IKIT-06 Professional Kit

IKIT-06
Professional Kit
Purpose: This kit is designed for engineer to learn the implementation of network data acquisition and control system. Including: I-7520x1 I-7021x1 Wire Connection: 24VDC:

I-7012Dx1 I-7060Dx1

External Power Supply.24VDC I-7520.(R)+Vs, I-7012D.(R)+Vs, I-7021.(R)+Vs, I-7060D.(R)+Vs I-7060D.INCOM External Power Supply.GROUND I-7520.(B)GND, I-7012D.(B)GND, I-7021.(B)GND, I-7060D.(B)GND, I-7060D.RL1 NO, I-7060D.RL2 NO, I-7060D.RL3 NO, I-7060D.RL4 NO

GND:

DATA+:

I-7520.DATA+, I-7021.(Y)DATA+, I-7520.DATA-, I-7021.(G)DATA-,

I-7012D.(Y)DATA+, I-7060D.(Y)DATA+ I-7012D.(G)DATA-, I-7060D.(G)DATA-

DATA-:

Analog Output(+) Connect To Analog Input(+): I-7021.+VOUT, I-7012D.+IN Analog Output(-) Connect To Analog Input(-): I-7021.-VOUT, I-7012D.-IN

Date: Oct-23-1999

Ver: 1.0

Page 1

IKIT-06 Professional Kit

Digital Output(Channel-1) Connect to Digital Input(Channel-1): I-7060D.RL1 COM, I-7060D.IN1 Digital Output(Channel-2) Connect to Digital Input(Channel-2): I-7060D.RL2 COM, I-7060D.IN2 Digital Output(Channel-3) Connect to Digital Input(Channel-3): I-7060D.RL3 COM, I-7060D.IN3 Digital Output(Channel-4) Connect to Digital Input(Channel-4): I-7060D.RL4 COM, I-7060D.IN4

Configuration: I-7012D: Address: 1 Checksum: Disable I-7021: Address: 2 Checksum: Disable I-7060D: Address:3 Checksum: Disable

Baud-Rate: 9600 Range Setting: +/- 10v

Baud-Rate: 9600 Range Setting: 0v ~ 10v

Baud-Rate: 9600

Date: Oct-23-1999

Ver: 1.0

Page 2

IKIT-06 Professional Kit

Demo Program for IKIT-06: The IKIT-06 provides a demo program (with source code) to show how to control or access this IKIT-06 (Professional Kit).

DAM Status

Storage Indicator

Gate Controller

COM Port Setting Active or Stop the program. Exit the program.

DAM Status: Indicates the detailed information of this DAM. COM Port: The user can edit the field the change the COM Port to be used. Active: The user can click on the button to ACTIVE or STOP the program. Exit: The user can click on the button to exit this program. Gate 1 ~ Gate 4: The user can click on the "Gate 1" ~ "Gate 4" to OPEN or CLOSE the Gate.

Date: Oct-23-1999

Ver: 1.0

Page 3

IKIT-06 Professional Kit

High Alarm

Open Gate to prevent the overflow of DAM.

The user must open some GATE to prevent the overflow of DAM.

Low Alarm.

Close some GATE to prevent the empty of

The user must close some GATE to prevent the empty of DAM.

Date: Oct-23-1999

Ver: 1.0

Page 4

IKIT-06 Professional Kit

Hardware Architecture:
I-7021 Analog Output Channel Connect to I-7012D Analog Input Channel I-7520 Module RS-232/RS-485 Converter

I-7060D Digital Output 4 Channels Connect to I-7060D Digital Input 4 Channels.

Software Architecture:

Virtual DAM
Storage
Gate

I-7021 Module Storage Setting

I-7060D Gate Control

I-7060D Reading Gate Status

I-7012D Module Storage Monitor Alarm Report Demo Program Control the Modules

Date: Oct-23-1999

Ver: 1.0

Page 5