NOTE: A NOTE indicates important information that helps you make better use of your product.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2017 - 2019 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other
trademarks may be trademarks of their respective owners.
2019 - 04
Rev. A03
Contents
1 Product overview........................................................................................................................................... 6
Target market..................................................................................................................................................................... 6
Product positioning............................................................................................................................................................ 6
Product features.................................................................................................................................................................7
Product comparison...........................................................................................................................................................7
Supported operating systems...........................................................................................................................................8
System information label................................................................................................................................................... 9
Sled service information.............................................................................................................................................. 9
Cable routing............................................................................................................................................................... 10
Mechanical overview.................................................................................................................................................. 11
Link board and Drive cage......................................................................................................................................... 12
Jumper settings.......................................................................................................................................................... 12
System tasks............................................................................................................................................................... 13
Contents 3
System board diagnostic LED indicators.................................................................................................................36
Disassembly and reassembly.......................................................................................................................................... 36
Dell EMC PowerEdge C6420 sled........................................................................................................................... 36
Drives........................................................................................................................................................................... 41
Power supply units.....................................................................................................................................................45
System cover..............................................................................................................................................................47
Backplane cover.........................................................................................................................................................48
Cooling fans ...............................................................................................................................................................50
Power interposer board.............................................................................................................................................53
Chassis management board..................................................................................................................................... 56
Linking board.............................................................................................................................................................. 58
Midplane...................................................................................................................................................................... 61
Drive cage...................................................................................................................................................................65
Backplanes and expander board.............................................................................................................................. 69
Control panel...............................................................................................................................................................73
Thermal sensor board................................................................................................................................................ 76
Entering the system Service Tag by using System Setup...........................................................................................78
Installation......................................................................................................................................................................... 78
Rack rails..................................................................................................................................................................... 78
Accessing system information by using QRL.......................................................................................................... 81
4 Technical specifications..............................................................................................................................100
Dimensions of the Dell EMC PowerEdge C6400 enclosure...................................................................................... 101
Chassis weight.................................................................................................................................................................101
PSU specifications......................................................................................................................................................... 102
Chassis management board specifications................................................................................................................. 102
Drives and storage specifications.................................................................................................................................103
Midplane specifications................................................................................................................................................. 104
Environmental specifications........................................................................................................................................ 104
Standard operating temperature specifications....................................................................................................104
4 Contents
Expanded operating temperature specifications ..................................................................................................113
Particulate and gaseous contamination specifications......................................................................................... 115
Maximum vibration specifications........................................................................................................................... 116
Maximum shock specifications................................................................................................................................116
Maximum altitude specifications............................................................................................................................. 116
Fresh Air Operation................................................................................................................................................... 117
6 Documentation resources...........................................................................................................................120
Contents 5
1
Product overview
The PowerEdge C6400 is a 2U rack mounted chassis that supports up to four independent PowerEdge C6420 sled servers.
Topics:
• Target market
• Product positioning
• Product features
• Product comparison
• Supported operating systems
• System information label
Target market
The PowerEdge C6400 chassis is designed to support the capabilities of the C6420 sleds which include high-performance computing
fields-technical computing, scientific research, oil and gas exploration, financial services, and medical imaging. Other target workloads for
the C6420 include web scale applications-SaaS and IaaS, High Performance Data Analytics (HPDA), Financial and High Frequency Trading
(HFT), and Hyper Converged Infrastructure (HCI)-vSAN and Private Cloud.
Product positioning
The PowerEdge C6400 is positioned to accommodate high-level enterprise businesses at all sizes. The 2U chassis supports up to four 1U
nodes-PowerEdge C6420 sled servers, which is suitable for High Performance Computing (HPC) and hyper converge solutions.
6 Product overview
Product features
Table 1. C6400 features
Feature Description
Drive Bays
• Up to 12 x 3.5-inch hard drive backplane configuration-SAS/
SATA
• Up to 24 x 2.5-inch hard drive backplane configuration-SAS/
SATA/NVMe
• Up to 24 x 2.5-inch hard drive backplane with expander board
configuration
• No hard drive configuration
Form factor 2U
Supported server sled PowerEdge C6420
Rack rails Static rails only
Dimension 482.6 mm (19-inches) x 797.3 mm (31.38-inches) x 86.8 mm (3.41-
inches)
Weight
• 24 x 2.5-inch hard drive chassis: 41.46 kg (91.40 lb)
• 12 x 3.5-inch hard drive chassis: 43.62 kg (96.16 lb)
• No backplane systems: 34.56 Kg (76.19 lb)
Product comparison
Table 2. Comparison table
Form factor 2U 2U
Product overview 7
Feature C6400 C6300
Supported server PowerEdge C6420 PowerEdge C6320p or C6320
sled
Rack rails Static rails only Static rails only
Dimension 482.6 mm (19-inches) x 797.3 mm (31.38-inches) x 86.8 790.3 mm mm x 448 mm x 86.8 mm
mm (3.41-inches)
Weight
• 24 x 2.5-inch hard drive chassis: 41.46 kg (91.40 lb) • 24 x 2.5-inch hard drive chassis: 41.0 kg or 90.4lbs
• 12 x 3.5-inch hard drive chassis: 43.62 kg (96.16 lb) • 12 x 3.5-inch hard drive chassis: 41.0 kg or 90.4lbs
• No backplane systems: 34.56 Kg (76.19 lb) • Empty chassis: 15.1 kg or 33.3 lbs
Supported USB
• USB key (bootable) • USB key (bootable)
peripherals on the
sled • Keyboard (only one USB keyboard) • Keyboard (only one USB keyboard)
• Mouse (only one USB mouse) • Mouse (only one USB mouse)
NOTE: For more information about the specific versions and additions, see https://www.dell.com/support/home/drivers/
supportedos/poweredge-c6400
8 Product overview
System information label
Sled service information
Product overview 9
Cable routing
10 Product overview
Mechanical overview
Product overview 11
Link board and Drive cage
Jumper settings
12 Product overview
System tasks
Product overview 13
2
Field service information
The information in this section is designed specifically for field service personnel who perform installation, diagnosis, and repair activities.
