Ductos de Barras Eae
Ductos de Barras Eae
Busbar Systems
TSE - ISO
EN - 9000
CERTIFICATE NO
450/97
800 A.....6000 A
R
Modular Enclosures
Http://www.eae.com.tr
E-mail: electric@eae.com.tr P-Line Parapet Cable Distribution Systems
E-Line KB R
Contents
Introduction 2-3
Genleþme Modülü
( 70 cm. )
ý
ktas
No
Distribution
kýþ
Çý
2.
tusu
Ku
kýþ
Çý
-Ýn ý
Plug ktas
No
kýþ
Çý
B
1.
Alüminyum Ýletken
Çýkýþ Yükseklikleri
A
Frekans Hz 50/60 Hz
Koruma Sýnýfý IP 42 (aksesuarla IP 54) ý
ktas
Anma Akýmý A 800 1000 1250 1600 2000 2500 3000 4000 No
BUSBAR
KB A 16 0 0 - T R 4
Standard Components 9
Elbows 10
Standard Components 14
Flexibles / Expansions 15
Feeder Boxes 22
Determination of 26
Special Length
Certificates 27-28
E-Line KB R
Introduction
Wire Systems
2
E-Line KB R
Technical Features
Figure 1
Figure 2
Heat Transfer Insulators
"In compact structure" there is no empty space filled with
air and heat is easily transferred to the environment by the
housing that works like a heat-shink (Figure 4).
Figure 3
60
80Nm
Torqu Spanner (60lbft)
Ventilated Busbar
13,3 Section: 700 mm²
No Need For Fire Barrier I: 1000A
cosj:0,8
3
E-Line KB R
Components List
Item Components Quantity
Project Sample
4
E-Line KB R
er
a rri
eB
Fir
h= ......
I14
a= ...... 9. Floor
Vertical Expantion
( 70 cm. )
h= ......
I13
8. Floor
lug a= ......
.P
2th
h= ......
x
Bo
off I12
( h ) Height of store measured from ceiling to ceiling ( cm. )
-
T ap
g-in a= ...... 7. Floor
Plu
lug
h= ......
.P
1th
B
I11
Special Length Plug-in Busbar
a= ...... 6. Floor
Tap-off Point
h= ......
I10
a= ...... 5. Floor
A
h= ......
I9
t I8
oin a= ...... 4. Floor
rJ
s ba
Bu
h= ......
I7
I6
a= ...... 3. Floor
h= ......
I5
(a a= ...... 2. Floor
)C
eil
ing
h= ......
thi
ck
ne I4
ss
(c
m. a= ...... 1. Floor
)
h= ......
Project Design I3
5
E-Line KB R
Technical Characteristics
Aluminium Conductor - KBA
Rated Current In A 800 1000 1250 *1600 1600 2000 2500 *3050 3100 4000 *4250
Busbar Code 08 10 12 13 16 20 25 27 30 40 41
Standards IEC 60439-2: 2000
Rated Frequency f Hz 50 / 60
Protection Degree IP 55
Short-circuit (1 sec) Icw kA rms 50 50 50 50 100 100 100 100 120 120 120
Short-circuit (peak) Ip kA 105 105 105 105 220 220 220 220 264 264 264
Short-circuit Value
of Neutral Conductor (1 sec) Icw kA 30 30 30 30 60 60 60 60 72 72 72
Short-circuit Value kA
of Neutral Conductor (peak) Ip 63 63 63 63 132 132 132 132 158,4 158,4 158,4
Short-circuit Value kA
of Protective Circuit (1 sec) Icw 30 30 30 30 60 60 60 60 72 72 72
Short-circuit Value kA
of Protective Circuit (peak) Ip 63 63 63 63 132 132 132 132 158,4 158,4 158,4
20
R 20°C R 20 mW/m 0,055 0,041 0,032 0,026 0,028 0,021 0,016 0,013 0,014 0,011 0,009
Direct Current Resistance R mW/m 0,061 0,047 0,039 0,030 0,034 0,024 0,015 0,014 0,014 0,012 0,010
Empedance Z mW/m 0,076 0,055 0,044 0,038 0,037 0,027 0,021 0,017 0,018 0,014 0,012
Losses at Rated Current I²R1 W/m 128,6 162,0 201,6 268,8 299,5 348 318,8 474,4 461,3 655,3 596,1
Resistance (at Rated Current, mW/m
at Steady State Op. Temp.) R 1 0,067 0,054 0,043 0,035 0,039 0,029 0,017 0,017 0,016 0,014 0,011
Reactance mW/m
(at Rated Current) X1 0,045 0,030 0,020 0,023 0,016 0,014 0,014 0,010 0,011 0,006 0,006
