Calculation 2023041100005-Columbia-RM-ground-2.64MW V0.1 20230411 (1)
Calculation 2023041100005-Columbia-RM-ground-2.64MW V0.1 20230411 (1)
2023041100005-JJ-Columbia-RM-ground-2.64MW
§ 1. References ………… 3
§ 2. Software ………… 3
§ 3. Design Conditions ………… 3
§ 4. Drawing ………… 3
§ 5. Structure's Material ………… 4
§ 6. Design Load ………… 4
6.1 Combinations of Load ………… 4
6.2 Dead Load ………… 4
6.3 Wind Load Calculations ………… 4
6.4 Snow Load Calculations ………… 9
§ 7. Load on sub rail ………… 11
§ 8. Dstructural analysis with SAP2000 V23 ………… 13
2
§ 1.References
Wind Load Design: ASCE/SEI 7-10
Snow Load Design: ANSI/AISC 360-16 AISI-ASD96
§ 2.Software
SAP 2000 V23(Structure Analysis Program 2000)
§ 3. Design Conditions
Module Dimension 2384 × 1303 × 35 mm
Module Weight 38.5 kg
ModuleOrientation Vertical
Module Layout 2 × 11 = 22 pcs
Tilt Angle 10 °
Basic Wind Speed 33.04 m/s (3s gust speed)
Ground Snow Loads 0 Kpa
Terrain Category C
Maximum Height 1.83143 m
Installation Site Ground
Design Standard ASCE 7-10
§ 4. Drawing
The condition of below drawing is the strictest in this project so the load calculation is only based on the below array.
3
§ 5. Structure's Material
§ 6. Design Load
6.1 Combination of Loads
The combination of loadind condition and shall be as given according to ASCE SATANDARD ASCE/SEI 7-10.
4
6.3 Wind Load Calculations
(1) Basic Wind Speed
The basic wind speed, V , used in the determination of design wind loads on buildings and
other structures.The wind shall be assumed to come from any horizontal direction.Values are
nominal design 3-second gust wind speeds in miles per hour (m/s) at 33 ft(10m) above ground
for Exposure C category.
Buildings
Square 0.9
Hexagonal 0.95
Round 0.95
Trussed Towers
1. The hill, ridge, or escarpment is isolated and unobstructed upwind by other similar
topographic features of comparable height for 100 times the height of the topographic feature
(100H) or 2 mi (3.22 km), whichever is less. This distance shall be measured horizontally
from the point at which the height H of the hill, ridge, or escarpment is determined.
2. The hill, ridge, or escarpment protrudes above the height of upwind terrain features
within a 2-mi (3.22 km) radius in any quadrant by a factor of two or more.
3. The structure is located as shown in Fig. 7-4 in the upper one-half of a hill or
ridge or near the crest of an escarpment.
4. H/Lh≥0.2.
5. H is greater than or equal to 15 ft (4.5 m) for Exposures C and D and 60 ft (18 m)
for Exposure B.
5
If site conditions and locations of structures do not meet all the conditions then
Kzt is taken as 1.0
(4) Velocity Pressure Exposure Coefficient
Velocity pressure exposure coefficient Kz shall be determined from Table 6-2. For a site
located in a transition zone between exposure categories, that is, near to a change in ground
surface roughness, intermediate values of Kz , between those shown in Table 6-2, are
permitted, provided that they are determined by a rational analysis method defined in the
recognized literature.Surface roughness categories are in Table 6-3.
Table 6-2
Exposure
Height above ground level, z
B C D
ft (m)
Table 6-3
Surface Roughness Categories
Surface Roughness
Urban and suburban areas, wooded areas, or other terrain with numerous closely spaced
B
obstructionshaving the size of single-family dwellings or larger.
Open terrain with scattered obstructions having heights generally less than 30 ft (9.1
C m). This category includes flat open country, grasslands, and all water surfaces in
hurricane prone regions.
Flat, unobstructed areas and water surfaces outside hurricane prone regions. This
D
category includes smooth mud flats, salt flats, and unbroken ice.
6
The height of this project is 1.83 m, and it belongs to exposure category C ,
So the Kz is taken as 0.85 .
