QCF-102 Sheet: 1 of 3

TPC Offshore Wind Power Generation Phase II Project - Offshore SubStation (OSS)

FIT UP INSPECTION REPORT FOR STRUCTURE

Owner/Client Name: Taiwan Power Company Report No.: OSS-FU-S-JK-0004


Employer: Foxwell Energy Corporation Ltd. Date of inspection: 12-Dec-2023
Contractor (SFE): Shinfox Far East Company Pte Ltd Location: PVMS (VUNGTAU)
Subcontractor: Petrovietnam Marine Shipyard J/S Company (PVMS) Procedure No: OSS-WPS-PVS-S002/S007
Acceptable Level: DNV-OS-C401-2023

No Drawing No. Sheet Rev Joint No. Result Remark

1 OWP2-PVMS-OSS-DWG-00043-AS-02 1/1 2 LS12 ACC


2 OWP2-PVMS-OSS-DWG-00043-AS-02 1/1 2 LS11 ACC
3 OWP2-PVMS-OSS-DWG-00043-AS-04 1/1 2 LS29 ACC
4 OWP2-PVMS-OSS-DWG-00043-AS-04 1/1 2 LS34 ACC
5 OWP2-PVMS-OSS-DWG-00043-AS-05 1/1 2 LS42 ACC
6 OWP2-PVMS-OSS-DWG-00043-AS-05 1/1 2 LS41 ACC
7 OWP2-PVMS-OSS-DWG-00043-AS-06 1/1 2 LS48 ACC
8 OWP2-PVMS-OSS-DWG-00043-AS-07 1/1 2 LS55 ACC
9 OWP2-PVMS-OSS-DWG-00043-AS-07 1/1 2 LS53 ACC
10 OWP2-PVMS-OSS-DWG-00043-AS-08 1/1 2 LS60 ACC
11 OWP2-PVMS-OSS-DWG-00043-AS-08 1/1 2 LS61 ACC

ABBREVIATION ACC: ACCEPTABLE REJ: REJECTED


PV SHIPYARD CONTRACTOR CA EMPLOYER
Name: Vu Hoang Anh Name: Name: Name:
Signature: Signature: Signature: Signature:

Date: Date: Date: Date:


QCF-102 Sheet: 2 of 3

TPC Offshore Wind Power Generation Phase II Project - Offshore SubStation (OSS)

FIT UP INSPECTION REPORT FOR STRUCTURE

Owner/Client Name: Taiwan Power Company Report No.: OSS-FU-S-JK-0007


Employer: Foxwell Energy Corporation Ltd. Date of inspection: 18-Dec-2023
Contractor (SFE): Shinfox Far East Company Pte Ltd Location: PVMS (VUNGTAU)
Subcontractor: Petrovietnam Marine Shipyard J/S Company (PVMS) Procedure No: OSS-WPS-PVS-S002/S007
Acceptable Level: DNV-OS-C401-2023

No Drawing No. Sheet Rev Joint No. Result Remark

1 OWP2-PVMS-OSS-DWG-00038-AS-17 1/1 5 LS38 ACC


2 OWP2-PVMS-OSS-DWG-00038-AS-21 1/1 5 LS05 ACC
3 OWP2-PVMS-OSS-DWG-00038-AS-21 1/1 5 LS06 ACC
4 OWP2-PVMS-OSS-DWG-00038-AS-22 1/1 5 LS14 ACC
5 OWP2-PVMS-OSS-DWG-00038-AS-22 1/1 5 LS18 ACC
6 OWP2-PVMS-OSS-DWG-00039-AS-14 1/1 5 LS44 ACC
7 OWP2-PVMS-OSS-DWG-00039-AS-19 1/1 5 LS16 ACC
8 OWP2-PVMS-OSS-DWG-00039-AS-19 1/1 5 LS17 ACC
9 OWP2-PVMS-OSS-DWG-00039-AS-19 1/1 5 LS19 ACC
10 OWP2-PVMS-OSS-DWG-00039-AS-19 1/1 5 LS23 ACC
11 OWP2-PVMS-OSS-DWG-00039-AS-21 1/1 5 LS10 ACC
12 OWP2-PVMS-OSS-DWG-00039-AS-21 1/1 5 LS11 ACC
13 OWP2-PVMS-OSS-DWG-00041-AS-03 1/1 3 LS09 ACC

ABBREVIATION ACC: ACCEPTABLE REJ: REJECTED


QCF-102 Sheet: 3 of 3

TPC Offshore Wind Power Generation Phase II Project - Offshore SubStation (OSS)

FIT UP INSPECTION REPORT FOR STRUCTURE

Owner/Client Name: Taiwan Power Company Report No.: OSS-FU-S-JK-0007


Employer: Foxwell Energy Corporation Ltd. Date of inspection: 18-Dec-2023
Contractor (SFE): Shinfox Far East Company Pte Ltd Location: PVMS (VUNGTAU)
Subcontractor: Petrovietnam Marine Shipyard J/S Company (PVMS) Procedure No: OSS-WPS-PVS-S002/S007
Acceptable Level: DNV-OS-C401-2023

No Drawing No. Sheet Rev Joint No. Result Remark

PV SHIPYARD CONTRACTOR CA EMPLOYER


Name: Vu Hoang Anh Name: Name: Name:
Signature: Signature: Signature: Signature:

Date: Date: Date: Date: