peo
intelligent charging system (OCPP1.6)
No matter what you drive or where you're going, EVCOME ev charger is
the surest way to power your journey.
www.evcomecharger.comEVCOME series | OCPP1.6
EVCOME EV Charger with a highly versatile range
Technical information
4G/ WIFVEtherne/RFID
‘Support OCPP1.6J, Http basic, Wi Sun
Support Ethernet cluster load balancing
‘Support M-Bus (flexible integration with solar system can
be realized through configuration)
PEN fault protection
Theft protection
can only be opened using a special tool.
*32A is available but may be restricted by
the condition of the vehicle's battery and
temperature increases at the charging
station
Connection mode
cB
Networking mode
WIFI, 4G, Ethernet
Interface standard
Typet, Type2, GB/T
Max. current and charging output
22 KW at 32A// 3-phase (applicable to TN
networks only)
12,7 kW at 32 / 3-phase (IT network)
74 kW at 324/ 1-phase (IT/TN network)
5Wat standby
‘Temperature range
30°C to +50°C
Standards and approvals
CE compliance in accordance with the Radio
Equipment Directive 2014/53/EU and ROHS
Directive 2011/65/EU, and compliance with
IEC 61851-1 (TUV SUD) and IEC 61851-22
Degree of protection
IPS4, indoor and outdoor use
1K10 impact protection
UL94 5VB flammability rating
UV resistant
Dimensions and weight
240 * 350 * 95mm, weight is about 7.5KGOCPP1.6 Operating Instructions for Docking Platform
1.Display interface
“The user selects the
Internet time, 0 time
zone by default, which
needs to be configured
‘maximum charging
‘current, and the ist
value can be configured
date
by the operator by the operator
a
= Voltage 388.20V
bsnl Current OA OR eave
artes fescoseaeeaator Naaoalll
= Preparing ‘operator Serial number
Don
= Unavatate t t
configurable by the operator (Displayed when the network is
deseo wate
block is displayed when the
network is connected)2.LCD charging state indication description - charging state description
28 Sep 2022 09:11:11
Mode 32a
Voltage 368.20V
Current oA
Power okw
Time 00:00:00
Energy okwh
Status Faulted
Power Meter Failure. AC_EVSE_Vi0.01
™ Available In standby mode, the gun can be inserted for charging
™ Preparing In preparation, the gun has been plugged in and is waiting to start charging
™ Charging During charging, the contactor is closed
™ Finished After charging, the contactor is disconnected
™ SuspendedEVSE The car cannot be charged. The gun has been inserted, and the charging pile is
normal, but does not output power (protocol limitation)
™ SuspendEV The car cannot be charged. The gun has been inserted, the output of the charging
pile is normal, and the car does not accept charging
™ Faulted fault
@ Unavailable Disable3.LCD charging state i
indication description - fault code description
28 Sep 2022 09:11:11
Mode 328,
Voltage 388.20V
Current 0A
Power ‘oKw
Time 00:00:00
Energy ‘OkWh
Status Faulted
™ Connector lock failure
™ EV Communication Error
™ Ground failure
High temperature
Internal error
™ Local list conflict
operator
™ Noerror
Other Error
™ Over current failure
™ Over voltage
™ Power meter failure
™ Power switch failure
™ Reader failure
Reset failure
™ Under voltage
™ Weak signal
AC_EVSE_VI001
Locking fault of gun and socket
Communication failure between charging pile and electric vehicle
Earth fault, leakage protection action
The temperature of the charging head is too high
Internal software or hardware failure
The charging pile configuration conflicts, and communication with the
No fault
Other faults
Over current fault, protector acts
The voltage is too high, exceeding the allowable value
Unable to read meter value
Unable to control the power switch
Card swiping failure
Cannot reset
The voltage is too low, exceeding the allowable value
Weak wireless signal4.Description of LED status indication
LCD
Mode
Voltage
Current
Power
Time
Eng OkWh
28 Sep 2022 09:11:11
2A
388,20V
0A
okw
00:00:00
Power Meter Failure. AC_EVSE_V10.01
status
Preparing Yellow ON
Available Blue ON Connected/ Blue Blink Not connected
Charging Green Breath
Finished Green ON
Faulted Red fast blink
Unavailable Red ON
Reserved White ON5.Method of configuring charging pile with computer (direct connection
of network cable)
pS eRe > Binfosemes > Bin
Method 1: Direct connection through network cable
Step 1: Connect the computer and the charging pile through the network cable
Step 2: Modify the IP address of the computer to 192.168.1.XX (such as 192.168.1.99). XX can be any
number between 0 and 255. Do not conflict with the address of the charging point. The default address
of the Charge Point is 192.168.1.253
“ 7 192.168.1.253 a
Please Login
‘Step 3: Enter the static IP address 192.168.1.253 of the Charge Point, enter the user name and
Password, and enter the Web management interface of the Charge Point6.Charge Point Web Management Interface
vee
vwwwoctet
ve
Network tr
Server Network
NetworkConfigurediface Server Network
Newaortguetce .