(5) Velocity Pressure
Velocity pressure, qz, evaluated at height z shall be calculated by the following equation:
qz = 0.613 Kz Kzt Kd V2
0.613 0.85 0.85 33.04 2
= x x 1.0 x x
= 483.5 N/m2
Kd: wind directionality factor defi ned in Section = 0.85
Kzt: topographic factor defi ned in Section = 1.0
Kz: velocity pressure exposure coeffi cient defi ned inSection
= 0.85
V: Basic wind speed (m/s) = 33.04
Table 6-6
Wind Direction,γ=0° Wind Direction,γ=180°
Angel Load Case Clear Wind Flow Obstructed Wind Flow Clear Wind Flow Obstructed Wind Flow
7
Notes:
1. CNW and CNL denote net pressures (contributions from top and bottom surfaces) for windward
and leeward half of roof surfaces, respectively.
2. Clear wind flow denotes relatively unobstructed wind flow with blocltage less than or
equal to 50%. Obstructed wind flow denotes objects below roof inhibiting wind flow (>50%
blocltage).
3. For values of θ between 7.5°and 45°, linear interpolation is permitted. For values of θ
less than 7.5°, usemonoslope roof load coefficients.
4. Plus and minus signs signify pressures acting towards and away from the top roof surface,
respectively.
5. All load cases shown for each roof angle shall be investigated.
6. Notation:
L : horizontal dimension of roof, measured in the along wind direction, ft. (m)
h : mean roof height, ft. (m)
γ : direction of wind, degrees
θ : angle of plane of roof from horizontal, degrees
Free Roofs θ≤45°, = 90°, 270°
Notes:
1. CN denotes net pressures (contributions from top and bottom surfaces).
2. Clear wind flow denotes relatively unobstructed wind flow with blockage less than or equal
to 50%. Obstructed wind
flow denotes objects below roof inhibiting wind flow (>50% blockage).
3. Plus and minus signs signify pressures acting towards and away from the top roof surface,
respectively.
4. All load cases shown for each roof angle shall be investigated.
5. For monoslope roofs with theta less than 5 degrees, Cn values shown apply also for cases
where gamma = 0 degrees and
0.05 less than or equal to h/L less than or equal to 0.25. See Figure 27.4-4 for other h/L
values.
6. Notation:
L : horizontal dimension of roof, measured in the along wind direction, ft. (m)
h : mean roof height, ft. (m). See Figures 27.4-4, 27.4-5 or 27.4-6 for a graphical depiction
of this dimension.
γ : direction of wind, degrees
θ : angle of plane of roof from horizontal, degrees
8
where gamma = 0 degrees and
0.05 less than or equal to h/L less than or equal to 0.25. See Figure 27.4-4 for other h/L
values.
6. Notation:
L : horizontal dimension of roof, measured in the along wind direction, ft. (m)
h : mean roof height, ft. (m). See Figures 27.4-4, 27.4-5 or 27.4-6 for a graphical depiction
of this dimension.
γ : direction of wind, degrees
θ : angle of plane of roof from horizontal, degrees
CNW
Case A -0.3
10
Case B 0.3
CNW
Case A -123.2873687
10
Case B 123.2873687
B 0.9 1 1.2
C 0.9 1 1.1
D 0.8 0.9 1
9
In Alaska, in areas where trees do not exist within
0.7 0.8 N/A
a 2-mile (3-km) radius of the site.
The exposure condition of the solar photovoltaic bracket system is Fully Exposed,and it belongs to
exposure category
, C so the Ce is taken as 0.9 .
(3) Thermal Factor
The thermal factor Ct shall be determined from Table 6-8.
Table 6-8
Thermal Condition Ct
Structures kept just above freezing and others with cold, ventilated roofs in
which the thermal resistance (R-value) between the ventilated space and the 1.1
2 2
heated space exceeds 25° F x h x ft /Btu (0.4 K x m /w)
In the snowy condition,the solar photovoltaic bracket system belongs to the unheated
structures, so the Ct is taken as 1.2 .
An importance factor, I (snow loads), for the building or other structure shall be
determined from Table 6-9 based on building and structure categories listed in Table 6-5.
Table 6-9
Category Importance Factor Is
I 0.8
II 1.0
III 1.1
IV 1.2
Solar photovoltaic bracket system belongs to occupancy category I,so the I is taken 0.8
as
(5) Flat Roof Snow Loads
The snow load, Pf , on a roof with a slope equal to or less than 5° (1 in./ft = 4.76°)
shall be calculated in lb/ft2 (kN/m2) using the following formula:
Pf = 0.7𝐶𝑒 𝐶𝑡 𝐼𝑠 𝑃𝑔
10
(6) Roof Slope Factor
For cold roofs with Ct = 1.2 and an unobstructed slippery surface that will allow snow
to slide off the eaves, the roof slope factor Cs shall be determined using the dashed line on
Fig. 6-2c.
