Item Rate BoQ

Validate Print Help

Tender Inviting Authority: GARRISON ENGINEER GOLCONDA HYDERABAD 500008

Contract No: GE/GOL/ OF 2024-2025 Serial Page No.


Name of Work: GUINITING AND GROUTING OF OHT AND UG SUMPS INCLUDING PAINTING OF STORAGE TANKS AND OTHER MISC WORKS UNDER GE GOLCONDA
Bidder
Name :
PRICE SCHEDULE
(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and
Values only )
Sl. Item Description Quantity Units RATE including TOTAL AMOUNT TOTAL AMOUNT
No. Taxes In Figures In Words
To be entered by
the Bidder
Rs. P
1 2 3 4 5 6 7
1.00 M&L for pressure gunniting/shotcreting for columns / beams surfaces of overhead resoirvoir (OHT) 112.00 Sqm 0.00 INR Zero Only
including water proofing by Epoxy coating of any size and staging height upto 24.00 metre by using
mechanical means and necessary scaffolding complete all as specified and as directed. :-
Notes:-
Stages for gunniting/shotcreting columns/beam surfaces:-
(a) Dismantling/taking down loose /spalling /unsound cement concrete layers average depth 25mm from
the Columns/beams and dispose off unserviceable debris and rubbish outside MD land.
(b) Preparation of exposed reinforcement (i.e. including cutting of all edges, roughening the smooth
surfaces, scrapping out / removing corrosion all loose / scale / rust etc from visible reinforcement by
applying rust remover Reebaklens RR (3-4 Sqm per litre) or epoxy coated bonding agent or equivalent of
Chemco system / Webac chemical and trimming cleaning the steel reinforcement properly) of
beam/columns surfaces.
(c) Insertion of additional Reinforcement .
(Reinforcement will be measured separtely)
(d) Applying two Coats to the exposed reinforcement by ReArm Coat- Zp or equivalent of Chemco
system / Webac chemicals on visible reinforcement surfaces to form a continious dry film not less than
80 micron thick a reinforcement epoxy.
(e) Gunniting/Shotcrete the damaged portion with cement mortar mixed with Aqua Arm bond latex and
then plastering.
Contract No: GE/GOL/ OF 2024-2025 Serial Page No.
Name of Work: GUINITING AND GROUTING OF OHT AND UG SUMPS INCLUDING PAINTING OF STORAGE TANKS AND OTHER MISC WORKS UNDER GE GOLCONDA
Bidder
Name :
2.00 M&L for water proofing by grouting & Epoxy coating for wall/floor surfaces of RCC UG Sump/ Semi UG 723.00 Sqm 0.00 INR Zero Only
Sump of any size and any height / depth by using mechanical means and necessary scaffolding
complete all as specified and as directed. :-
Notes:-
Stages for water proofing by nozzle grouting & Epoxy Coating wall/floor surfaces:-
(a) Dismantling loose /spalling /unsound cement concrete layers from the wall/floor or racking out
surfaces and disposed up unserviceable debris and rubbish outside MD land.
(b) Cutting of the construction joints in 'V' shaped grooves.
(c) Drilling of holes for pressure grouting of 10mm to 15 mm dia., 100 to 150mm deep at the intervals of
350 mm c/c on RCC structural members surfaces in staggered manner in the honeycomb / seepage
portions and cleaning of holes by air blower prior to fixing nozzles.
(d) Patching the entire 'v' shaped grooves with cement, admixed with quick setting compound .
(e) Fixing of PVC nozzles for grouting with quick setting compound admixed with cement.
(f) Next grouting is to be done with cement mixture with CEBEX-100 through nozzle by high pressure
injection pump incl rendering 15mm thick with CM(1:6). All these operations are made from
inside/outside of the reservoir and arrange all necessary scaffolding needed to complete the entire
procedure.
(g) Water testing of the tanks by filling the tanks with water and for successfully prevention of the water
leakage switch over to the next level for expoxy coating.
(h) Applying a coat of floor/wall surfaces with cementitious acrylic polymer coat Aqua Arm Topguard.
(j) Water to be made empty and a water proofing coating to be made in 2 coats in the inner wall and
floor of the tank with water based epoxy Aqua Arm Tank Coat (Potable Water grade).