Impedance Z1 mW/m 0,085 0,065 0,048 0,043 0,042 0,032 0,024 0,022 0,022 0,016 0,014
(at Rated Current)
L1, L2, L3, N mm² 525 700 910 1120 1050 1400 1820 2240 2100 2730 3360
PE (for 5 conductors) mm² 525 700 910 1120 1050 1400 1820 2240 2100 2730 3360
PE (for 4 ½ conductors) mm² 262,5 350 455 560 525 700 910 1120 1050 1365 1680
Housing Cross Section
(Sheet Metal) mm² 918 968 1028 1088 1836 1936 2056 2176 2904 3084 3264
Conductor Size mmxmm 7x75 7x100 7x130 7x160 2(7x75) 2(7x100) 2(7x130) 2(7x160) 3(7x100) 3(7x130) 3(7x160)
F= Supply
DV = Voltage Drop (V) L1,L2 0.25
a = Load Distribution Constant L1 F L2 Load
6
E-Line KB R
Technical Characteristics
Copper Conductor - KBC
Rated Current In A 1000 1250 1600 *2000 2000 2500 3000 *4000 4000 5000 *6000
Busbar Code 10 12 16 19 20 25 30 39 40 50 60
Standards IEC 60439-2: 2000
Rated Frequency f Hz 50 / 60
Protection Degree IP 55
Short-circuit (1 sec) Icw kA rms 50 50 50 50 100 100 100 100 120 120 120
Short-circuit (peak) Ip kA 154 154 154 154 220 220 220 220 264 264 264
Short-circuit Value
of Neutral Conductor (1 sec) Icw kA 30 30 30 30 60 60 60 60 72 72 72
Short-circuit Value kA
of Neutral Conductor (peak) Ip 63 63 63 63 132 132 132 132 158,4 158,4 158,4
Short-circuit Value kA
of Protective Circuit (1 sec) Icw 30 30 30 30 60 60 60 60 72 72 72
Short-circuit Value kA
of Protective Circuit (peak) Ip 63 63 63 63 132 132 132 132 158,4 158,4 158,4
20
R 20°C R 20 mW/m 0,034 0,026 0,020 0,016 0,017 0,013 0,010 0,008 0,009 0,007 0,005
Direct Current Resistance R mW/m 0,046 0,033 0,026 0,018 0,021 0,016 0,013 0,008 0,012 0,009 0,006
Empedance Z mW/m 0,054 0,041 0,033 0,023 0,025 0,021 0,017 0,011 0,014 0,010 0,007
Losses at Rated Current I²R1 W/m 159,0 173,4 222,7 300 276 337,5 378,0 528 624,0 750,0 756
Resistance (at Rated Current, R mW/m 0,053 0,037 0,029 0,025 0,023 0,018 0,014 0,011 0,013 0,010 0,007
at Steady State Op. Temp.) 1
Reactance X1 mW/m 0,031 0,025 0,020 0,015 0,015 0,014 0,010 0,007 0,008 0,005 0,004
(at Rated Current)
Impedance Z1 mW/m 0,059 0,046 0,036 0,029 0,028 0,023 0,018 0,013 0,016 0,012 0,008
(at Rated Current)
L1, L2, L3, N mm² 525 700 910 1120 1050 1400 1820 2240 2100 2730 3360
PE (for 5 conductors) mm² 525 700 910 1120 1050 1400 1820 2240 2100 2730 3360
PE (for 4 ½ conductors) mm² 262,5 350 455 560 525 700 910 1120 1050 1365 1680
Housing Cross Section
(Sheet Metal) mm² 918 968 1028 1088 1836 1936 2056 2176 2904 3084 3264
Conductor Size mmxmm 7x75 7x100 7x130 7x160 2x(7x75) 2(7x100) 2(7x130) 2(7x160) 3(7x100) 3(7x130) 3(7x160)
F= Supply
DV = Voltage Drop (V) L1,L2 0.25
a = Load Distribution Constant L1 F L2 Load
7
E-Line KB R
BUSBAR TYPE
Order Code System CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
UTILIZATION TYPE
UNPAINTED / PAINTED
COMPONENT
KB A 16 5 0 TR41
8
E-Line KB BUSBAR TYPE
R
CONDUCTOR TYPE
Standard Straight Length BUSBAR CODE
PROTECTION DEGREE
TYPE
UNPAINTED / PAINTED
COMPONENT
KB
Bolt-on
Bolt-on Bolt-on
L1
L2
L3
Bolt-on
N
3000
0
Electrical energy up to 800 A can be Sample Order:
supplied from the joints of bolt-on type 3000 A, Copper, Bolt-on,
by bolt-on tap-off boxes. IP 55, 4 Conductors
KBC 3050 - STD L1
As feeder or sub-feeder line, L2
L3
Where a load has to be supplied N
from the busbar.
