Postal Civil Division AMBALA

TENDER

DOCUMENT
FOR

THE WORK OF

Construction of Post office building at Palam Vihar, Gurgaon.(Haryana)

Certified that this tender document contains pages from 01 (One) to 50(Fifty ) and no page is missing or torn.

Executive Engineer Postal Civil Division Ambala

NAME OF TENDERER :

NAME OF WORK

: Construction of Post office building at Palam Vihar, Gurgaon.(Haryana).

INDEX
SL. NO. 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 15) 16) Cover Page Index Important instructions to the tenderers who have downloaded the tender document from the website Declaration Press Notice Inviting tender Notice Inviting tender CPWD -6 CPWD -8 (Abridged form) Proforma of schedules Correction slip No.1 Special Conditions for Aluminium Works Guarantee to be executed by contractors for removal of defects after completion in respect of water proofing works Additional conditions, additional specifications & important notes Special conditions for ISI marked items Schedule-D Special Conditions/Specific requirements for the work Schedule of quantity PAGES DETAILS FROM 1 2 3 4 5 6 7 10 12 16 17 18 19 25 26 27 TO 1 2 3 4 5 6 9 11 15 16 17 18 24 25 26 50

Certified that this N.I.T. contains pages from 01 (One) to 50(Fifty ) and no page is missing or torn.

Executive Engineer Postal Civil Division Ambala

IMPORTANT INSTRUCTIONS TO TENDERERS WHO HAVE DOWNLOADED THE TENDER DOCUMENT FROM WEB
The tenderers who have down loaded the tenders from the web, should read the following important instructions carefully before actually quoting the rates & submitting the tender documents: 1. The tenderer should see carefully & ensure that the complete tender documents including schedule of quantities has been down loaded & there are 50(Fifty ) Pages in all in the tender document. 2. The printout of tender documents should be taken on 12 (A4) paper only. 3. The tenderer should ensure that no page in the down loaded tender document is missing. 4. The tenderer should ensure that all pages in the down loaded tender document are legible & clear & are printed on a good quality paper. 5. The tenderer should ensure that every page of the downloaded tender document is signed by tenderer with stamp (seal). 6. On page 2,3,4,10,16,17,18,19,25,26,27 & 50 of the down loaded tender document, the name of the tenderer should be filled by the tenderer. 7. The tenderer should ensure that the down loaded tender document is properly bound and sealed before submitting the same. 8. The loose / spiral bound tenders not properly sealed shall be rejected out-rightly. 9. In case of any correction/addition/alteration/omission in the tender documents, it shall be treated as non- responsive and shall be rejected. 10. The tenderer shall furnish a declaration to this effect that no addition/ deletion/corrections have been made in the tender documents submitted and it is identical to the tender document appearing on Web site. 11. The tenderer should read carefully & sign the declaration given on the next page before submitting the tender. 12. The cost of tender should be submitted along with the EMD as detailed in NIT. 13. In case of any doubt in the down loaded tender, the same should be got clarified from the O/o Executive Engineer (C), Postal Civil Division, Ambala before submitting the tender.

CONTRACTOR

Executive Engineer(C)

DECLARATION
( TO BE GIVEN BY THE TENDERERS WHO HAVE DOWNLOADED THE TENDER DOCUMENT FROM THE WEB )

It is to certify that : 1) I / we have submitted the tenders in the Performa as downloaded directly from the website. 2) I/ We have submitted tender documents which are same / identical as available in the website. 3) I / we have not made any modification / corrections / additions etc in the tender documents downloaded from web by me / us. 4) I / We have checked that no page is missing and all pages as per the index are available & that All pages of tender document submitted by us are clear & legible. 5) I / we have signed (with stamp) all the pages of the tender documents before submitting the same. 6) I / we have sealed the tender documents properly before submitting the same. 7) I / We have submitted the cost of tender along with the EMD. 8) I have read carefully & understood the important instructions to the all tenderers & to tenderers who have down loaded the tenders from the web. 9) In case at any stage later, it is found there is difference in our downloaded tender documents from the original, Department shall have the absolute right to take any action as deemed fit without any prior intimation to me / us. 10) In case at any stage later, it is found that there is difference in our downloaded tender documents from the original, the tender / work will be cancelled and Earnest Money/ Security Deposit will be forfeited at any stage whenever it is so noticed. The department will not pay any damages to me / us on this account. 11) In case at any stage later, it is found that there is difference in our downloaded tender documents from the original, I / We may also be debarred for further participation in the tender in the department & would also render me / us liable to be removed from the approved list of contractors of the Department.

Dated (CONTRACTOR) (SIGN WITH SEAL)

DEPARTMENT OF POSTS (CIVIL WING) PRESS NOTICE INVITING TENDER The Executive Engineer (C), Postal Civil Division Ambala invites on behalf of The President of India, sealed item rate tenders from eligible contractors for the work of Construction of Post office building at Palam Vihar, Gurgaon.(Haryana) for Estimated Cost of `2955357/-, EMD: `59110/- Last date of Application 16-01-12. or For detailed information please log on to http://www.indiapost.gov.in/ http://tenders.gov.in/department.asp?id=832

Executive Engineer(c)

NOTICE INVITING TENDER NIT No 79/EE/PCDA/2011-12 Dated :-06-01-2012 1.0 Item rate tenders are invited on behalf of the President of India from approved and eligible contractors from the approved list of Department of Posts, B.S.N.L., CPWD, MES, Railways, Local State PWD (B&R) and allied Departments of local state PWD (B&R) eligible for tendering in respective State PWD (B&R) for building works for the work of Construction of Post office building at Palam Vihar, Gurgaon.(Haryana). The Central/State Government Undertakings in their own capacity shall also be eligible to tender under usual terms and conditions applicable to them from time to time. 1.1 Tenders will be received up to 3 P.M. on 23-1-12 in the office of i) Assistant Engineer (Civil) Postal Civil Sub Division 103/22 Laxmi Nagar Rohtak ii) Assistant Engineer (Civil),Postal Civil Sub Division 1st floor Post Office Building at Sec-29 Chandigarh a) Estimated cost put to tender ` 2955357/b) Earnest money to be deposited ` 59110/- in the shape of call receipt of a scheduled bank / fixed deposit receipt of a schedule bank / demand draft of a schedule bank issued in favour of Accounts Officer, Postal Civil, Division, Ambala. c) Period of completion allowed 8 (Eight) Months. d) Tenders will be opened at 3.30 p.m. by Executive Engineer (C) or his authorised representative on the same day in the presence of those who want to be present at :- i) Rohtak (Haryana ) in the office Assistant Engineer (Civil) Postal Civil Sub Division 103/22 Laxmi Nagar Rohtak and ii) Chandigarh in the office of Assistant Engineer (Civil).Postal Civil Sub Division 1st floor Post Office Building at Sec-29 Chandigarh. The contractor can drop only one tender for a work that may be at Chandigarh or Rohtak at the address given above. 1.2 All intending tenders, other than those enlisted with Department of Posts while applying for above work should have completed satisfactorily RCC framed structure building works under Central Government/State Government/Public Sector Undertakings / Autonomous body of Central Govt / Local State Govt atleast three similar works each of value not less than 40% of estimated cost or two similar works each of value not less than 50% of estimated cost or one similar work costing not less than 80% of Estimated Cost during the last 7 years ending last day of the month previous to one in which the tenders are invited. 1.3 The contractors shall submit list of completed works of the requisite magnitude along with attested copies of certificates/testimonials of their satisfactory completion from the department concerned obtained from an officer not below the rank of an Executive Engineer in charge of the work while applying for issue of tender forms. The work completed with imposition of levy of compensation for delay shall not be considered as satisfactorily completed work for the purpose of work experience. 2.0 The tender and the earnest money (including cost of tender if downloaded from web) shall be placed in separate sealed envelopes each marked Tender and Earnest Money respectively. Both the envelopes shall be submitted together in another sealed envelope with name of work For down loadable tenders there should be two extra separate envelops marked Eligibility documents and Declaration respectively, addressed to the Executive Engineer (C) Postal Civil Division, Ambala. The Contractors who do not deposit the earnest money in the above manner and also submit the downloadable tender in the manner prescribed will be summarily rejected. 3.0 Lay out plan showing the site of the proposed building and architectural working drawings can be seen in the office of E.E.(C) , Postal Civil Division, Ambala on all working days. 4.0 Conditions and tender forms can be had on application from i) The Assistant Engineer (Civil) Postal Civil Sub Division 103/22 Laxmi Nagar Rohtak ii) The Assistant Engineer (Civil).Postal Civil Sub Division 1st floor Post Office Building at Sec-29 Chandigarh. on payment of the `500/- in cash as cost of tender (non-refundable). Application for tender forms will be received up to 4 p.m. on 16-01-12 and tenders will be sold up to 4 p.m. on 18-01-12. In case of holiday is declared on any of the above noted days, that activity will be automatically shifted to next working day. 5.0 Tenders, in which any of the prescribed conditions is not fulfilled or any condition including that conditional rebate is put forth by the tenderer, shall be summarily rejected. However, the tenders with unconditional rebate will be acceptable. 6.0 The blank tender document with additional conditions and schedule of quantities / other schedule can also be downloaded from Web site www.indiapost.gov.in/ or http://tenders.gov.in/department.asp?id=832. The cost of tender (Non-refundable) may be submitted along with EMD in the same manner as specified in Para 6 above. 7.0 INSTRUCTIONS FOR TENDERER USING DOWNLOADED TENDER DOCUMENTS FROM WEBSITE : (i) The downloaded Tender documents in which rates are quoted should be properly bound and wax sealed. Loose/ spiral bound submission shall be rejected out rightly (in case of any correction / addition / alteration / omissions in the tender documents shall be treated as non responsive and shall be rejected). Every page of downloaded tender shall be signed by the contractor with stamp (seal). The tenderer shall furnish declaration to this effect that no addition /deletion/ correction have been made in the tender documents submitted and it is identical to the tender documents appearing on WEBSITE. (ii) The tenderers shall also submit attested copies of eligibility and experience particulars in a separate sealed envelop superscribing Eligibility Documents in addition to the Tender and EMD as specified in para 2.0 above. The envelope containing eligibility document shall be opened first. The envelope containing Tender and EMD shall only be opened for those tenderers who meet the eligibility criteria as per this NIT. The tender of the Contractor who do not submit the eligibility documents in the above manner will be summarily rejected. (iii) The agreement shall be drawn only on the original tender documents available with the Executive Engineer(C). Original tender documents are available in the Office of Executive Engineer(C), Postal Civil Division, Ambala which can be seen by the intending tenderer before tendering for the work. or 8.0 This notice is also available on website http://www.indiapost.gov.in/ http://tenders.gov.in/department.asp?id=832. Executive Engineer(C) Postal Civil Division Ambala

