank Flat Panel was engineered and developed for that is third party proof load tested and PE stamped.
higher volume needs. The flat panel design offers a These tanks are most often built by factory-trained building
significant increase in liquid storage capacity. crews who specialize in jacking system construction.
Like CST’s chime panel design, CST’s flat panel liquid storage
First ring of panels and roof are safely
tanks may be used in high-volume industrial, commercial,
constructed at ground level
institutional, and private applications to store water,
wastewater and many other liquid materials. The flat panel Tank is jacked up and successive
is a jack-built design that can accommodate capacities over rings are constructed
6,000,000 gal. (22,712m3).
The final ring is constructed and tank
CST flat panel tanks are processed with the OptiBond is lowered onto foundation ring
coating process featuring the Trico Bond EP or SD epoxy
powder, offering the best in corrosion resistance.
CST’s chime panel tanks and silos are field constructed First ring of panels is constructed
by CST crews utilizing our third party safety certified directly on the foundation
& PE stamped scaffold design. TecTank Chime Panel
bolted storage tanks are: Successive rings are constructed in
place on lower rings
er or
Features factory formed flanges at horizontal seams Roof or cover can be built in place or
wat
aste e’ve
for added panel rigidity on the ground and placed by crane
er, w
Gasketed joints allow for a broad application range
it ’s wat liquids, w
If strial vered!
API-12B monogram available
in du co
got it
Storage Tank Options
Tank Applications
CST can design and build storage tanks with all the options and accessories to match specifications.
Our diverse experience in building all types of tanks for different applications helps us devise practical
solutions to meet operational requirements. Ordering a tank with additional integrated accessories
and services drastically reduces time and expense. This allows customer management to focus on
CST’s TecTank product line delivers high-quality and durability more important aspects of the project.
at the best value per gallon, making TecTank tank systems
the best choice for liquid storage applications. Foundation and Floor Designs
Foundation designs are done in-house and are customized to customer needs and storage application.
Water CST understands that different storage applications require different foundation and floor options. That is
why CST offers choices for the customer depending on their needs. Customers can select floors from
Potable Water Fire Protection Salt Water Coated Steel (Vitrium™ Glass or OptiBond™ Epoxy), or sealed and unsealed reinforced concrete.
Raw Water Storage Distilled Water Brines Water
Irrigation Water Deionized Water Brackish Water
Disinfection Demineralized Water Desalinization
Wastewater
Landfill Leachate Anaerobic & Aerobic Digestion Primary & Secondary Containment
Storm Water Run-off Sludge Storage Sedimentation
Flocculation Disinfection Aeration
Trickling Filters Flow Equalization Biological Oxidation Embedded Starter Modified Starter Anchored to Slab Foundation
Used for larger municipal and Combines Embedded Starter Tanks are anchored to slab with
industrial applications and higher for large tank and higher anchor bolts around perimeter
Industrial Liquids and Chemicals
seismic applications seismic features
Fertilizer Lime & Carbonate Slurry Mining Fluids & Slurry
Insecticides Secondary Containment De-Icer
Food Waste Edible Oils Dyes & Pigments
Food Additives Paints & Primers Pulp & Paper Processing
Glycols Detergents
Capacity Specifications:
Accessories
Petrochemical
Alfreton, England
CST is committed to providing its customers with the highest engineered quality, best
service, longest product life and greatest value for every storage solution we supply.
Contact CST for all your liquid storage needs.
CST Industries, Inc. | 903 E. 104th Street, Suite 900 | Kansas City, MO 64131 USA | Ph: +1 844-44-TANKS | Fax: +1 913-621-2145