Load Calculation For Solar Mounting System

2023041100005-JJ-Columbia-RM-ground-2.64MW

Version Date Issued Reviewed Approved


V0.1 2023-04-11 Jing Minter Minter

Antai Technology Co., Ltd.


CONTENTS

§ 1. References ………… 3
§ 2. Software ………… 3
§ 3. Design Conditions ………… 3
§ 4. Drawing ………… 3
§ 5. Structure's Material ………… 4
§ 6. Design Load ………… 4
6.1 Combinations of Load ………… 4
6.2 Dead Load ………… 4
6.3 Wind Load Calculations ………… 4
6.4 Snow Load Calculations ………… 9
§ 7. Load on sub rail ………… 11
§ 8. Dstructural analysis with SAP2000 V23 ………… 13

2
§ 1.References
Wind Load Design: ASCE/SEI 7-10
Snow Load Design: ANSI/AISC 360-16 AISI-ASD96

§ 2.Software
SAP 2000 V23(Structure Analysis Program 2000)

§ 3. Design Conditions
Module Dimension 2384 × 1303 × 35 mm
Module Weight 38.5 kg
ModuleOrientation Vertical
Module Layout 2 × 11 = 22 pcs
Tilt Angle 10 °
Basic Wind Speed 33.04 m/s (3s gust speed)
Ground Snow Loads 0 Kpa
Terrain Category C
Maximum Height 1.83143 m
Installation Site Ground
Design Standard ASCE 7-10

§ 4. Drawing
The condition of below drawing is the strictest in this project so the load calculation is only based on the below array.

3
§ 5. Structure's Material

material Minimum tensile Minimum Yield strength Density Young’s


properties strength fu(MPa): fy(MPa): (kg/m^3): Modulus(MPa):

8.8 Carbon 800 600 7850 210000

Q235 Steel 370 235 7850 210000

Q355 Steel 470 355 7850 210000

Q420 Steel 520 420 7850 210000

Q500 Steel 610 500 7850 210000

S250GD 330 250 7850 210000

S350GD 420 350 7850 210000

S390GD 470 390 7850 210000

S420GD 480 420 7850 210000

S500GD 580 500 7850 210000

§ 6. Design Load
6.1 Combination of Loads
The combination of loadind condition and shall be as given according to ASCE SATANDARD ASCE/SEI 7-10.

D: Dead Load S: Snow Load W: Wind Load

6.2 Dead Load

Frame weight: Automatic weight calculation software

The acceleration of gravity: g = 9.8 m/s2

Dead load of module (N) : G = 38.50 kg x 9.8 m/s2 = 377.3 N

The module area(m2) S = 2.384 x 1.303 = 3.106 m2

Pressure of module (N/m2) : D = G / S = 121.46 N/m2

4
6.3 Wind Load Calculations
(1) Basic Wind Speed

The basic wind speed, V , used in the determination of design wind loads on buildings and
other structures.The wind shall be assumed to come from any horizontal direction.Values are
nominal design 3-second gust wind speeds in miles per hour (m/s) at 33 ft(10m) above ground
for Exposure C category.

Wind speed is 33.04 m/s


(2) Wind Directionality Factor
The wind directionality factor Kd shall be determined from Table 6-1. This factor shall only
be applied when used in conjunction with load combinations.
Solar photovoltaic bracket system belongs to main wind force resisting system,so the Kd
is taken as 0.85
Table 6-1
Structure Type Directionality Factor Kd

Buildings

Main Wind Force Resisting System 0.85

Components and Cladding 0.85

Arched Roofs 0.85

Chimneys, Tanks, and Similar Structures

Square 0.9

Hexagonal 0.95

Round 0.95

Solid Freestanding Walls and Solid 0.85


Freestanding and Attached Signs

Open Signs and Lattice Framework 0.85

Trussed Towers

Triangular, square, rectangular 0.85

All other cross sections 0.95

(3) Topographic Factor


Wind speed-up effects at isolated hills, ridges,and escarpments constituting abrupt changes
in the general topography, located in any exposure category,shall be included in the design
when buildings and other site conditions and locations of structures meetall of the following
conditions:

1. The hill, ridge, or escarpment is isolated and unobstructed upwind by other similar
topographic features of comparable height for 100 times the height of the topographic feature
(100H) or 2 mi (3.22 km), whichever is less. This distance shall be measured horizontally
from the point at which the height H of the hill, ridge, or escarpment is determined.