Plug-in
Feeder
L1 N
L2 L3
L3 L2
N L1
3000
2 Feeder
N
Generator, composition supplies
L2
4000 40 5000 50 535 KBC 2052-147 L3
N
* 4250 41 *6000 60 625
Minimum Length = 35 cm
* New product group
9
E-Line KB BUSBAR TYPE
CONDUCTOR TYPE
Elbows BUSBAR CODE
PROTECTION DEGREE
TYPE
UNPAINTED / PAINTED
COMPONENT
KB
- U Upwards Elbow
400
325
Sample Order:
3000 A, Copper, Bolt-on, L1
L2
IP 55, 4 Conductors L3
N
KBC 3050-U 5
32
0
40
0
40
5
- D Downwards Elbow 32
L1
400
L2
Sample Order:
325
L3
3000 A, Copper, Bolt-on, N
IP 55, 4 Conductors
KBC 3050-D
- L Left Elbow
A
B
Sample Order:
2000 A, Aluminium, Bolt-on,
IP 55, 4 Conductors
KBA 2050-L L1
L2
L3
B
Al Cu - R Right Elbow
A B
Conductor Conductor
Rated Busbar Rated Busbar (mm) (mm)
Current Code Current Code Sample Order:
A
A
10
E-Line KB BUSBAR TYPE
CONDUCTOR TYPE
Elbows BUSBAR CODE
PROTECTION DEGREE
TYPE
UNPAINTED / PAINTED
COMPONENTS
KB
KBC 3050-LH60 - LH
x X
(cm)
B
A
L1
L2
L3
N
KBC 3050-RH60 - RH
x B
(cm)
A
L1
L2
L3
N
0
40
5
32
KBA 2050-UV45 - UV
Y
(cm)
L1
L2
L3
N
5
32
0
40
Al Cu
A B X
Conductor Conductor
Rated Busbar Rated Busbar (mm) (mm) (cm)
Current Code Current Code
0
800 08 1000 10 420 355 70 40
1000 10 1250 12 445 367 73 5
32
1250 12 1600 16 475 383 76 Downwards
* 1600 13 *2000 19 505 398 78 Vertical Offset
Y=min:15cm / max:64 cm
1600 16 2000 20 540 440 82 Sample Order:
2000 20 2500 25 590 470 87 Y=45 cm, 2000 A, Aluminium
2500 25 3000 30 650 513 93 L1
Bolt-on, IP 55, 4 Conductors L2
* 3050 27 *4000 39 710 500 99 L3
N
3100 30 4000 40 735 512 102
KBA 2050-DV45 - DV
4000 40 5000 50 825 560 111
* 4250 41 *6000 60 915 603 120 Y
(cm) 5
32
Y
11
E-Line KB BUSBAR TYPE
CONDUCTOR TYPE
Elbows BUSBAR CODE
PROTECTION DEGREE
TYPE
UNPAINTED / PAINTED
COMPONENT
KB
A
- K U L Upwards Left B
Combined Offset
Sample Order:
3000 A, Aluminium
Bolt-on, IP 55, 4 Conductors
KBA 3050-KUL
L1
300
L2
L3
N
5
32
0 0
KUL 4
- K U R Upwards Right A
Combined Offset B
Sample Order:
3000 A, Aluminium
Bolt-on, IP 55, 4 Conductors
KBA 3050-KUR
L1
L2
300
L3
N
5
32
0 0
KUR 4
0
- K D L Downwards Left 40
Combined Offset 32
5
Sample Order:
3000 A, Aluminium L1
L2
Bolt-on, IP 55, 4 Conductors L3
N
KBA 3050-KDL
300
KDL A
Al Con. Cu Con. A B
Rated Busbar Rated Busbar 0
(mm) (mm) 40
Current Code Current Code - K D R Downwards Right 5
800 08 1000 10 420 355 Combined Offset 32
1000 10 1250 12 445 367
Sample Order:
1250 12 1600 16 475 383 3000 A, Aluminium
* 1600 13 *2000 19 505 398 Bolt-on, IP 55, 4 Conductors L1
1600 16 2000 20 540 415 L2
300
L3
2000 20 2500 25 590 440 N
KBA 3050-KDR
2500 25 3000 30 650 470
