SUMMARY

TAP CHANGERS TYPE 096

096-Warning Tap changers type 096

096-A050 three-phase tap changer bridge connection 30/60 A 24/36 kV 3-7 pos.
096-A055 three-phase tap changer bridge connection 30/60 A 24/36 kV 3-7 pos.
096-A060 three-phase tap changer bridge connection 30/60 A 24/36 kV 3-7 pos.
drive in the middle
096-A065 three-phase tap changer star connection 30/60 A 24/36 kV 3-7 pos.
096-A070 three-phase tap changer series/parallel 30/60 A 24/36 kV 2 pos.
drive in the middle
096-A075 three-phase tap changer change voltage 30/60 A 24 kV 2 pos.
096-A080 three-phase tap changer 2 bridge +1 S/P 30/60 A 24 kV 3-5 pos.

096-A010 three-phase tap changer bridge connection 150 A 24/36 kV 3-7 pos.
096-A015 three-phase tap changer bridge connection 150 A 24/36 kV 3-7 pos.
096-A020 three-phase tap changer bridge connection 150 A 24/36 kV 3-7 pos.
drive in the middle
096-A022D DOUBLE three-phase bridge connection 150 A 24/36 kV 3-7 pos.
096-A025 three-phase tap changer series/parallel 150 A 24/36 kV 2 pos.
drive in the middle
096-A027 three-phase tap changer series/parallel 150 A 24/36 kV 2 pos.
096-A030 three-phase tap changer change voltage 150 A 24 kV 2 pos.
096-A035 three-phase tap changer 2 bridge +1 S/P 150 A 24 kV 3-5 pos.
096-A040 three-phase tap changer linear connection 150 A 24/36 kV 3-7 pos.

096-01 coupling
096-60-02 type drive handle
096-60-03 type drive handle
096-60-04 type drive handle
096-60-05 drive handle numbering disk
TAP CHANGERS TYPE 096

MAIN CHARATERISTIC
this is an off-circuit tap changers. It means all switching manoeuvre must be performed after
disconnecting transformer by the electrical net opening the sectionalizing switches, both HV and LV
side, so transformer becomes off-circuit.
In the catalogue are performed the standard appliances and devices.
On request is possible to satisfy special requirements as:
- Single-phase
- multi-stage tap changers
- mirror like assembling
- insulated intermediate clamp for different dimension of the shaft “L”
- special executions

Mechanical characteristics
On the tap-changers type 096 fixed contacts are mounted in one of two parallel insulating strips,
perpendicular to the drive shaft; moving contacts are installed on the other strip. The fixed strip is
attached to the mounting components in which the moving strip slides, driven by a pinion.

Changing over
A notch is provided to mark each position with precision. For any operation, the notch must first of
all be released by applying an axial pull on the control knob; after that once the knob is facing its
new one position, it drops automatically into the respective notch by the action of a spring. The
control knob is marked with the inscription engraved on request in the desired language:
“OPERATE WITHOUT VOLTAGE”
“LIFT – TURN – SWITCH ON”
to indicate the process of this operation. This operating knob can also be supplied without any
inscription.

Position: standard from 3 to 7 positions

Voltages
Voltage classes are allowed for:
voltage max permissible Earth withstand voltage
class voltage Industrial frequency 50 Hz Impulse 1/50
kV kV kV kV
20 24 50 125
30 36 70 170
According standard IEC 60214-1 2003-02 e IEC 60214-2 2004-10

Currents
10 A – 30 A – 60 A – 150 A.

Metallic parts
These parts mainly assembled in the bearing and drive control, are normally made of nickel-plated
mild steel and aluminum alloy; mild steel parts exposed to external environment on request can be
made of stainless steel, aluminum parts can be protected by chromate passivating process.

Fixed contacts
Made of copper with following internal diameters:
Ø=3,1mm for 30 A rating - Ø=5,1mm for 60 A rating - Ø=8,1mm for 150 A rating - M8 for 150 A
rating

The connection of the conductors is provided by crimping of flexible cables. It can also be carried out
by tin soldering, if so, care should be taken to avoid damages on the insulation parts. Made of
copper with screw M8 for 150 A rating. On request contacts can be silver-plated.

Moving contacts
They are made of brass. On request, contacts can be supplied silver plated.
Codes
To identify tap changer type by series and code, proceed like example below reported:
SERIES: 096 CODE: 80.09.265
096- 80. 09. 2 6 5
Family type bearing length L=91 voltage Current number of positions n°5
mm (13 = L 131 mm) 20 kV 60 A
L = has to be determined with order
Please also specify type of control knob

DIMENSION
All dimension reported in the following pages are in millimeters (mm)

MODIFICATIONS
In case we need to modify some particulars, in order to improve the quality of our products, CAPT
firma reserve an option to change without a previous warning. Substantial modification will be
surely communicated.