Field personnel are required to know the information and procedures in this section whether or not they perform all the service tasks.
NOTE: Information in this section is required knowledge, but should never override regional or local policy and procedure.
Topics:
• Product overview – High-level description of the system that includes features and functions, product-to-product comparison, and
supported operating systems, if applicable, and OEM branding information.
• Safety precautions – Generic safety precautions for every service event.
• Tools and utilities – Hand tools, diagnostic tools or utilities, software applications, or GUIs that are required to service the system.
• Need to know - Specific callouts about the system, common error codes, version control for BIOS, firmware, or software for OEM,
required startup or shutdown sequence, new product technologies or components comparison.
• Diagnostics and indicators – Visual information about the health and state of the system.
• System board connectors – Information on system board connectors.
• System board jumper settings – Information on system board jumper settings.
• Disassembly and reassembly – Instructions for removing and replacing each replaceable part, with information needed before, during,
and after parts replacement.
• Installation – Includes information about rack rails.
Chassis Overview
The following section contains images and information about the front panel, back panel, and inside the system.
NOTE: For more information about sled installation sequence, see Sled installation guidelines.
Safety precautions
Follow the safety precautions that are described in the following sections during an installation or a disassembly/reassembly procedure:
Standby power
When applicable Dell products that feature a standby power mode, must be unplugged before the system is serviced.
NOTE: Systems that incorporate standby power, continue to use power even when they are powered off. For example, standby
power enables the system to be powered on remotely with the wake on LAN feature enabled, suspended into sleep mode, or
other advanced power management features.
After you unplug a system and before you remove components, wait approximately 30 to 45 seconds to allow the charge to drain from the
circuits.
Bonding
Bonding is a method of connecting two or more grounding conductors to the same electrical potential. This method requires the Field
Service ESD kit. When connecting a bonding wire, always ensure that it is connected to a bare metal system and never to a painted or
nonmetal surface. The Wrist Strap should be secured to your skin. Ensure that you remove all jewelry such as watches, bracelets, or rings
before bonding yourself and the equipment.
Electrostatic discharge
Electrostatic discharge (ESD) is a major concern when you handle sensitive components such as expansion cards, processors, memory
DIMMs, and system board. A slight charge can result in damaging the circuits on these components causing intermittent problems or
shortening the life span.
Due to the increased density of semiconductors that are used in recent Dell products, the sensitivity to static damage is now higher than in
earlier Dell products. For this reason, some previously approved methods of handling parts are no longer applicable.
There are two recognized types of ESD damage: catastrophic and intermittent failures.
• Catastrophic—The damage causes an immediate and complete loss of device functionality. For example, a memory DIMM that has
received a static shock, immediately generates a No POST/No Video symptom.
NOTE: Intermittent failures represent approximately 80 percent of ESD-related failures. The high rate of intermittent
failures means that most of the time when damage occurs, it is not immediately recognizable.
Intermittent or latent failures are difficult to identify and troubleshoot. The image shows an example of damage to a memory module trace.
Although the damage is complete, the symptoms may not become an issue or cause permanent failure for some time after the damage
occurs.
• Handle all static-sensitive components in a static-safe area. If possible, use antistatic floor pads and workbench pads.
• Grasp the static-sensitive components by the side and not the top.
• Avoid touching the pins and circuit boards.
• Do not remove components from the antistatic packing material until you are ready to install the components. Before unwrapping the
antistatic packaging, be sure to discharge static electricity from your body.
• Place the component in an antistatic container or packaging before transporting the components.
• Antistatic mat
• Wrist Strap
• Bonding wire
The antistatic mat is dissipative and must be used to safely place parts on during service procedures. When using an antistatic mat, your
Wrist Strap must be snug, connected to the mat, and to the bare-metal on the system that is being worked on. After the mat and Wrist
Strap are deployed properly, remove the components to be serviced form the ESD bag and place them on the mat. Remember, the only
safe place for ESD-sensitive items are in your hand, on the ESD mat, in the system, or inside a bag.
The Wrist Strap and bonding wire can be connected either to:
NOTE: The physical connection of the Wrist Strap and bonding wire between your skin, the ESD mat, and the hardware is known
as bonding.
NOTE: Use only Field Service kits with a Wrist Strap, mat, and bonding wire. Avoid using wireless Wrist Straps.
The internal wires of a Wrist Strap are prone to damage from normal wear and tear, and must be checked regularly with a Wrist Strap
tester to avoid accidental ESD hardware damage. Dell recommends to test the Wrist Strap and bonding wire regularly.
Look for a large open flat work area that is free of clutter and large enough to deploy the ESD kit with more space to accommodate the
type of system that is being repaired. The workspace should also be free of insulators that can cause an ESD event. On the work area,
insulators such as Styrofoam and other plastics must be moved at least 12-inches or 30 centimeters away from sensitive parts before
physically handling any hardware components.
ESD packaging
All ESD sensitive devices must be shipped and received in static-safe packaging. Preferably, metal, static-shielded bags. Ensure that you
return the damaged parts in the same ESD bag or packaging in which the new part arrived in. The ESD bag should be folded over and
taped shut, and the foam packing material used in the original box must be used.
ESD sensitive devices should be removed from packaging only at an ESD protected work surface, and parts should never be placed on top
of the ESD bag because only the inside the bag is shielded. Always place parts in your hand, on the ESD mat, in the system, or inside an
antistatic bag.
Lifting equipment
WARNING: Do not lift systems that are greater than 50 pounds. Always obtain assistance, or use a mechanical lifting device.
1 Get a firm balanced footing. Keep your feet apart for a stable base, and point out your toes.
2 Bend your knees. Do not bend at the waist.
Recommended tools
Table 4. Recommended tools and optional tools
• Key to the bezel lock • Needle-nose pliers to disconnect cables and connectors in
The key is required only if your system includes a bezel. hard-to-reach locations
• Phillips #1 and #2 screwdriver • Small flat-head screwdriver to disconnect small cables from
boards
• 1/4 inch flat blade screwdriver
• 5mm hex nut screwdriver
• Torx #T30 screwdriver
• Wrist-grounding strap connected to the ground
• ESD Mat
Need to know
Before you begin servicing the system, you must read the following information:
• Critical callouts
• Common error codes
• Version control for BIOS/firmware/software
• Startup/Shutdown Sequence
NOTE: Replace ATXXXXXXX with the new number for the asset tag.
