PROJECT: ALANOD 2 MINI HYDRO POWER PLANT

LOCATION: KABAYAN, BENGUET


DESIGN OF BIFURCATION
DATA:
PENSTOCK LENGTH = 330.00 m
DESIGN DISCHARGE = 3.48 m3/sec
GROSS HEAD= 170 m
NET HEAD = 149.6 m
1 UNIT CAPACITY= 2,250 KW

PROJECT:
Q(DISCHARGE)= 1.74 m 3/sec
USING MANNING'S FORMULA TO COMPUTE FOR THE VELOCITY
A(AREA)= 0.478 m2
P(PERIMETER)= 2.450 m
R(HYDRAULIC RADIUS)= 0.195 m
V(VELOCITY)= 3.644 m/sec
D (DIAMETER OF PIPE)= 0.780 m INITIAL DIAMETER
VELOCITY 3.644 m/sec
PIPE DIAMETER
EFFECTIVE LENGTH= 46 meters0.780 m
OPTION 1-USING THE FORMULA FOR OPTIMUM DIAMETER (HYDRAULIC BOOK)
FORMULA 1 DIAMETER = 0.71P^0.43/H n^0.65
D= 0.76 m
DISCHARGE 1.74 m3/sec
PIPE DIAMETER (OPTIMUM) 0.76 m
OPTION 2-USING THE FORMULA FOR OPTIMUM DIAMETER (HYDRAULIC BOOK)
FORMULA 2 DIAMETER = 0.49P^0.43/H n^0.57
D= 0.78 m
3
DISCHARGE 1.74 m /sec
PIPE DIAMETER 0.78 m
DATA:
PENSTOCK LENGTH = 330 m
DESIGN DISCHARGE = 1.74 m3/sec
GROSS HEAD= 170 m
LENGTH OF PENSTOCK = 330.00 m
DESIGN DISCHARGE = 1.74 cu.m./sec
GROSS HEAD = 170.00 m
COMPUTED OPTIMUM PENSTOCK DIA. = 0.81 m
COMPUTED PIPE PRESSURE (STATIC) = 1,667.70 kPa
COMPUTED WATER HAMMER ALLOWANCE = 500.31 kPa
TOTAL PRESSURE IN PIPE = 2,168.01 kPa
COEFFICIENT OF "Y" = 0.40
THREADING "C" = 1.65

BIFURCATION SPECIFICATIONS

ASTM A36 Grade B = 413,700.00 kPa


THICKNESS OF PIPE (COMPUTED) = 4.70 mm
MINIMUM THICKNESS = 6.86 mm
STANDARD MINIMUM THICKNESS = 8.00 mm
USE (ACTUAL THICKNESS) = 8.00 mm(nominal thickness)
DIAMETER OF BIFURCATION = 0.81 m

ANCHOR BLOCK DESIGN