TRANSFORMER OIL
All our tap changers are suitable to work in oil immersed transformers according to standard IEC
60296. In case user need to use specific oil (silicon, synthetic or vegetal) it is necessary consulted
CAPT technical office who verify the functionality of tap in all the mechanicals, electrical and
chemical characteristics.

INSULATION MATERIAL
The insulating materials used are bakelite (paper laminates and phenoplastic resin) of “E” thermal
class

GASKET
Gasket supply in our tap changers and in our transmission drive handles are type HNBR and they
are suitable for oil transformer, indicate for temperature in oil between -25°C and +100°C and for
temperature on air between -25°C and +40°C, according to IEC 60214-1/2.
On request, we can supply tap changer with special rubber for low temperature till -60°C and for
high temperature till +200°. These gaskets are suitable for oil transformer and they can be in
VITON, in Silicon rubber. They can be used in arctic or tropical conditions.

DRYING TREATMENT
Different drying treatment can be process by customer: oven, in a vacuum autoclave, vapor-phase
or other. In this process is normally included tap changer too. The maximum temperature suggested
by CAPT for our tap changers is 100°C-120°C for 24-36 hours.

DRYING TREATMENT IN CASE OF BEVEL GEAR AND DRIVE HANDLE


It is better to leave out from drying treatment the drive handle and bevel gear. In case it is
impossible to leave them out, we suggest to strictly respect the temperature recommended.
When you need drive handle with micro switch for electrical lock or electrical position transmitter it
is recommended to do the treatment without the drive.

WHEN CONTACT CAPT


In the following cases please contact CAPT
• for temperature condition higher/lower then suggest
• for hard temperature conditions, with possibility of snow or sand storming, or in potential
seismic area

TEST (Test reports are furnished on request)


On tap changers, following our internal quality procedures, are carried out the routine tests and on
some prototypes the type tests at the CESI in Milan, at University of Padua and at the Institute
Galileo Ferraris in Turin. Our off-circuit tap changers are tested according to IEC 60214-1 2003-02 e
IEC 60214-2 2004-10 as follows:
Section 3 – Clause 7.2 – Type test
- 7.2.2 - Temperature rise of contacts.
- 7.2.3 - Short-circuit test.
- 7.2.5 - Dielectric tests.
Section 3 – Clause 7.3 – Type test
- 7.3.1 - Mechanical test. Test
THREE PHASE TAP CHANGERS TYPE "50"

- Off-circuit operation - 24 kV / 36 kV
- For oil immersed transformer - 30 A / 60 A
- Bridge connection - From 3 to 7 positions
- Regulation 2,5% per position Dimension in mm

060-96.6000
or 060-96.6020
or 060-96.6400
30
On voltage 23

COVER
==
20

Ø 27 H12

54
10

I
20

35

21

24,5
Bu5 R 24,5 60,5 28
A 113

93
68,5
56

Z
U
17 C F C G C E D
OK 8
10
20

OJ
( )

PRODUCT CODE
L= 91 I= 80,5 L=131 I= 120,5 mm
KV N° POS.
30 A 60 A 30 A 60 A
J= 3,1 / K= 5 J= 5,1 / K= 7 J= 3,1 / K= 5 J= 5,1 / K= 7 A B C D E F G Z
3 50.09.233 50.09.263 50.13.233 50.13.263 503 313 63 72 84 76 65 21
4 50.09.234 50.09.264 50.13.234 50.13.264 587 355 84 93 84 76 65 21
24 5 50.09.235 50.09.265 50.13.235 50.13.265 671 397 105 114 84 76 65 21
6 50.09.236 50.09.266 50.13.236 50.13.266 755 439 126 135 84 76 65 21
7 50.09.237 50.09.267 50.13.237 50.13.267 839 481 147 156 84 76 65 21
3 50.09.333 50.09.363 50.13.333 50.13.363 583 386 63 72 125 90 90 21
4 50.09.334 50.09.364 50.13.334 50.13.364 667 428 84 93 125 90 90 21
36 5 50.09.335 50.09.365 50.13.335 50.13.365 751 470 105 114 125 90 90 21
6 50.09.336 50.09.366 50.13.336 50.13.366 835 512 126 135 125 90 90 21
7 50.09.337 50.09.367 50.13.337 50.13.367 919 554 147 156 125 90 90 21

