2020-03-16 La Palma HVAC - Str. Drawings
2020-03-16 La Palma HVAC - Str. Drawings
2020-03-16 La Palma HVAC - Str. Drawings
IDS
CONC. CONCRETE CONSTRUCTION SHALL BE USED SUBJECT TO PRIOR REVIEW BY THE ENGINEER.
PCF POUNDS PER CU.FT. SHOWN IN THE APPLICABLE DETAILS UNLESS OTHERWISE NOTED.
CONN. CONNECTION
PL. PLATE 12. CONDITIONS NOTED AS "EXISTING" OR (E) ARE TO REMAIN U.N.O. PROTECT AS REQUIRED. "EXISTING"
CONST. CONSTRUCTION
PLYWD. PLYWOOD 9. PLYWOOD NAILING SHALL HAVE A MINIMUM EDGE DISTANCE OF 3/8". NAIL HEADS SHALL BE FLUSH WITH TOP SURFACE CONSTRUCTION REMOVED BY THE CONTRACTOR FOR ANY REASON SHALL BE REPLACED TO MATCH
CONT. CONTINUOUS
P.P. PARTIAL-PENETRATION OF PLYWOOD; SINKING NAIL HEADS IS PROHIBITED. EXISTING AT NO ADDITIONAL COST TO THE OWNER. ALL MATERIALS, FEATURES OR CONDITIONS NOT
C.P. COMPLETE-PENETRATION
P.S.F. POUNDS PER SQUARE FOOT SPECIFICALLY IDENTIFIED AS "EXISTING" OR (E) ARE CONSIDERED NEW WORK AND ARE PART OF THE IDS GROUP
CTSK. COUNTERSINK PROJECT SCOPE OF WORK.
P.S.I. POUNDS PER SQUARE INCH 10. PROVIDE PLYWOOD EDGE NAILING AROUND THE PLYWOOD OPENINGS AND ALONG THE FULL HEIGHT OF ALL WOOD
CTR. CENTER(ED) 1 PETERS CANYON ROAD, SUITE 130
PT PRETENSIONED POSTS AND COLUMNS. 13. ALL EXISTING CONDITIONS, WHETHER OR NOT SPECIFICALLY NOTED ON THE DRAWINGS, SHALL BE VERIFIED
C.Y. CUBIC YARD IRVINE, CA. 92606
P.T. PRESSURE TREATED PRIOR TO THE COMMENCEMENT OF ANY WORK. DO NOT PROCEED WITH ANY ITEM OR WORK THAT IS
TEL: 949-387-8500, FAX: 949-387-0800
11. LAG SCREWS SHALL BE SCREWED, NOT DRIVEN, INTO WOOD MEMBERS WITH PRE-DRILLED HOLES. PRE-DRILLED HOLE DIAMETER REASONABLY QUESTIONABLE WITHOUT ADVISING THE OWNER. OBTAIN DIRECTION FROM THE OWNER AS TO
IN SOFT STRUCTURAL WOODS SHALL EQUAL SCREW SHANK DIAMETER AT THE SCREW SHANK, AND SHALL BE UNDERSIZED BY 25% HOW TO PROCEED. SUBMIT ALL QUESTIONS ON "RFI" FORM.
d d PENNY NAIL
QTY. QUANTITY OF SCREW DIAMETER AT THE SCREW THREADS. FOR EXAMPLE, FOR A 3/8” SCREW, THE PRE-DRILLED HOLE SHALL BE 3/8” OVER
DBA DEFORMED BAR ANCHOR 14. ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE
DBL. DOUBLE THE LENGTH OF THE SCREW SHANK, AND SHALL BE 9/32” OVER THE LENGTH OF THE SCREW THREADS. FOR HARD WOODS USED IN ENGINEER FOR RESOLUTION PRIOR TO COMMENCING ANY WORK.