CPWD 6
GOVERNMENT OF INDIA

DEPARTMENT OF POSTS
NOTICE INVITING TENDER 1.0 Item rate tenders are invited on behalf of the President of India from approved and eligible contractor from the approved list of Department of Posts, BSNL, CPWD, MES, Railways, Local State PWD (B&R) and allied Departments of local state PWD (B&R) eligible for tendering in respective State PWD (B&R) for building works for the Construction of Post office building at Palam Vihar, Gurgaon.(Haryana). The Central/State Government Undertakings in their own capacity shall also be eligible to tender under usual terms and conditions applicable to them from time to time. Tenders will be received up to 3:00 P.M. on 23-1-12 (a) Estimated cost put to tender ` 2955357/(b) Earnest money to be deposited ` 59110/- in the shape of call receipt of a scheduled bank / fixed deposit receipt of a schedule bank / demand draft of a schedule bank issued in favour of Accounts Officer, Postal Civil, Division, Ambala. (c) Period of completion allowed 8 (Eight) Months. Tenders will be opened at 3:30 p.m. on the same day in the presence of those who want to be present at :- i) Rohtak (Haryana ) in the office Assistant Engineer (Civil) Postal Civil Sub Division 103/22 Laxmi Nagar Rohtak and ii) Chandigarh in the office of Assistant Engineer (Civil).Postal Civil Sub Division 1st floor Post Office Building at Sec-29 Chandigarh. The contractor can drop only one tender for a work that may be at Chandigarh or Rohtak at the address given above. 1.2 All intending tenderers, other than those enlisted with Department of Posts while applying for above work should have completed satisfactorily RCC framed structure building works under Central Government/State Government/Public Sector Undertakings / Autonomous body of Central Govt / Local State Govt atleast three similar works each of value not less than 40% of estimated cost or two similar works each of value not less than 50% of estimated cost or one similar work value not less than 80% of estimated cost (rounded to nearest one thousand rupees) in last 7 years ending last day of the month previous to one in which the tenders are invited The contractors shall submit list of completed works of the requisite magnitude along with attested copies of certificates/testimonials of their satisfactory completion from the department concerned obtained from an officer not below the rank of the Executive Engineer in charge of the work while applying for issue of tender forms. The work completed with imposition of levy of compensation for delay shall not be considered as satisfactorily completed work for the purpose of work experience. Agreement shall be drawn with the successful tenderer on prescribed Form No. C.P.W.D. 8 which is available as a Govt. of India Publication. Tenderer shall quote his rates as per various terms and conditions of the said form which will form part of the agreement. The time allowed for carrying out the work will be 8 (Eight) Months from the date of start as defined in schedule F or from the date of handing over of the site, whichever is later, in accordance with the phasing, if any, indicated in the tender documents. The site for the work is available . Lay out plan showing the site of the proposed building and architectural working drawings can be seen in the office of E.E.(C) , Postal Civil Division, Ambala on all working days. Conditions and tender forms can be had on application from i) The Assistant Engineer (Civil) Postal Civil Sub Division 103/22 Laxmi Nagar Rohtak ii) The Assistant Engineer (Civil).Postal Civil Sub Division 1st floor Post Office Building at Sec-29 Chandigarh on payment of the `500 /in cash as cost of tender (Non-refundable). Application for tender forms will be received up to 4 p.m. on 16-01-12 and tenders will be sold up to 4 p.m. on 18-01-12 In case of holiday is declared on any of the above noted days, that activity will be automatically shifted to next working day. Tenders shall be accompanied with Earnest money of ` 59110/- (In cash up to ` 10000/-) /Receipt Treasury Challan/Deposit at call receipt of a scheduled bank/fixed deposit receipt of a scheduled 7

1.1

1.3

4 5

6(i)

bank/demand draft of a scheduled bank issued in favour of A.O., PCD, Ambala 50% of earnest money or ` 20 lacs, whichever is less, will have to be deposited in the shape prescribed above and balance amount of earnest money can be accepted in the form of Bank guarantee issued by a scheduled bank having validity for 6 months or more from the last date of receipt of tenders. 6(ii) The tender and the earnest money (including cost of tender if downloaded from web) shall be placed in separate sealed envelopes, each marked Tender and Earnest Money respectively. In cases where earnest money in cash is acceptable, the same shall be deposited with the Cashier of the Division and the receipt placed in the envelope meant for earnest money. Both the envelopes shall be submitted together in another sealed envelope with the name of work and due date of opening written on envelope, which will be received by the EE(C) or his authorized representative in offices at 1.1 above up to 3.00 P.M. on 23-1-12 and will be opened by him or his authorized representative in offices at 1.1 above on the same day at 3.30 P.M. The envelope marked Tender of only those tenderers shall be opened, whose earnest money (including cost of tender if downloaded from web), placed in the other envelope, is found to be in order. 7 The contractor whose tender is accepted will be required to furnish performance guarantee of 5% (five percent) of the tendered amount within the period specified in Schedule F. This guarantee shall be in the form of cash (in case guarantee amount is less than ` 10000/-) or Deposit at call receipt of any scheduled bank/Bankers cheque of any scheduled bank/Demand Draft of any scheduled bank/pay order of any scheduled bank (in case guarantee amount is less than ` 1,00,000/-) or Govt. Securities or Fixed Deposit Receipts or Guarantee Bonds of any scheduled Bank or the State Bank of India in accordance with the prescribed form. In case the contractor fails to deposit the said performance guarantee within the period as indicated in Schedule F, including the extended period if any, the Earnest Money deposited by the contractor shall be forfeited automatically without any notice to the contractor. The description of the work is as follow : Construction of Post office building at Palam Vihar, Gurgaon.(Haryana) Copies of other drawings and documents pertaining to the works will be open for inspection by the tenderers at the office of the above mentioned officer. Tenderers are advised to inspect and examine the site and its surroundings and satisfy themselves before submitting their tenders as to the nature of the ground and sub-soil (so far as is practicable), the form and nature of the site, the means of access to this site, the accommodation they may require and in general shall themselves obtain all necessary informations as to risks, contingencies and other circumstances which may influence or affect their tender. A tenderer shall be deemed to have full knowledge of the site whether he inspects it or not and no extra charges consequent on any misunderstanding or otherwise shall be allowed. The tenderer shall be responsible for arranging and maintaining at his own cost all materials, tools & plants, water, electricity access, facilities for workers and all other services required for executing the work unless otherwise specifically provided for in the contract documents. Submission of a tender by a tenderer implies that he has read this notice and all other contract documents and has made himself aware of the scope and specifications of the work to be done and of conditions and rates at which stores, tools and plant, etc. will be issued to him by the Government and local conditions and other factors having a bearing on the execution of the work. 9 The competent authority on behalf of the President of India does not bind itself to accept the lowest or any other tender and reserves to itself the authority to reject any or all the tenders received without the assignment of any reason. All tenders in which any of the prescribed condition is not fulfilled or any condition including that of conditional rebate is put forth by the tenderer shall be summarily rejected. Canvassing whether directly or indirectly, in connection in with tenders is strictly prohibited and the tenders submitted by the contractors who resort to canvassing will be liable to rejection. The competent authority on behalf of President of India reserves to himself the right of accepting the whole or any part of the tender and the tenderer shall be bound to perform the same at the rate quoted. The contractor shall not be permitted to tender for works in the Postal Civil Circle (Division in case of contractors of Horticulture/Nursery category) responsible for award and execution of contracts in which his near relative is posted as Divisional Accountant or as an officer in any capacity between the grades of Superintending Engineer and Junior Engineer (both inclusive). He shall also intimate the names of persons who are working with him in any capacity or are 8

10

11

12

subsequently employed by him and who are near relatives to any gazetted officer in the Department of Posts or in the Ministry of Communications & IT. Any breach of this condition by the contractor would render him liable to be removed from the approved list of contractors of this Department. 13 No Engineer of gazetted rank or other Gazetted officer employed in Engineering or Administrative duties in an Engineering Department of the Government of India is allowed to work as a contractor for a period of one year after his retirement from Government service, without the previous permission of the Government of India in writing. This contract is liable to be cancelled if either the contractor or any of his employees is found any time to be such a person who had not obtained the permission of the Government of India as aforesaid before submission of the tender or engagement in the contractors service. The tender for the works shall remain open for acceptance for a period of 90 (ninety) days from the date of opening of tender. If any tenderer withdraws his tender before the said period or issue of letter of acceptance, whichever is earlier, or makes any modifications in the terms and conditions of the tender which are not acceptable to the department, then the Government shall, without prejudice to any other right or remedy, be at liberty to forfeit 50% of the said earnest money as aforesaid. Further the tenderer shall not be allowed to participate in the re-tendering process of the work. This Notice Inviting Tender shall form a part of the contract document. The successful tenderer/contractor, on acceptance of his tender by the Accepting Authority, shall, within 15 days from the stipulated date of start of the work, sign the contract consisting of:(a) The notice inviting tender, all the documents including additional conditions, specifications and drawings, if any, forming the tender as issued at the time of invitation of tender and acceptance thereof together with any correspondence leading thereto. (b) Standard C.P.W.D. Form 8. 16 The blank tender document with additional conditions and schedule of quantities / other schedule can also be downloaded from Web site www.indiapost.gov.in. or http://tenders.gov.in/department.asp?id=832. The cost of tender (Non-refundable) shall be submitted along with EMD in the same manner as specified in para 6 above. INSTRUCTIONS FOR TENDERER USING DOWNLOADED TENDER DOCUMENTS FROM WEBSITE : (i) The downloaded Tender documents should be properly bound and wax sealed. Loose/ spiral bound submission shall be rejected out rightly (in case of any correction / addition / alteration / omissions in the tender documents shall be treated as non responsive and shall be rejected). Every page of downloaded tender shall be signed by the contractor. (ii) The tenderers shall also submit attested copies of eligibility and experience particulars in a separate sealed envelop superscribing Eligibility Documents in addition to the Tender and EMD as specified in para 6(i) above. The envelope containing eligibility document shall be opened first. The envelope containing Tender and EMD shall only be opened for those tenderers who meet the eligibility criteria as per this NIT. The envelopes containing Tender & EMD of the Contractor who do not submit the eligibility documents in the above manner shall not be opened. 18 Tenders, in which any of the prescribed conditions is not fulfilled or any condition including that conditional rebate is put forth by the tenderer, shall be summarily rejected. However, the tenders with unconditional rebates will be acceptable. on website http://www.indiapost.gov.in/ or

14

15

17

This notice is also available http://tenders.gov.in/department.asp?id=832.