S.r.l. 096-A050
Rev. 03 - 26/03/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "55"

- Off-circuit operation - 24 kV / 36 kV
- For oil immersed transformer - 30 A / 60 A
- Bridge connection - From 3 to 7 positions
- Regulation 2,5% per position Dimension in mm

060-96.6000
or 060-96.6020
or 060-96.6400
COVER
23 On voltage

Ø 27 H12

54
L

°
35
20
19 31

21
R 24,5 88,5
B
113

93
68,5
56

Z
18 H C F C F C E D

12 U
7 (2x)

OK
8
19

10
30

20
8

OJ
DET. N ( )

PRODUCT CODE
L= 91 L=131 mm
KV N° POS.
30 A 60 A 30 A 60 A
J= 3,1 / K= 5 J= 5,1 / K= 7 J= 3,1 / K= 5 J= 5,1 / K= 7 A B C D E F H Z
3 55.09.233 55.09.263 55.13.233 55.13.263 569 479 63 72 84 65 76 21
4 55.09.234 55.09.264 55.13.234 55.13.264 653 542 84 93 84 65 76 21
24 5 55.09.235 55.09.265 55.13.235 55.13.265 737 605 105 114 84 65 76 21
6 55.09.236 55.09.266 55.13.236 55.13.266 821 668 126 135 84 65 76 21
7 55.09.237 55.09.267 55.13.237 55.13.267 905 731 147 156 84 65 76 21
3 55.09.333 55.09.363 55.13.333 55.13.363 701 611 63 72 125 90 117 21
4 55.09.334 55.09.364 55.13.334 55.13.364 785 674 84 93 125 90 117 21
36 5 55.09.335 55.09.365 55.13.335 55.13.365 869 737 105 114 125 90 117 21
6 55.09.336 55.09.366 55.13.336 55.13.366 953 800 126 135 125 90 117 21
7 55.09.337 55.09.367 55.13.337 55.13.367 1037 863 147 156 125 90 117 21

S.r.l. 096-AF055
Rev. 02 - 28/03/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "60"

- Off-circuit operation - 24 kV / 36 kV
- For oil immersed transformer - 30 A / 60 A
- Bridge connection - From 3 to 7 positions
- Regulation 2,5% per position Dimension in mm

060-96.6000
or 060-96.6020

23 On voltage
or 060-96.6400 30
COVER
==

54
°
20
Ø 27 H12
10
L

20

I
35

24,5
21

Bu5 R 24,5 60,5 28


113
A
93
68,5

56

U
Z
OK
17 C D E C F C 17
8
10
20

OJ
( )

PRODUCT CODE
L= 91 I= 80,5 L=131 I= 120,5 mm
KV N° POS.
30 A 60 A 30 A 60 A
J= 3,1 / K= 5 J= 5,1 / K= 7 J= 3,1 / K= 5 J= 5,1 / K= 7 A B C D E F Z
3 60.09.233 60.09.263 60.13.233 60.13.263 551 227 63 105 105 118 21
4 60.09.234 60.09.264 60.13.234 60.13.264 572 216,5 84 105 84 97 21
24 5 60.09.235 60.09.265 60.13.235 60.13.265 593 227 105 84 84 76 21
6 60.09.236 60.09.266 60.13.236 60.13.266 656 248 126 84 84 76 21
7 60.09.237 60.09.267 60.13.237 60.13.267 719 269 147 84 84 76 21
3 60.09.333 60.09.363 60.13.333 60.13.363 647 275 63 146 146 132 21
4 60.09.334 60.09.364 60.13.334 60.13.364 668 264,5 84 146 125 111 21
36 5 60.09.335 60.09.365 60.13.335 60.13.365 689 275 105 125 125 90 21
6 60.09.336 60.09.366 60.13.336 60.13.366 752 296 126 125 125 90 21
7 60.09.337 60.09.367 60.13.337 60.13.367 815 317 147 125 125 90 21

S.r.l. 096-A060
Rev. 02 - 29/03/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "65"

- Off-circuit operation - 24 kV / 36 kV
- For oil immersed transformer - 30 A / 60 A
- Wye connection without take-off terminal - From 3 to 7 positions
- Regulation 2,5% per position Dimension in mm