NOTE: Systems with Windows operating system uses the .bat file, while Linux based operating system uses the .sh file.
• BackupProp.sh - A bash script for Linux or Windows (uses .bat file format). This script backs up the Chassis Manager properties to a
configuration file. This script does not take any argument. Just run the script from the current directory. It creates the backup file in
current directory. The script has default iDRAC IP address, username and password in the beginning of the file. To change the default
values, please edit the BackupProp.sh file and change the necessary fields at the top of the file. It only stores the following properties:
Chassis service tag, backplane present info, and FTR setting.
• RestoreProp.sh - A bash script for Linux or Windows (uses .bat file format). This script restores the value of the properties that are
saved in the configuration file by BackupProp.sh. This script does not take any argument. Just run the script from the current directory.
The script has default iDRAC IP address, username and password in the beginning of the file. To change the default values, please edit
the RestoreProp.sh file and change the necessary fields at the top of the file. It only stores the following properties: Chassis service tag,
backplane present info, and FTR setting.
1 IPMITool- The backup and restore scripts use IPMITool to communicate with iDRAC to get or set the properties. Make sure that
IPMITool is installed in your system. Users can download them from the source below:
NOTE: Ensure that the CMC firmware and IPMI tool are updated to the latest version.
ipmitool -I lanplus -H <ip_address> -U <username> -P <password> raw 0x6 0x34 0x45 0x70 0xc0
0xc8 0x20 0x0 0xa0 0x0 0x01 0x1b 0xd8
ipmitool -I lanplus -H <ip_address> -U <username> -P <password> raw 0x6 0x34 0x45 0x70 0xc0
0xc8 0x20 0x0 0xa1 0x1 0x1 0x1b 0x01 0xd8
• FTR feature setting:
– Get:
ipmitool -I lanplus -H <ip_address> -U <username> -P <password> raw 0x6 0x34 0x45 0x70 0xc0
0xc8 0x20 0x0 0xa0 0x0 0x01 0x1a 0xd8
– Set (The second last byte is the FTR setting. Use 0x01 if the FTR is enabled and 0x00 if FTR is disabled. The example below has
FTR enabled):
ipmitool -I lanplus -H <ip_address> -U <username> -P <password> raw 0x6 0x34 0x45 0x70 0xc0
0xc8 0x20 0x0 0xa1 0x1 0x1 0x1a 0x00 0xd8
• Chassis service tag:
– Get:
ipmitool -I lanplus -H <ip_address> -U <username> -P <password> raw 0x30 0xC8 0x01 0x00 0x0c
0x00 0x00 0x00 0x00
– Set (The last 8 bytes are the Chassis Service Tag. The values are expected to be in Hex format. Please use any standard ASCII to
HEX converter tool to convert any string to Hex format):
ipmitool -I lanplus -H <ip_address> -U <username> -P <password> raw 0x30 0xC8 0x0 0x00 0x0c
0x00 0x00 0x00 0x0c 0x0 0x11 0x08 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x42
Figure 27. Drive indicators on the drive and the mid drive tray backplane
NOTE: If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not turn on.
NOTE: The drive status indicator remains off until all drives are
initialized after the system is turned on. Drives are not ready
for removal during this time.
Flashes green, amber, and then turns off Predicted drive failure.
Flashes green for three seconds, amber for three seconds, and Rebuild stopped.
then turns off after six seconds
NOTE: The 2400 W and 2000 W PSUs use a C19 or C20 connector. The 1600 W PSUs use a C13 or C14 connector.
Blinking green When the firmware of the PSU is being updated, the PSU handle blinks green.
CAUTION: Do not disconnect the power cord or unplug the PSU when updating firmware. If
firmware update is interrupted, the PSUs do not function.
Blinking green and turns off When hot-plugging a PSU, the PSU handle blinks green five times at a rate of 4 Hz and turns off. This
indicates a PSU mismatch with respect to efficiency, feature set, health status, or supported voltage.
CAUTION: The PSUs must have the same type of label; for example, Extended Power
Performance (EPP) label. Mixing PSUs from previous generations of PowerEdge servers is not
supported, even if the PSUs have the same power rating. This results in a PSU mismatch
condition or failure to turn the system on.
CAUTION: When correcting a PSU mismatch, replace only the PSU with the blinking indicator.
Swapping the PSU to make a matched pair can result in an error condition and unexpected
system shutdown. To change from a high output configuration to a low output configuration or
vice versa, you must turn off the system.
CAUTION: AC PSUs support both 240 V and 120 V input voltages with the exception of Titanium
PSUs, which support only 240 V. When two identical PSUs receive different input voltages, they
can output different wattages, and trigger a mismatch.
CAUTION: If two PSUs are used, they must be of the same type and have the same maximum
output power.
Green Off BMCiDRAC critical condition event in Power Off mode (S4/S5)
Amber Blinking
Green Off BMCiDRAC critical condition event in Power On mode (S0)
Amber BlinkingOn
System identification indicator Steady blue IPMI using Chassis Identify Command On or ID Button Press ID
On
Status Condition
Link and activity indicators are off. The NIC is not connected to the network.
Link indicator is green, and activity indicator is blinking The NIC is connected to a valid network at its maximum port speed, and
green. data is being sent or received.
Link indicator is amber, and activity indicator is blinking The NIC is connected to a valid network at less than its maximum port
green. speed, and data is being sent or received.
Link indicator is amber, and activity indicator is off. The NIC is connected to a valid network at less than its maximum port
speed, and data is not being sent or received.
Link indicator is blinking green, and activity is off. NIC identify is enabled through the NIC configuration utility.
NOTE: For optimized thermal operation, ensure to follow the sled population sequence mentioned below:
Removing a sled
Press the retaining latch and using the sled pull handle, slide the sled out of the enclosure horizontally, ensuring that the sled is
supported from beneath.