2. The hill, ridge, or escarpment protrudes above the height of upwind terrain features
within a 2-mi (3.22 km) radius in any quadrant by a factor of two or more.

3. The structure is located as shown in Fig. 7-4 in the upper one-half of a hill or
ridge or near the crest of an escarpment.
4. H/Lh≥0.2.
5. H is greater than or equal to 15 ft (4.5 m) for Exposures C and D and 60 ft (18 m)
for Exposure B.

5
If site conditions and locations of structures do not meet all the conditions then
Kzt is taken as 1.0
(4) Velocity Pressure Exposure Coefficient
Velocity pressure exposure coefficient Kz shall be determined from Table 6-2. For a site
located in a transition zone between exposure categories, that is, near to a change in ground
surface roughness, intermediate values of Kz , between those shown in Table 6-2, are
permitted, provided that they are determined by a rational analysis method defined in the
recognized literature.Surface roughness categories are in Table 6-3.
Table 6-2
Exposure
Height above ground level, z

B C D
ft (m)

0-15 (0-4.6) 0.57 0.85 1.03

20 6.096 0.62 0.90 1.08

25 7.62 0.66 0.94 1.12

30 9.144 0.70 0.98 1.16

40 12.192 0.76 1.04 1.22

50 15.24 0.81 1.09 1.27

60 18.288 0.85 1.13 1.31

70 21.336 0.89 1.17 1.34

80 24.384 0.93 1.21 1.38

90 27.432 0.96 1.24 1.4

100 30.48 0.99 1.26 1.43

120 36.6 1.04 1.31 1.48

140 42.7 1.09 1.36 1.52

160 48.8 1.13 1.39 1.55

180 54.9 1.17 1.43 1.58

200 61 1.20 1.46 1.61

250 76.2 1.28 1.53 1.68

300 91.4 1.35 1.59 1.73

350 106.7 1.41 1.64 1.78

400 121.9 1.47 1.69 1.82

450 137.2 1.52 1.73 1.86

500 152.4 1.56 1.77 1.89

Table 6-3
Surface Roughness Categories

Surface Roughness

Urban and suburban areas, wooded areas, or other terrain with numerous closely spaced
B
obstructionshaving the size of single-family dwellings or larger.

Open terrain with scattered obstructions having heights generally less than 30 ft (9.1
C m). This category includes flat open country, grasslands, and all water surfaces in
hurricane prone regions.

Flat, unobstructed areas and water surfaces outside hurricane prone regions. This
D
category includes smooth mud flats, salt flats, and unbroken ice.

6
The height of this project is 1.83 m, and it belongs to exposure category C ,
So the Kz is taken as 0.85 .
(5) Velocity Pressure
Velocity pressure, qz, evaluated at height z shall be calculated by the following equation:
qz = 0.613 Kz Kzt Kd V2
0.613 0.85 0.85 33.04 2
= x x 1.0 x x
= 483.5 N/m2
Kd: wind directionality factor defi ned in Section = 0.85
Kzt: topographic factor defi ned in Section = 1.0
Kz: velocity pressure exposure coeffi cient defi ned inSection
= 0.85
V: Basic wind speed (m/s) = 33.04

(6) Gust Effect Factor


0.85as
For rigid structures , the gust-effect factor G shall be taken

(7) Net Pressure Coefficient


Net pressure coefficients CN include contributions from top and bottom surfaces.

Table 6-6
Wind Direction,γ=0° Wind Direction,γ=180°

Angel Load Case Clear Wind Flow Obstructed Wind Flow Clear Wind Flow Obstructed Wind Flow