3.00 M&L for water proofing by grouting & Epoxy coating for wall/floor surfaces of RCC Over head resoirvoir 835.00 Sqm 0.00 INR Zero Only
(OHT) of any size and staging height upto 24.00 metre by using mechanical means and necessary
scaffolding complete all as specified and as directed. :-
Notes:-
Stages for water proofing by nozzle grouting & Epoxy Coating wall/floor surfaces:-
(a) Dismantling loose /spalling /unsound cement concrete layers from the wall/floor or racking out
surfaces and disposed up unserviceable debris and rubbish outside MD land.
(b) Cutting of the construction joints in 'V' shaped grooves.
(c) Drilling of holes for pressure grouting of 10mm to 15 mm dia., 100 to 150mm deep at the intervals of
350 mm c/c on RCC structural members surfaces in staggered manner in the honeycomb / seepage
portions and cleaning of holes by air blower prior to fixing nozzles.
(d) Patching the entire 'v' shaped grooves with cement, admixed with quick setting compound .
(e) Fixing of PVC nozzles for grouting with quick setting compound admixed with cement.
(f) Next grouting is to be done with cement mixture with CEBEX-100 through nozzle by high pressure
injection pump incl rendering 15mm thick with CM(1:6). All these operations are made from
inside/outside of the reservoir and arrange all necessary scaffolding needed to complete the entire
procedure.
(g) Water testing of the tanks by filling the tanks with water and for successfully prevention of the water
leakage switch over to the next level for expoxy coating.
(h) Applying a coat of floor/wall surfaces with cementitious acrylic polymer coat Aqua Arm Topguard.
(j) Water to be made empty and a water proofing coating to be made in 2 coats in the inner wall and
floor of the tank with water based epoxy Aqua Arm Tank Coat (Potable Water grade).

4.00 M&L for removing loose plasters and concrete layers from the roof, ceilings, beams and 223.00 Sqm 0.00 INR Zero Only
columns etc including all necessary scaffolding and disposing off debris outside of cantonment
complete all as specified and as directed.

5.00 M&L for Preparation of exposed reinforcement by using rust remover to remove all rust 223.00 Sqm 0.00 INR Zero Only
complete all as specified and as directed.
Contract No: GE/GOL/ OF 2024-2025 Serial Page No.
Name of Work: GUINITING AND GROUTING OF OHT AND UG SUMPS INCLUDING PAINTING OF STORAGE TANKS AND OTHER MISC WORKS UNDER GE GOLCONDA
Bidder
Name :
6.00 M&L for coating the exposed reinforcement by Re Arm Coat - ZP (Reinforcement epoxy) 223.00 Sqm 0.00 INR Zero Only
complete all as specified and as directed.
7.00 M&L for layering the old concrete with Re-Arm super bond a solvent free epoxy resin bonding 223.00 Sqm 0.00 INR Zero Only
agent which will act as a bonding agent between old and new concrete including necessary
formwork, scaffolding and cement etc. complete all as specified and as directed.

8.00 M&L for backing the entire surface with concrete mortar prepared with 6mm stone aggregates, 223.00 Sqm 0.00 INR Zero Only
sand and cement including necessary formwork, scaffolding etc.complete all as specified and
as directed.
9.00 M&L for 15 mm thick plastering the entire backed roof/beams/columns/walls mixed with Aqua 223.00 Sqm 0.00 INR Zero Only
Arm Bond Latex including necessary formwork, scaffolding and cement etc. complete all as
specified and as directed.
10.00 Supply only BRC welded wire mesh as additional reinforcement wherever required including 500.00 Kg 0.00 INR Zero Only
necessary fixing arrangement such as nuts & bolts, anchors etc. complete all as specified and
as directed.
11.00 Supply only chicken wire mesh for plastering of concrete surfaces wherever required incl 50.00 Sqm 0.00 INR Zero Only
necessary fixing arrangement complete all as specified and as directed

12.00 M&L for complete removal of existing treatment and preparation of old / new plastered surfaces 3165.00 Sqm 0.00 INR Zero Only
and applying two coat (Base Coat and Top Coat) of exterior weather coat emulsion paint over
primer of following brands : (i) Asian Paints - Ultima Protek (ii) Berger Paints - Weather Coat
Long Life (iii) Nerolac Paints - Suraksha superior protection for "overhead tanks staging ht
upto 24.00 metre" compelete all as directed.

13.00 M & L preparation of old decorated surfaces of walls plastered or unplastered by brooming 220.00 Sqm 0.00 INR Zero Only
down or steel wire brushing, scrapping down smoke soots, moulds, moss and efflorecent salts
and treading oil and greasy spots etc and applying one coat of white wash to walls .

14.00 M&L for complete removal of existing treatment and preparation of old / new plastered surfaces 851.00 Sqm 0.00 INR Zero Only
and applying two coat (Base Coat and Top Coat) of exterior weather coat emulsion paint over
primer of following brands : (i) Asian Paints - Ultima Protek (ii) Berger Paints - Weather Coat
Long Life (iii) Nerolac Paints - Suraksha superior protection for "UNDERGROUND SUMPS"
compelete all as directed.
Total in Figures 0.00 INR Zero Only

Quoted Rate in Words INR Zero Only