Installing a sled
Prerequisite
Step
Slide the sled into the enclosure horizontally, ensuring that the sled is supported from beneath until it locks into place.
Drives
Press the release button, and slide the drive blank out of the drive slot.
Insert the drive blank into the drive slot, and push the blank until the release button clicks into place.
CAUTION: To prevent data loss, ensure that your operating system supports drive installation. See the documentation
supplied with your operating system.
Steps
1 Press the release button to open the drive carrier release handle.
2 Holding the handle, slide the drive carrier out of the drive slot.
1 Disconnect the power cable from the power source and from the PSU you intend to remove, and then remove the cable from the
strap on the PSU handle.
Step
Press the release latch and slide the PSU out of the system by using the PSU handle.
Next step
1 Connect the power cable to the PSU, and plug the cable into a power outlet.
CAUTION: Secure the power cable to the PSU with the strap provided on the PSU handle.
Steps
1 Press and hold the cover release latch lock down.
2 With your palm on one of the traction pads, slide the system cover toward the rear of the system.
3 Lift the cover from the system.
Backplane cover
Steps
1 Using the Phillips #1 screwdriver, remove the screws that secure the backplane cover to the enclosure.
2 Slide the backplane cover toward the back of the enclosure and lift the cover away.
Step
Disconnect the fan cable from the connector on the cooling fan cage and lift the fan out.
Next step
1 Check the management software to see if the fan is rotating at the optimal speed.
NOTE: Observe the routing of the cables when removing them from the system. Route these cables properly when you replace
them to prevent the cables from being pinched or crimped.
Steps
1 Disconnect the fan power cable from the chassis management board.
2 Lift the cooling fan cage out of the chassis.
NOTE: Observe the routing of the cables when removing them from the system. Route these cables properly when you replace
them to prevent the cables from being pinched or crimped.
Steps
1 Align the guide pins on the cooling fan cage with the guide holes on the chassis.
2 Install the fan cage onto the chassis, and push until it is firmly seated on the guide holes.
3 Connect the fan power cable to the connector on the chassis management board.
To prevent the cable from being damaged, route this cable properly.
Next steps
Steps
1 To release the PIB from the lock on the chassis, pull the blue release latch.
2 Holding the release latch, lift the PIB up and away from the guide hooks on the chassis.
3 Using the Phillips #2 screwdriver, remove the screws that secure the mid-plane power cables to the PIB.
Figure 52. Removing the midplane power cables from the PIB
2 Align and insert the PIB on the guide hooks on the chassis.
3 Push the PIB down to secure it with the lock on the chassis.
Next steps
Steps
1 Using the Phillips #2 screwdriver, remove the two screws that secure the chassis management board to the chassis.
2 Sliding the board toward the front of the enclosure, lift the board away after the guide slots are free of the standoffs.
Linking board
Removing the linking board
Prerequisites
Steps
1 Using the Phillips #1 screwdriver, remove the screw that secures the linking board to the enclosure.
2 Lift the linking board out of the enclosure.
3 Disconnect all the attached cables.
NOTE: Ensure that the linking board cable connector is not folded or twisted while installing the sled, to avoid damaging
the linking board cable connector.
3 Using a Phillips #1 screwdriver, replace the screw on the linking board to secure the board in place.
Next steps
Steps
1 Using the Phillips #1 screwdriver, remove the screws that secure the midplane to the chassis.
2 Lift the midplane out of the chassis.
3 Using the Phillips #1 screwdriver, remove the screws that secure the power cables to the midplane.
Next step
Steps
1 Using the Phillips #1 screwdriver, connect and secure the power cables to the midplane.
2 Place the midplane into the chassis.
3 Using the Phillips #1 screwdriver, tighten the screws that secure the midplane to the chassis.
Next steps
Next step
Steps
1 Using the Phillips #1 screwdriver, connect and secure the power cables to the midplane.
2 Place the midplane into the chassis.
3 Using the Phillips #1 screwdriver, secure the midplane to the chassis with the screws.
Next steps
Figure 65. Midplane power cable routing from power interposer board
Drive cage
Removing the 2.5 inch drive cage
Prerequisites
CAUTION: To prevent damage to the drives and backplane, you must remove the drives from the system before removing the
backplane.
CAUTION: You must note the number of each drive and temporarily label them before removal so that you can replace them in
the same locations.
NOTE: Observe the routing of the cables on the chassis as you remove them from the system. You must route these cables
properly when you replace them to prevent the cables from being pinched or crimped.
Steps
1 Using the Phillips #1 screwdriver, remove the screws that secure the drive cage to the chassis.
2 Slide the drive cage to the unlock position.
3 Lift the drive cage away from the enclosure.
Next step
Next steps
1 If applicable, reconnect all the cables that were disconnected from the linking board and chassis management board.
2 Install the removed drives.
3 Install the fan cage.
4 Install the backplane cover.
Steps
1 Using the Phillips #1 screwdriver, remove the screws that secure the drive cage to the chassis.
2 Slide the drive cage to the unlock position.
3 Hold and lift the drive cage up.
4 Lift the drive cage away from the enclosure.
Next step
Next steps
1 Reconnect all the backplane cables that were disconnected from the linking board and chassis management board.
2 Install all the drives.
3 Install the fan cages.
Steps
1 Orient the drive cage so that the drive bays are facing down.
2 Using the Phillips #2 screwdriver, remove the screws that secure the backplane to the drive cage.
3 Lift the backplane away from the drive cage.
Next step
Next steps
Next step
Steps
1 Install the backplane expander board into the enclosure, aligning the screw holes on the board with the holes on the drive cage.
2 Using the Phillips #2 screwdriver, secure the backplane expander board to the chassis.
Next steps
Control panel
Removing the control panel
Prerequisites
NOTE: Observe the routing of the cables on the enclosure as you remove them. You must route these cables properly when you
replace them to prevent the cables from being pinched or crimped.