CNW CNL CNW CNL CNW CNL CNW CNL

A 1.2 0.3 -0.5 -1.2 1.2 0.3 -0.5 -1.2


0
B -1.1 -0.1 -1.1 -0.6 -1.1 -0.1 -1.1 -0.6

A -0.6 -1 -1 -1.5 0.9 1.5 -0.2 -1.2


7.5
B -1.4 0 -1.7 -0.8 1.6 0.3 0.8 -0.3

A -0.9 -1.3 -1.1 -1.5 1.3 1.6 0.4 -1.1


15
B -1.9 0 -2.1 -0.6 1.8 0.6 1.2 -0.3

A -1.5 -1.6 -1.5 -1.7 1.7 1.8 0.5 -1


22.5
B -2.4 -0.3 -2.3 -0.9 2.2 0.7 1.3 0

A -1.8 -1.8 -1.5 -1.8 2.1 2.1 0.6 -1


30
B -2.5 -0.5 -2.3 -1.1 2.6 1 1.6 0.1

A -1.8 -1.8 -1.5 -1.8 2.1 2.2 0.7 -0.9


37.5
B -2.4 -0.6 -2.2 -1.1 2.7 1.1 1.9 0.3

A -1.6 -1.8 -1.3 -1.8 2.2 2.5 0.8 -0.9


45
B -2.3 -0.7 -1.9 -1.2 2.6 1.4 2.1 0.4

7
Notes:
1. CNW and CNL denote net pressures (contributions from top and bottom surfaces) for windward
and leeward half of roof surfaces, respectively.
2. Clear wind flow denotes relatively unobstructed wind flow with blocltage less than or
equal to 50%. Obstructed wind flow denotes objects below roof inhibiting wind flow (>50%
blocltage).
3. For values of θ between 7.5°and 45°, linear interpolation is permitted. For values of θ
less than 7.5°, usemonoslope roof load coefficients.

4. Plus and minus signs signify pressures acting towards and away from the top roof surface,
respectively.

5. All load cases shown for each roof angle shall be investigated.
6. Notation:
L : horizontal dimension of roof, measured in the along wind direction, ft. (m)
h : mean roof height, ft. (m)
γ : direction of wind, degrees
θ : angle of plane of roof from horizontal, degrees
Free Roofs θ≤45°, = 90°, 270°

Horizontal Clear WindFlow ObstructedWind Flow


Distance from Roof Angle θ Load Case
Windward Edge CN CN

All Shapes A -0.8 -1.2


< h
θ≤45° B 0.8 0.5

All Shapes A -0.6 -0.9


< h,≤2h
θ≤45° B 0.5 0.5

All Shapes A -0.3 -0.6


>2 h
θ≤45° B 0.3 0.3

Notes:
1. CN denotes net pressures (contributions from top and bottom surfaces).
2. Clear wind flow denotes relatively unobstructed wind flow with blockage less than or equal
to 50%. Obstructed wind
flow denotes objects below roof inhibiting wind flow (>50% blockage).
3. Plus and minus signs signify pressures acting towards and away from the top roof surface,
respectively.
4. All load cases shown for each roof angle shall be investigated.
5. For monoslope roofs with theta less than 5 degrees, Cn values shown apply also for cases
where gamma = 0 degrees and
0.05 less than or equal to h/L less than or equal to 0.25. See Figure 27.4-4 for other h/L
values.
6. Notation:
L : horizontal dimension of roof, measured in the along wind direction, ft. (m)
h : mean roof height, ft. (m). See Figures 27.4-4, 27.4-5 or 27.4-6 for a graphical depiction
of this dimension.
γ : direction of wind, degrees
θ : angle of plane of roof from horizontal, degrees
8
where gamma = 0 degrees and
0.05 less than or equal to h/L less than or equal to 0.25. See Figure 27.4-4 for other h/L
values.
6. Notation:
L : horizontal dimension of roof, measured in the along wind direction, ft. (m)
h : mean roof height, ft. (m). See Figures 27.4-4, 27.4-5 or 27.4-6 for a graphical depiction
of this dimension.
γ : direction of wind, degrees
θ : angle of plane of roof from horizontal, degrees

The setting angle is 10 °


Wind Direction, γ = 0° Wind Direction, γ =180°

setting angle θ Clear Wind Flow Clear Wind Flow

CNW CNL CNW CNL

Case A -0.700 -1.100 1.033 1.533


10
Case B -1.567 0.000 1.667 0.400

Wind Direction, γ = 90°, 270°

setting angle θ Clear Wind Flow

CNW

Case A -0.3
10
Case B 0.3

(9) Net Design Pressure


Net design pressure, p, shall be calculated by the following equation:
P=qZGCN
Wind Direction, γ = 0° Wind Direction, 180°
setting angle θ
PNW PNL PNW PNL

