16/7/24, 9:52 a.m. SIS 2.

Instructions for Communicating With and Flashing the 10R-4085 Engine Electronic Control Gp
and the 10R-1824 Engine Electronic Control Gp {1901, 1920} (REHS7298-07)

SMCS - 1901, 1920 i09934762


Caterpillar Products
PIP
All
-
202 1011
8
Revision History:
Table 1
12: 4 / 0 791
5 7/ 1
RE :01- 6
2
Revision Summary of Changes
07 Added barcode.
06
05
Added barcode.
Revised the entire procedure
H
© 2 S729 03:00
Introduction
024 8
Cat
erp
illa
rI nc.

Illustration 1 g07652772
This Special Instruction is used to set up communications with and flash both the 10R-4085 Engine
Electronic Control Gp and 10R-1824 Engine Electronic Control Gp.

Safety Section

https://sis2.cat.com/#/print-preview/service/5e2e16a3-f16d-4294-8356-80e5e4b7c1cf 1/6
16/7/24, 9:52 a.m. SIS 2.0

Do not operate or work on this product unless you have read


and understood the instructions and warnings in the relevant
Operation and Maintenance Manuals and relevant service
literature. Failure to follow the instructions or heed the warnings
could result in injury or death. Proper care is your responsibility.

Required Tools
Table 2

Required Tools
Item Qty Part Number Part Name
T1 1 399-7427 Power Cable As
T2 1 538-5051 Communication Adapter Gp
T2 T2a 1 478-0235 Communication Adapter
T2 T2b 1 457-6114 (DATA LINK) Cable As
T2 T2c 1 370-4617 Cable As

Communications Setup and Flashing Procedure

Illustration 2 g06606260
View of the Electronic Control Module (ECM)
(1) J1 connector

1. Connect the Power Cable As (T1) to the J1 connector (1) of the Electronic Control Module
(ECM).

2. Connect the (DATA LINK) Cable As (T2b) to the Communication Adapter (T2a).

3. Connect the Communication Adapter (T2a) to the computer using the Cable As (T2c).

https://sis2.cat.com/#/print-preview/service/5e2e16a3-f16d-4294-8356-80e5e4b7c1cf 2/6
16/7/24, 9:52 a.m. SIS 2.0

4. Connect the black harness clip of the Power Cable As (T1) to "–BAT".

5. Connect the red harness clip of the Power Cable As (T1) to "+BAT".

Illustration 3 g06606066
(2) "OK"

6. Start the communication with Cat ® Electronic Technician (ET). When the screen above
appears click "OK" (2).

Illustration 4 g06606085
(3) "Cancel"

https://sis2.cat.com/#/print-preview/service/5e2e16a3-f16d-4294-8356-80e5e4b7c1cf 3/6
16/7/24, 9:52 a.m. SIS 2.0

Illustration 5 g06606094
(3) "Cancel"
7. Wait until one of the two screens above appears. In either of the two screens select "Cancel"
(3).

Illustration 6 g06606110
(4) "Utilities"
(5) "Winflash"

https://sis2.cat.com/#/print-preview/service/5e2e16a3-f16d-4294-8356-80e5e4b7c1cf 4/6
16/7/24, 9:52 a.m. SIS 2.0

8. Open the "Utilities" menu (4) and then select "Winflash" (5).

Illustration 7 g06607991
Winflash configuration window
(6) American Trucking Association (ATA)
(7) "Software Part Number"
(8) "Load Product Flash File"
Note: ECM will not flash unless American Trucking Association (ATA) is connected and
Winflash is configured for ATA communication (6).

9. Wait until the ECM has been linked.

10. The current "Software Part Number" (7) will show 0000000-00. (This part number is normal
and does not mean that the ECM memory has not been washed at the factory).

11. Select "Load Product Flash File" (8) to select the name of the flash file that will be
programmed into the ECM.

https://sis2.cat.com/#/print-preview/service/5e2e16a3-f16d-4294-8356-80e5e4b7c1cf 5/6
16/7/24, 9:52 a.m. SIS 2.0

Illustration 8 g06606213
(9) "Open"
12. A new window will appear. Select the correct flash file and press "Open" (9).

13. Verify that the "File Values" match the application. If the "File Values" do not match the
application, obtain the correct flash file.

14. When the correct flash file is selected, select "Begin Flash".

15. Cat ET will indicate when flash programming has been successfully completed.

PIP-10118791
2024/07/16
12:51:50-03:00
i04751217
© 2024 Caterpillar Inc.

https://sis2.cat.com/#/print-preview/service/5e2e16a3-f16d-4294-8356-80e5e4b7c1cf 6/6