060-96.6000
or 060-96.6020
or 060-96.6400
30
COVER
18 On voltage

==
20

Ø 27 H12

54
°
10

I
20

24,5
21
35

B u5 R 24,5 60,5 28
A 113

93
68,5
56

Z
20 G F C E D

OK
8
10
20 U

OJ

PRODUCT CODE
L= 91 I= 80,5 L=131 I= 120,5 mm
KV N° POS.
30 A 60 A 30 A 60 A
J= 3,1 / K= 5 J= 5,1 / K= 7 J= 3,1 / K= 5 J= 5,1 / K= 7 A B C D E F G Z
3 65.09.233 65.09.263 65.13.233 65.13.263 373 214 105 72 84 50 42 21
4 65.09.234 65.09.264 65.13.234 65.13.264 457 256 147 93 84 50 63 21
24 5 65.09.235 65.09.265 65.13.235 65.13.265 541 298 189 114 84 50 84 21
6 65.09.236 65.09.266 65.13.236 65.13.266 625 340 231 135 84 50 105 21
7 65.09.237 65.09.267 65.13.237 65.13.267 709 382 273 156 84 50 126 21
3 65.09.333 65.09.363 65.13.333 65.13.363 414 255 105 72 125 50 42 21
4 65.09.334 65.09.364 65.13.334 65.13.364 498 297 147 93 125 50 63 21
36 5 65.09.335 65.09.365 65.13.335 65.13.365 582 339 189 114 125 50 84 21
6 65.09.336 65.09.366 65.13.336 65.13.366 666 381 231 135 125 50 105 21
7 65.09.337 65.09.367 65.13.337 65.13.367 750 423 273 156 125 50 126 21

S.r.l. 096-A065
Rev. 02 - 29/03/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "70"

- Off-circuit operation - 24 kV / 36 kV
- For oil immersed transformer - 30 A / 60 A
- Series parallel connection
Dimension in mm

060-96.6000
or 060-96.6020
or 060-96.6400

23 On voltage
COVER 30
==

20
O 27 H12
10
L

20

I
21

24,5
35
R 24,5 60,5 28
B 113

56

ß°
C1
17 C D D C F C

U
OK
8
93

10
68,5

20

OJ

DET. M

( )

PRODUCT CODE
L= 91 I= 80,5 L=131 I= 120,5 mm
KV N° POS.
30 A 60 A 30 A 60 A
J= 3,1 / K= 5 J= 5,1 / K= 7 J= 3,1 / K= 5 J= 5,1 / K= 7 A B C C1 D F β°
2 70.09.132 70.09.162 70.13.132 70.13.162 698 262 140 35 84 76 90°
15 / 20

2 70.09.232 70.09.262 70.13.232 70.13.262 782 290 168 42 84 76 108°


10 / 20

2 70.09.332 70.09.362 70.13.332 70.13.362 962 366 196 49 125 90 126°


15 / 30

S.r.l. 096-A070
Rev. 02 - 13/04/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "75"

- Off-circuit operation - 24 kV
- For oil immersed transformer - 30 A / 60 A
- Change voltages connection
Dimension in mm

060-96.6000
or 060-96.6020

23 On voltage
or 060-96.6400
COVER

Ø 27 H12 35

31
L

20

ß°
21

19
R 24,5 88,5
B
113
A

M
N 56

17 C D D C D D C 17

12
7 (2x)

OK ( )
8
19

10

93

U
68,5
30

20
8

OJ
DET. N
DET. M

PRODUCT CODE
L=131 mm
KV N° POS.
30 A 60 A
J= 3,1 / K= 5 J= 5,1 / K= 7 A B C D Z β°
2 75.13.232 75.13.262 664 266 98 84 49 126°
24

S.r.l. 096-A075
Rev. 02 - 16/04/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "80"
- Off-circuit operation - 24 kV
- For oil immersed transformer - 30 A / 60 A
1: n. 2 bridge connection - Regulation 2,5% per position
2: n. 1 series parallel - from 3 to 5 positions
Dimension in mm

1 2 060-96.6500

23 On voltage
COVER

Ø 27 H12 Ø 27 H12
L

20
21 T=52 T=52

35
B R 24,5 88,5
113
M M

56
U 10kV-20kV

35
17 140 84 84 140 84 84 140 17
790

M
1 N
56

( )
Z
17 C D E C E D C 17
U 15kV-20kV
A

OK
7 (2x)

54°
19
8
10

93
68,5

30
20

°
90

1 2
OJ
DET. M DET. N ( )

PRODUCT CODE
L=91 mm
KV N° POS.
30 A 60 A
J= 3,1 / K= 5 J= 5,1 / K= 7 A B C D E Z
3 80.09.233 80.09.263 636 308 63 84 122,5 21
24 4 80.09.234 80.09.264 678 308 84 84 112 21
5 80.09.235 80.09.265 720 308 105 84 101,5 21

