Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

RMS AUTOMATION SYSTEMS LTD.

LIGHTING CONTROL ENERGY CONSERVATION SOLUTIONS.

RMS Automation/2010-02-26/AB/Lighting Control System.pdf

LIGHTING CONTROL & ENERGY CONSERVATION SOLUTIONS


Street

Lighting Lighting (High Mast)

Public Area Industrial

Lighting & Hospital Building Installations

Commercial Car

Park Areas Lighting


2

Domestic

RMS Automation/2010-02-26/AB/Lighting Control System.pdf

ENERGY SAVINGS WITH VARIOUS LAMPS


Fluorescent

Ballasts

Lamps with Cu or Al
Reduces Electrical Energy 12% to 42%

C.F.L. Sodium

Lamps

and Mercury Vapor

Metal LED

Halide Lamps

Lamps
3

RMS Automation/2010-02-26/AB/Lighting Control System.pdf

VARIOUS METHODS FOR ENERGY CONSERVATION

Voltage

Control & Timing Control Switching

Selective Area Phase

Cut-Off Control

RMS Automation/2010-02-26/AB/Lighting Control System.pdf

FEATURES TO SUIT YOUR REQUIREMENTS

Saves upto 42% energy with specic conditions. Typical Energy Saving value 20%-32% Schedule Control - Multiple Schedule Allotment (Indoor) Programmable Sunset/Sunrise Time Control (Street Light) Automatic Switching to full intensity for Assured turn-on of Fluorescent lamps.
5

Data Logging within the Unit Remote Access Control through Wireless GSM or Wired RS-232/485 Smooth (Step-less) or Stepped control with Blink-free Switchovers. Complete Display of all Parameters like Voltage, Current, Power and Energy

RMS Automation/2010-02-26/AB/Lighting Control System.pdf

SPECIFICATIONS

Suitable for 3-phase and 1-phase supply applications Supply voltage + 15% Variations Supply 415V -3 phase or 240V-1 phase AC - 50 Hz Energy Saving - 10% to 40% (Depending upto lamps used) Efciency improvement of lamps by 5% to 20% Enclosure class - From IP-32 to IP-54 (IP-56 with only Sp. needs) Measurement Accuracy class 1 as per IEC 62053 part 21/22 Measurement Sensitivity for current - upto 0.8% of rated current
6

Time Accuracy - 1min in 1 year PF Regulation with + 0.98 Operating temp: 0 - 50C Storage temp: -10 - 75C Relative Humidity: 0% to 97% RH Max Altitude - 1,500 meters Max temp rise: +15C MS-Windows Compatible Software for GSM Communication, Data Downloading and Viewing MS- Windows Compatible Software for Adjusting Sunset/Sunrise timing

RMS Automation/2010-02-26/AB/Lighting Control System.pdf

VARIOUS METHODS FOR ENERGY CONSERVATION IN LAMPS


Voltage
240V 220V 200V

Voltage
240V 220V 200V

Lamp Knee Voltage


100V 100V

50Hz.

Cut off level

300W Turn on level 380W

300W

380W

Selective Area

and Timing Control Switching


7

500W

Phase

Cut-Off Control

RMS Automation/2010-02-26/AB/Lighting Control System.pdf

500W

Wattage

Wattage

VARIOUS MODELS
Single

Phase Models for Small Ofce, Shops, Banks and Domestic Applications. Available with Rating from 1kVA to 15kVA Phase Models for Indoor applications like Industries, Commercial Buildings, Hospital, Car Park Areas, Part/ Exhibition Halls, Indoor Sport Stadium. Available with Rating from 3kVA to 63 kVA (+ higher rating with custom built) Phase Models for Street Light Applications. Available with Rating from 3kVA to 63 kVA (+ higher rating with custom built)
8

Three

Three

VARIOUS MODELS
All

Models are further divided into 2 categories

Electro-Mechanical Switching Type


Phase Input

Neutral

Phase Output

Servo Control Type


Phase Input Servo Motor Phase Output

Neutral

RMS Automation/2010-02-26/AB/Lighting Control System.pdf

COMPLETE SCADA CONNECTIVITY THROUGH MODBUS/GSM


Sub-division 1 Sub-division 2
SLC 1 SLC 2 SLC 250 SLC 1 SLC 2 SLC 250

MODBUS MODBUS or GSM Modem connectivity GSM Modem

PSTN Modem / Other Devices


REGIONAL GSMSMS SERVER

PSTN Modem / Other Devices


REGIONAL GSMSMS SERVER

Periodic Bulk File Transfer Using Telephone Lines etc. PSTN Modem / Other Devices
CENTRAL DATABASE SQL SERVER

RMS Automation/2010-02-26/AB/Lighting Control System.pdf

10

MASTER PC TYPICAL SCREEN

RMS Automation/2010-02-26/AB/Lighting Control System.pdf

11

MASTER PC TYPICAL SCREEN

RMS Automation/2010-02-26/AB/Lighting Control System.pdf

12

MASTER PC TYPICAL SCREEN

RMS Automation/2010-02-26/AB/Lighting Control System.pdf

13

MASTER PC TYPICAL SCREEN

RMS Automation/2010-02-26/AB/Lighting Control System.pdf

14

CONTACT US
RMS Automation Systems Ltd. C-138 Naraina Industrial Area, Phase - I New Delhi - 110028 info@rmsautomation.com www.rmsautomation.com Phone: +91 - 11 - 25891072 Fax: +91 - 11 - 45401782

RMS Automation/2010-02-26/AB/Lighting Control System.pdf

15

Thank You
RMS Automation/2010-02-26/AB/Lighting Control System.pdf

16

You might also like