Executive Engineer(C) Postal Civil Division Ambala

CPWD- 8
GOVERNMENT OF INDIA

DEPARTMENT OF POSTS
STATE: Haryana BRANCH: Civil Wing ZONE : North CIRCLE: Ambala DIVISION: PCD, Ambala SUB DN: PCSD, Rohtak

ITEM RATE TENDER & CONTRACT FOR WORKS Tender for the work of:- Construction of Post office building at Palam Vihar, Gurgaon.(Haryana).
i) To be submitted by 15:00 hrs on 23-1-12 at :- a) Rohtak (Haryana ) in the office Assistant Engineer (Civil) Postal Civil Sub Division 103/22 Laxmi Nagar Rohtak and b) Chandigarh in the office of Assistant Engineer (Civil).Postal Civil Sub Division 1st floor Post Office Building at Sec-29 Chandigarh. To be opened in Presence of tenderers who may be present at 15:30 hrs on 231-12 in the office of i) The Assistant Engineer (Civil) Postal Civil Sub Division 103/22 Laxmi Nagar Rohtak ii) The Assistant Engineer (Civil).Postal Civil Sub Division 1st floor Post Office Building at Sec-29 Chandigarh.

ii)

Issued to:- _________________________________ (Contractor) Date of issue:- ________________________ Executive Engineer (C) Postal Civil Division Ambala

TENDER
I/We have read and examined the notice inviting tender, schedule, A,B,C,D,E & F, Specifications applicable, Drawings & Designs, General Rules and Directions, Conditions of Contract, Clauses of contract, Special conditions, Schedule of Rate & other documents and Rules referred to in the conditions of contract and all other contents in the tender document for the work. I/We hereby tender for the execution of the work specified for the President of India within the time specified in Schedule F, Viz., schedule of quantities and in accordance in all respects with the specifications, designs, drawings and instructions in writing referred to in Rule-1 of General Rules and Directions and in Clause 11 of the Conditions of contract and with such materials as are provided for, by, and in respects in accordance with, such conditions so far as applicable. We agree to keep the tender open for ninety (90) days from the due date of submission thereof and not to make any modifications in its terms and conditions. A sum of ` 59110/- is hereby forwarded in Deposit at call receipt of a Scheduled Bank/fixed deposit receipt of Scheduled Bank/Demand Draft of a scheduled Bank as earnest money, If I/we, fail to furnish the prescribed performance guarantee within prescribed period, I/we agree that the said President of India or his successors in office shall without prejudice to any other right or remedy, be at liberty to forfeit the said earnest money absolutely. Further, if I/We fail to commence work as specified, I/We agree that President of India or his successors in office shall without prejudice to any other right or remedy available in law, be at liberty to forfeit the said earnest money and the performance guarantee absolutely, otherwise the said earnest money shall be retained by him towards security deposit to execute all the works referred to in the tender documents upon the terms and conditions contained or referred to therein and to carry out such deviations as may be ordered, up to maximum of the percentage mentioned in Schedule F and those in excess of that limit at the rates to be determined in accordance with the provision contained in Clause 12.2 and 12.3 of the tender form. Further, I/We agree that in case of forfeiture of Earnest money or both Earnest money and performance guarantee as afore said, I/We shall be debarred for participation in the re-tendering process of the work. 10

I/We hereby declare that I/we shall treat the tender documents drawings and other records connected with the work as secret/confidential documents and shall not communicate information/derived therefrom to any person other than a person to whom I/we am/are authorized to communicate the same or use the information in any manner prejudicial to the safety of the State. Dated.. Signatures of Contractor Postal Address

Witness: Address: Occupation:

ACCEPTANCE
The above tender (as modified by you as provided in the letters mentioned hereunder) is accepted by me for and on behalf of the President of India for a sum of `____________ (` _____ ________ __________ _______ ______________ _________ ______________ _________________) The letters referred to below shall form part of this contract Agreement:i) ii) iii)

Signatures. Designation. Dated.. For & on behalf of the President of India

11

SCHEDULES
SCHEDULE A SCHEDULE B Schedule of materials to be issued to the contractor. S.No. Description of item Quantity Rates in figures & words at which the material will be charged to the contractor 4. Schedule B deleted SCHEDULE C Tools and plants to be hired to the contractor S.No. 1. Description 2. Hire charges per day 3. Schedule C deleted SCHEDULE DExtra schedule for specified requirements/documents for the work, if any. Additional conditions / specification, Important notes SCHEDULE E Reference to General Conditions of contract. Place of issue 4. Place of issue Schedule of Quantities (Enclosed)

1.

2.

3.

5.

NAME OF WORK

Construction of Post office building at Palam Vihar, Gurgaon.(Haryana).

Estimated cost of Work:i) ii) iii) Earnest Money:Performance GuaranteeSecurity Deposit

` 2955357/` 59110/5% of tendered Value 5% of tendered Value

SCHEDULE F General Rules & Directions:Officer Inviting tender:Executive Engineer(c), Postal Civil Division-, Ambala (Haryana). Maximum percentage for quantity of items of work to be executed beyond which rates are to be determined in accordance with Clauses 12.2. & 12.3 See below Definitions: i) ii) iii) Engineer-in-Charge: Accepting Authority: Percentage on cost of materials Executive Engineer(c), Postal Civil Division, Ambala Superintending Engineer(C), Postal Civil Circle Ambala. 15% 12

and labour to cover all overheads and profits.

iv) v) vi) Clause 1 i)

Standard Schedule of Rates: Department: Standard CPWD contract Form

DSR-2007 Department of Posts CPWD form 8 as modified & corrected up to date correction slips and General conditions.

Time allowed for submission of Performance Guarantee from the date of issue of letter of acceptance, in days. Maximum allowable extension beyond the period provided in (i) above in days.

15 days

ii)

15 days

Clause 2 Authority for fixing compensation under clause 2. Clause 2A Whether Clause 2A shall be applicable: Clause 5 Number of days from the date of issue of letter of acceptance for reckoning date of start. S.No. Financial progress 1. 2. 3. 4. 1/8th (of whole work) 3/8th (of whole work) 3/4th (of whole work) Full Time allowed (From date of start) 1/4th (of whole time) 1/2 (of whole time) 3/4th (of whole time) Full No S.E(C), PCC, Ambala

15 Days Amount to be with-held In the event of not achieving the necessary progress, from the running payments 1% of tendered value of work will be withheld for failure of each mile stone. 8 months

Time allowed for execution of work: Clause 6, 6A Clause applicable :- (6 or 6A) Clause 7 Gross work to be done together with net payment/adjustment of advances for material collected, if any, since the last such Payment for being eligible to interim payment. Clause 10A

Clause 6

` 5.5 lac

List of testing equipments to be provided by the contractor at site lab. 1. Cube moulds. 2.Jar for silt cement testing. 3. Set of sieves. 4 Weighing Balance. 5. Slump Cone. Clause 10B(i) Whether Clause 10 B (ii) shall be applicable Clause 10C Component of labour expressed as percent of value of work = 25 %. Clause 10CC Not applicable 13 No

Clause 10CA Materials Covered under this clause Nearest materials (other than cement, reinforcement bars and structural steel) for which All India Wholesale Price Index to be followed: Nil Base Price of all the Materials covered under Clause 10 CA

(A) Cement(OPC) Reinforcement Bars TMT-500 (B) Primry Manufacturer (C) Secondary Manufacturer (d) Structural Steel

(A) (B) (C) (D)

` ` ` `

5400/47500/43600/45498

Clause 11 Specifications to be followed for execution of work:Clause 12 12.2 & 12.3

CPWD specifications 2007 With upto date Correction Slips 30%

Deviation Limit beyond which clauses 12.2. & 12.3 shall apply for building Work. Deviation Limit beyond which clauses 12.2 & 12.3 shall apply for foundation Work.

12.5

100%

Clause 16 Competent Authority for deciding reduced rates:Clause 36 i)

S.E(C), PCC, Ambala

Requirement of Technical Representative(s) and recovery Rate Minimum Number Rate at which recovery Minimum Discipline Designation Experience shall be made from the (Principal Qualification of contractor in the event Technical/ Technical Technical of not fulfilling provision Representative of clause 36(i) representative) Figures Words 1. Graduate Civil Principal 5 years 01 ` 15000/- ` Fifteen Engineer Technical thousand Representative only per month. Assistant Engineers retired from Government Services that are holding Diploma in Civil Engineering will be treated at par with Graduate Engineer. S.No. Clause 42 i) Schedule/statement for determining theoretical quantity of cement & bitumen on the basis of Delhi Schedule of Rates 2007 printed by C.P.W.D. Variation permissible on theoretical quantities: Cement for works with estimated cost put to to tender more than 5 lakhs Bitumen for all works Steel Reinforcement and Structural steel sections for each diameter, section and category All other materials

ii) a)

2% Plus /minus

b) c)

2.5% plus only & nil on minus side 2% plus/minus

d)

NIL

14

Price to be considered for recovery. Recovery rate for quantities beyond permissible variation. Rate in figures and words at which recovery shall and made from the contractor Sl. No. Description of item Excess use beyond Less use beyond permissible the permissible variation variation 1 Cement 2 Steel Reinforcement 3 Structural Sections 4 Bitumen issued free 5 Bitumen issued at stipulated fixed price.

15

CORRECTION SLIP NO.1


(Correction to Form CPWD-6 & 7/8 (2010) (For use in Department of Posts: India) CORRECTION TO:- Definition under CONDITIONS OF CONTRACT all reference to:i) Director General of Works, CPWD, ii) CPWD/Public Works Department, iii) Administrative Head of CPWD, iv) Chief Engineer, CPWD v) CPWD Circle & vi) Ministry of Urban Development In various clauses shall be taken to mean:i) ii) iii) iv) v) vi) Chief Engineer(c), Department of Posts, Department of Posts/Civil Wing, Administrative Head of Department of Posts Chief Engineer(c), Department of Posts Postal Civil Circle/Zone & Ministry of Communications & IT, Department of Posts

EXCEPT IN:- In the following places and clauses where no modifications are intended:i) ii) CPWD safety code, Clause 1,1A,2,3,4,5,6,7,8,8A,9,9A,10,10A,10B(i),10C,10CA,10D,11,12,13,14,15,16,17,18,18A,18 B,19,19A,19B,19C,19D,19E,19F,19i,19J,19K,20,21,22,23,24,25,26,27,28,29,29B,30,31,3 1A,32,33,35,36,37,38,39,40,41,42,43,44,45 Model rules for protection of health and Sanitary arrangement for workers employed by CPWD or its contractors (Heading only) Central Public Works Department Contractors Labour Regulations (In Heading and Regulations No.1 only), CPWD- Delhi Schedule of Rates and Specifications

iii) iv) v)

Contractor

Engineer-in-Charge

16

SPECIAL CONDITIONS FOR ALUMINIUM WORKS


(For Doors, Windows, Ventilators and Partitions)

1. Extruded aluminium sections of JINDAL, INDAL or Equivalent as approved by the Engineer-in-Charge shall only be used. The various aluminium sections of JINDAL make generally used in doors, windows, ventilators, partitions etc, are indicated in the table attached. The sections of other size, shape and thickness may also be used is approved by the Engineerin-Charge. Various tests of aluminium sections shall be conducted in accordance with relevant provisions of IS:1868, IS:5523 & IS:5528. 2. Aluminium doors, windows, ventilators and partitions shall be fabricated generally as per the approved (architect) drawings. Alternatively, the contractor shall submit the drawings indicating the proposed sections to be used by him and the fixing arrangements, for approval. The Engineer-in-Charge shall have the right to reject or modify these drawings before approval and the contractor is bound to execute the work in accordance with drawings approved by the Engineer-in-Charge. 3. Samples of doors, windows, ventilators and partitions as per approved drawings, shall be fabricated and got approved from the Engineer-in-Charge before taking up the execution of these items. 4. Aluminium sections shall be jointed to each other, wherever required, with extruded aluminium angle cleats of suitable size and of thickness not less than 6mm in frames of doors/windows/ventilators/partitions & door shutters and not less than 4mm in window shutters, with stainless steel screws. All joints, unless specified, shall be mitred. 5. Fabricated aluminium frames shall be given a lacquer coating, which shall be maintained during the entire period of construction to prevent any damage to the anodic (Powder) coating to aluminium sections. The surface shall be cleaned and polished before handing over the works. Nothing extra shall be paid on this account. 6. Sliding-Shutters in partly openable windows, shall be provided with heavy-duty nylon rollers with concealed bearings and aluminium stoppers and special locking arrangements as approved by the Engineer-in-Charge. The interlocking styles of sliding shutters shall be provided with PVC weather sealing gasket. To drain off rain water collected in between channels, cuts of 15mm width shall be provided at both ends of the bottom track as directed by the Engineer-inCharge. Side-Hung-Shutters in fully openable windows, shall be provided with best quality heavyduty type anodic (Powder) coated aluminium hinges with stainless steel pins/bolts, anodized (Powder) coated aluminium peg stays and fasteners of suitable size and shape. 7. RATES:- Actual weight of extruded aluminium sections, angle cleats and snap beadings, excluding the weight of all fittings and fixtures, shall be measured for payment. The cost of all fittings and fixtures (i.e. stainless steel screws, nylon rollers, locking arrangements, gasket, making cuts, hinges, pins/bolts, peg stays, fastners) and the wastage of extruded aluminium sections, shall be deemed to be included in the agreement rate and noting extra whatsoever shall be payable. Panelling and glazing shall be paid separately.