10 °, so the Cs is taken1.00
The setting angle of this project is as .
(7) Sloped Roof Snow Loads
Snow loads acting on a sloping surface shall be assumed to act on the horizontal
projection of that surface. The sloped roof snow load, Ps, shall be obtained by multiplying
the flat roof snow load, Pf , by the roof slope factor, Cs.
= 1.00 × 0.0
= 0.0 N/m2
Cs: Roof slope factor = 1.00
Pf: Flat roof snow loads = 0.0 N/m2
11
Case A -0.3429 -0.5388 0.5062 0.7511
10
Case B -0.7675 0.0000 0.8164 0.1959
(3)Snow Load
Load calculation for rail's Snow load:
Qs = Ps× B
= 0.00 × 2.384 / 2
= 0.00 N/m
= 0.0000 kN/m
12
8.Dstructural analysis with SAP2000 V23
8.1 Modeling (Modeling is at 3D model by stereo analysis)
Modeling is at 3D model by stereo analysis Span= 3400
Purlin
13
Column
Bracing
14
8.3 Load analysis
Dead load Long-term linear load = 0.1448 kN/m
15
Downwind load Case A, γ = 180° Linear upwind load = 0.506 / 0.751 kN/m
Downwind load Case B, γ = 180° Linear upwind load = 0.816 / 0.196 kN/m
16
8.3 Stress and deflection test
17
Bending moment of structure (strong axis)
18
Axial force diagram of the structure
Stress contour
Stress ratio
Max stress ratio is less than 1, which satisfies the strength
19
Beam stress ratio
20
Purlin stress ratio
21
Column stress ratio
22
Bracing stress ratio
23
8.4 Calculation of fulcrum reaction force
A. F1, F2 and F3 in the figure refer to forces in the X, Y and Z directions respectively;
B, M1, M2 and M3 refer to bending moments around X, Y and Z directions respectively;
C. The force between the foundation and the column is the relationship between the force and
the reaction force. When the column is subjected to downward tension, the foundation will be
subjected to upward pulling force.
Reaction of supports
Jonit Load cases F1 F2 F3 M1 M2 M3
Text Text kN kN kN kN-m kN-m kN-m
93 D 0.25 0.01 0.82 -0.03 0.05 0.00
93 D+S 0.25 0.01 0.82 -0.03 0.05 0.00
93 D+0.6W (Case A, γ = 0°) 0.15 -0.02 -0.39 0.03 0.09 0.00
93 D+0.6W (Case B, γ =180°) 0.36 0.05 2.58 -0.12 -0.01 -0.01
93 0.6D+0.6W (Case A, γ = 0°) 0.05 -0.02 -0.71 0.05 0.07 0.00
93 0.6D+0.6W (Case B, γ =180°) 0.26 0.04 2.25 -0.11 -0.03 -0.01
93 D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.18 -0.01 -0.08 0.02 0.08 0.00
93D+0.75*0.6W+0.75S (Case B, γ = 180°) 0.33 0.04 2.14 -0.10 0.00 -0.01
93 D+0.6W (Case B, γ = 0°) 0.13 -0.01 0.66 -0.01 0.06 -0.01
93 D+0.6W (Case A, γ =180°) 0.36 0.05 2.58 -0.12 -0.01 -0.01
93 0.6D+0.6W (Case B, γ = 0°) 0.03 -0.02 0.34 0.01 0.04 -0.01
93 0.6D+0.6W (Case A, γ =180°) 0.32 0.05 1.71 -0.10 -0.02 0.00
93 D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.16 0.00 0.70 -0.01 0.06 -0.01
93D+0.75*0.6W+0.75S (Case A, γ = 180°) 0.38 0.04 1.74 -0.09 0.01 0.00
95 D -0.23 0.01 0.76 -0.03 -0.11 0.00
