Download as pdf
Download as pdf
You are on page 1of 15
peo intelligent charging system (OCPP1.6) No matter what you drive or where you're going, EVCOME ev charger is the surest way to power your journey. www.evcomecharger.com EVCOME series | OCPP1.6 EVCOME EV Charger with a highly versatile range Technical information 4G/ WIFVEtherne/RFID ‘Support OCPP1.6J, Http basic, Wi Sun Support Ethernet cluster load balancing ‘Support M-Bus (flexible integration with solar system can be realized through configuration) PEN fault protection Theft protection can only be opened using a special tool. *32A is available but may be restricted by the condition of the vehicle's battery and temperature increases at the charging station Connection mode cB Networking mode WIFI, 4G, Ethernet Interface standard Typet, Type2, GB/T Max. current and charging output 22 KW at 32A// 3-phase (applicable to TN networks only) 12,7 kW at 32 / 3-phase (IT network) 74 kW at 324/ 1-phase (IT/TN network) 5Wat standby ‘Temperature range 30°C to +50°C Standards and approvals CE compliance in accordance with the Radio Equipment Directive 2014/53/EU and ROHS Directive 2011/65/EU, and compliance with IEC 61851-1 (TUV SUD) and IEC 61851-22 Degree of protection IPS4, indoor and outdoor use 1K10 impact protection UL94 5VB flammability rating UV resistant Dimensions and weight 240 * 350 * 95mm, weight is about 7.5KG OCPP1.6 Operating Instructions for Docking Platform 1.Display interface “The user selects the Internet time, 0 time zone by default, which needs to be configured ‘maximum charging ‘current, and the ist value can be configured date by the operator by the operator a = Voltage 388.20V bsnl Current OA OR eave artes fescoseaeeaator Naaoalll = Preparing ‘operator Serial number Don = Unavatate t t configurable by the operator (Displayed when the network is deseo wate block is displayed when the network is connected) 2.LCD charging state indication description - charging state description 28 Sep 2022 09:11:11 Mode 32a Voltage 368.20V Current oA Power okw Time 00:00:00 Energy okwh Status Faulted Power Meter Failure. AC_EVSE_Vi0.01 ™ Available In standby mode, the gun can be inserted for charging ™ Preparing In preparation, the gun has been plugged in and is waiting to start charging ™ Charging During charging, the contactor is closed ™ Finished After charging, the contactor is disconnected ™ SuspendedEVSE The car cannot be charged. The gun has been inserted, and the charging pile is normal, but does not output power (protocol limitation) ™ SuspendEV The car cannot be charged. The gun has been inserted, the output of the charging pile is normal, and the car does not accept charging ™ Faulted fault @ Unavailable Disable 3.LCD charging state i indication description - fault code description 28 Sep 2022 09:11:11 Mode 328, Voltage 388.20V Current 0A Power ‘oKw Time 00:00:00 Energy ‘OkWh Status Faulted ™ Connector lock failure ™ EV Communication Error ™ Ground failure High temperature Internal error ™ Local list conflict operator ™ Noerror Other Error ™ Over current failure ™ Over voltage ™ Power meter failure ™ Power switch failure ™ Reader failure Reset failure ™ Under voltage ™ Weak signal AC_EVSE_VI001 Locking fault of gun and socket Communication failure between charging pile and electric vehicle Earth fault, leakage protection action The temperature of the charging head is too high Internal software or hardware failure The charging pile configuration conflicts, and communication with the No fault Other faults Over current fault, protector acts The voltage is too high, exceeding the allowable value Unable to read meter value Unable to control the power switch Card swiping failure Cannot reset The voltage is too low, exceeding the allowable value Weak wireless signal 4.Description of LED status indication LCD Mode Voltage Current Power Time Eng OkWh 28 Sep 2022 09:11:11 2A 388,20V 0A okw 00:00:00 Power Meter Failure. AC_EVSE_V10.01 status Preparing Yellow ON Available Blue ON Connected/ Blue Blink Not connected Charging Green Breath Finished Green ON Faulted Red fast blink Unavailable Red ON Reserved White ON 5.Method of configuring charging pile with computer (direct connection of network cable) pS eRe > Binfosemes > Bin Method 1: Direct connection through network cable Step 1: Connect the computer and the charging pile through the network cable Step 2: Modify the IP address of the computer to 192.168.1.XX (such as 192.168.1.99). XX can be any number between 0 and 255. Do not conflict with the address of the charging point. The default address of the Charge Point is 192.168.1.253 “ 7 192.168.1.253 a Please Login ‘Step 3: Enter the static IP address 192.168.1.253 of the Charge Point, enter the user name and Password, and enter the Web management interface of the Charge Point 6.Charge Point Web Management Interface vee vwwwoctet ve Network tr Server Network NetworkConfigurediface Server Network Newaortguetce . Es = 4 ETH_DHCP. dynamic address WEI WIFI —"r : CELUAR 4a Wifi password WISUN Wisun ETHSTATIC Static address 7.Computer configuration of