A STRUCTURAL APPLICATION, PRE-DRILLED HOLE DIAMETER AT THE SHANK SHALL MATCH THE SCREW DIAMETER, AND THE HOLE STAMP
DEPT. DEPARTMENT
RAD. (R) RADIUS DIAMETER OVER THE LENGTH OF THE SCREW THREADS SHALL BE UNDERSIZED BY 12.5% OF THE SCREW DIAMETER. 15. SHOP DRAWINGS REQUIRED BY THE PROJECT SPECIFICATIONS SHALL BE SUBMITTED TO THE ENGINEER FOR
D.F. DOUGLAS FIR REVIEW PRIOR TO FABRICATION. DRAWINGS ARE REVIEWED BY THE ENGINEER FOR GENERAL
RBS REDUCED BEAM SECTION
DIA. (Ø) DIAMETER CONFORMANCE TO THE DESIGN. REGARDLESS OF THE ENGINEER'S REVIEW, THE CONTRACTOR IS FULLY
REF. REFERENCE 11. SILL PLATES IN DIRECT CONTACT WITH CONCRETE, MASONRY, OR EARTH, SHALL BE PRESSURE TREATED WOOD OR
DIAG. DIAGONAL AND SOLELY RESPONSIBLE FOR COMPLETE AND SATISFACTORY SUBMITTAL AND CONFORMANCE TO THE
REINF. REINFORCEMENT (ING) APPROVED EQUAL. PRESSURE TREATED WOOD SHALL BE TREATED WITH ALKALINE COPPER QUAT (ACQ-C AND ACQ-D),
DIAPH. DIAPHRAGM CONTRACT DOCUMENTS. SHOP DRAWINGS WILL BE REJECTED FOR INCOMPLETENESS, LACK OF
REQ'D. (REQD.) REQUIRED CARBONATE AZOLE (CBA-A), OR COPPER AZOLE (CA-B).
DIM. DIMENSION CALCULATIONS (IF REQUIRED) OR CHANGES WITHOUT PRE-APPROVAL. ALL STRUCTURAL CALCULATIONS
RF. ROOF AND DRAWINGS AS PART OF THE SHOP DRAWINGS SUBMITTAL SHALL BE SIGNED AND STAMPED BY A
DN. DOWN
R.O. ROUGH OPENING 12. PROVIDE DOUBLE OR 4x FLOOR JOIST UNDER PARALLEL, NON-BEARING PARTITION WALL UNLESS OTHERWISE NOTED. CALIFORNIA REGISTERED STRUCTURAL ENGINEER. FOR RESUBMITTALS, ALL CHANGES FROM THE PRIOR
DO DITTO (REPEAT)
DWG. (DWGS.) DRAWING(S) SUBMITTAL SHALL BE TIGHTLY ENCLOSED BY A "CLOUD" SO AS TO INDICATE ONLY THOSE AREAS CHANGED.
13. PROVIDE LAMINATED DOUBLE STUDS UNDER EACH SUPPORT OF BEAMS UNLESS OTHERWISE NOTED. WHEN THE CLOUDED DRAWINGS ARE RESUBMITTED, ONLY THE CLOUDED AREAS WILL BE REVIEWED.
DWL. DOWEL
S.A.D. SEE ARCHITECTURAL DRAWINGS STAMP
SC SLIP-CRITICAL 14. SOLID BLOCKING SHALL BE PLACED BETWEEN JOISTS AT POINTS OF SUPPORT AND POINTS WHERE SHEATHING IS 16. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, AND SHALL BE SOLELY RESPONSIBLE FOR ALL
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. THE SUPPORTING
S.C.D. SEE CIVIL DRAWINGS DISCONTINUOUS.
EA. EACH SERVICES BY THE ENGINEER, WHETHER PERFORMED PRIOR TO, DURING, OR AFTER CONSTRUCTION, ARE
SCH. SCHEDULE PERFORMED SOLELY FOR THE PURPOSE OF ASSISTING IN QUALITY CONTROL AND IN ACHIEVING
E.F. EACH FACE
SEP. SEPARATION 15. APPLY ADHESIVE TO CONTACT SURFACES BETWEEN HORIZONTAL PLYWOOD SHEATHING AND SUPPORTING WOOD CONFORMANCE WITH CONTRACT DRAWINGS AND PROJECT SPECIFICATIONS; BUT THEY DO NOT GUARANTEE
E.J. EXPANSION JOINT
SHT. SHEET MEMBER. THE CONTRACTOR'S PERFORMANCE AND SHALL NOT BE CONSIDERED AS SUPERVISION OF CONSTRUCTION.
