Airflotek HEPA/ULPA Filters

http://www.airflotek.com/hepaulpa.html

Clean Room Systems & Fan Filters by AIRFLOTEK 2150 Northmont Parkway - Suite H - Duluth, GA. 30096 Toll Free: 800-581-8524

1 of 4

4/12/2011 2:55 PM

Airflotek HEPA/ULPA Filters

http://www.airflotek.com/hepaulpa.html

Click here to order HEPA Filters On-Line! FILTRA 2000 Series High Capacity HEPA Filter These filters remove a broad range of airborne contaminants including fine dusts, smoke, pollen, soot, bacteria, viruses, asbestos and radioactive particles. They are ideally suited for air conditioning and ventilation for pharmaceutical, photographic, nuclear, optics, electronics, food processing, aerospace, laboratories, hospitals and similar critical applications, as well as for HEPA/ULPA pre-filtration systems in microelectronic and pharmaceutical cleanrooms. The units feature the lowest pressure drop available, extended service life, heavy duty construction and fast, easy installation. Other features and advantages include: Extended service life due to larger filter media surface area (up to 430 sq.ft.). Low filter pressure drop for reduced energy consumption/cost. Air flow capacity of up to 2400 cu.ft per minute (CFM) at an initial resistance of 1.0 inches water gauge. Reduced maintenance and disposal costs due to less-frequent filter changes. Reduced hardware costs due to FILTRA 2000's high airflow capacity. One FILTRA 2000 replaces two standard HEPA filters. Available in a gel seal version for critical applications. Rugged anodized aluminum construction provides high strength, light weight and good corrosion resistance. Filters are individually tested for overall efficiency and pressure drop in accordance with the latest MIL-SPEC revision. Fits into all commonly used filter frames and housings.

2 of 4

4/12/2011 2:55 PM

Airflotek HEPA/ULPA Filters

http://www.airflotek.com/hepaulpa.html

Series 1565 Model Number Dimensions* (in.) Efficiency (0.3 micron DOP) Airflow Capacity (CFM) Pressure Drop (in W.G.) Frame Material Sealant Material Gasket Filter Media Area (sq.ft.) Weight (lbs.)*** Max. Operating Temp** (F) FA1565-01 24 x 12 x 11.5 > 99.99% 900 1.0 Extruded Aluminum Polyurethane Neoprene 175 22 250

Series 1563 FA1563-01 24 x 24 x 11.5 > 99.99% 1500 1.0 Extruded Aluminum Polyurethane Neoprene 215 26 250

Series 1561 FA1561-01

Series 1560 FA1560-01

24 x 24 x 11.5 24 x 24 x 11.5 > 99.99% 2000 1.0 Extruded Aluminum Polyurethane Neoprene 345 35 250 > 99.99% 2400 1.0 Extruded Aluminum Polyurethane Neoprene 430 40 250

* Dimensions do not include gasket ** Limit temperature in continuous service *** Please contact us for shipping weights