Contractor

Engineer-in-Charge

17

GUARANTEE TO BE EXECUTED BY CONTRACTORS FOR REMOVAL OF DEFECTS AFTER COMPLETION IN RESPECT OF WATER PROOFING WORKS
(Refer Original and Main Agreement NoDated..) The Agreement made this . Day of . Two thousand and . between .. son of of . (hereinafter called the Guarantor of the one part) and the PRESIDENT OF INDIA (hereinafter called Government of the other part). WHEREAS this agreement in supplementary to a contract (hereinafter called the Contract), dated /../.. and made between the GUARANTOR of the one part and the Government of the other part, whereby the contractor, inter alia, undertook to render the buildings and structures in the said contract recited completely water and leak-proof. AND WHEREAS GUARANTOR agreed to give a guarantee to the effect that the said structures will remain water and leak-proof for five years from the date of giving of water proofing treatment. NOW THE GUARANTOR hereby guarantees that water-proofing treatment given by him will render the structures completely leak-proof and the minimum life of such water proofing treatment shall be five years to be reckoned from the date after the maintenance period prescribed in the Contract. Provided that the guarantor will not be responsible for leakage caused by earth quake or structural defects or misuse of roof or alteration and for such purpose: a) Misuse of roof shall mean any operation which will damage proofing treatment, like chopping of fire wood and things of the same nature which might cause damage to roof; b) Alteration shall mean construction of an additional storey or a part of the roof or construction adjoining to existing roof whereby proofing treatment is removed in parts; c) The decision of the Engineer-in-Charge with regard to cause of leakage shall be final.

During this period of guarantee, the guarantor shall make good or defects and in case of any defect being found, render the building water proof to the satisfaction of the Engineer-in-Charge at his cost and shall commence the work for such rectification within seven days from the date of issue of notice from the Engineer-in-Charge calling upon him to rectify the defects, failing which the work shall be got done by the Department by some other contractor at the GUARANTORS cost and risk. The decision of Engineer-in-Charge as to the cost, payable by the guarantor shall be final and binding. That if GUARANTOR fails to execute the water-proofing or commits breach there under then the guarantor will indemnify the principle and his successors against all loss, damage, cost, expense or otherwise which may be incurred by him by reason of any default on the part of the GUARANTOR in performance and observance of this supplementary agreement. As to the amount of loss and /or damage and/or cost incurred by the Government, the decision of the Engineer-in-Charge will be final and binding on the parties. IN WITNESS WHEREOF these presents have been executed by the obligor and by . and for and on behalf of the PRESIDENT OF INDIA on the day, month and year first above written. Signed, sealed and delivered by OBLIGOR in the presence of : 1., 2. Signed for and on behalf of THE PRESIDENT OF INDIA by in the presence of : 1 , 2.

Contractor Refer appendix-25 of CPWD Works Manual 2007)

Engineer-in-Charge

18

ADDITIONAL CONDTIONS, ADDITIONAL SPECIFICATIONS & IMPOTANT NOTES


A 1. 2. ADDITIONAL CONDITIONS The contractor shall at his own expense, provide all materials, required for work. The Contractor shall maintain safe custody of materials brought to the site. The contractor shall also employ necessary watch and ward establishment for the work and other purposes as required at his own cost. For Cement and Steel and other materials, as prescribed, the quantities brought at site shall be entered in the respective material at site accounts and shall be treated as issued for maintenance of daily consumption. The procurement of cement and Reinforcement Steel and their issue and consumption shall be governed as per conditions laid down hereunder. CEMENT The contractor shall procure 43 grade (Conforming to I.S: 8112) Ordinary Portland Cement, as required in the work, from reputed manufactures of cement, having a production-capacity of one million tonnes per annum or more. Such as A.C.C. L&T, Vikmam, Shri Cement and Cement Corporation of India etc. as approved by Ministry of Industry, Government of India, and holding license to use ISI Certification mark for their product. Supply of cement shall be taken in 50 kg bags bearing manufacturers name and ISI marking. Samples of cement arranged by the contractor shall be taken by the Engineer-in-charge and got tested in accordance with provisions of the relevant BIS Codes. In case test results indicate that the cement arranged by the contractor does not conform to the relevant BIS Codes, the same shall stand rejected and shall be removed from the site by the contractor at his own cost within a weeks time of written order from the Engineer-in-Charge to do so. The cement shall be brought at site in bulk supply as decided by the Engineer-in-Charge. The cement godown of the capacity to store about 2000 bags of cement or as decided by the Engineer-in-Charge shall be constructed by the contractor at site of work for which no extra payment shall be made. Double lock provision shall be made to the door of the cement godown. The keys of one lock shall remain with the Engineer-in-Charge or his authorized representative and the key of other lock shall remain with the contractor. The contractor shall facilitate the inspection of the cement godown by the Engineer-in-Charge at any time. The contractor shall supply free of charge the cement required for testing. The cost of tests shall be borne by the contractor/Department in the manner indicated below. (i) By the contractor, if the results show that the cement does not conform to relevant BIS Codes. By the Department, if the results show that the cement conforms to relevant BIS codes.

3.

4.

4.1 4.1.1

4.1.2 4.1.3.

4.1.4

(ii)

4.2 4.2.1

STEEL The contractor shall procure steel reinforcement bars conforming to relevant BIS Codes from main producers as approved by the Ministry of Steel. For TMT Bars conforming to relevant BIS codes, procurement shall be made from main producers having valid BIS Licence. The contractor shall have to obtain and furnish test certificates to the Engineer-in-Charge in respect of all supplies of steel brought by him to the site of work. Samples shall also be taken and got tested by the Engineer-in-Charge as per the provisions in this regard in the relevant BIS Codes. In case the test results indicate that the steel arranged by the contractor does not conform to BIS Codes, the same shall stand rejected and shall be removed from the site of work within a weeks time from written order from the Engineer-in-Charge to do so.

19

4.2.2

The steel reinforcements shall be stored by the contractor at site of work in such a way as to prevent distortion and corrosion and nothing extra shall be paid on this account. Bars of different sizes (diameters) and lengths shall be stored separately to facilitate easy counting and checking. For checking nominal mass, tensile strength, bend test, re-bend test, elongation test, proof stress etc. specimen of sufficient length shall be cut from each diameter of the bar at random at frequency not less than that specified below. For Consignment ----------------------------------------------------------Below 100 tonnes Over 100 tonnes One sample for each One sample for each 40 25 tonnes or part thereof tonnes or part thereof One same for each 35 tonnes or part thereof One sample for each 45 tonnes or part thereof. One sample for each 45 tonnes or part thereof One sample for each 50 Tonnes or part thereof

4.2.3

Size(Diameter) of bar Under to 10mm dia

10mm to 16 mm dia

Over 16mm dia

4.2.4

The contractor shall supply free of charge the steel bars required for testing. The cost of tests shall be borne by the contractor/Department in the manner indicated below. (i) (ii) By the contractor, if the results show that the steel does note conform to relevant BIS Codes. By the Department, if the results show that the steel conforms to relevant BIS codes.

4.2.5

Coefficient of weight i.e., the weight per unit length of the steel procured by the contractor shall be ascertained at site before using it and certified by the Engineer-in-Charge. In case weight per unit length is beyond the rolling margin as laid down in the BIS: 1786, the steel will be rejected and shall be removed as per para 5.2.1 above from the site of work within a weeks time from written order from the Engineer-in-Charge to do so. In case weight per unit length is more than the standard coefficient of weight for the diameter, but is within the rolling margin, then the payment shall be made as per the standard weight per unit length, and, where the weight per unit length is lesser than the standard coefficient of weight for the diameter, but is within the rolling margin, the payment shall be restricted with respect to the actual weight per unit length of the diameter. The standard sectional weights referred to in standard table under para 5.3.3, CPWD Specifications for Cement Mortar, Cement Concrete and RCC works, are to be considered for conversion of length of various sizes of Steel Reinforcement bars into weight. The actual issue and consumption of steel and cement on the work shall be regulated and proper accounts maintained as provided in clause 10 of the contract. The theoretical consumption of cement and steel shall be worked out as per procedure prescribed in Clause 42 of the contract ad shall be governed by conditions laid therein. Steel and Cement brought to site and remaining unused shall not be removed from site without the written permission of the Engineer-in-Charge. No payment shall be made to contractor for any damaged caused by rain, snowfall, floods or any other natural cause what so ever during the execution of work because of cause(s) not covered under Clause 43 of the Contract. The damage to work will be made good by the contractor at his cost, and no claim on this account be entertained. Some restrictions may be imposed by the security staff etc. on the working and/or movement of labour, materials etc. and the contractor shall be bound to follow all such restrictions/instructions and nothing extra shall be payable on this account.

4.3

4.4

4.5

5.

6.

20

7.