Es = 4
ETH_DHCP. dynamic address
WEI WIFI —"r :
CELUAR 4a Wifi password
WISUN Wisun
ETHSTATIC Static address7.Computer configuration of charging pile method (router) single pile
If only one stake is connected to the router, directly enter “ocpp. com” to access it.
Method 2: Configure through the router
Step 1: Connect the charging pile to the router through the network cable, and connect the
computer to the same router through wired or wireless;
Step 2: Open the computer browser and enter in the address bar http://ocpp.local.
Enter user name: root, password root@123456 , enter the web login page of the Charge Point.
The Web configuration method is as described previously.
Please Login8.Method of configuring charging piles with computers (router) Multiple
piles
oe” 2 see
“Charge Point Serial Number". local
Please Login
If there are multiple stakes connected to the router, you need to enter a “stake
number" for access.
Method 2: Configure through the router
Step 4: Connect the charging pile to the router through the network cable, and connect the
computer to the same router through wired or wireless;
Step 2: Scan the QR code of the charging pile with your mobile phone to obtain the serial number
information of the charging pile (a string of numbers such as 001D00363231 51030323833)
Step 3: Open the browser of the computer, enter "serial number. local" in the address bar (such
as 001D0036323151030323833. local), and enter the user name: root, password root@123456 ,
enter the web login page of the Charge Point.
The Web configuration method is as described previously.9.Description of charging pile web configuration
Configuration Conguaion
Sete Sse
Ais:]
Value Property Boolean Property
mnt (Ce. CS
a ‘Change Username ‘Change Password Setting Property
Change the charging Change the charging ‘Advanced
Pad pile's pile's customization
Web login user name Password for web
login
1. Select the option to be set, input the setting value directly, click the setting, and the reset will take
effect.
2. Select the option to be set and click Set to view the existing settings.10.Description of charging pile web configuration
MANAGEMENT
a)
oa
Cg
er
eed
Logger
net
Or
ee
Ped
Cont
ration Configuration
Value Property
Supper
CompotePiannedinerva \
onrectorDe
Name Defaut Description
CCemswetsockettn —_vlocpp alot: 18080steveNNebsockevCentalSystemSerice/ OCPP platform aderess
CchargePontis ‘System generation Cchaige pile 1D, generated by the system and modiiable
‘Serial number of charging pont, generated by the system and
seratNumber ‘system generation
mediate
‘Select the time zene, The defaut ime zone is 0. The system
LocaionTimezone 0
‘reads the Internet time, wbich canbe configured by et
‘The content displayed by OR code scanning Is the Charge
(cadeContext of Charge Point
Port ID by default. Self configuratie
suppertidcarsitag
Oftine card Configure oftine card nd start sping
HimiGuideCortext
‘Welcome message, “welcome to charge EV" by default self
contgurable
‘Welcome to charge EV.11.Method of offline card swiping start
€ SG @ bh FEF | cepplecalindexhtm
Configuration Configuration
MANAGEMENT
a=)
Value Property
Information NumberOfConnectors Ad
citer)
NpSeveur
NipserverPort
LecationTimeZone
Follower ‘GreodeContoxt
CConnectorid Greodesutix
Connectoric2arcodeSutix
Dr HimiGuidecontext
‘SimCardAPN |
‘SimCardUserame
Ceercey ‘SimCardPassword
‘CompositePlannedinterval
ConnectDetaultCurrentLimit
ConnecterDefaultMinCurrent
RemoteCiosedReconnectingWalt
CChargePointighTempTiveshold =
Prec)
Cer ee
Deni
Configuration Configuration
Value Property
‘SupperRfidCardidTag v
Card number is a combination of 8 digits or letters, and the letters should Ye capitalized.
Note: Use the card reader to read the card number, not the serial number written on
the card.12.How to change the logo on the boot interface
Step 1: Use a data cable. One end is a micro usb
interface, and the other end is a usb interface. Plug one
end of the data cable into the micro usb interface
(NO.17), and connect the other end to the PC. Ensure
that the motherboard is in normal power supply state.
‘Step 2: Open the computer file browser, the
system will prompt that there is a new USB.
flash disk (E:), and enter the HMI folder.
Step 3: Copy the logo image to this folder and
rename it as "logo. png”. The image resolution is
800 * 400 in PNG format
a
ote
axe
ne
One
oes
oe *
Rex
ons
Oos
800*480jpg
‘Step 4: When the equipment is powered off and then powered on, the system
automatically loads a new boot logo, and the change is completed.13.Web login account and password of the charging pile (private
password)
Each pile has a unique WEB login password (secondary password). The login name is root. The
default password is 7~16 digits of the pile serial number. Examples are as follows:
Serial Number: 003F 0018 3430 510B 3037 3736 (24 digits in total)
The serial number is generated by the system and can be obtained by scanning the screen QR code.
After logging in, the user can modify it on the web page. It is recommended that the manufacturer
paste the serial number on the outer surface of the product.
Default password: 1834305108 (10 digits in total)
J *
http://OCPP.local
Please Login
\ root
183430510B