charging pile method (router) single pile If only one stake is connected to the router, directly enter “ocpp. com” to access it. Method 2: Configure through the router Step 1: Connect the charging pile to the router through the network cable, and connect the computer to the same router through wired or wireless; Step 2: Open the computer browser and enter in the address bar http://ocpp.local. Enter user name: root, password root@123456 , enter the web login page of the Charge Point. The Web configuration method is as described previously. Please Login 8.Method of configuring charging piles with computers (router) Multiple piles oe” 2 see “Charge Point Serial Number". local Please Login If there are multiple stakes connected to the router, you need to enter a “stake number" for access. Method 2: Configure through the router Step 4: Connect the charging pile to the router through the network cable, and connect the computer to the same router through wired or wireless; Step 2: Scan the QR code of the charging pile with your mobile phone to obtain the serial number information of the charging pile (a string of numbers such as 001D00363231 51030323833) Step 3: Open the browser of the computer, enter "serial number. local" in the address bar (such as 001D0036323151030323833. local), and enter the user name: root, password root@123456 , enter the web login page of the Charge Point. The Web configuration method is as described previously. 9.Description of charging pile web configuration Configuration Conguaion Sete Sse Ais:] Value Property Boolean Property mnt (Ce. CS a ‘Change Username ‘Change Password Setting Property Change the charging Change the charging ‘Advanced Pad pile's pile's customization Web login user name Password for web login 1. Select the option to be set, input the setting value directly, click the setting, and the reset will take effect. 2. Select the option to be set and click Set to view the existing settings. 10.Description of charging pile web configuration MANAGEMENT a) oa Cg er eed Logger net Or ee Ped Cont ration Configuration Value Property Supper CompotePiannedinerva \ onrectorDe Name Defaut Description CCemswetsockettn —_vlocpp alot: 18080steveNNebsockevCentalSystemSerice/ OCPP platform aderess CchargePontis ‘System generation Cchaige pile 1D, generated by the system and modiiable ‘Serial number of charging pont, generated by the system and seratNumber ‘system generation mediate ‘Select the time zene, The defaut ime zone is 0. The system LocaionTimezone 0 ‘reads the Internet time, wbich canbe configured by et ‘The content displayed by OR code scanning Is the Charge (cadeContext of Charge Point Port ID by default. Self configuratie suppertidcarsitag Oftine card Configure oftine card nd start sping HimiGuideCortext ‘Welcome message, “welcome to charge EV" by default self contgurable ‘Welcome to charge EV. 11.Method of offline card swiping start € SG @ bh FEF | cepplecalindexhtm Configuration Configuration MANAGEMENT a=) Value Property Information NumberOfConnectors Ad citer) NpSeveur NipserverPort LecationTimeZone Follower ‘GreodeContoxt CConnectorid Greodesutix Connectoric2arcodeSutix Dr HimiGuidecontext ‘SimCardAPN | ‘SimCardUserame Ceercey ‘SimCardPassword ‘CompositePlannedinterval ConnectDetaultCurrentLimit ConnecterDefaultMinCurrent RemoteCiosedReconnectingWalt CChargePointighTempTiveshold = Prec) Cer ee Deni Configuration Configuration Value Property ‘SupperRfidCardidTag v Card number is a combination of 8 digits or letters, and the letters should Ye capitalized. Note: Use the card reader to read the card number, not the serial number written on the card. 12.How to change the logo on the boot interface Step 1: Use a data cable. One end is a micro usb interface, and the other end is a usb interface. Plug one end of the data cable into the micro usb interface (NO.17), and connect the other end to the PC. Ensure that the motherboard is in normal power supply state. ‘Step 2: Open the computer file browser, the system will prompt that there is a new USB. flash disk (E:), and enter the HMI folder. Step 3: Copy the logo image to this folder and rename it as "logo. png”. The image resolution is 800 * 400 in PNG format a ote axe ne One oes oe * Rex ons Oos 800*480jpg ‘Step 4: When the equipment is powered off and then powered on, the system automatically loads a new boot logo, and the change is completed. 13.Web login account and password of the charging pile (private password) Each pile has a unique WEB login password (secondary password). The login name is root. The default password is 7~16 digits of the pile serial number. Examples are as follows: Serial Number: 003F 0018 3430 510B 3037 3736 (24 digits in total) The serial number is generated by the system and can be obtained by scanning the screen QR code. After logging in, the user can modify it on the web page. It is recommended that the manufacturer paste the serial number on the outer surface of the product. Default password: 1834305108 (10 digits in total) J * http://OCPP.local Please Login \ root 183430510B

You might also like