The Contractor shall comply with proper and legal orders and directions of the local or public authority or municipality and abide by their rules and regulations and pay all fees and charges which he may be liable and nothing extra shall be payable on this account. The work shall be carried out without infringing on any of the local Municipal Bye-Laws. The contractor shall engage licensed plumber for sanitary, water supply, drainage work and also get all the materials and system (including the materials supplied if any, by the department) tested by the Municipal Authority, whenever required, at his own cost including testing fees, transport etc. according to Municipal by Laws. The contractor shall produce necessary certificate from the Municipal Authorities after completion of work. Nothing extra will be paid on this account. The water supply sanitary installation and drainage work shall be carried out in a manner complying in all respects with the requirement of relevant by laws of the local municipal authority of the place at no extra of the department. The rate for every item of work to be done under this contract shall be for all heights, depths, lengths and widths of the structure (except where specially mentioned in the item) and nothing extra will be paid on this account. The contractor shall take all precautions to avoid all accidents by exhibiting necessary caution boards such as day and night boards, speed limit boards and flags, red lights and providing barriers etc. He shall be responsible for all the damages and accidents caused due to negligence on his part. No hindrance shall be caused to traffic during the execution of work. Nothing extra will be paid on this account. The contractor will work in close liaison, during the works, with other contractors of water supply, sanitary, drainage arrangements, electrical installation and any other works and adjust his work plan accordingly. The contractor shall be required to produce samples of all materials and fittings sufficiently in advance for obtaining approval of the Engineer-in-Charge. The contractor shall be responsible to arrange on his own cost all necessary tools and plants required for execution of work. The contractor shall provide at his own cost suitable weighing and measurement arrangements at site for checking weight/dimensions as may be necessary for the execution of the work. The contractor shall maintain all work in good condition during the execution and till completion of entire work allotted to him. Any damage done by the contractor to any existing work during the course of execution of work tendered for shall be made good by him at his own cost. The rate for all items of work wherein cements is used inclusive of charges for curing. Samples of various materials required for testing shall be provided free of charges by the contractor. Testing charges, if any shall be borne by the Deptt. If the test results are satisfactory and are in conformity to the relevant provisions of the specifications. All other expenditure required to be incurred for taking samples, conveyance, packing, octroi/Tax, if any, etc. shall be borne by the contractor himself. The contractor shall keep the site clear thoroughly of rubbish unless scaffolding and materials etc. from time to time as well as before the actual date of completion of the work as per directions of the Engineer-in-Charge. The doors and windows frames & shutters shall not be painted, oiled or otherwise treated and fixed in position before these are approved by the Engineer-in-Charge. OTHER TAXES AND ROYALTIES Works Contract Sales Tax as prevalent as per statutory orders of State/Central Government and shall be charged on gross value of all the bills and shall be recovered from bill of the contractor as works contract sales tax should there be any increase in rate of works Contract Sales Tax during execution of the contract, the same shall also be payable by the contractor. 21

8.

9.

10.

11.

12.

13.

14.

15.

16. 17.

18.

19.

20 20.1

20.2

Royalty shall have to be paid by the contractor on all materials such as stone, bricks, boulders, metal, shingle, bajri, stone aggregate, coarse sand and fine sand etc. or any other materials used for the execution of the work direct to the Revenue Authority of the District/ State Govt. concerned. The contractor shall obtain No Demand Certificate from the District/State Govt. authority concerned before the final bill is paid, failing which necessary recovery will be effected at the applicable rates in the final bill. The contractor shall obtain labour clearance certificate from the designated Labour Commissioner or other designated authority of the State/Central Government and submit same to the Engineerin-Charge before payment of final bill. PROGRAMME FOR EXECUTION OF WORK The contractor shall submit a time and progress chart to the Engineer-in-Charge including the duration of various construction activities for completion of work within 15 days from the date of award. The total time taken for various activities should not exceed the stipulated time of completion specified in the tender. The chart should be updated as per the progress in the work and shall be operated as per Clause 5 of the contract. The work shall be executed as per programme approved by Engineer-in-Charge of the work. No claim what so ever will be entertained on this account. ARRANGEMENT OF WATER AND PAYMENT OF CHARGES ETC. IN CONNECTION WITH WATER USED FOR CONSTRUCTION PURPOSE The contractor shall make his own arrangement for the water to be used for construction purpose. The contractor will get the water tested before execution of work. The water used for construction shall conform to the relevant provisions as mentioned under para 3.1.1 on page 68 of revised CPWD specifications 2009 for cement mortar, cement concrete and RCC works. Water required for the execution of work may be sup-plied to the contractor in case of availability of water at discretion of the Engineer-in-Charge in accordance to Clause 31-A of contract documents. The charge (if any) etc. incidental to water used for construction purpose shall be borne by the contractor/agency under the following cases:In case of temporary water connection from municipal mains the water charges and sewerage charges (including water used for construction purposes) have to be borne by the Contractor. In case of water used from other sources, the prior permission for using the water for construction purpose has to be obtained from municipal corporation/ Local Bodies by the Contractor. Water charges sewerage charges, or any other charges, for use of water from other sources for construction purposes have to be borne by the contractor. PARTICULAR SPECIFICATIONS GENERAL The work, shall in general, conform to the CPWD specifications shall mean CPWD specifications 2007 Should there be any difference between the specifications mentioned above and the specifications given in the Schedule of quantities, the later shall prevail. If the specifications for any item are not available in the CPWD specifications cited above, relevant BIS Specifications should be followed. In case BIS Specifications are also not available, the decision of Engineer-in-Charge given in writing based on acceptable sound engineering practice and local usage shall be final and binding on the contractor.

20.3

21. 21.1

21.2

22

22.1

22.2

22.3

22.3.1

22.3.2

B 1. 1.1 1.1.1

1.1.2

1.1.3

22

1.2

The work will be carried out in accordance with the architectural drawings and structural drawings. The Structural and architectural drawings shall have to be properly correlated before executing the work. In case of any difference noticed between Architectural and Structural drawings, the contractor shall obtain decision in writing of the Engineer-in-Charge. In case of discrepancy in the item given in the schedule of quantities appended with the tender and architectural drawings relating to the relevant item, former shall prevail unless otherwise given in writing by the Engineer-in-Charge. The following modifications to the above specifications shall, however, apply. EARTH WORK During excavation and trenching work etc. the contractors shall ensure compliance to the guidelines in such matters laid down by the local body/bodies to ensure that there is minimum hazard to the operating personals and users, minimum inconvenience to the users, minimized damage to the underground plan/ services of other utilities in a coordinated way, in the interest of public convenience and overall safety. Any trenching and digging for laying sewer lines/ water lines/ cables etc. shall be commenced by the contractor only when all men, machinerys and materials have been arranged and closing of the trench(s) thereafter shall be ensured within the least possible time. Surplus excavated earth which is beyond the requirement of D.O.P. shall have to be disposed of by the contractor at his own cost beyond the municipal limits or at places identified by the local bodies or as directed by the Engineer-in-Charge after obtaining written permission of the Engineer-in-Charge and no payment will be made by the Department for such disposal of this surplus excavated earth.

1.2.1

1.2.2

2. 2.1 2.1.1

2.1.2

2.1.3

2.1.4

The contractor shall, at his own expense and without extra charges, make provision for all shoring, pumping, dredging or bailing out water, if necessary, irrespective of the source of water. The foundation trenches shall be kept free from water while all the works below Ground level are in progress, without any extra payment. Reinforced Cement Concrete Work & Plain Cement Concrete General Where only one variety of sand is available, the sand will be sieved for use in finishing work to achieve the required particle size distribution as per CPWD specifications in order to obtain smooth surface and nothing extra shall be paid to the contractor on this account. Sand to be used shall not have any chloride/sulphate or any other impurities beyond permissible limit given in the CPWD specification. Water:- It shall conform to requirements laid down in IS: 456-2000 and CPWD Specification. R.C.C. work (Nominal mix concrete)-Water-Cement Ratio:For RCC Works, wherever nominal mix of concrete is stipulated in the items for work, For maintaining proper quality and durability requirements of the structure, maximum water-cement ratio shall be restricted to 0.55. If in normal course of work, the required workability is not achieved; suitable plasticizers/admixtures may be used for improving the workability of concrete with the approval of Engineer-in-Charge for which nothing extra shall be paid.

2.2
2.2.1

2.2.2

2.2.3 2.3

2.3.1

For concreting work, mixer with lifting hopper shall have to be used for mixing concrete.

23

2.4

Cement Slurry, if any,. Added over base, surface(or) for continuation of concreting for better bond is deemed to have been in built in the terms (Unless other wise explicitly stated and nothing extra shall be payable (or) extra cement considered in consumption on this account. Centering and Shuttering for R.C.C. work:The concrete surface shall be free from honey combing, offsets, superfluous mortar, Cement slurry and foreign matter. The form work shall be assembled in such a way as to facilitate removal of their parts in proper sequence without any damage to the exposed cement concrete surfaces and corners etc. The contractor shall keep skilled staff for special care and supervision to check the form work and concreting so that every member is made true to its size, shape, level and alignment so that it does not result in any deformation, snug, buldges etc. The contractor shall also take suitable precautionary measure to prevent breaking and chipping of corners and edges of completed work until the building is handed over. The size of shuttering plates for slabs shall not be less than 0.6m x 0.9m in general. However, Contractor has to provide tape to seal the joint properly to get smooth surface. Further shuttering shall be of such quality that there are no undulations and surfaces will be fairly even and no extra thick ceiling plaster shall be permitted to make the surface even.

2.5

2.6

STEEL WORK:-All Steel doors, steel windows, steel ventilators, wire gauge, steel glazing, steel grill shall be according to the Architects detailed drawings. These shall conform to the CPWD specification. In the case of composite steel windows the rates shall include the cost of coupling mullion and transom etc. where windows with inside openable shutters are fixed along with windows with shutters openable outside, such inside openable windows shall be fitted with suitable friction hinges and openable outside with box type hinges, lever handles or otherwise as approved by the Engineer-in-Charge of the work. For such windows, cement concrete block of size 15cm x 10cm x 10cm shall be provided. Nothing extra shall be paid on this account. In the case of steel windows and doors, steel glazing, wire gauge steel ventilators, rolling shutters, grills etc. an approved quality-priming coat of zinc chromate shall be applied over and above shop coat of primer. Nothing extra shall be payable for providing shop-coat primer. IMPORTANT NOTES;Mandatory tests as provided for in the CPWD specification or other specification referred to above shall be got done as prescribed. Any infringement and/or breach of the above specification and condition (s) etc. shall render the contractor liable to action(s) under various Clauses of the contract and such action stipulated in conditions therein. The quoted rates for various items in the tender shall be inclusive of all the additional conditions and specification and for adherence to all these conditions and specifications, no extra payment shall be made to the Contractor.

2.6.1

2.6.2

3. 3.1

3.2

3.3

24

SPECIAL CONDITIONS FOR ISI MARKED ITEMS


1. 2. Copies of vouchers of ISI mark items shall be submitted, then only the payment shall be made. If the contractor fails to provide copies of vouchers, then materials shall be test from Laboratory viz. Nation Test House, Calcutta/Delhi and Sriram Test House , New Delhi and expenses shall be borne by the contractor. 3. If any material other then specified in the nomenclature of the item is provided, the deduction will be made as per the actual market rate difference between them.

SPECIAL CONDITIONS FOR PAINT WORK


1. For paint work, the theoretical quantity as per manufacturers specifications shall be brought to the site in a single lot and not in batches and shall be got approved by the Engineer-in-Charge.

SPECIAL CONDITIONS FOR VITRIFIED TILES, CERAMIC TILES AND FLOOR TILES
1 Original vouchers shall be produced at the time of execution of work and the same shall be enclosed with the bill for record. 2 Shade, colour, manufacturer shall be got approved from the Engineer-in-Charge before execution.

