KERN
KERN
Laboratory balances
Standard
Internal adjusting (CAL): quick setting of the balances accuracy with internal adjusting weight (motor-driven).
Adjusting program (CAL): for quick setting of the balances accuracy. External adjusting weight required.
*
Verification possible
STANDARD
*
Certificate possible Years Warranty Hours Delivery
Piece counting: reference quantities selectable. Display can be switched from piece to weight. Data interface: RS 232 C, bidirectional, for connection of printer or PC. GLP/ISO record keeping of weighing data with date, time and ident.-no. Only with printers from KERN.
Percentage determination: Displays the deviation from the reference weight (100%) in % instead of grammes.
only with1
* Delivery period
+ 7 days
Metal casing sturdy and stable Carat change over: display can be switched from g / ct. Model d Max KERN ct ct ABJ 804M 0,001 415 ABJ 1204M 0,001 600 ABJ 2204M 0,001 1100 The carat display is verifiable.
80 mm
UNIT: Weighing units can be switched to e.g. nonmetric units at the touch of a key. See balance model Mains adapter: 230 V / 50 Hz. Standard type D, if requested also available in standard UK, AUS or USA.
Test weight incl. Option: DKD-Certicate, KERN 960477 Balance test software "BalanceCal Light" free of charge on the internet, KERN SBD-1.0L
1 Statistics printer,
KERN YKT-01 Capacity display A bar graph shows the current available weighing range Identification number 4 numeric positions, free input Matrix needle printer, no picture, KERN 911-013
Model KERN
Weight. Veric. Min. range value load Max e Min g mg g 83 120 220
ALTERNATIVE Linea- Min. piece rity weight at Verication Certicate p. counting M I mg mg KERN KERN 0,2 0,2 0,2 10 10 10 1
Verification in the factory.
VERIFICABLE
83 120 220
1 1 1
10 10 10
Total balance W x D x H 215 x 315 x 330 mm. Weighing space W x D x H 200 x 170 x 240 mm. Net weight approx. 7 kg. LCD display with digit height 14mm.
PCS: Piece counting with reference 10, 20, 50,100 pieces. UNITS: Further weighing units (only ABS): ct, lb, oz, ozt, dwt, GN. Permissible ambient temperature +10 +30C.
KERN & Sohn GmbH, D-72322 Balingen Postbox 4052 Te l . 0 0 4 9 - [ 0 ] 7 4 3 3 - 9 9 3 3 - 0 Fax 0049-[0]7433-9933-146 e-mail: info@kern-sohn.com I n t e r n e t : w w w. k e r n - s o h n . c o m
ABS ABJ
Measurement data Reproducibility Linearity Stabilisation time (s) Sensity drift /C ABS120-4 0,1mg +/-0,2mg 3 2*10-6 ABS220-4 0,1mg +/-0,2mg 3 2*10-6 ABS80-40,1mg +/-0,2mg 3 2*10-6
Technical Data
Verication data Verication class Verication value Minimum load Verication in the factory possible * * * * * * * * * * * *
Piece counting Minimum weight at piece counting Reference quantity 0,01g 10, 20, 50, 100 0,01g 10, 20, 50, 100 0,01g 10, 20, 50, 100
Ambient conditions Permissible ambient temperature Permissible ambient temperature at verifyed use Permissible ambient humidity 5-40C * max. 80% (not condensating) 5-40C * max. 80% (not condensating) 5-40C * max. 80% (not condensating)
Basic equipment Protective working cover Accumulator Battery-supply Auto-Off Mains adapter Filter steps Type of balance display Digit height of balance display Levelling feet/ level indicator Weighing units * * * * EURO, UK, US, AUS 3 LCD 13mm yes g, mg, ct, mom, Lb, Oz, Ozt, HK, SPorE, tiwAn, mAL, CHinA, dwt, GN * * 100g, E2 * yes * * * * EURO, UK, US, AUS 3 LCD 13mm yes g, mg, ct, mom, Lb, Oz, Ozt, HK, SPorE, tiwAn, mAL, CHinA, dwt, GN * * 200, E2 * yes * * * * EURO, UK, US, AUS 3 LCD 13mm yes g, mg, ct, mom, Lb, Oz, Ozt, HK, SPorE, tiwAn, mAL, CHinA, dwt, GN * * 50g, E2 * yes
Freely programmable weighing units Internal adjusting weight Test weight Recommended test weight Stand-by
Material of draught guard Dimensions of packaging (WxDxH), mm Net weight (kg) Gross weight (kg)
Important notice: - Our balances are not suitable for rooms with danger of explosion or humidity (models with < IP65) - Observe relevant electrical instructions
ABS ABJ
Measurement data Reproducibility Linearity Stabilisation time (s) Sensity drift /C ABJ120-4M 0,1mg +/-0,2mg 3 2*10-6 ABJ220-4M 0,1mg +/-0,2mg 3 2*10-6 ABJ80-4M 0,1mg +/-0,2mg 3 2*10-6
Technical Data
Verication data Verication class Verication value Minimum load Verication in the factory possible I 1mg 0,01g yes I 1mg 0,01g yes I 1mg 0,01g yes
Piece counting Minimum weight at piece counting Reference quantity 0,01g 10, 20, 50, 100 0,01g 10, 20, 50, 100 0,01g 10, 20, 50, 100
Ambient conditions Permissible ambient temperature Permissible ambient temperature at verifyed use Permissible ambient humidity 5-40C 10-30C max. 80% (not condensating) 5-40C 10-30C max. 80% (not condensating) 5-40C 10-30C max. 80% (not condensating)
Basic equipment Protective working cover Accumulator Battery-supply Auto-Off Mains adapter Filter steps Type of balance display Digit height of balance display Levelling feet/ level indicator Weighing units Freely programmable weighing units Internal adjusting weight Test weight Recommended test weight Stand-by * * * * EURO, UK, US, AUS 3 LCD 13mm yes g, ct * yes * * yes * * * * EURO, UK, US, AUS 3 LCD 13mm yes g, ct * yes * * yes * * * * EURO, UK, US, AUS 3 LCD 13mm yes g, ct * yes * * yes
Material of draught guard Dimensions of packaging (WxDxH), mm Net weight (kg) Gross weight (kg)
Important notice: - Our balances are not suitable for rooms with danger of explosion or humidity (models with < IP65) - Observe relevant electrical instructions