4

T60 T35 745

TRANSFORMER PROTECTION
T60 TRANSFORMER PROTECTION SYSTEM High-speed, three-phase, multiple winding transformer protection system. 65

The T60, a member of the UR Family of protection relays, is a three-phase, multiple winding, transformer relay intended for the primary protection and management of small, medium and large power transformers. Includes a full featured set of protection, I/O, data logging, and communications capabilities. T35 TRANSFORMER PROTECTION SYSTEM Cost effective transformer protection for up to six windings. 71

The T35, a member of the UR Family, is a digital threephase transformer relay designed to protect any size of power transformer with up to six windings/restraints. The T35 has a more focused protection feature set than the T60, yet still has all the I/O, data logging, and communications options 745 TRANSFORMER PROTECTION SYSTEM High-speed draw-out multiprocessor-based relay for transformer protection and management. 77

The 745 Transformer Protection System, a member of the SR Family of protection relays, is a high-speed, multiprocessor-based, three-phase, two or three-winding transformer management relay intended for the primary protection and management of small, medium and large power transformers. In a draw case, it also includes analog inputs and outputs, while incorporating advanced features such as transformer loss of life monitoring.

www.GEMultilin.com

63

TRANSFORMER PROTECTION Selector Guide


T35

T60

745

4 FEATURES
Differential Instantaneous Differential Maximum Number of Windings Dual Slope Characteristic Harmonic Restraint Internal Winding Phase Shift Compensation Dynamic CT Ratio-Matching CT Mismatch Range Unrestrained Operation Restricted Earth Fault Overexcitation Phase Undervoltage IOC, Ground/Neutral/Phase/Negative Sequence IOC, Sensitive Ground TOC, Ground/Neutral/Phase/Negative Sequence TOC, Sensitive Ground Breaker Failure Custom programmable overcurrent curves Overvoltage, Neutral/Phase/Auxiliary Overvoltage, Symmetrical Component Current Directional, Ground/Neutral/Phase/Neg. Seq. Voltage Transformer Fuse Failure Under/Overfrequency Lockout Functionality Settings Groups Non-volatile latches Programmable Elements Programmable Logic FlexElements Digital Inputs Contact Outputs (Fixed) Contact Outputs (Programmable) Virtual Inputs/Outputs Direct Inputs/Outputs VFD/LCD Display Numerical Keypad Trip/Close Coil Supervision Breaker Control User-Programmable LEDs User-Programmable Self Test Selector Switch Digital Counters Digital Elements IRIG-B Input Analog Inputs/Outputs RTD Inputs Power Factor Load Profile Monitoring Current RMS Current Phasor Current Demand Current - Unbalance Current - Ground Leakage Voltage RMS Voltage Phasor Power - Apparent, Real, Reactive MW, MVA, Mvar Demand Breaker Halth Monitoring Energy Frequency Temperature Fault Report/Trip Data User Programmable Trip Reports Event Recorder - Number of Events Oscillography - Cycles @ Sampling Rate Trip Counters Data Logger Test Mode with auxiliary contacts RS232 Port RS485 Port RS422 Port Ethernet Port Fiber Optic Port ModBus Protocol ModBus User Map DNP3 Protocol EGD Protocol Peer-to-peer communication (GOOSE) IEC 61850 Protocol Simple Network Time Protocol TCP/IP

DEVICE
87 50/87

745
3

T35
6

T60
4

16/1 87N 24 27 50G/N/P/Q 50SG 51G/N/P/Q 51SG 50BF 59 59N 67G/NP/Q VTFF 81U/O 86 Optional G/N/P G/N/P

32/1

32/1

PROTECTION

G/N/P P G/N/Q

8 3 3

80 64 32/64 32 Trip/Close

80 64 32/64 32 Trip/Close

CONTROL

Trip

12

Optional

Optional

MONITORING & METERING

40 64 @ 12

1024 93.5 @ 16

1024 93.5 @ 16

COMMUNICATIONS

Optional Optional Optional

Optional Optional Optional

* For the most current comparison list, access us online at: www.GEMultilin.com/selector/transformer.pdf

64