EL. ELEVATION
SIM. SIMILAR
ELEC. ELECTRICAL 17. THE CONTRACTOR IS FULLY AND SOLELY RESPONSIBLE FOR ALL SHORING REQUIRED IN ORDER TO SAFELY
SKW. SKEW(ED) 16. WOOD MEMBER WITH WANE SHALL NOT BE LOCATED AT PLYWOOD JOINT.
ELEV. ELEVATOR ACHIEVE THE FINAL CONSTRUCTION SHOWN ON THE DRAWINGS. THIS INCLUDES, BUT IS NOT LIMITED TO,
S.O.G. SLAB-ON-GRADE
EMB. EMBED(MENT) ANY TYPES OF SHORING REQUIRED FOR SOILS EXCAVATION AND BACKFILL WORK; SUPPORT OF
SPEC. SPECIFICATION 17. NO STRUCTURAL MEMBER SHALL BE CUT WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER. STRUCTURAL ELEMENTS UNTIL THEY HAVE ACHIEVED THE NECESSARY STRENGTH TO PERFORM IN THE
E.N. EDGE NAIL
SQ. SQUARE FINAL POSITION AND MANNER SHOWN ON THE DRAWINGS; AND SUPPORT OF STRUCTURAL ELEMENTS THAT ISSUE
ENG. ENGINEER
ST SNUG-TIGHTENED 18. HARDWARE CONNECTING WOOD MEMBERS SHALL BE RECESSED WHEN REQUIRED BY ARCHITECTURAL FINISH. VERIFY ARE MODIFIED AND THEREBY REDUCED IN STRENGTH IN ANY WAY DURING CONSTRUCTION AS REQUIRED TO
EQ. EQUAL REV. DESCRIPTION DATE
STD. STANDARD WITH ARCHITECTURAL DRAWINGS. ACHIEVE THE FINAL CONSTRUCTION AS SHOWN ON THE DRAWINGS. ALL SHORING CALCULATIONS AND
EQPT. EQUIPMENT
STAGG. STAGGER(ED) DRAWINGS SHALL BE STAMPED BY A CALIFORNIA REGISTERED ENGINEER AND SUBMITTED FOR REVIEW
EQUIV. EQUIVALENT CITY SUBMITTAL 3/16/2020
STIFF. STIFFENER 19. 0.229"x2"x2" STEEL PLATE WASHERS (OR SIMPSON BP) SHALL BE USED FOR ALL SILL PLATE ANCHOR BOLTS AND PRIOR TO PERFORMING THE WORK.
EXP. EXPANSION
STIR. STIRRUP HOLDOWN CONNECTOR BOLTS UNLESS OTHERWISE NOTED. SIMPSON BP SHALL BE PROTECTED WITH ZMAX (G185) 18. THE CONTRACTOR SHALL COORDINATE ALL UTILITY LOCATIONS WITH OTHER DRAWINGS AND SHALL
EXIST. (E) EXISTING
STL. STEEL COATING. CONDUCT A DETAILED SURVEY OF EXISTING UTILITIES TO IDENTIFY INTERFERENCES WITH THE NEW
EXT. EXTERIOR
STRUC(T). STRUCTURAL CONSTRUCTION. PROMPTLY NOTIFY THE ENGINEER OF ANY INTERFERENCES PRIOR TO PERFORMING THE
SUSP. SUSPENDED 20. ALL BOLTS SHALL BE RE-TIGHTENED JUST PRIOR TO BEING COVERED. WORK.
SYMM. SYMMETRICAL
FDN. FOUNDATION 19. IN THE EVENT THAT THERE ARE ANY UTILITIES AFFECTED, ANY MODIFICATIONS SHALL BE THE
21. BOLT HOLES AT WOOD MEMBERS SHALL NOT BE MORE THAN 1/16" LARGER THAN THE BOLT DIAMETER.
FIN. FINISH(ED) RESPONSIBILITY OF THE CONTRACTOR AND NOT THAT OF THE OWNER. ALL OUTLETS EITHER ELECTRICAL OR
FLR. FLOOR MECHANICAL, OR ANY ASSOCIATED REWORK OR MODIFICATIONS WILL BE A PART OF THE BID AND NOT TO BE
T&B TOP AND BOTTOM 22. ALL HARDWARE AND FASTENERS IN CONTACT WITH TREATED WOOD SILL PLATES SHALL BE ZINC- COATED. ALL NAILS CONSTRUED AS THE WORK OF THE OWNER. SUFFICIENT DUE DILIGENCE ON THE PART OF THE CONTRACTOR
F.N. FIELD NAIL; FACE NAIL
T&G TONGUE AND GROOVE INTO TREATED SILL PLATES SHALL BE HOT-DIPPED ZINC-COATED GALVANIZED OR SIMPSON ZMAX (G185) COATED NAILS. WILL ELIMINATE ANY POTENTIAL ISSUES AND ACCEPTANCE OF THE AGREEMENT SHALL BIND CONTRACTOR
F.O.C. FACE OF CONCRETE
TEMP. TEMPORARY TO SAID ACCEPTANCE.
F.O.M. FACE OF MASONRY
THK. THICK(NESS) 23. SOLID BLOCKING OR EQUIVALENT CROSS-BRIDGING SHALL BE INSTALLED BETWEEN ALL ROOF AND FLOOR JOISTS AT
F.O.S. FACE OF STUD 20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA DURING CONSTRUCTION
T.N. TOE NAIL THE SPACING PER CODE.
F.O.W. FACE OF WALL PERIOD. THE CONTRACTOR SHALL PROTECT ADJACENT PROPERTY AND UTILITIES IN ACCORDANCE WITH ALL
T.O. TOP OF NATIONAL, STATE, AND LOCAL SAFETY ORDINANCES.
F.P. FULL (COMPLETE) PENETRATION
T.O.C. TOP OF CONCRETE 24. FIRE BLOCKING SHALL BE INSTALLED BETWEEN ALL WALL STUDS IF REQUIRED BY CODE.
FRP FIBER REINFORCED POLYMER 21. PROVIDE BARRICADING AND MAINTAIN ANY REQUIRED LIGHTS, WARNING, AND DIRECTIONAL SIGNS, AND
T.O.S. TOP OF STEEL;
F.S. FAR SIDE OTHER PROTECTION NEAR AND ABOUT THE AREA OF THE WORK AS MAY BE REQUIRED BY THE OWNER, OR
TOP OF SHEATHING
FT. (') FOOT (FEET) BY ANY OTHER GOVERNING AUTHORITY. PROVIDE NECESSARY MEANS TO PROTECT ANY SURROUNDING
T.O.W. TOP OF WALL
FTG. FOOTING ADJACENT SITE STRUCTURES, PROPERTIES, SERVICING UTILITIES, PEDESTRIAN AND VEHICLE WAYS, AND KEY PLAN
TRANS. TRANSVERSE
F.V. FIELD VERIFY MAINTAIN ALL SAFETY MEASURES UNTIL WORK IS COMPLETED.
T.S.G. TAPERED STEEL GIRDER
TYP. TYPICAL 22. SECURE THE CONSTRUCTION SITE. ANY PARTS OF WORK AREA WHICH ARE TO BE BARRICADED OR SEALED
GA. GAUGE TO NON-CONSTRUCTION INDIVIDUALS MUST BE COORDINATED WITH AND APPROVED BY THE OWNER BEFORE
GALV. GALVANIZE(D) PROCEEDING WITH THE WORK.
GLB. GLU-LAM/GLULAM
U.O.N. (U.N.O.) UNLESS OTHERWISE NOTED 23. PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE AND ADJACENT STRUCTURE(S),
GLUED LAMINATED BEAM
UTIL. UTILITY FINISHES AND UTILITIES DURING CONSTRUCTION.
GRD. GRADE
GYP. GYPSUM 24. PROVIDE AND ENGINEER ALL TEMPORARY STRUCTURAL AND SAFETY ELEMENTS REQUIRED TO ACCOMPLISH
THE WORK.
25. THE CONTRACTOR SHALL EXERT EVERY EFFORT TO PREVENT DUST AND CONSTRUCTION DEBRIS FROM
VERT. (V) VERTICAL CONTAMINATING THE WORK AREA. THESE EFFORTS SHALL INCLUDE BUT NOT BE LIMITED TO PROVIDING A
HD. HOLDOWN; HAND V.I.F. VERIFY IN FIELD DAILY CLEANUP OF THE CONSTRUCTION AREA. THE CONTRACTOR SHALL REFER TO THE PROJECT
HDR. HEADER SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
HGR. HANGER W/ WITH
HORIZ. (H) HORIZONTAL (W) WIDE; WIDTH 26. CUTTING, BORING, SAW-CUTTING OR DRILLING THROUGH NEW STRUCTURAL MEMBERS OTHER THAN THOSE
DETAILED ON STRUCTURAL DRAWINGS SHALL NOT BE DONE WITHOUT THE ENGINEER'S APPROVAL.