24
95 D+S -0.23 0.01 0.76 -0.03 -0.11 0.00
95 D+0.6W (Case A, γ = 0°) 0.26 0.00 -0.17 0.01 0.14 0.00
95 D+0.6W (Case B, γ =180°) -0.78 0.01 1.45 -0.06 -0.41 -0.01
95 0.6D+0.6W (Case A, γ = 0°) 0.35 0.00 -0.48 0.02 0.19 0.00
95 0.6D+0.6W (Case B, γ =180°) -0.69 0.01 1.14 -0.05 -0.36 -0.01
95 D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.13 0.00 0.06 0.00 0.08 0.00
95D+0.75*0.6W+0.75S (Case B, γ = 180°) -0.64 0.01 1.28 -0.06 -0.33 -0.01
95 D+0.6W (Case B, γ = 0°) 0.21 0.00 -0.95 0.03 0.11 0.00
95 D+0.6W (Case A, γ =180°) -0.78 0.01 1.45 -0.06 -0.41 -0.01
95 0.6D+0.6W (Case B, γ = 0°) 0.30 0.00 -1.25 0.04 0.16 0.00
95 0.6D+0.6W (Case A, γ =180°) -0.84 0.01 2.28 -0.09 -0.44 -0.01
95 D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.10 0.00 -0.52 0.02 0.05 0.00
95D+0.75*0.6W+0.75S (Case A, γ = 180°) -0.75 0.01 2.13 -0.08 -0.39 -0.01
113 D 0.37 0.00 1.31 -0.03 0.06 0.00
113 D+S 0.37 0.00 1.31 -0.03 0.06 0.00
113 D+0.6W (Case A, γ = 0°) 0.19 0.00 -0.76 0.03 0.13 0.00
113 D+0.6W (Case B, γ =180°) 0.56 -0.02 4.33 -0.11 -0.04 -0.01
113 0.6D+0.6W (Case A, γ = 0°) 0.04 0.00 -1.29 0.04 0.11 0.00
113 0.6D+0.6W (Case B, γ =180°) 0.41 -0.02 3.81 -0.10 -0.06 -0.01
113D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.24 0.00 -0.25 0.01 0.11 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) 0.51
113 -0.02 3.58 -0.09 -0.01 -0.01
113 D+0.6W (Case B, γ = 0°) 0.17 -0.02 1.04 0.00 0.09 -0.01
113 D+0.6W (Case A, γ =180°) 0.56 -0.02 4.33 -0.11 -0.04 -0.01
113 0.6D+0.6W (Case B, γ = 0°) 0.03 -0.02 0.52 0.01 0.07 -0.01
113 0.6D+0.6W (Case A, γ =180°) 0.50 0.00 2.88 -0.09 -0.05 0.00
113D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.22 -0.02 1.11 -0.01 0.08 -0.01
D+0.75*0.6W+0.75S (Case A, γ = 180°) 0.58
113 0.00 2.88 -0.09 -0.01 0.00
115 D -0.39 -0.01 1.22 -0.02 -0.20 0.00
115 D+S -0.39 -0.01 1.22 -0.02 -0.20 0.00
115 D+0.6W (Case A, γ = 0°) 0.42 0.01 -0.36 0.01 0.23 0.00
115 D+0.6W (Case B, γ =180°) -1.31 -0.02 2.38 -0.05 -0.69 0.00
115 0.6D+0.6W (Case A, γ = 0°) 0.58 0.01 -0.85 0.02 0.31 0.00
115 0.6D+0.6W (Case B, γ =180°) -1.15 -0.02 1.89 -0.04 -0.61 0.00
115D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.22 0.00 0.03 0.00 0.12 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) -1.08
115 -0.02 2.09 -0.04 -0.56 0.00
115 D+0.6W (Case B, γ = 0°) 0.36 0.03 -1.69 0.02 0.19 0.00
115 D+0.6W (Case A, γ =180°) -1.31 -0.02 2.38 -0.05 -0.69 0.00
115 0.6D+0.6W (Case B, γ = 0°) 0.52 0.03 -2.18 0.03 0.27 0.00
115 0.6D+0.6W (Case A, γ =180°) -1.42 -0.04 3.84 -0.06 -0.74 0.00
115D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.17 0.02 -0.97 0.01 0.09 0.00
D+0.75*0.6W+0.75S (Case A, γ = 180°) -1.28
115 -0.04 3.55 -0.06 -0.66 0.00
129 D 0.38 0.00 1.27 -0.03 0.06 0.00