Case A -287.7 -452.1 424.7 630.1


10
Case B -643.8 0.0 684.9 164.4

Wind Direction, γ = 90°, 270°

setting angle θ Clear Wind Flow

CNW

Case A -123.2873687
10
Case B 123.2873687

6.4 Snow Load Calculations


(1) Ground Snow Loads
Ground snow loads, Pg,to be used in the determination of design snow loads for roofs.
Ground snow loads Pg is 0.00 Kpa,equals to 0 N/m2.
(2) Exposure Factor
The exposure factor Ce shall be determined from Table 6-7.
Table 6-7
Terrain Category Fully Exposed Partially Exposed Sheltered

B 0.9 1 1.2

C 0.9 1 1.1

D 0.8 0.9 1

Above the treeline in windswept mountainous areas. 0.7 0.8 N/A

9
In Alaska, in areas where trees do not exist within
0.7 0.8 N/A
a 2-mile (3-km) radius of the site.

The exposure condition of the solar photovoltaic bracket system is Fully Exposed,and it belongs to
exposure category
, C so the Ce is taken as 0.9 .
(3) Thermal Factor
The thermal factor Ct shall be determined from Table 6-8.
Table 6-8
Thermal Condition Ct

All structures except as indicated below 1.0

Structures kept just above freezing and others with cold, ventilated roofs in
which the thermal resistance (R-value) between the ventilated space and the 1.1
2 2
heated space exceeds 25° F x h x ft /Btu (0.4 K x m /w)

Unheated and open air structures 1.2

Structures intentionally kept below freezing 1.3

Continuously heated greenhouses with a roof having a thermal resistance (R-value)


2 2 0.85
less than 2.0°Fx hx ft /Btu (0.4 K x m /w)

In the snowy condition,the solar photovoltaic bracket system belongs to the unheated
structures, so the Ct is taken as 1.2 .

(4) Importance Factor

An importance factor, I (snow loads), for the building or other structure shall be
determined from Table 6-9 based on building and structure categories listed in Table 6-5.

Table 6-9
Category Importance Factor Is

I 0.8

II 1.0

III 1.1

IV 1.2

Solar photovoltaic bracket system belongs to occupancy category I,so the I is taken 0.8
as
(5) Flat Roof Snow Loads
The snow load, Pf , on a roof with a slope equal to or less than 5° (1 in./ft = 4.76°)
shall be calculated in lb/ft2 (kN/m2) using the following formula:
Pf = 0.7𝐶𝑒 𝐶𝑡 𝐼𝑠 𝑃𝑔

= 0.7 × 0.9 × 1.2 × 0.8 × 0


0.0 2
= N/m
Ce: Exposure factor = 0.9
Ct: Thermal factor = 1.2
Is: Importance factor = 0.8
Pg: Ground snow loads = 0 N/m2

10
(6) Roof Slope Factor
For cold roofs with Ct = 1.2 and an unobstructed slippery surface that will allow snow
to slide off the eaves, the roof slope factor Cs shall be determined using the dashed line on
Fig. 6-2c.

10 °, so the Cs is taken1.00
The setting angle of this project is as .
(7) Sloped Roof Snow Loads

Snow loads acting on a sloping surface shall be assumed to act on the horizontal
projection of that surface. The sloped roof snow load, Ps, shall be obtained by multiplying
the flat roof snow load, Pf , by the roof slope factor, Cs.

= 1.00 × 0.0
= 0.0 N/m2
Cs: Roof slope factor = 1.00
Pf: Flat roof snow loads = 0.0 N/m2

7. Load on Sub Rail


7.1.1 Load Calculation
Under the Fixed Load on rails

(1) Fixed Load


Load calculation for rail's fixed load:
Qg = Qg× B
= 121.46 × 2.384 / 2
= 144.78 N/m
= 0.1448 kN/m
(2)Wind Load
Load calculation for rail's wind load:
Wind Direction, γ = 0° Wind Direction, 180°
setting angle θ
WNW WNL WNW WNL

11
Case A -0.3429 -0.5388 0.5062 0.7511
10
Case B -0.7675 0.0000 0.8164 0.1959

(3)Snow Load
Load calculation for rail's Snow load:
Qs = Ps× B
= 0.00 × 2.384 / 2
= 0.00 N/m
= 0.0000 kN/m

7.1.2 Load Combinations

Load Combinations Of Rail kN/m

Fixed Load-D 0.1448

Snow Load-S 0.0000

Wind Direction, γ = 0° Wind Direction, 180°


Load Wind Load-W
WNW WNL WNW WNL

Case A -0.3429 -0.5388 0.5062 0.7511

Case B -0.7675 0.0000 0.8164 0.1959

12
8.Dstructural analysis with SAP2000 V23
8.1 Modeling (Modeling is at 3D model by stereo analysis)
Modeling is at 3D model by stereo analysis Span= 3400

8.2 Cross Sections of Members


Beam

Purlin

13
Column

Bracing

14
8.3 Load analysis
Dead load Long-term linear load = 0.1448 kN/m

Downwind load Case A, γ = 0° Linear downwind load =-0.343 / -0.539 kN/m

Upwind load Case B, γ = 0° Linear upwind load -0.767


= / 0.0000 kN/m

15
Downwind load Case A, γ = 180° Linear upwind load = 0.506 / 0.751 kN/m

Downwind load Case B, γ = 180° Linear upwind load = 0.816 / 0.196 kN/m

Snow Load-S Linear load Qs = 0.0000 kN/m

16
8.3 Stress and deflection test

Max stress ratio 0.782 <1,ok

17
Bending moment of structure (strong axis)

Bending moment of structure (weak axis)

Shear force diagram of the structure (strong axis)

Shear force diagram of the structure (weak axis)

18
Axial force diagram of the structure

Stress contour

Stress ratio
Max stress ratio is less than 1, which satisfies the strength

19
Beam stress ratio

20
Purlin stress ratio

21
Column stress ratio

22
Bracing stress ratio

23
8.4 Calculation of fulcrum reaction force

A. F1, F2 and F3 in the figure refer to forces in the X, Y and Z directions respectively;
B, M1, M2 and M3 refer to bending moments around X, Y and Z directions respectively;

C. The force between the foundation and the column is the relationship between the force and
the reaction force. When the column is subjected to downward tension, the foundation will be
subjected to upward pulling force.

Maximum fulcrum reaction force list


Jonit Value Unit
Maximum vertical fulcrum reaction force (pulling out) 115 -2.18 kN
Maximum vertical fulcrum reaction force (push) 113 4.33 kN
Maximum horizontal fulcrum reaction force (east-west) 25 0.05 kN
Maximum horizontal fulcrum reaction force (north and south) 115 1.42 kN

Reaction of supports
Jonit Load cases F1 F2 F3 M1 M2 M3
Text Text kN kN kN kN-m kN-m kN-m
93 D 0.25 0.01 0.82 -0.03 0.05 0.00
93 D+S 0.25 0.01 0.82 -0.03 0.05 0.00
93 D+0.6W (Case A, γ = 0°) 0.15 -0.02 -0.39 0.03 0.09 0.00
93 D+0.6W (Case B, γ =180°) 0.36 0.05 2.58 -0.12 -0.01 -0.01
93 0.6D+0.6W (Case A, γ = 0°) 0.05 -0.02 -0.71 0.05 0.07 0.00
93 0.6D+0.6W (Case B, γ =180°) 0.26 0.04 2.25 -0.11 -0.03 -0.01
93 D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.18 -0.01 -0.08 0.02 0.08 0.00
93D+0.75*0.6W+0.75S (Case B, γ = 180°) 0.33 0.04 2.14 -0.10 0.00 -0.01
93 D+0.6W (Case B, γ = 0°) 0.13 -0.01 0.66 -0.01 0.06 -0.01
93 D+0.6W (Case A, γ =180°) 0.36 0.05 2.58 -0.12 -0.01 -0.01
93 0.6D+0.6W (Case B, γ = 0°) 0.03 -0.02 0.34 0.01 0.04 -0.01
93 0.6D+0.6W (Case A, γ =180°) 0.32 0.05 1.71 -0.10 -0.02 0.00
93 D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.16 0.00 0.70 -0.01 0.06 -0.01
93D+0.75*0.6W+0.75S (Case A, γ = 180°) 0.38 0.04 1.74 -0.09 0.01 0.00
95 D -0.23 0.01 0.76 -0.03 -0.11 0.00

