SET THE FOLLOWING PARAMETERS ON THE MACHINE

You need to execute the following command on the


MOU,/TY1,1,3
machine for set communication parameters

SET THE FOLLOWING PARAMETERS ON THE PC


SERIAL PORT TAB

Machine name Allen Bradley 8600

Serial port COM2 (or any free COM port)

Baud 1200

Data bits 7

Parity Even

Stop bits 2

DATA FLOW CONTROL TAB

Use DTR False

Use RTS True

Require DSR False

Require CTS True

Set RTS False


Set DTR False

Software flowcontrol None

Xon char #11

Xoff char #13

DATA EXCHANGE FORMAT TAB

Format mode Uniform

Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Format parameters
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Straight cable, without handshake


PC, 9pin, DB9M | CNC, 25pin, DB25

Straight cable, with full handshake


PC, 9pin, DB9M | CNC, 25pin, DB25

Straight cable, without handshake


PC, 25pin, DB25M | CNC, 25pin, DB25
Straight cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25

Allen Bradley 9 Series configuration document

CNC Configuration Sheet


Allen-Bradley / 9-Series

CNC Parameters:
You will need to verify all parameters listed below that correspond to your CNC control.

These parameters may not match your particular machine’s control.

Document (Phone camera) original settings before making modifications.

Device Parameters for either port A or port B

Device = Generic Level 2


Baud Rate = 9600

Protocol = Level_2

Output Code = ASCII

Auto Filename = NO

Stop PRG END = YES

PRG END Code = M02, M30, M99

FactoryWiz DNC Settings:


Basic Communication

1.01- Port Type: Standard

1.11- Baud: 9600

1.12- Data Bits: 7


1.13- ASCII Even

1.14- Stop Bits: 1

1.15- Handshake: XON/XOFF

Sending Options

2.11- Leader: %<10>

2.12- Trailer: %<4>

2.23- Skip lines that contain: %

2.31- Automatic timeout: 7

Receiving Options

3.11- Program identifier 1: O

3.12- Program Identifier 2: :

3.21- Receive timeout: 3

3.31- Ignore data before first end-of-block: True

3.32- Ignore data after last end-of-block: True

Remote Commands

4.02- Request for file command: GET-

4.03- Request for file command (drip feed): DNC-

4:11- Request to save command: PUT-


Additional Notes:

Below examples use port B.


Outputting CNC Programs:

Select Program Manage softkey.

Select Copy Program Softkey.

Enter Program number.

Select MEM to Port B.

Select Single Program.

The selected program will now be sent.

Inputting CNC Programs using the FactoryWiz Client:

Log into FactoryWiz Client and select the machine for file transfer.

Click on Send File.

Select the file to be sent, then click on Send File (Once)

At the AB9 control:

Select Program Manage softkey.

Select Copy Program Softkey.

Enter Program number.

Select Port B to MEM.

Select Single Program.

The selected program will now load.


Wiring Diagram:
Pinout includes RTS/CTS Handshaking

DB-9 com port Wire color DB-25 CNC Jumper?

(Disconnected) Shield 1
2 (Receive Data) Green 2 (Transmit Data)
3 (Transmit Data) Red 3 (Receive Data)
5 (Signal Ground) Black 7 (Signal Ground)
7 (RTS) Brown 5 (CTS)
8 (CTS) Blue 4 (RTS)
6 (DSR) JUMPER

8 (DCD)

20 (DTR)

You might also like