129 D+S 0.38 0.00 1.27 -0.03 0.06 0.00
25
129 D+0.6W (Case A, γ = 0°) 0.20 0.00 -0.72 0.02 0.13 0.00
129 D+0.6W (Case B, γ =180°) 0.56 -0.02 4.18 -0.11 -0.03 -0.01
129 0.6D+0.6W (Case A, γ = 0°) 0.05 0.00 -1.23 0.04 0.11 0.00
129 0.6D+0.6W (Case B, γ =180°) 0.41 -0.02 3.67 -0.10 -0.06 -0.01
129D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.25 0.00 -0.22 0.01 0.12 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) 0.51
129 -0.01 3.45 -0.09 -0.01 -0.01
129 D+0.6W (Case B, γ = 0°) 0.19 -0.02 1.01 -0.01 0.09 -0.01
129 D+0.6W (Case A, γ =180°) 0.56 -0.02 4.18 -0.11 -0.03 -0.01
129 0.6D+0.6W (Case B, γ = 0°) 0.03 -0.02 0.51 0.01 0.07 -0.01
129 0.6D+0.6W (Case A, γ =180°) 0.50 0.01 2.78 -0.09 -0.05 0.00
129D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.23 -0.02 1.08 -0.01 0.09 -0.01
D+0.75*0.6W+0.75S (Case A, γ = 180°) 0.58
129 0.00 2.78 -0.09 0.00 0.00
131 D -0.37 -0.01 1.17 -0.02 -0.19 0.00
131 D+S -0.37 -0.01 1.17 -0.02 -0.19 0.00
131 D+0.6W (Case A, γ = 0°) 0.42 0.01 -0.35 0.01 0.23 0.00
131 D+0.6W (Case B, γ =180°) -1.27 -0.02 2.30 -0.05 -0.67 0.00
131 0.6D+0.6W (Case A, γ = 0°) 0.57 0.01 -0.82 0.02 0.31 0.00
131 0.6D+0.6W (Case B, γ =180°) -1.12 -0.01 1.83 -0.04 -0.59 0.00
131D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.22 0.00 0.03 0.00 0.13 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) -1.05
131 -0.02 2.02 -0.04 -0.55 0.00
131 D+0.6W (Case B, γ = 0°) 0.36 0.02 -1.63 0.02 0.19 0.00
131 D+0.6W (Case A, γ =180°) -1.27 -0.02 2.30 -0.05 -0.67 0.00
131 0.6D+0.6W (Case B, γ = 0°) 0.51 0.03 -2.10 0.03 0.27 0.00
131 0.6D+0.6W (Case A, γ =180°) -1.38 -0.04 3.70 -0.06 -0.72 0.00
131D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.18 0.02 -0.93 0.01 0.10 0.00
D+0.75*0.6W+0.75S (Case A, γ = 180°) -1.24
131 -0.03 3.42 -0.06 -0.64 0.00
145 D 0.37 0.00 1.30 -0.03 0.06 0.00
145 D+S 0.37 0.00 1.30 -0.03 0.06 0.00
145 D+0.6W (Case A, γ = 0°) 0.19 0.00 -0.76 0.02 0.13 0.00
145 D+0.6W (Case B, γ =180°) 0.56 -0.02 4.31 -0.11 -0.04 -0.01
145 0.6D+0.6W (Case A, γ = 0°) 0.04 0.01 -1.28 0.04 0.11 0.00
145 0.6D+0.6W (Case B, γ =180°) 0.41 -0.02 3.79 -0.10 -0.06 -0.01
145D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.24 0.00 -0.24 0.01 0.11 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) 0.51
145 -0.02 3.55 -0.09 -0.01 -0.01
145 D+0.6W (Case B, γ = 0°) 0.17 -0.02 1.04 -0.01 0.09 -0.01
145 D+0.6W (Case A, γ =180°) 0.56 -0.02 4.31 -0.11 -0.04 -0.01
145 0.6D+0.6W (Case B, γ = 0°) 0.02 -0.02 0.52 0.01 0.06 -0.01
145 0.6D+0.6W (Case A, γ =180°) 0.50 0.00 2.86 -0.09 -0.05 0.00
145D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.22 -0.02 1.10 -0.01 0.08 -0.01
D+0.75*0.6W+0.75S (Case A, γ = 180°) 0.58
145 0.00 2.86 -0.09 0.00 0.00