Contractor

Engineer-in-Charge

25

SCHEDULE D Special Conditions/ Specific requirements for the work:1. The Products shall qualify the tests as per BIFMA standards. The Product/ Company should have ISO:9001:2000 and ISO 14001:2004 certificates. 2. The work shall be carried out as per the detailed drawings made available by the Engineer-inCharge. 3. The contractor shall submit the details of the item prior to its purchase. 4. The Engineer-in-charge/ Officer from DOP shall be allowed to inspect the material in the factory/ showroom of the manufacturer of the item, prior to convey the final approval to the contractor for its procurement. 5. The contractor shall be liable to bring the material at site in good condition. 6. The Engineer-in-charge may ask for the proof of purchase from the approved manufacturer of the item, in the form of invoice/ bill from the contractor to support that the material has been procured from the same manufacturer as approved in Sr. No. 3 above. 7. The rates quoted by the contractor shall be inclusive of all taxes viz. VAT, Tax/ Cess charged by the Local bodies. 8. The rates shall include all carriage, packing, unpacking and FOR Delivery at site. 9. The contractor shall insure 6 months warranty in addition to defect liability period as mentioned in standard CPWD-8 for all the items. (This will be in form of a Guarantee Bond. No money will be withheld from the bill on this account). 10. The contractor shall be liable for any damage made to the existing property of the Govt. during installation work; the contractor at his own cost should rectify the same. 11. The Department shall recover the IT with cess as applicable from the bills paid for the work. 12. The Department shall recover the Sales Tax as applicable for Civil Contracts by Government from the bills paid for work.

Contractor

Engineer-in-Charge

26

SCHEDULE OF QUANTITY
Name of Work :- Construction of Post office building at Palam Vihar, Gurgaon.(Haryana) Estimated Cost :- ` 2955357/Earnest Money :- ` 59110/Time
S. No. Description of Items Sub-Head :- Earth Work

:- 8 (Eight) Months
Quantity Unit Rate in words & Figures Amount

1 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm onplan)includingdisposalofexcavated earth,leadupto50mandliftupto1.5m, disposed earth to be levelled and neatly dressed. a)Allkindsofsoil 2 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (notexceeding1.5minwidthor10sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil anddisposalofsurplusexcavatedsoilas directed,withinaleadof50m. a)Allkindsofsoil. 3 Excavatingtrenchesofrequiredwidthfor pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m includinggettingouttheexcavatedsoil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed,withinaleadof50m: a)Allkindsofsoil i)Pipes,cablesetc.exceeding80mmdia. butnotexceeding300mmdia. 4 Filling available excavated earth (excludingrock)intrenches,plinth,sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m. 5 Supplying and filling in plinth with local fine sand under floors including, watering, ramming consolidating and dressingcomplete.

105 cum

17

cum

87 metre

122

cum

49

cum
27

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

SubHead:ConcreteWork
Providing and laying in position cement concreteofspecifiedgradeexcludingthe costofcentringandshutteringAllwork uptoplinthlevel: a) 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns,piers,abutments,pillars,posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor five level, excluding the costofcentring,shutteringandfinishing : a) 1:2:4 (1 Cement : 2 coarse sand : 4 gradedstoneaggregate20mmnominal size) Providing and laying dampproof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate20mmnominalsize). Extra for providing and mixing water proofing material in cement concrete work@1kgper50kgofcement. Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finallywithapieceofclothlightlysoaked inkeroseneoil.

29.00

cum

cum

10

sqm per50 kg cement

10

SubHead:R.C.C.Work 1 Providingandlayinginpositionspecified grade of reinforced cement concrete excluding the cost of centring, shuttering,finishingandreinforcement Allworkuptoplinthlevel: a)1:1:3(1cement:1coarsesand:3 graded stone aggregate 20 mm nominal size) 2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floorfivelevelexcludingcostofcentring, shuttering,finishingandreinforcement

sqm

22.00

cum

28

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

a)1:1:3(1cement:1coarsesand:3 graded stone aggregate 20 mm nominal size) 3 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the costofcentring,shuttering,finishingand reinforcementwith1:1.5:3(1cement : 1.5 coarse sand : 3 graded stone aggregate20mmnominalsize). 4 Centring and shuttering including strutting, propping etc. and removal of formfor: a) Foundations, footings, bases of columns,etc.formassconcrete. b) Suspended floors, roofs, landings, balconiesandaccessplatform. c)Shelves(Castinsitu) d) Lintels, beams, plinth beams, girders, bressumersandcantilevers. e) Columns, Pillars, Piers, Abutments, PostsandStruts. f) Stairs, (excluding landings) except spiralstaircases. g) Weather shade, Chajjas, corbels etc., includingedges. 5 Reinforcement for R.C.C. work including straightening,cutting,bending,placingin positionandbindingallcomplete. a)ThermomechanicallyTreatedBars SubHead:BrickWork 1 Brick work with F.P.S. bricks of class designation75infoundationandplinth in: a) Cement mortar 1:6 (1 cement : 6 coarsesand) 2 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapesandsizesin: a) Cement mortar 1:6 (1 cement : 6 coarsesand) 3 Half brick masonry with F.P.S. brick of class designation 75 in foundations and plinthin: a) Cement mortar 1:4 (1 cement : 4 coarsesand) 4 Half brick masonry with F.P.S. bricks of class designation 75 in superstructure aboveplinthleveluptofloorVlevel.

16.00

cum

50

cum

10 185 5 200 69 40 32 sqm sqm sqm sqm sqm sqm sqm

16500

kg

30.00 cum

65.00 cum

10.00 sqm

29

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

a) Cement mortar 1:4 (1 cement :4 coarsesand) SUBHEAD:MARBLEWORK 1 Providing and fixing 18mm thick gang saw cut mirror polished (premoulded andprepolished)machinecutforkitchen platforms,vanitycounters,windowsills, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curingmouldingandpolishingtoedgeto givehighglossfinishetc.completeatall levels. a)Graniteofanycolourandshade i)Areaofslabupto0.50sum 2 Extra for providing edge moulding to 18mm thick marble stone counters, Vanitiesetc.includingmachinepolishing to edge to give high gloss finish etc. complete as per design approved by EngineerinCharge. a)Marble/kotastonework 3 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150mmwithepoxyresinbasedadhesive includingcleaningetc.complete. SubHead:WoodWork 1 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) nondecorative type, core of block board construction with frame of 1st class hard wood and well matched commercial3plyveneeringwithvertical grains or cross bands and face veneers onbothfacesofshutters: a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessaryscrews. b) 25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S.pianohingeswithnecessaryscrews. 2 Extra for cutting rebate in flush door shutters(Totalareaoftheshuttertobe measured). 4 Providingandfixingwoodenmouldingto railing/roughwallwithironscrews,plugs and priming coat on unexposed surface

73

sqm

12

sqm

metre

metre

23.00

sqm

sqm

sqm

30

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

10

etc.complete. a)2ndclassteakwood i)50x50mm Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass bracketsfixedwithC.P.brassscrewsand wooden plugs, etc., wherever necessary complete: a)12mmdia. Providing and fixing M.S. grills of required pattern in frames of windows etc.withM.S.flats,squareorroundbars etc.allcomplete. a)Fixedtosteelwindowsbywelding. Providing and fixing fly proof galvanised M.S. wire gauze to windows and clerestorywindowsusinggalvanisedM.S. wire gauge with average width of aperture1.4 mminbothdirectionswith wireofdia.0.63mm. With12mmmildsteelUbeading. ProvidingM.S.PianohingesISImarkedIS : 3818 finished with nickel plating and fixing with necessary screws etc., complete. a)Overallwidth35mm. Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete: a)150x10mm b)100x10mm Providing and fixing oxidised M.S. casement stays (straight peg type) with necessaryscrewsetc.complete. a) 300 mm weighing not less than 200 gms.

82 metre

12

metre

764

kg

sqm

18

metre

61 36

each each

44 each

11 Providing and fixing special quality bright finished brass cupboard or wardrobe locks with four levers including necessary screws etc. complete (best make of approved quality): a)65mm 12 Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. 13 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coatingnotlessthangradeAC10asper 2

each

each

31

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

14

15

16

17

18

19

IS : 1868) transparent or dyed to required colour or shade with nuts and screwsetc.complete: a)300x16mm b)250x16mm Providing and fixing aluminium tower bolts ISI marked anodised (anodic coatingnotlessthangradeAC10asper IS : 1868 ) transparent or dyed to required colour or shade with necessary screwsetc.complete: a)300x10mm b)150x10mm Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparentordyedtorequiredcolouror shade with necessary screws etc. complete: a)125mm b)100mm Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodiccoatingnotlessthangradeAC10 asperIS:1868)transparentordyedto required colour and shade with necessaryscrewsetc.complete. a)Twinrubberstopper Providingandfixing2ndclassteakwood lipping/mouldedbeadingorTajbeading of size 18X5mm fixed with wooden adhesive of approved quality and screws/ nails on the edges of the block board as per direction of Engineerin charge. Providing and fixing magnetic catcher in cupboard/wardrobeshuttersincluding fixing with necessary screws etc. complete (Best make of approved quality. a)Doublestrip(horizontaltype). Providing and fixing factory made P.V.C. doorframeofsize50x47mmwithawall thicknessof5mm,madeoutofextruded 5mm rigid PVC foam sheet mitred at cornersandjoinedwith2Nos.of150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weathersealtobeprovidedthroughout theframe.Thedoorframetobefixedto thewallusingM.S.screwsof65/100mm

6 25

each each

24 24

each each

40 10

each each

20

each

32

each

each

30

metre
32

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

size complete as per manufacturers specification and direction of Engineer inCharge. 20 Providing and fixing to existing door frames. a) 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness andsizeof19mmx19mmforstylesand 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture . M.S.framecoveredwith5mmthickheat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be taperedin45degreeangleoneitherside forming styles; and 5mm thick, 95mm widePVCsheetoutofwhich75mmshall beflatand20mmshallbetaperedin45 degreeontheinnersidetoformtopand bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to formlockrail.Top,bottomandlockrails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm widecrossPVCsheetbeprovidedasgap insertfortoprail&bottomrail.paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mmwidthistobestuckontheinterior sideofthe'C'ChannelusingPVCsolvent adhesive etc. complete as per direction of Engineerincharge. Manufacturers specification & drawing (for W.C. and bathroomdoorshutter). 21 Providing & Fixing decorative high pressurelaminatedsheetofplain/wood grain in gloss / matt / suede finish with highdensityprotectivesurfacelayerand reversesideofadhesivebondingquality conformingtoIS:2046TypeSincluding costofadhesiveofapprovedquality. a)1.0mmthick. 22 ProvidingandfixingaluminumUbeading of required size to Prelaminated /flush door shutter including fixing etc. completeasperdirectionofEngineerin

sqm

sqm

10

Kg
33

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

charge.