S.r.l. 096-A080
Rev. 02 - 19/04/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "10"

- Off-circuit operation - 24 kV / 36 kV
- For oil immersed transformer - 150 A
- Bridge connection - From 3 to 7 positions
- Regulation 2,5% per position Dimension in mm

060-96.6300
or 060-96.6320
or 060-96.6500
40
34 On voltage

10 COVER = =
20

O 27 H12

I
30

21

29,5
B u5 67 34
A 101

O 10 O 10
ß°
10 16,5
10 17,5

Y2 Y1
25
25

17,5

O 12

M 8 O 8,1

U
R
S
76
56

Z ( )
17 C F C F C E D

PRODUCT CODE
mm
KV N° POS. L= 91 I= 80,5 L=131 I= 120,5
Y1 - 150 A Y2 - 150 A Y1 - 150 A Y2 - 150 A A B C D E F R S Z ß°
3 10.09.203 10.09.213 10.13.203 10.13.213 587 364,5 84 86 90 71 24,5 100,5 28 72°
4 10.09.204 10.09.214 10.13.204 10.13.214 699 420,5 112 114 90 71 24,5 100,5 28 72°
24 5 10.09.205 10.09.215 10.13.205 10.13.215 811 476,5 140 142 90 71 24,5 100,5 28 72°
6 10.09.206 10.09.216 10.13.206 10.13.216 923 532,5 168 170 90 71 34 110 28 51°
7 10.09.207 10.09.217 10.13.207 10.13.217 1035 588,5 196 198 90 71 34 110 28 51°
3 10.09.303 10.09.313 10.13.303 10.13.313 675 440,5 84 86 130 95 24,5 100,5 28 72°
4 10.09.304 10.09.314 10.13.304 10.13.314 787 496,5 112 114 130 95 24,5 100,5 28 72°
36 5 10.09.305 10.09.315 10.13.305 10.13.315 899 552,5 140 142 130 95 24,5 100,5 28 72°
6 10.09.306 10.09.316 10.13.306 10.13.316 1011 608,5 168 170 130 95 34 110 28 51°
7 10.09.307 10.09.317 10.13.307 10.13.317 1123 664,5 196 198 130 95 34 110 28 51°

S.r.l. 096-A010
Rev. 02 - 06/02/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "15"

- Off-circuit operation - 24 kV / 36 kV
- For oil immersed transformer - 150 A
- Bridge connection - from 3 to 7 positions
- Regulation 2,5% per position Dimension in mm

060-96.6300
or 060-96.6320
34 On Voltage

or 060-96.6500
COVER

L
30
19 31

21
B 101
A

M
N
56

ß°
Z
18 H C F C F C E D

12
7 (2x)

O 10 O 10
U
R
21,5

10 16,5

10 17,5

Y1 Y2
30

76
25
17,5

25

O 12
15,5

O 8,1 M 8
DET. N
( )
DET. M

PRODUCT CODE
mm
KV N° POS. L= 91 I= 80,5 L=131 I= 120,5
Y1 - 150 A Y2 - 150 A Y1 - 150 A Y2 - 150 A A B C D E F H R S ß° Z
3 15.09.203 15.09.213 15.13.203 15.13.213 670 566 84 86 90 71 82 24,5 100,5 72° 28
4 15.09.204 15.09.214 15.13.204 15.13.214 782 650 112 114 90 71 82 24,5 100,5 72° 28
24 5 15.09.205 15.09.215 15.13.205 15.13.215 894 734 140 142 90 71 82 24,5 100,5 72° 28
6 15.09.206 15.09.216 15.13.206 15.13.216 1006 818 168 170 90 71 82 34 110 51° 28
7 15.09.207 15.09.217 15.13.207 15.13.217 1118 902 196 198 90 71 82 34 110 51° 28
3 15.09.303 15.09.313 15.13.303 15.13.313 798 694 84 86 130 95 122 24,5 100,5 72° 28
4 15.09.304 15.09.314 15.13.304 15.13.314 910 778 112 114 130 95 122 24,5 100,5 72° 28
36 5 15.09.305 15.09.315 15.13.305 15.13.315 1022 862 140 142 130 95 122 24,5 100,5 72° 28
6 15.09.306 15.09.316 15.13.306 15.13.316 1134 946 168 170 130 95 122 34 110 51° 28
7 15.09.307 15.09.317 15.13.307 15.13.317 1246 1030 196 198 130 95 122 34 110 51° 28