147 D -0.39 -0.01 1.21 -0.02 -0.20 0.00
147 D+S -0.39 -0.01 1.21 -0.02 -0.20 0.00
147 D+0.6W (Case A, γ = 0°) 0.42 0.01 -0.36 0.01 0.23 0.00
26
147 D+0.6W (Case B, γ =180°) -1.30 -0.02 2.37 -0.05 -0.68 0.00
147 0.6D+0.6W (Case A, γ = 0°) 0.58 0.01 -0.84 0.02 0.31 0.00
147 0.6D+0.6W (Case B, γ =180°) -1.14 -0.02 1.88 -0.04 -0.60 0.00
147D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.22 0.00 0.03 0.00 0.12 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) -1.07
147 -0.02 2.08 -0.04 -0.56 0.00
147 D+0.6W (Case B, γ = 0°) 0.36 0.02 -1.68 0.02 0.19 0.00
147 D+0.6W (Case A, γ =180°) -1.30 -0.02 2.37 -0.05 -0.68 0.00
147 0.6D+0.6W (Case B, γ = 0°) 0.51 0.03 -2.17 0.03 0.27 0.00
147 0.6D+0.6W (Case A, γ =180°) -1.41 -0.04 3.81 -0.06 -0.73 0.00
147D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.17 0.02 -0.96 0.01 0.09 0.00
D+0.75*0.6W+0.75S (Case A, γ = 180°) -1.27
147 -0.04 3.53 -0.06 -0.66 0.00
161 D 0.25 0.02 0.85 -0.04 0.04 0.00
161 D+S 0.25 0.02 0.85 -0.04 0.04 0.00
161 D+0.6W (Case A, γ = 0°) 0.15 -0.01 -0.41 0.02 0.09 0.00
161 D+0.6W (Case B, γ =180°) 0.36 0.05 2.68 -0.13 -0.02 -0.01
161 0.6D+0.6W (Case A, γ = 0°) 0.05 -0.01 -0.75 0.04 0.07 0.00
161 0.6D+0.6W (Case B, γ =180°) 0.26 0.04 2.34 -0.11 -0.04 -0.01
161D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.18 0.00 -0.10 0.01 0.08 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) 0.33
161 0.04 2.22 -0.11 0.00 -0.01
161 D+0.6W (Case B, γ = 0°) 0.15 0.00 0.69 -0.01 0.07 -0.01
161 D+0.6W (Case A, γ =180°) 0.36 0.05 2.68 -0.13 -0.02 -0.01
161 0.6D+0.6W (Case B, γ = 0°) 0.05 -0.01 0.36 0.00 0.05 -0.01
161 0.6D+0.6W (Case A, γ =180°) 0.30 0.05 1.77 -0.10 -0.03 0.00
161D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.17 0.00 0.73 -0.02 0.06 -0.01
D+0.75*0.6W+0.75S (Case A, γ = 180°) 0.37
161 0.05 1.79 -0.10 0.00 0.00
163 D -0.24 0.00 0.79 -0.02 -0.12 0.00
163 D+S -0.24 0.00 0.79 -0.02 -0.12 0.00
163 D+0.6W (Case A, γ = 0°) 0.26 0.00 -0.18 0.01 0.15 0.00
163 D+0.6W (Case B, γ =180°) -0.81 0.01 1.50 -0.06 -0.43 -0.01
163 0.6D+0.6W (Case A, γ = 0°) 0.36 0.00 -0.50 0.02 0.19 0.00
163 0.6D+0.6W (Case B, γ =180°) -0.72 0.01 1.19 -0.05 -0.38 -0.01
163D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.14 0.00 0.06 0.00 0.08 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) -0.67
163 0.01 1.32 -0.05 -0.35 -0.01
163 D+0.6W (Case B, γ = 0°) 0.22 0.00 -0.99 0.03 0.12 0.00
163 D+0.6W (Case A, γ =180°) -0.81 0.01 1.50 -0.06 -0.43 -0.01
163 0.6D+0.6W (Case B, γ = 0°) 0.32 0.00 -1.31 0.04 0.17 0.00
163 0.6D+0.6W (Case A, γ =180°) -0.88 0.00 2.37 -0.08 -0.46 -0.01
163D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.11 0.00 -0.55 0.02 0.06 0.00
D+0.75*0.6W+0.75S (Case A, γ = 180°) -0.80
163 0.00 2.21 -0.08 -0.41 -0.01
27