SubHead:SteelWork
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flatirondiagonals20x5mmsizewithtop and bottom rail of Tiron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a primingcoatofapprovedsteelprimer. Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angleironand3mmM.S.gussetplatesat the junctions and corners, all necessary fittings complete, including applying a primingcoatofapprovedsteelprimer. a) Using M.S. angels 40x40x6 mm for diagonalbraces. Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including thecostofprovidingandfixingnecessary 27.5cmlongwirespringsgradeNo.2and M.S. top cover of required thickness for rollingshutters. a) 80x1.20 mm M.S. laths with 1.20 mm thicktopcover. Providing and fixing ball bearing for rollingshutters. Providing and fixing factory made ISI markedsteelglazeddoors,windowsand ventilators side /top /centre hung with beading and all members such as K11 B and K12 B etc. complete of standard rolled steel sections, joints mitered and flash butt welded and sash bars tanned and riveted with 15x3mm lugs, 10cm long, embedded in cement concrete blocks15x10x10cmof1:3:6(1cement:3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts andnutsasrequired,includingproviding and fixing of hinges, pivots, float glass

12

sqm

2 sqm

6 2 sqm each

4 5

480.00

kg
34

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

paneswithglazingclipsandspecialmetal sash putty of approved make and a priming coat of approved steel primer excludingthecostofotherfittingsexcept necessary hinges or pivots complete as per approved design. (Sectional weight ofonlysteelmembersshallbemeasured forpaymentwithoutweightofglassand otherfittings). 6 Providing and fixing factory made ISI markedsteelglazeddoors,windowsand ventilators side /top /centre hung with beading and all members such as K11 B and K12 B etc. complete of standard rolled steel sections, joints mitered and flash butt welded and sash bars tinned and riveted with 15x3mm lugs, 10cm long, embedded in cement concrete blocks15x10x10cmof1:3:6(1cement:3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or drawl plugs and screws or with fixing clips or with bolts andnutsasrequired,includingproviding and fixing of hinges, pivots, galvanized M.S. wire gauge of average width of aperture 104mm with wire dia 0.63mm with glazing clips and special metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of other fittings except necessary hinges or pivots complete as per approved design. (Sectional weight ofonlysteelmembersshallbemeasured for payment without weight of galvanizedwiremeshandotherfittings). 7 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steelangleofsection50x25mm,orbase ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with splitendtailtoeachjambincludingsteel butt hinges 2.5mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre treatment of the surface as directed by Engineerincharge: a)ProfileB b)ProfileC

58

kg

52 15

metre metre
35

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

8 Providing and fixing M.S. Tubular wire gauge shutters for doors, windows and ventilatorswithLTypesectionmadeof 1.60mm thick M.S. Sheet, joints mitered and welded and grinded finish with profiles of required size including fixing ofnecessarybutthingesandscrewsand applyingaprimingcoatofapprovedsteel primers ( wire gauge shall be paid for separately) 9 Steel work in built up tubular trusses including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc.complete. a)Hotfinishedweldedtypetubes 10 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structuralsteeletc.asrequired. a)Ingratings,frames,guardbar,ladder, railings, brackets, gates and similar works. SubHead:Flooring 1 Marble stone flooring with 18mm thick marblestone(sampleofmarbleshallbe approvedbyEngineerincharge)over20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry includingrubbingandpolishingcomplete with: a)RajNagarplain/Morwadplainwhite 2 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewithbaseofcementmortar1 :4(1cement:4coarsesand): a)25mmthick. 3 Kotastoneslabs25mmthickinrisersof steps,skirting,dadoandpillarslaidon12 mm(average)thickcementmortar1:3(1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 4 Extraforprefinishednosingintreadsof stepsofKotastone/sandstoneslab.

30

kg

482

kg

2291

kg

75

sqm

70

sqm

75.00

sqm Metre
36

75.00

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

5 Extra for Kota stone/ sand stone in treads of steps and risers using single lengthupto1.05metre. 6 Providing and fixing Ist quality ceramic glazedwalltilesconformingtoIS:15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by EngineerinCharge in skirting, risers of stepsanddadosover12mmthickbedof cementMortar1:3(1 cement:3coarse sand) and jointing with grey cement slurry @ 3.3kg per sum including pointing in white cement mixed with pigmentofmatchingshadecomplete. 7 ProvidingandlayingCeramicglazedfloor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approvedmakeincolourssuchasWhite, Ivory,Grey,FumeRedBrown,laidon20 mmthickCementMortar1:4(1Cement: 4 Coarse sand) including pointing the joints with white cement and matching pigmentetc.,complete. SubHead:Roofing 1 Providing nonasbestos high impact
Polypropylenereinforcedcement6mmthick corrugated sheets (As per IS:14871) roofing upto any pitch and fixing with polymer coatedJorLhooks,boltsandnuts8mmdia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete excluding the cost of purling, rafters and trusses: corrugated sheets and includingcuttingtosizeandshapewherever required.

30

sqm

85

sqm

51

sqm

20 21

sqm metre

2 Extraforprovidingandfixingwindtiesof 40x6mmflatironsection. 3 Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gapforthermalexpansion.(i) Singlesocketedpipes a)110mmdiameter 4 Providing and fixing on wall face Unplasticised PVC moulded fittings/ accessories for Unplasticised Rigid PVC rainwaterpipesconformingtoIS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gapforthermalexpansion.

21 metre

37

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

a)Bend87.5degreeof110mmdia 5 Providing and fixing Unplasticised PVC pipe clips of approved design to Unplasticised PVC rain water pipes by meansof50x50x50mmhardwoodplugs, screwed with M.S. screws of required length including cutting brick work and fixingincementmortar1:4(1cement:4 coarse sand) and making good the wall etc.complete. a)110mm 6 Providingandfixingtotheinletmouthof rain water pipe cast iron grating 15 cm diameterandweighingnotlessthan440 grams. SubHead:Finishing 1 12mmcementplasterofmix: a)1:4(1cement:4coarsesand) b)1:6(1cement:6coarsesand) 2 15 mm cement plaster on rough side of singleorhalfbrickwallofmix: a)1:4(1cement:4coarsesand) b)1:6(1cement:6coarsesand) 3 6mmcementplasterofmix: a)1:3(1cement:3finesand) 4 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smoothcomplete 5 Whitewashingwithlimetogiveaneven shade: a)Newwork(threeormorecoats) 6 Distempering with oil bound washable distemper of approved brand and manufacturetogiveanevenshade a) New work (two or more coats) over and including priming coat with cement primer. 7 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additivesofrequiredshade a)Newwork(Twoormorecoatsapplied @ 1.43 ltr/ 10 sum. over and including base coat of water proofing cement paintapplied@2.20kg/10sum). 8 Applyingprimingcoat: a)WithreadymixedpinkorGreyprimer of approved brand and manufacture on woodwork(hardandsoftwood)

each

10

each

396.0 50

each sqm sqm sqm sqm sqm

95.0 370 180

600.00

sqm sqm

37

563

sqm

491.00

sqm

63

sqm
38

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

9 Painting with synthetic enamel paint of approved brand and manufacture of requiredcolourtogiveanevenshade: a)Twoormorecoatsonnewworkover an under coat of suitable shade with ordinary paint of approved brand and manufacture. 1

405.81

sqm

SubHead:SanitararyInstallation
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the wallsandfloorswhereverrequired: a) White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integraltypefootrests. ProvidingandfixingwashbasinwithC.I. brackets,15mmC.P.brasspillartaps,32 mmC.P.brasswasteofstandardpattern, including painting of fittings and brackets, cutting and making good the wallswhereverrequire: a) White Vitreous China Flat back wash basin size 550x400 mm with single 15 mmC.P.brasspillartap. Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the receptionofpipesandfittings. Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 withC.I.bracketsandstainlesssteelplug 40 mm including painting of fittings and brackets, cutting and making good the wallswhereverrequired: a)Kitchensinkwithoutdrainboard i)610x460mmbowldepth200mm. ProvidingandfixingP.V.C.wastepipefor sinkorwashbasinincludingP.V.C.waste fittingscomplete. a)Flexiblepipe i)32mmdia ii)40mmdia

each

each

each

each

5 1

each each
39

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

6 Providing and fixing 600x450 mm bevelededgemirrorofsuperiorglass(of approved quality) complete with 6 mm thickhardboardgroundfixedtowooden cleatswithC.P.brassscrewsandwashers complete. 7 Providingandfixingsoil,wasteandvent pipes: a)100mmdia. i)SandcastironS&SpipeasperIS:1729. 8 Providing and fixing M.S. holderbat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cuttingholesandmakinggoodthewalls etc.: a)For100mmdia.Pipe 9 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nutscomplete. a)100mm i)SandcastironS&SasperIS1729 10 Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick,boltsandnutscomplete: a)100x100x100x100mm i)SandcastironS&SasperIS1729 11 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick,boltsandnutscomplete. a)100x100x100mm i)SandcastironS&SasperIS1729 12 Providingandfixingtrapofselfcleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and makinggoodthewallsandfloors: a)100mminletand100mmoutlet i)SandcastironS&SasperIS:3989. SubHead:WaterSupply 1 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. InternalworkExposedonwall a)15mmdia.nominalbore b)20mmdia.nominalbore

each metre

85

18

each

each

each

each

each

1 51

metre metre
40

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

c)25mmdia.nominalbore 2 Concealed pipe including painting with anti corrosive bit mastic paint, cutting chasesandmakinggoodthewall. a)15mmdianominalbore b)20mmdianominalbore 3 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. Externalwork: a)25mmdia.nominalbore 4 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: a)25to40mmnominalbore 5 Fixing water meter and stop cock in G.I. pipelineincludingcuttingandthreading the pipe and making long screws etc. complete (cost of water meter and stop cocktobepaidseparately). 6 Providingandfixinggunmetalgatevalve with C.I. wheel of approved quality (screwedend): a)20mmnominalbore 7 Providing and fixing uplasticised PVC connectionpipewithbrassunions: a)45cmlength i)15mmnominalbore 8 Painting G.I. pipes and fittings with synthetic enamel white paint over a ready mixed priming coat, both of approvedqualityfornewwork: a)15mmdiameterpipe. b)20mmdiameterpipe. C)25mmdiameterpipe. 9 Painting G.I. pipes and fittings with two coatsofanticorrosivebitmasticpaintof approvedquality: a)25mmdiameterpipe 10 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete(Newwork) a)15mmnominalbore b)20mmnominalbore c)25mmnominalbore 11 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitablelockingarrangementandmaking necessary holes for inlet, outlet and

100

metre

25 50

metre metre

45

metre

each

each

each each

20 51 100

metre metre metre

45

metre

4 6 4

each each each

5000

perlitre capacity
41

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

overflow pipes but without fittings and thebasesupportfortank 12 ProvidingandfixingC.P.brassbibcockof approvedqualityconformingtoIS:8931 a)15mmnominalbore. 13 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approvedmakeconformingtoIS:8931. a)15mmnominalbore.

each

each

SubHead:Drainage 1 Providing, laying and jointing glazed stoneware pipes grade A with stiff mixture of cement mortar in the proportionof1:1(1cement:1finesand) includingtestingofjointsetc.complete: a)150mmdiameter 2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) allround S.W. pipes including bed concreteasperstandarddesign: a)150mmdiameterS.W.pipe 3 Providing and fixing squaremouth S.W. gully trap grade 'A' complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frametobenotlessthan2.70kgasper standarddesign: a)100x100mmsizePtype i)WithF.P.S.Bricksclassdesignation75 4 Constructing brick masonry manhole in cementmortar1:4(1cement:4coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement:2coarsesand:4gradedstone aggregate 20 mm nominal size), foundationconcrete1:4:8mix(1cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete1:2:4(1cement:2coarsesand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standarddesign: a) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions totalweightofcoverandframetobenot less than 38 kg (weight of cover 23 kg