24
95 D+S -0.23 0.01 0.76 -0.03 -0.11 0.00
95 D+0.6W (Case A, γ = 0°) 0.26 0.00 -0.17 0.01 0.14 0.00
95 D+0.6W (Case B, γ =180°) -0.78 0.01 1.45 -0.06 -0.41 -0.01
95 0.6D+0.6W (Case A, γ = 0°) 0.35 0.00 -0.48 0.02 0.19 0.00
95 0.6D+0.6W (Case B, γ =180°) -0.69 0.01 1.14 -0.05 -0.36 -0.01
95 D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.13 0.00 0.06 0.00 0.08 0.00
95D+0.75*0.6W+0.75S (Case B, γ = 180°) -0.64 0.01 1.28 -0.06 -0.33 -0.01
95 D+0.6W (Case B, γ = 0°) 0.21 0.00 -0.95 0.03 0.11 0.00
95 D+0.6W (Case A, γ =180°) -0.78 0.01 1.45 -0.06 -0.41 -0.01
95 0.6D+0.6W (Case B, γ = 0°) 0.30 0.00 -1.25 0.04 0.16 0.00
95 0.6D+0.6W (Case A, γ =180°) -0.84 0.01 2.28 -0.09 -0.44 -0.01
95 D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.10 0.00 -0.52 0.02 0.05 0.00
95D+0.75*0.6W+0.75S (Case A, γ = 180°) -0.75 0.01 2.13 -0.08 -0.39 -0.01
113 D 0.37 0.00 1.31 -0.03 0.06 0.00
113 D+S 0.37 0.00 1.31 -0.03 0.06 0.00
113 D+0.6W (Case A, γ = 0°) 0.19 0.00 -0.76 0.03 0.13 0.00
113 D+0.6W (Case B, γ =180°) 0.56 -0.02 4.33 -0.11 -0.04 -0.01
113 0.6D+0.6W (Case A, γ = 0°) 0.04 0.00 -1.29 0.04 0.11 0.00
113 0.6D+0.6W (Case B, γ =180°) 0.41 -0.02 3.81 -0.10 -0.06 -0.01
113D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.24 0.00 -0.25 0.01 0.11 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) 0.51
113 -0.02 3.58 -0.09 -0.01 -0.01
113 D+0.6W (Case B, γ = 0°) 0.17 -0.02 1.04 0.00 0.09 -0.01
113 D+0.6W (Case A, γ =180°) 0.56 -0.02 4.33 -0.11 -0.04 -0.01
113 0.6D+0.6W (Case B, γ = 0°) 0.03 -0.02 0.52 0.01 0.07 -0.01
113 0.6D+0.6W (Case A, γ =180°) 0.50 0.00 2.88 -0.09 -0.05 0.00
113D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.22 -0.02 1.11 -0.01 0.08 -0.01
D+0.75*0.6W+0.75S (Case A, γ = 180°) 0.58
113 0.00 2.88 -0.09 -0.01 0.00
115 D -0.39 -0.01 1.22 -0.02 -0.20 0.00
115 D+S -0.39 -0.01 1.22 -0.02 -0.20 0.00
115 D+0.6W (Case A, γ = 0°) 0.42 0.01 -0.36 0.01 0.23 0.00
115 D+0.6W (Case B, γ =180°) -1.31 -0.02 2.38 -0.05 -0.69 0.00
115 0.6D+0.6W (Case A, γ = 0°) 0.58 0.01 -0.85 0.02 0.31 0.00
115 0.6D+0.6W (Case B, γ =180°) -1.15 -0.02 1.89 -0.04 -0.61 0.00
115D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.22 0.00 0.03 0.00 0.12 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) -1.08
115 -0.02 2.09 -0.04 -0.56 0.00
115 D+0.6W (Case B, γ = 0°) 0.36 0.03 -1.69 0.02 0.19 0.00
115 D+0.6W (Case A, γ =180°) -1.31 -0.02 2.38 -0.05 -0.69 0.00
115 0.6D+0.6W (Case B, γ = 0°) 0.52 0.03 -2.18 0.03 0.27 0.00
115 0.6D+0.6W (Case A, γ =180°) -1.42 -0.04 3.84 -0.06 -0.74 0.00
115D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.17 0.02 -0.97 0.01 0.09 0.00
D+0.75*0.6W+0.75S (Case A, γ = 180°) -1.28
115 -0.04 3.55 -0.06 -0.66 0.00
129 D 0.38 0.00 1.27 -0.03 0.06 0.00
129 D+S 0.38 0.00 1.27 -0.03 0.06 0.00