* 3050 27 *4000 39 710 500
3100 30 4000 40 735 512
4000 40 5000 50 825 558 B
* 4250 41 *6000 60 915 603 KDR
* New product group A
12
E-Line KB BUSBAR TYPE
CONDUCTOR TYPE
Elbows BUSBAR CODE
PROTECTION DEGREE
TYPE
UNPAINTED / PAINTED
COMPONENT
KB
- K L U Left Upwards
Combined Offset
Sample Order:
3000 A, Aluminium
400
Bolt-on, IP 55, 4 Conductors
325
KBA 3050-KLU
30
0
A
L1
L2
L3 KLU
N
- K R U Right Upwards
Combined Offset
Sample Order:
A
3000 A, Aluminium
B
Bolt-on, IP 55, 4 Conductors
KBA 3050-KRU
325
400
30
0
L1
L2
L3
N
KRU
- K L D Left Downwards
Combined Offset
30
Sample Order:
0
3000 A, Aluminium
400
KBA 3050-KLD
B
L1
L2
L3
N
KLD
Al Cu
A B
Conductor Conductor
Rated Busbar Rated Busbar (mm) (mm)
Current Code Current Code - K R D Right Downwards
800 08 1000 10 420 355 Combined Offset
1000 10 1250 12 445 367
1250 12 1600 16 475 383 Sample Order:
A
L3
* New product group
N KRD
Please call us for non-standard components.
13
E-Line KB BUSBAR TYPE
CONDUCTOR TYPE
Standard Components BUSBAR CODE
PROTECTION DEGREE
TYPE
UNPAINTED / PAINTED
COMPONENT
KB
End Closer
- S 1 0
End Closer Sample Order:
Is used to close the end of busbar run. 2500 A, Copper, Bolt-on, L1
L2 0
IP 55, 4 Conductors L3 60
KBC 2550-S10 N
End Closer
- S 1 1 L1
L2
Sample Order: L3
N
2500 A, Copper, Bolt-on, 0
60
IP 55, 4 Conductors
KBC 2550-S11
- RD Reduction
800 A - 08
Reduction Sample Order: 1000 A - 10 00
10
2000A / 1600A, Aluminium, 1250 A - 12
Is used to change the busbar cross section. Bolt-on, IP 55, 4 Conductors 1600 A - 13
1600 A - 16
5
KBA 2050-RD16 2000 A - 20 33
2500 A - 25
3050 A - 27
5
3100 A - 30 L1 66
4000 A - 40 L2
L3
4250 A - 41 N
5000 A - 50
A
- T Y R C
B
Sample Order:
2500 A, Aluminium, Bolt-on,
IP 55, 4 Conductors
KBA 2550-TYR L1
L2
L3
N
A
C
B
- T Y L
Sample Order:
2500 A, Aluminium, Bolt-on,
Al Cu IP 55, 4 Conductors
A B C
Conductor Conductor KBA 2550-TYL L1
L2
Rated Busbar Rated Busbar (mm) (mm) (mm) L3
Current Code Current Code N
14
E-Line KB BUSBAR TYPE
CONDUCTOR TYPE
Flexibles & Expansions BUSBAR CODE
PROTECTION DEGREE
TYPE
UNPAINTED / PAINTED
COMPONENT
KB
- Y D T Horizontal Expansion
Sample Order:
2500 A, Aluminium,
Bolt-on, 4 Conductors
Horizontal Expansion KBA 2550-YDT
Used at every 40 m in horizontal L1
L2
long lines and for crossing building L3
expansions. N
00
15
- D D T Vertical Expansion
Sample Order:
2000 A, Copper, Bolt-on,
4 Conductors
Vertical Expansion
KBC 2050-DDT L1
For vertical application in many storey L2
L3
building. N
0
to be used at every floor between 70
fixed support points.