S.r.l. 096-A015
Rev. 02 - 30/03/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "20"

- Off-circuit operation - 24 kV / 36 kV
- For oil immersed transformer - 150 A
- Bridge connection - from 3 to 7 positions
- Regulation 2,5% per position Dimension in mm

060-96.6300
or 060-96.6320

34 On Voltage
or 060-96.6500 40
COVER
= =

20
O 27 H12
L

10

I
30
21

Bu5

29,5
67 34
A
101

ß°
56
Z
17 C D D C F C 17
R

O 10 U
O 10
10 16,5

10 17,5

S
76

Y1 Y2
25
17,5

25

O 12

O 8,1 M 8

DET. M ( )

PRODUCT CODE
mm
KV N° POS. L= 91 I= 80,5 L=131 I= 120,5
Y1 - 150 A Y2 - 150 A Y1 - 150 A Y2 - 150 A A B C D F R S Z ß
3 20.09.203 20.09.213 20.13.203 20.13.213 649 265,5 84 118 127 24,5 100,5 28 72°
4 20.09.204 20.09.214 20.13.204 20.13.214 677 265,5 112 104 99 24,5 100,5 28 72°
24 5 20.09.205 20.09.215 20.13.205 20.13.215 705 265,5 140 90 71 24,5 100,5 28 72°
6 20.09.206 20.09.216 20.13.206 20.13.216 789 293,5 168 90 71 34 110 28 51°
7 20.09.207 20.09.217 20.13.207 20.13.217 873 321,5 196 90 71 34 110 28 51°
3 20.09.303 20.09.313 20.13.303 20.13.313 641 261,5 84 130 95 24,5 100,5 28 72°
4 20.09.304 20.09.314 20.13.304 20.13.314 725 289,5 112 130 95 24,5 100,5 28 72°
36 5 20.09.305 20.09.315 20.13.305 20.13.315 809 317,5 140 130 95 24,5 100,5 28 72°
6 20.09.306 20.09.316 20.13.306 20.13.316 893 345,5 168 130 95 34 110 28 51°
7 20.09.307 20.09.317 20.13.307 20.13.317 977 373,5 196 130 95 34 110 28 51°

S.r.l. 096-A020
Rev. 02 - 17/04/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "22D"

- Off-circuit operation - 24 kV / 36 kV
- For oil immersed transformer - 150 A
- Bridge connection - from 3 to 7 positions
- Regulation 2,5% per position Dimension in mm

060-96.6500

34 On voltage
ß°
COVER

31
30
L
T=52

7 21
21

19
B
A 101

M
N

56

Z
17 C D D C E E C 17

12
R

7 (2x)

O 10 O 10
21,5
10 17,5
10 16,5

30
76

Y1 Y2
15,5
25
25
17,5

O 12
( )

O 8,1 M 8
DET. N
DET. M

PRODUCT CODE
mm
KV N° POS. L= 91 L=131
Y1 - 150 A Y2 - 150 A Y1 - 150 A Y2 - 150 A A B C D E R S Z ß°
3 22D09.203 22D09.213 22D13.203 22D13.213 630 256 84 90 82 24,5 100,5 28 72°
4 22D09.204 22D09.214 22D13.204 22D13.214 714 284 112 90 82 24,5 100,5 28 72°
24 5 22D09.205 22D09.215 22D13.205 22D13.215 798 312 140 90 82 24,5 100,5 28 72°
6 22D09.206 22D09.216 22D13.206 22D13.216 882 340 168 90 82 34 110 28 51°
7 22D09.207 22D09.217 22D13.207 22D13.217 966 368 196 90 82 34 110 28 51°
3 22D09.303 22D09.313 22D13.303 22D13.313 790 336 84 130 122 24,5 100,5 28 72°
4 22D09.304 22D09.314 22D13.304 22D13.314 874 364 112 130 122 24,5 100,5 28 72°
36 5 22D09.305 22D09.315 22D13.305 22D13.315 958 392 140 130 122 24,5 100,5 28 72°
6 22D09.306 22D09.316 22D13.306 22D13.316 1042 420 168 130 122 34 110 28 51°
7 22D09.307 22D09.317 22D13.307 22D13.317 1126 448 196 130 122 34 110 28 51°

S.r.l. 096-A022D
Rev. 02 - 20/4/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "25"

- Off-circuit operation - 24 kV / 36 kV
- For oil immersed transformer - 150 A
- Series parallel connection
Dimension in mm