87

metre

87

metre

each

42

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

andweightofframe15kg): i) With F.P.S. bricks with class designation75 b)Insidesize120x90cmand90cmdeep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weightofcoverandframetobenotless than 116 kg (weight of cover 58 kg and weightofframe58kg): i)WithF.P.S.bricksclassdesignation75 5 Makingconnectionofdrainorsewerline withexistingmanholeincludingbreaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement:2coarsesand:4gradedstone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels forthedrainetc.complete: a)Forpipes100to230mmdiameter 6 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standarddesign: a)WithF.P.S.bricks SubHead:AluminiumWork 1 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standardtubularsections/appropriateZ sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with drawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminum snap beadingforglazing/paneling,C.P.brass / stainless steel screws, all complete as per architectural drawings and the directionsofEngineerincharge.(Glazing andpanelingtobepaidforseparately): a)Forfixedportion. i) Anodized aluminum (anodized transparent or dyed to required shade

each

each

each

14

each

21 kg
43

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

according to IS: 1868, Minimum anodic coatingofgradeAC15) b) For shutters of doors, windows & ventilatorsincludingprovidingandfixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasketrequired(Fittingsshallbepaidfor separately). i) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coatingofgradeAC15) Providing and fixing 12mm thick Pre laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screwsetc.completeasperarchitectural drawings and directions of engineerin charge. a) Prelaminated particle board with decorativelaminationonbothsides. Providingandfixingglazinginaluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architecturaldrawingsandthedirections of engineerincharge . (Cost of aluminiumsnapbeadingshallbepaid in basicitem): a) With float glass panes of 5.00 mm thickness Providing and fixing double action hydraulicfloorspringofapprovedbrand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S.sheetouterboxwithslideplateetc. complete as per the direction of Engineerincharge. a)Withstainlesssteelcoverplate Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick&2100mmlongwithSSscrewsetc .complete as per direction of Engineer inCharge. a) Anodized (AC 15 ) aluminium tubular handlebar Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary

33

kg

2 sqm

2 sqm

each

6 each

each
44

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

cuttingandmakinggoodetc.complete.

SubHead:WaterProofingWork
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C.,kitchen andthelike consistingof: i)Istcourseofapplyingcementslurry@ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding of junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to eachotherwithbitumen@1.7Kg/sqm.)
Providingandlayingintegralcementbasedwater proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a)Applyingaslurrycoatofneatcementusing2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved byEngineerinchargeovertheRCCslabincluding adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brickbats25mmto115mmsizewith50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerincharge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerincharge to required slope and treating similarly the adjoining walls upto 300 mm height includingroundingofjunctions ofwallsandslabs c) After two days of proper curing applying a secondcoatofcementslurryusing2.75kg/sqmof cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerincharge.

30

sqm

45

S. No.

Description of Items
d)Finishingthesurfacewith20mmthickjointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerincharge including laying glass fiber cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks forcuringandforfinaltest.Allaboveoperations tobedoneinorderandasdirectedandspecified bytheEngineerinCharge:

Quantity

Unit

Rate in words & Figures

Amount

SubHead:Misc.Work 1 Providing and fixing wooden customer service counter of size 1500 mm length 300mmwidthhavingheightof1050mm with attachment of working top having heightof750mmandofLshapehaving legs of 1500 mm x300mm and 1350mmx450 mm with tapering at joint of legs including arrangement of computer system as key board ,slit for printer paper etc. complete as per drawing no.A1to A6. The two nos stainless steel rectangular tube of size 25mmx50mm of 2mm thick, having height 2100mm fitted with counter to support the overhead signage panel as per drawing. The counter shall be made offollowingingredients: 1) 19mmthick block board (Conforming to IS:1659 BWP Grade),core of block boardconstructionwithframeofIstclass hard wood and well matched 3 ply veneering with vertical grains or cross bands. The board shall be 1st quality of approved brand Duro/Century/Kitply greenply/Archid,laminated with lamination of 1.0mm thick, decorative laminated and metallic steel finish decorative laminates of Greenlam/Century/Archid lam on outer face and inside face finished with white synthetic enamel paint over priming coat of approved quality of Nerolac/Asian/Bergerbrand. ii)Theedgesofboardshallbecoveredby 19 mm wide and 3 mm thick 2nd class teal wood margin and matching the same. iii)Thekeyboard&drawershallbefitted withpairof300mmlongpowdercoated

a)Withaveragethicknessof120mmand minimumthicknessatkhurraas65mm.

59

sqm


46

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

telescopic channels of approved quality ofmakeflyrail. 1v) The shutter below drawer in the counter shall be fitted with M.S piano type hinge ISI marked conforming to IS 13818 finished with nickel plating of overallwidth35mm. v) The shutter of counter shall be providedwith2nos.Magneticcatcherof heavyduty(twinstrip)horizontypebest quality, 3nos multipurpose cabinet locks of Godrej Make or equivalent and 4nos brushfinishstainlesssteelhandlesof75 mm long of best quality. The work shall include cost of all operations labour & Materials, adhesive nails stainless steel screws etc i/c approved of samples all completedasperdirectionofEngineerin charge. NoteNomenclature of item shallsupersedeoverthedrawingincase ofanyambiguitybetweenthetwo. 2 P/F an additional stainless steel rectangular member of section 25mmx50mm of thickness 1.5 mm and 1450mmlongbetweenverticalstainless steel tubes just below counter signage with 2no stainless steel corner cleats quarter round heavy duty of size 37mm of2.6mmthicknessfixedwithnecessary stainlesssteelscrewsand2no8mmthick grass panes of size 575x 770 mm including rounding off the edges Whereverrequiredofapprovedmaketo be fixed to counter with 12no stainless steelsemicircularclipsofsize35mmand 2mm thickness for holding glass etc as perdirectionofEngineerincharge. 3 Providing and fixing display board with logoofapproveddesignandmakeasper drawing enclosed made of acrylic sheet/polycarbonatesheetof2mmthick infacingandaluminumcompositepanel of 3mm thick on remaining sides matchingtheshadeofacrylicsheetwith 2noelectric chokesheetswith2noflour cent lamp 40 watts including caballing upto switch board and fixing at site includingtransportationetc complete as per the direction of Engineer in charge. )size1500x250x75mm. 4 Providing and fixing of customer writing ledge of size 1220 mm long,400 mm wide and 1450 mm height with writing top at a height of 1050 mm including open drawers of 100 mm depth for

Each

Each

Each

Each 47

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

keepingpapersbelowtheworkingtopas per architectural drawing No.B1to B5. Thewritingledgeshallbemadewith 19 mm thick block board (Conforming to IS:1659 BWP Grade ), core of block board construction with frame of 1 st classhardwoodandwellmatchedteak3 plyveneeringwithverticalgrainsorcross bands.The board shall be 1st quality of approved brand Durro/Century /Kitply/Greenply/ Archid including blackingalsoof19mmthickboardoffull height of 1450mm. The ledge shall be laminatedwith1.00mmthickdecorative laminate suede finish &1.0 mm thick brush finish decorative stell laminate as per drawings of make greenlam/Century/Archidlam on all visible surfaces from outside as well as inside and all hidden surfaces shall be painted with white synthetic enamel paint over priming coat of approved quality of Paint/ Primer of. NOTE: Nomenclatureofitemshallsupercede. Providing & Fixing storage cupboard as perdrgs.No.C1toC4.Thecupboardshall befabricatedwithfollowingmaterialand operation: i)19mm thick block board ( IS 1659 BWPGrade ), core of block board constructionwithframeof1stclasshard woodandwellmatched3plyveneering with vertical grains or cross bands,shall be used to prepare the cupboard includingshutter.Theboardshallbe1st quality of approved brand such as Duro/Century/Kitply/Greenply/Archid. ii)Allexposedoutersurfaceofwholecup board shall be laminated and 1.0mm thick brush finish steel decorative laminate wherever required as per drawings.The laminate shall be 1st quality of Greenlam/Century/Archidlam.Inside surface remaining &backside shall be finished with white synthetic enamel paint over priming coat.The paint and primer shall be of approved quality of Nerolac/Berger/Asianbrand. iii)All edges of block board shall be coveredwith19mmwideand3mmthick 2nd class teak wood margin including matchingthesame. 1v) The 19mm thick cupboard shutter shall be fitted with M.Spiano type hinge

48

S. No.

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

of IS marked conforming to IS3818 finished with nickel plating with necessary screws of over all width 50mm.Theshutterofthecupboardshall be provide with Magnetic catcher of heavydutyandbestquality(Triplestrip) horizontal type with multi purpose cabinet look of Godrej equivalent and brushfinishstainlesssteelhandleasper drawing. The work shall include cost of all operations labour&Materials, adhesive nails stainless steel screws etc i/c approved of samples all completed as per direction of Engineer in charge. NoteNomenclature of item shall supersede over the drawing in case of anyambiguitybetweenthetwo. a) Storage cupboard of size 1220 mm x400mmx1050mm containing three boxeswithmagneticcatcherbrushfinish stainless steel handless of suitable size (75mm or 100mm)and multipurpose cabinet lock of Godrej or equivalent in eachboxasperdrawinganddirectionof Engineerincharge. Providing & fixing the 19mm thick block board (conforming to IS; 1659BWP Grade),coreofblockboardconstruction with frame of 1st class hard wood and well matched 3 ply veneering with vertical grains or cross bands of approved brand Duro/Century/Kitply/Greenply/Archidfor making of post office counter drawer, cupboard with necessary fixing arrangement and adhesive , nail, screws including drilling holes etc. all complete asperdirectionofEngineerincharge. Providing and fixing Ultra or equivalent concrete designer tile of approve colour andthickness(22mmorspecifiedbythe manufacturer which ever is more) including 20mm thick base of cement mortar1:4(1cement:4coarsesand)and jointed with neat cement slurry with pigment to match the shade of tiles all completeasperthedirectionofEngineer inCharge. Drilling the bore hole 150mm dia in all kinds of soil by suitable method and lowering the PVC pipe of 110mm dia including removing the casing pipe and hire charges of T&P etc and transportationchargeallcompleteasper

each

Sqm.

100

Sqm.

80

Metre 49

S. No. 9

Description of Items

Quantity

Unit

Rate in words & Figures

Amount

thedirectionofEngineerinCharge. Supplying and filling stone aggregate 20mm nominal size in pit including dressing etc all complete as per the directionofEngineerinCharge. 10 Supplying and filling stone aggregate/gravels 6mm nominal size in pitincludingdressingetcallcompleteas perthedirectionofEngineerinCharge. 11 Supplying and filling coarse sand in pit includingdressingetcallcompleteasper thedirectionofEngineerinCharge. 12 Providing and fixing PVC cap on 110mm diapipes Total

Cum

Cum

2 1

Cum Each

Executive Engineer(C) Postal Civil Division Ambala

50