25
129 D+0.6W (Case A, γ = 0°) 0.20 0.00 -0.72 0.02 0.13 0.00
129 D+0.6W (Case B, γ =180°) 0.56 -0.02 4.18 -0.11 -0.03 -0.01
129 0.6D+0.6W (Case A, γ = 0°) 0.05 0.00 -1.23 0.04 0.11 0.00
129 0.6D+0.6W (Case B, γ =180°) 0.41 -0.02 3.67 -0.10 -0.06 -0.01
129D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.25 0.00 -0.22 0.01 0.12 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) 0.51
129 -0.01 3.45 -0.09 -0.01 -0.01
129 D+0.6W (Case B, γ = 0°) 0.19 -0.02 1.01 -0.01 0.09 -0.01
129 D+0.6W (Case A, γ =180°) 0.56 -0.02 4.18 -0.11 -0.03 -0.01
129 0.6D+0.6W (Case B, γ = 0°) 0.03 -0.02 0.51 0.01 0.07 -0.01
129 0.6D+0.6W (Case A, γ =180°) 0.50 0.01 2.78 -0.09 -0.05 0.00
129D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.23 -0.02 1.08 -0.01 0.09 -0.01
D+0.75*0.6W+0.75S (Case A, γ = 180°) 0.58
129 0.00 2.78 -0.09 0.00 0.00
131 D -0.37 -0.01 1.17 -0.02 -0.19 0.00
131 D+S -0.37 -0.01 1.17 -0.02 -0.19 0.00
131 D+0.6W (Case A, γ = 0°) 0.42 0.01 -0.35 0.01 0.23 0.00
131 D+0.6W (Case B, γ =180°) -1.27 -0.02 2.30 -0.05 -0.67 0.00
131 0.6D+0.6W (Case A, γ = 0°) 0.57 0.01 -0.82 0.02 0.31 0.00
131 0.6D+0.6W (Case B, γ =180°) -1.12 -0.01 1.83 -0.04 -0.59 0.00
131D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.22 0.00 0.03 0.00 0.13 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) -1.05
131 -0.02 2.02 -0.04 -0.55 0.00
131 D+0.6W (Case B, γ = 0°) 0.36 0.02 -1.63 0.02 0.19 0.00
131 D+0.6W (Case A, γ =180°) -1.27 -0.02 2.30 -0.05 -0.67 0.00
131 0.6D+0.6W (Case B, γ = 0°) 0.51 0.03 -2.10 0.03 0.27 0.00
131 0.6D+0.6W (Case A, γ =180°) -1.38 -0.04 3.70 -0.06 -0.72 0.00
131D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.18 0.02 -0.93 0.01 0.10 0.00
D+0.75*0.6W+0.75S (Case A, γ = 180°) -1.24
131 -0.03 3.42 -0.06 -0.64 0.00
145 D 0.37 0.00 1.30 -0.03 0.06 0.00
145 D+S 0.37 0.00 1.30 -0.03 0.06 0.00
145 D+0.6W (Case A, γ = 0°) 0.19 0.00 -0.76 0.02 0.13 0.00
145 D+0.6W (Case B, γ =180°) 0.56 -0.02 4.31 -0.11 -0.04 -0.01
145 0.6D+0.6W (Case A, γ = 0°) 0.04 0.01 -1.28 0.04 0.11 0.00
145 0.6D+0.6W (Case B, γ =180°) 0.41 -0.02 3.79 -0.10 -0.06 -0.01
145D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.24 0.00 -0.24 0.01 0.11 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) 0.51
145 -0.02 3.55 -0.09 -0.01 -0.01
145 D+0.6W (Case B, γ = 0°) 0.17 -0.02 1.04 -0.01 0.09 -0.01
145 D+0.6W (Case A, γ =180°) 0.56 -0.02 4.31 -0.11 -0.04 -0.01
145 0.6D+0.6W (Case B, γ = 0°) 0.02 -0.02 0.52 0.01 0.06 -0.01
145 0.6D+0.6W (Case A, γ =180°) 0.50 0.00 2.86 -0.09 -0.05 0.00
145D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.22 -0.02 1.10 -0.01 0.08 -0.01
D+0.75*0.6W+0.75S (Case A, γ = 180°) 0.58
145 0.00 2.86 -0.09 0.00 0.00
147 D -0.39 -0.01 1.21 -0.02 -0.20 0.00
147 D+S -0.39 -0.01 1.21 -0.02 -0.20 0.00
147 D+0.6W (Case A, γ = 0°) 0.42 0.01 -0.36 0.01 0.23 0.00

