Terrace Waterproofing In India, Terrace Waterproofing has always been done with very traditional materials.

Typically systems like brickbat Coba, Lime terracing or the Mud Fuska technique are still very much in vogue. These systems have been offering waterproofing with some insulation against heat. Some of the problems that these systems have are:

y y y y y

Heavy loading on the slab Cracks on the surface, especially in case of brick bat coba Expertise levels of application required for lime terracing/mud fuska not as good as in the olden days Offer more insulation rather than a leak proof or a water-tight system As they age breaking them and re-doing the same system is risky for the slab; cracks caused in the slab increase the problem of leakage

Simple steps can be taken up for new terrace waterproofing in case of both new & existing terrace slabs. Some points for waterproofing contractors have been listed as under, to increase their rate of success, in carrying out the waterproofing jobs on terraces/roofs.

Structural Issues Cause of Leakage: 1. 2. 3. 4. 5. 6. 7. 8. Cracks on the top surface of slab-Injection grouting as required, large cracks repair with URP modified mortar Cracks on the bottom of slab due to excess deflection of slab-Structural consultants opinion must be taken; if leaking can be addressed with a hydrophobic PU foam injection grout Cracks at column supports-Structural consultants opinion must be taken Excess porosity in the slab, bad quality concrete-Resort to Injection grouting Expansion joint in the slab-Polysulphide sealant application with proper detailing Inadequate design of the slab-Structural engineers opinion Spalling of concrete due to corrosion in the slab-Detailed repair with catholic protection & repair materials Cracks due to differential settlement of a building-structural and soil experts opinion must be taken

As the case may be, these must be addressed before waterproofing job is taken up.

Non Structural Issues: 1. 2. 3. 4. 5. 6. 7. Slope not proper-Slope must be provided for water drainage Inadequate rain water pipes-Provide drain water pipes as required Parapet wall not in good condition-Repair parapet masonry/plaster using mortar added with w/p compounds/polymer bonding agents Internal cracks, honeycombs (finished with ordinary mortar), porosity, etc. which cannot be seen by eye-pack using inject grout at the place of leakage from top to bottom Mechanical installations like cooling towers, AC units, etc., on the terrace-Foundations must be examined and repaired if required Aggressive climatic conditions-choose and apply protective coating/WP system Thermal extremes-Provide insulation treatment over WP layer.

Details on the Product:

Newcoat Waterproof coating for terrace Dr. Fixit Newcoat is a heavy-duty; microfibre reinforced acrylic based flexible terrace waterproof coating.It has been tested, approved & used by Housing Development Board of Singapore. Dr.Fixit Newcoat is a three-layer system with coats in different colors ensuring proper buildup of the thickness, making it a reliable waterproofing system.

Features & Benefits Better film thickness-provides 1mm dry film thickness in 3 coats as compared to 300400 microns in 2 coats of other products. High crack bridging ability-bridges cracks upto 2mm width as compared to 0.5mm by other products High tensile strength, tear resistence & bond strength- with cementitious substrates as compared to available products Good resistance-Against UV, Infraded rays and algal & fungal growth Ease in application-can be applied by brush or roller Non toxic, breathable & washable Aesthetic finish-available in pink, green and grey colors for different coats.

y y y y y y y

Torchshield Dr. Fixit Torchshield range of polymer modified bitumen waterproofing membranes are manufactured from rich bitumen and select polymers blended together to obtain excellent heat resistance & cold temperature flexibility. The polymer modified bitumen is then coated on to a dimensionally stable non-woven polyester/fibre glass carrier to obtain high tensile strength, tear and puncture resistance. The Dr. Fixit Torchshield membranes are available in both SBS & APP modified versions. Features & Benefits Self finished, jointless monolithic membranes provide excellent watertight and vapour barrier system High tensile, tear and puncture resistance Can take thermal and structural stresses effectively, without any fatigue Laid quickly and easily; safe and environment friendly Do not undergo early aging, thus provide long life durable membrane Easy melting & fixing, thus saving on usage of expensive gases Available in 1.5, 2, 3 and 4mm thickness APP/SBS modified membrane rolls

y y y y y y y

Areas of application / Application Procedure:

Newcoat All new RCC flat and sloping roofs Existing cementitious waterproofing treatments like brick-bat-coba, concrete screeds, acrylic coatings, etc. Torchshield Re-roofings Roofs with foot traffic Roofs without foot traffic Under tiling Basements Roof gardens Tunnels and subways Hydraulic works/Swimming pools

y y y y y y y y

Pidilite has trained applicators to do the job if required, but the products are otherwise easy to use and can be used by the applicators/contractors etc. otherwise as well.