Steps
1 Using the Phillips #1 screwdriver, remove the screws that secure the control panel assembly to the enclosure.
2 Remove the cable from the cable retention clips.
3 Lift the control panel assembly away.
Next step
Steps
1 Route the control panel cable through the cable retention clips.
2 Install the control panel assembly and secure it in place with screws.
Next steps
Steps
1 Using the Phillips #1 screwdriver, remove the screw that secures the thermal sensor board assembly to the drive cage.
2 Disconnect the cable from the sensor board assembly.
Next step
Next steps
1 Replace the drive cage into the chassis.
2 Connect all the cables to the backplane.
3 Connect the control panel cables to the midplane.
4 Install the drives.
NOTE: You can enter the Service Tag only when the Service Tag field is empty. Ensure that you enter the correct
Service Tag. After the Service Tag is entered, it cannot be updated or changed.
5 Click OK.
6 Import your new or existing iDRAC Enterprise license.
For more information, see the Integrated Dell Remote Access Controller User's Guide at Dell.com/idracmanuals.
Installation
The sections below contains information about installation procedures of the enclosure into the rack rails.
Rack rails
The rail offerings consist of the static rails only.
The static rails do not support serviceability in the rack and are thus not compatible with the CMA.
One key factor in selecting the proper rails is identifying the type of rack in which they are installed. The static rails support tool-less
mounting in 19” wide, EIA-310-E-compliant square hole and unthreaded round hole 4-post racks. It also support tooled mounting in
threaded hole 4-post racks and mounting in 2-post-Telco racks.
NOTE: Screws are not included in either kit because threaded racks are offered with various thread designations. Users must
therefore provide their own screws when mounting the rails in threaded racks.
Other key factors governing proper rail selection include the following:
• Spacing between the front and rear mounting flanges of the rack
• Type and location of any equipment mounted in the back of the rack such as power distribution units (PDUs)
• Overall depth of the rack
The static rails offer a greater adjustability range and a smaller overall mounting footprint than the sliding rails. This feature is due to their
reduced complexity and lack of need for CMA support.
1 Install the optional chassis retention bracket and insert two cage nuts in the two rack holes above the rail.
NOTE: If the system is a 1U system, the optional chassis retention brackets cannot be installed.
NOTE: The cage nuts must be installed before installing the system in the rack.
2 Position the system on the rail.
3 Hold the system rack ears and slide the system into the rack until the system is seated in place.
4 Tighten the thumbscrews to secure the system.
Figure 81. Diagram and description of installing the system into the rack
Figure 82. Diagram and description of installing the optional chassis retention bracket
• How-to videos
• Reference materials, including the Installtion and Service Manual, and mechanical overview
• Your system service tag to quickly access your specific hardware configuration and warranty information
Steps
1 Go to Dell.com/qrl and navigate to your specific product or
2 Use your smartphone or tablet to scan the model-specific Quick Resource (QR) code on your system or in the Quick Resource
Locator section.
Figure 83. Quick Resource Locator for PowerEdge C6400 and C6420 systems
Topics:
• System fan
• Linking board
• Backplane
• Power interposer board
• Midplane board
• Chassis Management board
• Power supplies
System fan
The PowerEdge C6400 systems support four 60-mm high-efficiency fans mounted in a fan assembly. The fan assembly is located in the
chassis between the hard drive bay and server sleds. Each fan has a power connector located near the fans allowing easy access to the fan
cable. These fans are not hot-swappable.
NOTE: The arrows are steps to remove the cooling fan. Remove the cooling fan cable first, and then lift the cooling fan from the
cooling fan assembly.
Linking board
The PowerEdge C6400 supports two linking boards used to bridge the sled server and chassis. It bypass SATA and PCIe signals from the
system board to the hard drive backplane. One linking board can support two sleds. There are two linking boards in a chassis to support
four sleds. There are two types of Linking Board, one supports both SATA/SAS and PCIE (DPN: MP84G) , one only supports SATA/
SAS(DPN: VNFMF). Both of them share same PCB. The dimension of the linking board is 73.2 mm x 46.6 mm.
Figure 85. Linking board with SATA/SAS and PCIe support Figure 86. Linking board with
SATA/SAS support
Backplane
The following pages contain information about the backplane and middle plane connectors.
NOTE: SGPIO features will only be available on all passive backplanes at Quarter 4 2017's firmware release.
The image below shows the 24 x 2.5-in hard drive backplane with NVMe:
Figure 91. Cabling the 24 x 2.5-inch backplane with NVMe hard drives
1 Backplane to expander board signal cable 2 Expander SAS B cable (BP: EXP_SAS B to Expander Board
EXP_SAS B)
3 Backplane 4 Expander SAS A cable(BP: EXP_SAS A to Expander Board
EXP_SAS A)
5 Expander board 6 Expander SAS C cable(BP: EXP_SAS C to Expander Board
EXP_SAS C)
7 PERC cable from sled 2(EB: EXP_PERC2 sled 2 to left linking 8 PERC cable from sled 1(EB: EXP_PERC1 sled 1 to left linking
board) board)
9 Left linking board 10 Linking board connector for sled 1
11 Linking board connector for sled 2 12 PERC cable from sled 4(EB: EXP_PERC4 sled 3 to right
linking board)
13 PERC cable from sled 3(EB: EXP_PERC3 sled 3 to right linking 14 right linking board
board)
15 Linking board connector for sled 3 16 Linking board connector for sled 4
17 Expander SAS E cable(BP: EXP_SAS E to Expander Board 18 Expander SAS F cable(BP: EXP_SAS F to Expander Board
EXP_SAS E) EXP_SAS F)
19 Backplane to expander board power cable 20 Expander SAS D cable(BP: EXP_SAS D to Expander Board
EXP_SAS D)
1 Backplane 2 SATA cable for sled 1(BP: SATA cable sled 1 to left linking
board)
3 Signal cable sled 1(BP: BP_SIG1 to left linking board) 4 Linking board connector for sled 1
5 Left linking board 6 Linking board connector for sled 2
7 SATA cable for sled 2(BP: SATA cable sled 2 to left linking 8 Signal cable sled 2(BP: BP_SIG2 to left linking board)
board)
9 SATA cable for sled 3(BP: SATA cable sled 3 to right linking 10 Signal cable sled 3(BP: BP_SIG3 to left linking board)
board)
11 Right linking board 12 Linking board connector for sled 3
13 Linking board connector for sled 4 14 SATA cable for sled 4(BP: SATA cable sled 4 to right linking
board)
15 Signal cable sled 4(BP: BP_SIG4 to left linking board)
Figure 94. Sled to drive mapping for the enclosure with 24 x 2.5-inch drives
Figure 95. Sled to drive mapping for the enclosure with 12 x 3.5-inch drives
NOTE: The warranty of the drives are linked to the Service Tag of the corresponding sled.
Expander zoning
A SAS expander board allows higher, single-volume hard drive configurations. An integrated expander device expands each sleds hard drive
footprint.
The PowerEdge 6400 enclosure allows four sleds to access a single expander controller at the same time. there are two zoning options
available, they are:
NOTE:
There are two sides to the Power Interposer Board (PIB). The top side has two slots to connect two power supplies. The bottom slot of
the PIB distributes power to the Chassis Manager (CM), hard drive backplane, and the midplane board. The board dimension for the PIB is
86 mm x 81 mm.
Midplane board
The midplane board is used to bridge power from the system chassis to the server sleds. One midplane board is able to support to sleds.
There are two midplane boards in the PowerEdge C6400 to support four sleds. The midplane board dimension is 76.48 mm x 59.5 mm.
The image below shows the midplane board and the components description:
The image below shows the CM board with descriptions of the connectors:
Power supplies
Energy Smart power supplies have intelligent features, such as the ability to dynamically optimize efficiency while maintaining availability and
redundancy. Also featured are enhanced power consumption reduction technologies, such as high-efficiency power conversion and
advanced thermal-management techniques, and embedded power-management features, including high-accuracy power monitoring.
The following power supply unit options are available for the Dell PowerEdge C6420:
• 1600 W AC
• 2000 W AC
• 2400 W AC Power
The image below shows the position of the PowerEdge C6420 power supplies—highlighted in red:
NOTE: Power supplies are certified to be compliant with the 80 Plus Program.
When the maximum potential power needs of installed chassis components exceeds the capacity of a single Power Supply, the Chassis
Management Controller (CMC) will deny power on to further chassis components. The Power Budget Checks for Fault Tolerant
Redundancy ensure that the Shared Infrastructure Chassis will remain operational in the event of maximum potential workload conditions at
the time of an AC Grid or PSU Supply failure. Using the maximum potential is a conservative target that ensures continued operation across
the wide range of potential customer workloads for a given configuration.
Policy philosophy
Similar to Grid Redundancy, Fault Tolerant Redundancy is a conservative redundancy policy that ensures that the Shared Infrastructure
Chassis and all installed components remain operational with no risk of shutdown in the event of an AC Grid or Power Supply failure even
when all installed components are simultaneously running at their worst case power consumption. New for Fault Tolerant Redundancy is a
limit on peak performance that occurs when redundancy is lost. Fault Tolerant Redundancy can maintain the same conservative standards
of redundancy as traditional Grid Redundancy by limiting peak power after redundancy is lost to levels which fit within the surviving Power
Supply.
Policy control
As with all Redundancy Policies, while the two Power Supplies remain healthy, load is shared evenly between them and the capacity of both
Power Supplies is made available for use. In the event of an AC Grid or Power Supply failure, Power Controls will rapidly engage to restrict
the power consumption of the chassis and ensure that consumption is restricted to what a single Power Supply can support. Besides the
controls used with all Redundancy Policies, Fault Tolerant Redundancy also implements more performance limiting functionality which
restricts the peak power after redundancy loss.
For a fully loaded chassis running at maximum potential power this can result in some observed performance reduction as the chassis
Power Control limits are enforced. In practice, customer workloads are often not at the maximum potential power and so practical
performance reduction during an AC Grid or Power Supply failure is often minor or even unnoticeable.
Logging behavior
As with all Redundancy Policies, when a Power Supply Unit fails, a log message is generated. For the Fault Tolerant Redundancy policy, a
log message will also be recorded to note a "Loss of Redundancy". This message indicates that the system is continuing to operate in a
Non-Redundant state, and action is necessary to either restore power to a failed AC Grid or replace a failed Power Supply Unit. Details in
log messages make it possible to distinguish between these two cases. Finally, in case power-on of a chassis component is denied due to a
Power Budget Check, the denial is logged both in CMC logs and iDRAC logs (in the case of compute sleds).
Topics:
Xa Xb Y Za Zb Zc
482.6 mm (19 inches) 448 mm (17.63 86.8 mm (3.41 26.8 mm (1.05 763.2 mm (30.28 797.3 mm (31.38
inches) inches) inches) inches) inches)
Chassis weight
Table 15. Chassis weight of the Dell EMC PowerEdge C6400 enclosure with PowerEdge C6420 sleds
System Maximum weight (with all sleds and drives)
12 x 3.5-inch hard drive systems 43.62 Kg (96.16 lb)
PSU wattage Class Heat dissipation Frequency Voltage Maximum input current
(maximum)
100–240 V AC,
2400 W AC Platinum 9000 BTU/hr 50/60 Hz 14 A–16 A
autoranging
100–240 V AC,
2000 W AC Platinum 7500 BTU/hr 50/60 Hz 11.5 A
autoranging
100–240 V AC,
1600 W AC Platinum 6000 BTU/hr 50/60 Hz 10 A
autoranging
NOTE: This system is also designed to connect to the IT power systems with a phase to phase voltage not exceeding 240 V.
NOTE: If a system with 2400 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 1400 W.
NOTE: If a system with 2000 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 1000 W.
NOTE: If system with 1600 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 800 W.