- F Flexibles
Sample Order: L
800 A, Aluminium (cm)
Flexible are used for
KBA 0800-F40
Transformer - busbar,
Panel - busbar connections.
* B
L
X
Z Y
B=.....mm
X=.....mm
Y=.....mm
Z=.....mm
ø=.....mm
15
E-Line KB BUSBAR TYPE
CONDUCTOR TYPE
R
BUSBAR CODE
Panel Connections PROTECTION DEGREE
TYPE
UNPAINTED / PAINTED
COMPONENT
KB
250
250
Panel Connection
200
200
Panel Feeder - P 1 0 N
L3 N
Busbar Feeder - P 1 1 P10 L 2 L1 L3
L 2 L1
L1 L2 P11
L3 L1 L2
N L3
Sample Order: N
2000 A, Copper, Bolt-on,
L for Busbar Feeder
L3 N 1L
40
0
40
0
L1 L L1
2
L2
NL 2 L
3L
3N KBC 2050-P11
L 3 5 5
N 2L
1
32 32
400
400
325
325
Panel Feeder - PU20
Busbar Feeder - PU21
200
200
Sample Order:
N N
2000 A, Copper, Bolt-on, L3 L3
L2 L2
for Panel Feeder L1 L1
Attention !... PU20 PU21
KBC 2050-PU20
The position of the panel board conductors
and the position of the busbar according 0 0
40 40
to panel board must be taken into account Downwards Panel Connection 5 5
before installation. 32 32
400
400
Side is defined as 0
325
325
Side is defined as 1
200
200
Sample Order:
2000 A, Copper, Bolt-on,
for Busbar Feeder L1 L1
L2 L2
KBC 2050-PD21 L3 L3
N N
Rated Current / Busbar Code PD20 PD21
Aluminium (Al) 800 / 08 1000 / 10 1250 / 12 *1600 / 13 1600 / 16 2000 / 20 2500 / 25 *3050 / 27
Copper (Cu) 1000 / 10 1250 / 12 1600 / 16 *2000 / 19 2000 / 20 2500 / 25 3000 / 30 *4000 / 39
1 2
200
200
ø13 ø13
E C
E C
B D B D B D
12 A 12 A
100 100 100 100 ø7 ø7
12
12
100 100 100 100 100
1 E-Line KB Busbar 2 2
2 Panel Connection Plate 3
3
3 Opening on the panel board
500
600
600
500
1 1
16
E-Line KB BUSBAR TYPE
CONDUCTOR TYPE
R
KB
A
A
Right Panel Connection B
B
A
Panel Feeder - P R30
A
B
Busbar Feeder - P R31
B
200
Sample Order:
200
L
L3 N 1L 2000 A, Copper, Bolt-on,
L1 L L1 NL 2 L
2
3N
L 3
L2 3L
2L
for Panel Feeder
N
1
N L3 L1 2
KBC 2050-PR30 L2
L
L3
L1 N
PR30 PR31
A A
B B
Attention !... Left Panel Connection
A
A
The position of the panel board conductors
B
B
and the position of the busbar according Panel Feeder - P L 30
to panel board must be taken into account Busbar Feeder - P L 31
200
before installation.
200
Sample Order:
2000 A, Copper, Bolt-on, L1 2
L
L3 N L3
A and B dimensions of PL30 and PL31 are same for Busbar Feeder N L2
L1
as left and right elbows, please refer to page 10 KBC 2050-PL31
for the dimensions. PL30 PL31
200
ø13 ø13
E C
E C
B D B D B D B 45 B D B 45 B D B 45 B D
12 A 12 A
ø7
12
12
ø7
2
100 100 100 100 100
3 3
600
600
500
500
1 1
G G
100 100 100 100 100 100 100 100 100 100 100 100
* Please call us for non-standard
components. F F
17
E-Line KB BUSBAR TYPE
CONDUCTOR TYPE
Transformer Connections BUSBAR CODE
PROTECTION DEGREE
TYPE
UNPAINTED / PAINTED
COMPONENT
KB
Transformer - T R11
Connection
Sample Order:
250
2500 A, Aluminium, Feeder,
4 Conductors
200
N KBA 2552-TR11
L3
TR11 N
L2 L3
L 2 L1
L1 L2
L3
N
L1
0
40
Upwards - T U21 5
32
Transformer Connection
Sample Order:
2500 A, Aluminium, Feeder,
400
325
4 Conductors
KBA 2552-TU21
200
TU21
N
L3
L2
L1
0
Downwards - T D21 40
5
Transformer Connection 32
For transformer and panel connection Sample Order:
applications EAE design and planning 2500 A, Aluminium, Feeder,
group will prepare your projects upon
400
4 Conductors
325
request.
KBA 2552-TD21
200
Transformer - T R31
Connection
0
80
Sample Order:
2500 A, Aluminium, Bolt-on,
200
4 Conductors
KBA 2550-TR31
For connection dimesions please refer L1
to tables on pages 16 and 17. L2
L3 50
TR31 N
65
51
16
165
18
E-Line KB BUSBAR TYPE
CONDUCTOR TYPE
Transformer Connections BUSBAR CODE
PROTECTION DEGREE
TYPE
UNPAINTED / PAINTED
COMPONENT
KB
Transformer - T R41
Connection
Sample Order:
00
20
N
2000 A, Copper, Bolt-on, L1
0
L 11
3
4 Conductors
KBC 2050-TR41 0
L2 L2 67
L1 L3 0
67
N
0
29
TR41
Right - T R51 A
Transformer Connection
B
Sample Order:
A
2500 A, Aluminium, Feeder,
B
4 Conductors
KBA 2552-TR51
200
L1 2
L
For transformer and panel connection TR51 L3
N
applications EAE design and planning
group may prepare your projects upon
request.
For Project;
N L3
L2
L1
TL51
19
E-Line KB BUSBAR TYPE
BOX TYPE
RATED CURRENT Bolt on- B
Tap-off Boxes PROTECTION 160 A-16
250 A-25
Plug in- P
DEGREE
with Fused Switches (SYK) CONDUCTOR IP-55-5
400 A-40
630 A-63
4-0
5-1
CABLE GLAND PLATES
KB
Cable Gland Plates
65
Sheet 2xSpecial RP4 63 KB B 1 650
B
KB B 2 550
KB B 4 050
PP* 4xPG21 RP5 18
KB B 6 350
C
PP 4xPG29 RP6 25
Sample Order:
te
Bolt-on / 630 A / IP-55 / Pl
a
A
5 Conductors nd )
L1 la des
PP 4xPG36 RP7 32 KBB 6351 L2 L e
G si
3
N a bl n 3
C ( o
PP 8xPG29 RP8 25
PP* Polypropylene
EAE SYK
Can operate under load
Are equipped with NH fuse holders
Have interlock mechanism
KB P 1650
KB P 2550
Plug-in
KB P 4050
Tap-off Boxes
65
SYK 160 A
B
a te
Tap-off A B C Standard Fuse Pl
nd s)
AA
20
E-Line KB BUSBAR TYPE
BOX TYPE
RATED CURRENT Bolt on- B
Tap-off Boxes PROTECTION 160 A-16
250 A-25
Plug in- P
DEGREE
for MCCB's CONDUCTOR IP-55-5
400 A-40
630 A-63
4-0
5-1
CABLE GLAND PLATES
KB
Cable Gland Plates
B
KB B 2 550
KB B 4 050
PP* 4xPG21 RP5 18
C
KB B 6 350
PP 4xPG29 RP6 25
Sample Order: te
a
Bolt-on / 630 A / IP-55 / Pl
A
nd )
5 Conductors la des
L1 G si
PP 4xPG36 RP7 32 KBB 6351
L2 L e
bl n 3
3
N C a ( o
PP 8xPG29 RP8 25
PP* Polypropylene
Special Cable Gland Plates