060-96.6300
or 060-96.6320

34 On voltage
or 060-96.6500
COVER

Ø 27 H12

31

30
L

19
21

B R 24,5 101
A 125,5

M
N

56
C1
17 C D D C E E C 17

ß°
12
U
7 (2x)

O 10 O 10
21,5
10 16,5

100,5
10 17,5

30

Y1
76

Y2
25
17,5

25

O 12
15,5

O 8,1 M 8
DET. N
DET. M ( )

PRODUCT CODE
mm
KV N° POS. L= 91 L=131
Y1 - 150 A Y2 - 150 A Y1 - 150 A Y2 - 150 A A B C C1 D E ß°

10 / 20 2 25.09.202 25.09.212 25.13.202 25.13.212 882 340 168 42 90 82 108°

15 / 30 2 25.09.302 25.09.312 25.13.302 25.13.312 1126 448 196 49 130 122 126°

S.r.l. 096-A025
Rev. 02 - 13/04/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "27"

- Off-circuit operation - 24 kV / 36 kV
- For oil immersed transformer - 150 A
- Series parallel connection
Dimension in mm

060-96.6300
or 060-96.6320
or 060-96.6500
34 On Voltage

COVER

O 27 H12
30

L
19 31

21
R 24,5 101
B 125,5
A

M
N
56

56

ß°
C1
18 H C F C F C E D

12
U
7 (2x)

O 10 O 10
100,5
21,5

10 17,5
10 16,5

76

Y1 Y2
30

25
25
17,5

O 12

O 8,1 M 8
15,5

DET. M
DET. N
( )

PRODUCT CODE
mm
KV N° POS. L= 91 L=131
Y1 - 150 A Y2 - 150 A Y1 - 150 A Y2 - 150 A A B C C1 D E F ß° H

10 / 20 2 27.09.202 27.09.212 27.13.202 27.13.212 908 818 168 42 72 90 71 108° 82

15 / 30 2 27.09.302 27.09.312 27.13.302 27.13.312 1127 1030 196 49 79 130 95 126° 122

S.r.l. 096-A027
Rev. 02 - 14/04/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "30"

- Off-circuit operation - 24 kV
- For oil immersed transformer - 150 A
- Change Voltages connection
Dimension in mm

060-96.6300
or 060-96.6320
or 060-96.6500
COVER

34 On voltage
Ø 27 H12

ß°
L

31

30
21

19
B R 24,5 101

A 125,5

M
N

56

Z
U
17 C D D C E E C 17

12

O 10 ( )
O 10
7 (2x)

21,5
10 16,5

100,5
10 17,5

U
Y1
76

30

Y2
25
17,5

25

O 12
15,5

O 8,1 M 8
DET. N
DET. M

PRODUCT CODE
mm
KV N° POS. L=131
Y1 - 150 A Y2 - 150 A A B C D E Z β°
2 30.13.202 30.13.212 672 270 98 90 82 49 126°
24

S.r.l. 096-A030
Rev. 02 - 13/04/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "35"
- Off-circuit operation - 24 kV
- For oil immersed transformer - 150 A
1: n. 2 bridge connection - Regulation 2,5% per position
2: n. 1 series parallel - from 3 to 7 positions
Dimension in mm

1 2 060-96.6500

34 On voltage
COVER

Ø 27 H12 Ø 27 H12
L
21 T=52 T=52

30
B R 24,5 101
125,5
M M
2
U 10kV-20kV

56
42
17 168 90 90 168 90 90 168 17
G

M
1 N 56

( )

28 U 15kV-20kV
17 140 90 104 140 104 90 140 17
A
12
7 (2x)
24,5

OK
72°
21,5
8

100,5

30
10

76


20

10

1 2
15,5

OJ ( )
DET. M DET. N

PRODUCT CODE
mm
KV N° POS. L=91
Y1 - 150 A Y2 - 150 A A B C D E F G S
3 35.09.203 35.09.213 730 348 84 90 132 90 898 100,5
4 35.09.204 35.09.214 786 348 112 90 118 90 898 100,5
24 5 35.09.205 35.09.215 842 348 140 90 104 90 898 100,5
6 35.09.206 35.09.216 898 348 168 90 90 90 898 110
7 35.09.207 35.09.217 982 376 196 90 90 104 926 110

S.r.l. 096-A035
Rev. 02 - 20/04/2012
tap changers
THREE PHASE TAP CHANGERS TYPE "40"

- Off-circuit operation - 24 kV / 36 kV
- For oil immersed transformer - 150 A
- wye connection with take-off terminal - From 3 to 7 positions
- Regulation 2,5% per position Dimension in mm