1 Fan cage 1 connector for fans 1 and 2 2 Left midplane signal cable
3 Chassis management board signal cable to backplane 4 Chassis management board power connector from PIB
Table 17. Supported drive options for the Dell EMC PowerEdge C6400 enclosure
Maximum number of drives in the enclosure Maximum number of drives assigned per sled
12 x 3.5-inch drive systems Three SAS or SATA hard drives and SSDs per sled
24 x 2.5-inch drive systems Six SAS or SATA hard drives and SSDs per sled
24 x 2.5-inch drive systems with NVMe The NVMe backplane supports either of these configurations:
• Two NVMe drives and four SAS or SATA hard drives and SSDs
per sled
• Six SAS or SATA hard drives and SSDs per sled
M.2 SATA drive (optional) The supported capacity of the M.2 SATA card is up to 240 GB
NOTE: The M.2 SATA card can be installed on the x16 riser
slot (slot 5).
Micro-SD card (optional) for boot (up to 64 GB) One on each PCIe riser of each sled
Options Single M.2 SATA drive without RAID Dual M.2 SATA drives with hardware RAID
Hardware RAID No Yes
Environmental specifications
The sections below contains information about the environmental specifications of the system.
NOTE: For additional information about environmental certifications, please refer to the Product Environmental Datasheet
located with the Manuals & Documents on Dell.com/poweredgemanuals
1 Not available: Indicates that the configuration is not offered by Dell EMC.
2 Not supported: Indicates that the configuration is not thermally supported.
NOTE: All components including the DIMMs, communication cards, M.2 SATA, and PERC cards can be supported with sufficient
thermal margin if the ambient temperature is equal to or below to the maximum continuous operating temperature listed in these
tables except for the Mellanox DP LP card and Intel Rush Creek card.
Table 20. Maximum continuous operating temperature for nonfabric dual processor configuration
Max No-BP
3.5-inch chassis 2.5-inch chassis
memor Chassis
TDP Processo Heat sink
Watts r model model y/ 4x 24x 20x 12x 8x 4x
proces 12x 8x 16x
Drives Drive Drive Driv Drive Drive Drive N/A
sor Drives Drives
s s es s s s
CPU1: CPU1:
FMM2M | 6|
8280 20 21 21 21 21 30
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
FMM2M | 6|
8280L 20 21 21 21 21 30
CPU2: CPU2:
V2DRD 8
Not Not Not
CPU1: CPU1: Not
Suppo Supp Supp
FMM2M | 6| Suppor
205 W 8280M rted orted orte 20 21 21 21 21 30
CPU2: CPU2: ted
(10°C (11°C d(19°
V2DRD 8 (2°C)
) ) C)
CPU1: CPU1:
FMM2M | 6|
8270 20 21 21 21 21 30
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
FMM2M | 6|
8268 20 21 21 21 21 30
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
8276 30 30 30 30 30 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
8276L 30 30 30 30 30 35 35
CPU2: CPU2: Not Not Not
V2DRD 8 Suppor Suppo Supp
165 W
CPU1: CPU1: ted(11° rted(1 orted(
JYKMM | 8| C) 8°C) 19°C)
8276M 30 30 30 30 30 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
8260 30 30 30 30 30 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
8260M 30 30 30 30 30 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
8260C 30 30 30 30 30 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
6252 21 23 30 30 30 30 30 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
6248 21 23 30 30 30 30 30 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
6240 21 23 30 30 30 30 30 35 35
CPU2: CPU2: Not
V2DRD 8 Suppor
150 W
CPU1: CPU1: ted(14
JYKMM | 8| °C)
6242 21 23 30 30 30 30 30 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
FMM2M | 6|
6244 21 23 30 30 30 30 30 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
FMM2M | 6|
6240C 21 23 30 30 30 30 30 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
6230 25 30 30 30 30 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
125 W
CPU1: CPU1:
JYKMM | 8|
5220 25 30 30 30 30 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
5218B 25 30 30 30 30 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
8253 25 30 30 30 30 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
6238T 25 30 30 30 30 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
6230N 25 30 30 30 30 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
FMM2M | 6|
115 W 5217 25 30 30 30 30 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
FMM2M | 6|
5218T 30 35 35 35 35 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
FMM2M | 6|
5218N 30 35 35 35 35 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
105 W
CPU1: CPU1:
FMM2M | 6|
5222 30 35 35 35 35 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
FMM2M | 6|
8256 30 35 35 35 35 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
100 W 4216 30 35 35 35 35 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
5215M 35 35 35 35 35 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
5215L 35 35 35 35 35 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
4215 35 35 35 35 35 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
85 W 4214 35 35 35 35 35 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
4214C 35 35 35 35 35 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
4210 35 35 35 35 35 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
4208 35 35 35 35 35 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
3204 35 35 35 35 35 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
CPU1: CPU1:
JYKMM | 8|
70 W 4209T 35 35 35 35 35 35 35 35 35 35
CPU2: CPU2:
V2DRD 8
Max No-BP
3.5-inch chassis 2.5-inch chassis Chassis
Processor Heat sink memor
TDP Watts y/ 12x 8x 4x 24x 16x
model model
Drive Drive Drive 20x Drive 12x
process 8x 4x
Drive N/A
or Drives Drives Drives Drives
s s s s s
CPU1:
8280 CPU1: 6 30 30 30 35 35 35 35 35 35 35
FMM2M
CPU1:
8280L CPU1: 6 30 30 30 35 35 35 35 35 35 35
FMM2M
CPU1:
205W 8280M CPU1: 6 30 30 30 35 35 35 35 35 35 35
FMM2M
CPU1:
8270 CPU1: 6 30 30 30 35 35 35 35 35 35 35
FMM2M
CPU1:
8268 CPU1: 6 30 30 30 35 35 35 35 35 35 35
FMM2M
CPU1:
200 W 6254 CPU1: 6 30 30 30 35 35 35 35 35 35 35
FMM2M
CPU1:
6212U CPU1: 8 30 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
8276 CPU1: 8 30 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
8276L CPU1: 8 30 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
8276M CPU1: 8 30 35 35 35 35 35 35 35 35 35
JYKMM
165 W
CPU1:
8260 CPU1: 8 30 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
8260L CPU1: 8 30 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
8260M CPU1: 8 30 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
8260C CPU1: 8 30 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
6210U CPU1: 8 30 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
6252 CPU1: 8 30 35 35 35 35 35 35 35 35 35
JYKMM
150 W
CPU1:
6248 CPU1: 8 30 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
6240 CPU1: 8 30 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
6244 CPU1: 6 30 35 35 35 35 35 35 35 35 35
FMM2M
CPU1:
6240C CPU1: 6 30 35 35 35 35 35 35 35 35 35
FMM2M
CPU1:
6230 CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
5220 CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
5218 CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
125W 5218B CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
8253 CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
6238T CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
6230N CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
115 W 5217 CPU1: 6 30 35 35 35 35 35 35 35 35 35
FMM2M
CPU1:
5218T CPU1: 6 30 35 35 35 35 35 35 35 35 35
FMM2M
CPU1:
5218N CPU1: 6 30 35 35 35 35 35 35 35 35 35
FMM2M
105 W
CPU1:
5222 CPU1: 6 30 35 35 35 35 35 35 35 35 35
FMM2M
CPU1:
8256 CPU1: 6 30 35 35 35 35 35 35 35 35 35
FMM2M
CPU1:
100 W 4216 CPU1: 8 30 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
5215 CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
85 W 5215M CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
5215L CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
4214 CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
4214C CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
4210 CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
4208 CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
3204 CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
CPU1:
70 W 4209T CPU1: 8 35 35 35 35 35 35 35 35 35 35
JYKMM
Table 22. Configuration Restrictions with Mellanox Navi Dual Port Card with Active (Optical) connectivity
No-BP
3.5-inch chassis 2.5-inch chassis
TDP Watts Chassis
12x HDDs 8x HDDs 4x HDDs 24x HDDs 16x HDDs 8x HDDs 4x HDDs N/A
Not Not Not Not Not Not Not
205 W 23
supported supported supported supported supported supported supported
Not
140 W 23 25 28 29 29 30 33
supported
Not
135 W 24 25 29 30 30 31 33
supported
Not
130 W 24 26 30 31 31 31 34
supported
125 W 20 25 27 30 31 32 32 35
113 W 21 27 28 32 33 34 34 >35
No-BP
3.5-inch chassis 2.5-inch chassis
TDP Watts Chassis
12x HDDs 8x HDDs 4x HDDs 24x HDDs 16x HDDs 8x HDDs 4x HDDs N/A
205 W Not Not Not Not Not 20 20 23
supported supported supported supported supported
115W Not 21 23 29 31 31 32 34
supported
105 W 20 23 24 30 33 33 34 >35
No-BP
3.5-inch chassis 2.5-inch chassis
TDP Watts Chassis
12x HDDs 8x HDDs 4x HDDs 24x HDDs 16x HDDs 8x HDDs 4x HDDs N/A
205 W Not Not Not Not Not Not Not Not
supported supported supported supported supported supported supported supported
NOTE: Outside the standard operating temperature (10°C–35°C), the system can
operate continuously in temperatures as low as 5°C and as high as 40°C.
For temperatures between 35°C and 40°C, derate maximum allowable temperature by 1°C
per 175 m above 950 m (1°F per 319 ft).
≤ 1% of annual operating hours –5°C–45°C at 5% to 90% RH with maximum 29°C dew point.
NOTE: Outside the standard operating temperature (10°C–35°C), the system can
operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating
hours.
For temperatures between 40°C-45°C, derate maximum allowable temperature by 1°C per
125 m above 950 m (1°F per 228 ft).
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported in the System Event
Log.
> 45°C (113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above
950 meters (3,117 ft).
Operating 10% to 80% relative humidity with 29°C (84.2°F) maximum dew
point.
Temperature Specifications
Storage –40°C–65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C–35°C (50°F to 95°F) with no direct sunlight on the
equipment.
Fresh air For information about fresh air, see Expanded Operating
Temperature section.
NOTE: Some configurations require a lower ambient temperature for more information, see the Standard operating temperature
specifications.
NOTE: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment
designed to be used outside a data center, in environments such as an office or factory floor.
NOTE: Air entering the data center must have MERV11 or MERV13 filtration.
NOTE: This condition applies to data center and non-data center environments.
Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE: This condition applies to data center and non-data center environments.
Silver coupon corrosion rate <200 Å/month per Class G1 as defined by ANSI/ISA71.04-2013
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Topics:
• System cover, cooling shroud, EMI filler panel, memory module blank, or back filler bracket is not removed.
• Ambient temperature is not higher than the system specific ambient temperature.
• External airflow is not obstructed.
• A cooling fan is not removed or has not failed.
• The expansion card installation guidelines have been followed.
1 Select iDRAC Settings > Thermal, and set a higher fan speed from the fan speed offset or minimum fan speed.
For more information, see Integrated Dell Remote Access User’s Guide at Dell.com/poweredgemanuals
System messages
For information about the event and error messages generated by the system firmware and agents that monitor system components, see
the Error Code Lookup page at qrl.dell.com
NOTE: To locate the product name and model, see the front of your system.
c On the Product Support page, click Manuals & documents.
• Using search engines:
– Type the name and version of the document in the search box.
Configuring your system For information about the iDRAC features, Dell.com/poweredgemanuals
configuring and logging in to iDRAC, and managing
your system remotely, see the Integrated Dell
Remote Access Controller User's Guide.
For information about understanding Remote
Access Controller Admin (RACADM)
subcommands and supported RACADM interfaces,
see the RACADM CLI Guide for iDRAC.
For information about setting up, using, and Dell.com/openmanagemanuals > OpenManage
troubleshooting OpenManage, see the Dell Server Administrator
OpenManage Server Administrator User’s Guide.
Working with the Dell For information about understanding the features Dell.com/storagecontrollermanuals
PowerEdge RAID controllers of the Dell PowerEdge RAID controllers (PERC),
Software RAID controllers, or BOSS card and
deploying the cards, see the Storage controller
documentation.
Understanding event and error For information about the event and error Dell.com/qrl
messages messages generated by the system firmware and
agents that monitor system components, see the
Error Code Lookup.
Document History
Date Owner Page
Requested By Reviewed By Approved By
Change
Requested By: Fusion Ticket 39381396 Reviewed By: Approved By: George Cherian