1. 3f0& phase threshold test (distance min operating zero seq. current) -Distance function ON e 2 -Set both 3108 phase threshold (add 1202,1203A resp) eg -Assign relay general p/u function (add 0501) to BO1 Lot or yb ECM Uy -Assign LED's for test purpose if needed as follow 3672 Distance p/u L1, 3673 Distance p/u L2 3674 Distance p/u L3 3675 Distance p/u LE -Freja Current Auto test is needed. a dd YeHS 1204 Jloat wo > Configure |> p/u setting, Hysterises limits, ramp start and stop limits to be able to Catch Wo value, di/dt according the degree of precision needed. > Tick on the faults type you need to test, from Print Preview record results -Care if 3l0& phase threshold doesn't have the same setting, you should adjust !> and ramp 1- 3Uo test (distance min operating zero seq. voltage) Distance function ON -Set 3Uo(add 1204A) -Set 3108 phase threshold (add 1202, 1203A) as 3io setting should be more than phase threshold -Assign relay general p/u function (add 0501) to BO1 ST -Assign LED's for test purpose if needed as pervious test Distance F.D. (Z5) time should be “a” or a reasonable value to cover p/u & d/o test time duration tip -Freja General Auto test is needed. ? Inject 19 current with a value in between phase & 3lo threshold value to create residual current > Same phase volt to create residual voltage 2 With normal type ramp increase voltage up till p/u > With delay type ramp decrease voltage down till d/o ~Care about setting of function (1209A) which switches between 3l0& 3Uo to be Sort if exist 2- Fuse Failure Monitoring test. -Measurement function ON (add 2900) -FFM function ON (add 2901) -Assign (V.T. fuse fail Inst. alarm function (add 0170) to BO1 -Assign LED's for test purpose if needed as pervious test -, v : -There are 2 function to be tested under FFM test vas at ® a-Non Symmetric measurements functions, related addresses (2911A, 2912A) b-3g voltage collapse functions, related addresses (2913A, 2914A) AP quae Ey ea 3.a- Non Symmetric function Freja General Auto test is needed. > Inject 3g healthy current with a value above (add 2912 value) to fulfill current condition. > Inject 39 healthy voltage with rated value > With normal type ramp decrease phase A voltage value till p/u > Subtract the result voltage value from rated volt to get the p/u value > With same technique we can test current p/u by injecting phase A volt below setting And increase phase A current till pfu, same for W/o in both test using delayed ramp -Care that the other 2 phases must be always healthy value and phasing. _-3.b- 3 @ voltage collapse function . -Freja General Auto Sequence test is needed. >1" page healthy 39 current above setting of (add2914A) 1" page healthy 39 voltage (rated value recommended) 2" page healthy 3g current above setting of (add2914A) 32" page healthy 3¢ voltage 0.1V above setting of voltage collapse level (add 2913A) > First Inject Seq. injection with both pages time around 100 ms, function will not futfilled > Inject Seq. injection with both pages time around 100 ms, but 39 voltage of 2” page <(add 2913A) The function fulfilled give alarm -Care that during that test all 3p voltage and current has the same value 3- SOTF test Distance function ON -SOTF function ON (add 0124) -Set HS O/C value (add 2402) -Increase the seal in time to a reasonable value enough to execute the test (add1150A) Assign BI for the M.C. manual close command (add 0356) -Assign BO to function High speed O/C trip command (add 4295) ~-Assign LED's for test purpose if needed as follow 4281 50 HS SOTF plu L1 4282 50 HS SOTF plu L2 4283 50 HS SOTF plu L3 4284 50 HS SOTF piu LE -There are 2 function to be tested under SOTF test a@-HS OIC functions, related addresses (2402) b-SOTF with Z1B or F.D. plu related addresses (1232) 4.a-HS SOTF O/C > With normal type ramp increase 1@ current phase A til pfu > For time measurements inject 1.5 the setting value, get the trip time result 4.b- With Z1B or FD. (25) a eee we me ew ceerrnce been ete aD eee > Assign the Relay general trip function (add 3813) to BO1 > One time injection within Z1B reach without B.C. input we wil got Z1b trip time > Second time injection within Z1B reach with B.C. input we will get inst. trip time > With P/U in. (Z5), increase the time of Z5 to differentiate between Z5 tip & trip via SOTF in. > Assign the Relay general trip function (add 3813) to BO1 > One time injection within Z5 reach without B.C. input we will get Z5 trip time > Second time injection within Z5 reach with B.C. input we will get Inst. trip time ~Care that during that test the seal in fime is the fime within it the SOTF function with B.C. ts valued.

You might also like