060-96.6300
or 060-96.6320

34 On voltage
or 060-96.6500
COVER

12
5 5
Ø 27 H12 B

30

52
89
25
B1 B2 7,5 84,5
A

22 49,5 7,5

M
DET. B

77
30 7 (2x)

ß°
70 C 35 E E C 35 E C 35 20
R

O 10 U
10 17,5

U
S
76
25

M 8
( ) ( )
DET. M

PRODUCT CODE
mm
KV N° POS. L= 91 L=131
150 A A B1 B2 C E R S Z ß
3 40.09.213 40.13.213 633 222 222 56 90 24,5 100,5 28 72°
4 40.09.214 40.13.214 717 250 250 84 90 24,5 100,5 28 72°
24 5 40.09.215 40.13.215 801 280 280 112 90 24,5 100,5 28 72°
6 40.09.216 40.13.216 885 306 306 140 90 34 110 28 51°
7 40.09.217 40.13.217 969 334 334 168 90 34 110 28 51°
3 40.09.313 40.13.313 753 262 286 56 130 24,5 100,5 28 72°
4 40.09.314 40.13.314 837 290 314 84 130 24,5 100,5 28 72°
36 5 40.09.315 40.13.315 921 318 342 112 130 24,5 100,5 28 72°
6 40.09.316 40.13.316 1005 346 370 140 130 34 110 28 51°
7 40.09.317 40.13.317 1089 374 398 168 130 34 110 28 51°

S.r.l. 096-A040
Rev. 04 - 16/04/2012
tap changers
TAP CHANGER COUPLING

Dimension in mm

T min. = 52

For special applications, a stacking arrangement can be utilised for the off-circuit tap selectors.
Dimensions T= min. 52 mm can be increased for insulation purposes.

S.r.l. 096-01
Rev. 01 - 20/04/2012
tap changers
DRIVE TYPE 060-95.6000 (x 30/60 A)
060-95.6300 (x 150 A)

Drive handle on lid from 2 to 7 positions


Dimension in mm

O 70 36,25
Max. thickness 10 mm

MAX. O 7
(72)
+0,21
Drill O 27 H12 0

I
A) Gear group
B) Transformer cover
C) O-Ring seal H
D) Tightener O-Ring washer
E) Thickness washers G
(To be used depending on cover thickness - i.e. 5pcs
for 5mm thickness; 2pcs for 8mm thickness; etc.) F
F) Positioning ring
G) Nut
H) Flat gasket
I) Aluminium knob
L) Red washer E
M) Screw

S.r.l. 096-60-02
Rev. 00 - 03/04/2012
tap changers
DRIVE TYPE 060-95.6020 (x 30/60 A)
060-95.6320 (x 150 A)

Drive handle on lid from 2 to 7 positions


Dimension in mm

O 88,5 57,5

Max. thickness 10 mm

MAX. O 7
86
24

+0,21
Drill O 27 H12 0

A) Gear group M
B) Transformer cover
C) O-Ring seal L
D) Zama base for protective cover I
E) Thickness washers
(To be used depending on cover thickness - i.e. 5pcs
for 5mm thickeness; 2pcs for 8mm thickeness; etc.) H
F) Positioning ring
G) Nut G
H) Flat gasket F
I) Aluminium knob
L) Red washer
M) Screw
N) Zama protective cover E

S.r.l. 096-60-03
Rev. 00 - 03/04/2012
tap changers
DRIVE TYPE 060-95.6400 (x 30/60 A)
060-95.6500 (x 150 A)

Drive handle on lid from 2 to 7 positions


Dimension in mm

O 102

(125)
Max. thickness 10 mm

MAX. O 7
+0,21
Drill O 27 H12 0
L

A) Gear group
B) Transformer cover
C) O-Ring seal
D) Tightener O-Ring washer H
E) Thickness washers
(To be used depending on cover thickness - i.e. 5pcs G
for 5mm thickness; 2pcs for 8mm thickness; etc.) F
F) Positioning ring
G) Nut
H) Flat gasket
I) Aluminium with handle
L) Screw E

D
C
B

S.r.l. 096-60-04
Rev. 00 - 03/04/2012
tap changers
DRIVE HANDLE NUMBERING DISKS

REGULATION

S.O. S.A.

096-SO4 096-SA4

5 4 3 2 1 1 2 3 4 5

CHANGE VOLTAGE

S.O. S.A.

096-SO2 096-SA2

2 1 1 2

S.r.l. 096-60-05
Rev. 00 - 02/04/2012
tap changers