Sheet No

PROJECT MELAKA 30 MLD


1
PROPOSAL Title : RAW WATER PIPE
Designed By: HADI Date: 17-Jul-24
Checked By: HADI Date: 17-Jul-24
Ref: Design Calculations Output:
PUMP 8

Reservoir Hs = 1.5 m
TWL
4 m L= 200 m
TWL 3.554 D= 700 mm

TWL 4.28

TASIK 1

BWL 2.28

SG. CHOHONG

TWL
2.5 m
Capacity Supply 32 MLD
Flow , Q 0.4667 m3/s 1680.0 m3/hr
Pipe Size, D 700 mm
Hazen william, C 110
Pipe Length, L 200 m

Velocity =Q/A = 1.21 m/s

1.85
Hf = 10.67 x (1.1 L) Q
D^4.875 C

= 0.55 m

Total head = Hf + HS + 1.5


HT = 3.55 m

Shaft power = 9.81 x Q x HT


Eff
= 23.19 kW Pump eff: 70%

Input power = Shaft power / motor eff Motor eff : 92%


= 25.20 kW

Rated = 1.15 x Input Power


= 28.98 kW >180kW required HT supply for all