26
147 D+0.6W (Case B, γ =180°) -1.30 -0.02 2.37 -0.05 -0.68 0.00
147 0.6D+0.6W (Case A, γ = 0°) 0.58 0.01 -0.84 0.02 0.31 0.00
147 0.6D+0.6W (Case B, γ =180°) -1.14 -0.02 1.88 -0.04 -0.60 0.00
147D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.22 0.00 0.03 0.00 0.12 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) -1.07
147 -0.02 2.08 -0.04 -0.56 0.00
147 D+0.6W (Case B, γ = 0°) 0.36 0.02 -1.68 0.02 0.19 0.00
147 D+0.6W (Case A, γ =180°) -1.30 -0.02 2.37 -0.05 -0.68 0.00
147 0.6D+0.6W (Case B, γ = 0°) 0.51 0.03 -2.17 0.03 0.27 0.00
147 0.6D+0.6W (Case A, γ =180°) -1.41 -0.04 3.81 -0.06 -0.73 0.00
147D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.17 0.02 -0.96 0.01 0.09 0.00
D+0.75*0.6W+0.75S (Case A, γ = 180°) -1.27
147 -0.04 3.53 -0.06 -0.66 0.00
161 D 0.25 0.02 0.85 -0.04 0.04 0.00
161 D+S 0.25 0.02 0.85 -0.04 0.04 0.00
161 D+0.6W (Case A, γ = 0°) 0.15 -0.01 -0.41 0.02 0.09 0.00
161 D+0.6W (Case B, γ =180°) 0.36 0.05 2.68 -0.13 -0.02 -0.01
161 0.6D+0.6W (Case A, γ = 0°) 0.05 -0.01 -0.75 0.04 0.07 0.00
161 0.6D+0.6W (Case B, γ =180°) 0.26 0.04 2.34 -0.11 -0.04 -0.01
161D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.18 0.00 -0.10 0.01 0.08 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) 0.33
161 0.04 2.22 -0.11 0.00 -0.01
161 D+0.6W (Case B, γ = 0°) 0.15 0.00 0.69 -0.01 0.07 -0.01
161 D+0.6W (Case A, γ =180°) 0.36 0.05 2.68 -0.13 -0.02 -0.01
161 0.6D+0.6W (Case B, γ = 0°) 0.05 -0.01 0.36 0.00 0.05 -0.01
161 0.6D+0.6W (Case A, γ =180°) 0.30 0.05 1.77 -0.10 -0.03 0.00
161D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.17 0.00 0.73 -0.02 0.06 -0.01
D+0.75*0.6W+0.75S (Case A, γ = 180°) 0.37
161 0.05 1.79 -0.10 0.00 0.00
163 D -0.24 0.00 0.79 -0.02 -0.12 0.00
163 D+S -0.24 0.00 0.79 -0.02 -0.12 0.00
163 D+0.6W (Case A, γ = 0°) 0.26 0.00 -0.18 0.01 0.15 0.00
163 D+0.6W (Case B, γ =180°) -0.81 0.01 1.50 -0.06 -0.43 -0.01
163 0.6D+0.6W (Case A, γ = 0°) 0.36 0.00 -0.50 0.02 0.19 0.00
163 0.6D+0.6W (Case B, γ =180°) -0.72 0.01 1.19 -0.05 -0.38 -0.01
163D+0.75*0.6W+0.75S (Case A, γ = 0°) 0.14 0.00 0.06 0.00 0.08 0.00
D+0.75*0.6W+0.75S (Case B, γ = 180°) -0.67
163 0.01 1.32 -0.05 -0.35 -0.01
163 D+0.6W (Case B, γ = 0°) 0.22 0.00 -0.99 0.03 0.12 0.00
163 D+0.6W (Case A, γ =180°) -0.81 0.01 1.50 -0.06 -0.43 -0.01
163 0.6D+0.6W (Case B, γ = 0°) 0.32 0.00 -1.31 0.04 0.17 0.00
163 0.6D+0.6W (Case A, γ =180°) -0.88 0.00 2.37 -0.08 -0.46 -0.01
163D+0.75*0.6W+0.75S (Case B, γ = 0°) 0.11 0.00 -0.55 0.02 0.06 0.00
D+0.75*0.6W+0.75S (Case A, γ = 180°) -0.80
163 0.00 2.21 -0.08 -0.41 -0.01

27