Cable Order Inner
Mat. Gland Type Code Diameter
(mm)
Sheet ---- RPK0 ----
laide
L1 G s
KBB 63 690 310 180 RP4 S6 L2 e
bl n 3
KBP 16 520 310 240 RPK3 S2 L3 Ca (o
N
KBP 25 570 310 240 RPK4 S3
KBP 40 670 310 240 RP4 S5
21
E-Line KB BUSBAR TYPE
CONDUCTOR TYPE
Feeder Boxes BUSBAR CODE
PROTECTION DEGREE
TYPE
UNPAINTED / PAINTED
COMPONENT
KB
Cable Gland Plates Feeder Box B10
Busbar Cable Type L1
Housing Type Gland Plate L2
- B 1 0 L3
Sample Order: N
PE
3000 A, Aluminium, Bolt-on
1 KBA 3050 - B10
Sample Order: - B 1 1
1000 A, Aluminium, Bolt-on
3 KBA 1050 - B11 L1
L2
L3
N
PE
200 D C
22
E-Line KB R
Application of
Feeder Boxes for the horizontal lines
L1
In horizontal applications neutral conductor L2
is considered to be lower conductor. L3
N
PE
Application of
PE
L1
L2
L3
N
23
E-Line KB ORDER CODE
LENGTH L (mm)
R
Fixing Elements
D10
TU0
Supports
T10
IDD 400
IDD 600
IDD 800 IDD
IDD 1000 L
IDD 1200
IDD 2000
BR4 500
BR4 600 40
STK
STK 200
STK 300 STK
IDD STK 400
UDD 400
IDD UDD 600
UDD 800 UDD
IDT UDD 1000 L
UDD 1200
IDY
STS 200
STS 300 STS
STS 400
5
15
UDY 400
UDY 600
UT UDY 800 UDY
A
UDY 1000 L
UDY 1200
UDY 2000
Al Cu
A
Conductor Conductor
Rated Busbar Rated Busbar (mm)
Current Code Current Code IDT Fixing Element
800 08 1000 10 135 Steel Dowel
1000 10 1250 12 160
1250 12 1600 16 190 T10 500 (M10)
* 1600 13 *2000 19 220 T10 1000 (M10)
1600 16 2000 20 255 T12 500 (M12) Extension
2000 20 2500 25 305 T12 1000 (M12) Unit
2500 25 3000 30 365 TUO-(M10)
* 3050 27 *4000 39 425 UT TU2 -(M12)
3100 30 4000 40 450 KBA1250 UT
L
24
E-Line KB ORDER CODE
LENGTH L (mm)
R
Fixing Elements
Supports
UDD 300
400
...
UDD 2000
Standard sizes of UDD are between
300 mm to 2000 mm.
UDYB
UDYB 300
400
...
1000
Standard sizes of UDYB are between
300 mm to 1000 mm.
UDD
STS
TMP 5
PDD
PDDB 300
400
...
1000
PDDB Standard sizes of PDDB are between
300 mm to 1000 mm.
25
E-Line KB R
After the installation of standard 3m busbar lengths, you will be in need of special
lengths which are smaller than 3m. The minimum length for these special
elements can be 35 cm. Please measure the lengths of these modules as shown
below.
"A" length should be indicated in cm. Measure the asistance from one end of the
side housing to the other.
26
EC CONFORMITY CERTIFICATE
This conformity certificate has been issued after running the below listed tests at laboratories.
Type Tests
1- Temperature-rise limits
2- Dielectric properties
3- Short-circuit strength
4- Effectiveness of the protective circuit
5- Clearances and creepage distances
6- Mechanical operation
7- Degree of protection
8- Electrical Characteristics
9- Structural Strength
10-Crushing resistance
11-Resistance of insulating materials to abnormal heat
12-Fire barrier
27
E-Line KB R
Certificates
28
Component List
Item Component Quantity
E-Line KB
Project Design Form
Company :
Project :
Project No :
Name :
Date :
Signature :
Prepared by
Yetkili Satýcý
Ýkitelli Organize Sanayi Bölgesi, Turgut Özal Cad., Haseyad No.:112 34670
Tel.: (0.212) 549 23 02 (Pbx) Faks: (0.212) 549 23 10 Ýstanbul / TÜRKÝYE
E-posta : eae@eae.com.tr / electric@eae.com.tr http://www.eae.com.tr