5 COST ESTIMATE
FOR SECURITY &
SURVEILLANCE SYSTEMS
T.I.
Description Quantity Unit
No.
Supplying and laying following sizes one number PVC insulated, PVC sheathed, steel armoured, copper
1830
conductor controle cable of 1.1 KV grade in exiting PVC/ GI pipe etc as required.
a. 3 x 1.5 sq. mm FRLS cable 6000 Mt.
Supplying and drawing UTP 4 pair Cat 6 LAN cable in existing surface/ concealed steel/ PVC conduit
1831 6000 Mt.
as required.
Supply, Installation, Testing & Commissioning of 20 KVA online UPS with 30 min Battery backup 3
1832 2 No.
phase output.
D Access Control System
SITCI of -Single Door Access Controller with 2 reader interface per door and with necessary mounting
1833 hardware & accessories as per 28 Nos.
technical specification.
SITCI of - Two Door Access Controller with 1 reader interface per door and with necessary mounting
1834 hardware & accessories as per 14 Nos.
technical specification.
SITCI of - Wall Mounted Weatherproof Type Panel/ Enclosure for door controller including with double
1835 compressed nickel plated cable 10 Nos.
glands and accessories.
SITCI of - Access Card + Biometric fingerprint
1836 100 Nos.
reader as per specifications
SITCI of - Single leaf Electromagnetic Locks with mounting bracket, Shall have holding force up to
1837 30 Nos.
600 lbs (272 kg).
SITCI of - Double leaf Electromagnetic Locks with
1838 12 Nos.
mounting bracket, Shall have holding force up to 1200 lbs (545 kg).
Supply , Installation , Testing and comissioning of CAT 6A UTP LAN Cable. 4 Pair CAT6A
LHOS
1858 Unshielded, Twisted Pair (U/UTP) Cable 500 mtr per Box. Yellow (RAIL 1018) in colour conforming to 12600 Mtr.
the following standards like EIA/TIA 568-C.2, EN50173, EN52288, IEC 11801, IEC 61156-5,
500Mhz etc. Cat 6A U/UTP cable with minimum bending radius when laying(mm) is 36
Supply , Installation , Testing and comissioning of CAT6A 7 feet patch cord for user & rack side
1859 280 Nos.
termination
1860 Supply , Installation , Testing and comissioning of 2 port face plate white for I/O fixing at user side 140 Nos.
1861 9 U wall mount rack including with necessary accessory such as power cord, cable manager etc. 6 Nos.
F IP Telephony
Supply, Installation, Testing & commissioning of Access Switch 48x10/100/1000 PoE+ RJ45
1862 Ethernet with minimum 370 PoE Switch should 2 Nos.
have 2 ports of 10G SFP
Supply, Installation, Testing & commissioning of Access Switch 24x10/100/1000 PoE+ RJ45
1863 Ethernet with minimum 370 PoE Switch should 8 Nos.
have 2 ports of 10G SFP
SITC of EPABX 6 x 28 P&T (6 TRUNK / 4 DIGITAL /
1864 1 Nos.
28 SLT) EXPANDABLE UPTO 256 EXT )
1865 SITC of IP-telephone instrument desk top/ wall mount unit 65 Nos.
1866 Supply , Installation , Testing and comissioning of 2 port face plate white for I/O fixing at user side 65 Nos.
Supply , Installation , Testing and comissioning of CAT 6A UTP LAN Cable. 4 Pair CAT6A
LHOS
1869 Unshielded, Twisted Pair (U/UTP) Cable 500 mtr per Box. Yellow (RAIL 1018) in colour conforming to 4000 Mtr.
the following standards like EIA/TIA 568-C.2, EN50173, EN52288, IEC 11801, IEC 61156-5,
500Mhz etc. Cat 6A U/UTP cable with minimum bending radius when laying(mm) is 36