H.S. HEADED STUD WD. WOOD
H.S.B. HIGH STRENGTH BOLT W.P. WORK POINT 27. PERFORM ALL PATCHING AND RESTORATION AS REQUIRED BY THE WORK. THE WORK SHALL MATCH PROJECT NO. 17X115.00
HT. HEIGHT WT. WEIGHT ADJACENT SURFACES UNLESS SPECIFICALLY NOTED OTHERWISE TO THE SATISFACTION OF THE OWNER.
W.W.F. WELDED WIRE FABRIC PRINT DATE 3/16/2020
SHEET TITLE
JST. JOIST
JT. JOINT
STRUCTURAL
GENERAL NOTES
SHEET NUMBER
S0.1
CLIENT
CITY HALL
HVAC REPLACEMENT
7'-418"
PROJECT
L.
L.
O
O
/8 /8
C
3 3
8x 8x
BE
BE
3x )3
x
TU
TU
)
(E (E
L
ST
ST
A A
7"x13" COMB. B HDR
5'-9"
ENGINEER/ARCHITECT
8'-0"
20'-6"
12'-9" 7'-9" 5'-9" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0"
IDS
IDS GROUP
1 PETERS CANYON ROAD, SUITE 130
IRVINE, CA. 92606
8'-0"
6
S2.0 4X 4X
X
) )
)4
)4
)4
)4
)4
(E (E
(E
(E
(E
(E
(E
X4
)4
A.4
(E
STAMP
4
4X
)
(E
8'-0"
X4
TYP.
)4
(E
4
4x
4x
CU
4X
9 02
)
(E
TO 6 / S2.0
(E
29'-6"
4
4
4X
X
)
)4
(E
(E
GV
(E) 4x14 @ 8'-0" O.C. 1
ISSUE
4x BLK'G
REV. DESCRIPTION DATE
ROOF SCUTTLE DOAS
1 CITY SUBMITTAL 3/16/2020
4x
4x
8'-0"
Wmax=1440#
4x BLK'G
X4
)4
4
(E
X
A.9 (E) 4x14 @ 8'-0" O.C. E )4
(
(E
)4 4x BLK'G
X4
X4 X4
X6
X4
X4
X4
4 4
4x
4x
E) E)
)4
)4
)4
)4
EF ( (
(E
(E
(E
(E
8'-0"
1
4x BLK'G B
FOR OPENING
(E
CU
)4
X4
01
)4
22"x22" REFER
(E
Wmax=890#
TO 6 / S2.0
B.4
4"x14" @ 8'-0" O.C.
25'-6"
B.6
TYP.
DRAWN BY NN
C C CHECKED BY AB
2'-3"
SHEET TITLE
ROOF FRAMING
2'-3" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0"
PLAN
1.0 2.0 3.0 4.0
SHEET NUMBER
MIN.
4x6 CONT. W/ (2) A35 EA. END
6"
A35 EA. END
MIN.
7822 WALKER STREET
6"
4x6 CONT. W/ (2)
MIN.
6"
A35 EA. END LA PALMA, CA 90623
PROJECT NAME
4x BLK'G (E) 2x JOISTS
4x BLK'G. W/ (2) A35 BEYOND
4x BLK'G 4x6 CONT. W/ (2) 4x BLK'G.
(E) 2x JOIST 3 "Ø THRU BOLT (2)
4 EA. END CITY HALL
PER SIDE, 6" MAX.
A35 EA. END
3 "Ø THRU BOLT (2) PER SIDE,
FROM END (COUNTERSUNK) HVAC REPLACEMENT
4 3 "Ø THRU BOLT (2) PER SIDE,
12" MAX. FROM END (E) 4x14, TYP. 4
(COUNTERSUNK) 12" MAX. FROM END 2
(E) 4x14 BEYOND (N) DBL 2x6 JOIST W/
PROJECT
4x BLK'G
(COUNTERSUNK) -
HUS26-2 W/ 4-16d AT EA.
END, TYP.
NOTE: FOR FLASHING & INSULATION SEE ARCH. DRAWINGS
NOTE: FOR FLASHING & INSULATION SEE ARCH. DRAWINGS NOTE: FOR FLASHING & INSULATION SEE ARCH. DRAWINGS
SECTION AT MECH. UNIT DOAS 1" = 1'-0" 16 SECTION AT MECH. UNIT DOAS 1" = 1'-0" 12 SECTION AT MECH. UNIT DOAS 1" = 1'-0" 4
7822 Walker Street
La Palma, CA 90623
SEE PLAN
2'-0" MAX. TYP.
CITY PROJECT NO. 17-BLDG-02
ENGINEER/ARCHITECT
EQUIPMENT PER MECH.
CU-01 OR CU-02
IDS
4x BLK'G 4x BLK'G 4x BLK'G 4x BLK'G
19
(N) 4x6
(N) 4x6
W/ MIN. 4" PENETRATION INTO
(E) 2x
(E) 2x
4x6 CONT. W/ (2) 1 PETERS CANYON ROAD, SUITE 130
MIN.
4x6 FRAMEWORK
6"
A35 EA. END IRVINE, CA. 92606
TEL: 949-387-8500, FAX: 949-387-0800
(E) PLYWD. SHTG.
1A
-
STAMP
4x BLK'G 4x BLK'G 4x BLK'G 4x BLK'G
3 "Ø THRU BOLT (2) PER SIDE,
4
6" MAX. FROM END
MECH. EQUIPEMENT, SEE MECH. (COUNTERSUNK) (E) 4x14 BEYOND 4x BLK'G (N) DBL 2x6 JOIST W/
RAISED WOOD PLATFORM PER 3/- DWG FOR LOCATION AND SIZE HUS26-2 W/ 4-16d AT EA.
NOTE: 12 END, TYP.
VERIFY DIMENSIONS & LOCATION W/ MECHANICAL AND ARCH. DWGS. -
NOTE: FOR FLASHING & INSULATION SEE ARCH. DRAWINGS STAMP
EQPT CURB TO FRAMEWORK N.T.S. 19 ROOF FRAMING PLAN UNDER MECH. UNIT CU-01 & CU-02 1" = 1'-0" 11 SECTION AT MECH. UNIT CU-01 & CU-02 1" = 1'-0" 3
SEE PLAN
2'-0" MAX.
(E) 4 x 14
NEW OPENING PER PLAN. 1
2"
Ø S.S. LAG SCREW @ 10" O.C.
SEE ARCH. FOR THE EXACT W/ MIN. 4" PENETRATION INTO
SIZE. 4x6 FRAMEWORK
(E) 2x
2x6
2x6
(E) 2x
4x BLK'G 4x BLK'G 4x BLK'G 4x BLK'G
(E) PLYWD. SHTG.
2x6
4
-
(N) 4x6
(N) 4x6
NOTE:
(E) 2x
(E) 2x
2x JOIST
MECH. EQUIPEMENT, SEE MECH. DWG
4"
4x BLK'G 4x BLK'G 4x BLK'G 4x BLK'G FOR LOCATION AND SIZE
2-16d FACE NAIL (2) ROWS OF SDS25300
2"
STUD TO HEADER @ 12" O.C. STAGG. PROJECT NO. 17X115.00
EA. END TYP.
PROVIDE 2-SDS PRINT DATE 3/16/2020
OPNG. 1
4" x 6" @ 4x KING (E) JOIST OR BEAM
STUD TYP. PER PLAN SECTION B DRAWN BY
CHECKED BY
(E) 4 x 14 (E) PLYWOOD SHTG.
SHEET TITLE
16
-
(2) ROWS OF SDS25300 @
FRAMING DETAILS
4"
2x KING STUD, TYP. 12" O.C. STAGG.
2"
TOP OF 2x TRIMMER, TYP. 2x JOIST S
ROOF (E) JOIST OR BEAM
RAISED WOOD PLATFORM PER 4/- PER PLAN SHEET NUMBER
NOTE: SECTION A
VERIFY DIMENSIONS & LOCATION W/ MECHANICAL AND ARCH. DWGS. NOTE:
ROOF FRAMING UNDER MECH. UNIT DOAS 1"=1'-0" 9 OPENING IN EXTERIOR WALL N.T.S. 5
CONNECTION W/ HUS26-2 W/ 4-16d AT EA. END.