Burners For Gas Bio, Bioa, Zio, Bic Bica, Bicf, Bocf: T 12.7.2 Edition 9.98
Burners For Gas Bio, Bioa, Zio, Bic Bica, Bicf, Bocf: T 12.7.2 Edition 9.98
BIO
BOA
BIC
BICA
Application
On industrial furnaces and kilns and gasfired installations
in the iron and steel industry,
in the precious-metals, nonferrousmetals and light-alloys sector,
in the glass, heavy-clay and fine-ceramics, pottery or enamel industry,
in the ore, rock and soil sector or
for the plastics, fabric-material or paper
industry,
on thermal afterburning plants
and on dryers and hot air generators.
Features
ZIO
BIO + UVS 8
FLOX is a registered
trademark of
WS-Wrmeprozetechnik GmbH.
Fig. 1
Fig. 2
Fig. 3
L5
L5
L3
S
L3
S
d2
LA
n2
D
h
h
GA
D1
H 30
D
H 30
LA
GA
L6
BIOA, BICA
L2
L6
L1
d3
L4
L1
L4
k2
D2
L2
n3
k3
D3
L5
L3
L3
LA
F
n2
D1
d2
L5
LA
GA
GA
L6
L2
L4
L6
L1
L4
L7
L6
L1
k2
D2
L2
d2
F
n2
GA
k2
D2
LA
L3
d3
L4
L2
L1
D3
k3
ZIO, ZIO..G
Dimensions [inch]
Type Size
Table 4
Max. capacity*
1000 BTU/h
D**
ZIO
40
68
1.57
BIO
50
137
1.97
BIOA 65
307
2.56
BIO
65
307
2.56
BIO
80
512
3.23
BIO 100
785
4.02
BIO 125
1092
5.00
BIO 140
1536
5.51
ZIO 165
2150
6.65
ZIO 200
3413
7.64
BIC
50 51, 102, 119 2.17
BICA 65 34, 85,171, 205, 239 2.72
BIC
65 34, 85,171, 205, 239 2.72
BICF, BOCF 65 in preparation
BIC
80
358
3.39
BICF, BOCF 80 in preparation
BIC 100 307, 546, 614, 682 4.09
BICF, BOCF 100 in preparation
BIC 140 921, 1092, 1228 5.59
BICF, BOCF 140 in preparation
Dimensions [inch]
D1** GA
LA
H h
NPT 3/8 NPT 3/4 1.81 1.50
NPT 1/2 NPT 11/2 1.97 1.50
NPT 1/2 1.89 1.97 1.73
NPT 3/4 NPT 11/2 2.44 1.89
NPT 3/4 NPT 2 4.41 2.17
NPT 1 NPT 2 3.94 2.36
NPT 11/2 ANSI 21/2 5.31 2.87
NPT 11/2 ANSI 3 5.91 3.15
NPT 11/2 ANSI 4 8.27
NPT 2 ANSI 6 8.66
2.99 NPT 1/2 NPT 11/2 1.97 1.50
3.54 NPT 1/2 1.89 1.97 1.73
3.54 NPT 3/4 NPT 11/2 2.44 1.89
S
0.24
0.47
0.63
0.47
0.55
0.63
0.71
0.71
0.39
0.39
0.47
0.63
0.47
L3
1.73
3.03
3.74
2.87
3.54
4.06
4.72
5.11
5.91
8.66
2.87
3.74
2.87
L4
3.90
5.87
6.69
6.14
6.77
7.28
10.08
11.02
14.17
18.46
5.87
6.69
6.14
L5
7.52
9.25
9.96
9.65
10.63
11.22
13.98
14.96
9.25
9.96
9.65
L6 D2 k2 d2
3.03 3.94 3.15 0.35
5.00 7.13 5.94 0.47
5.87 7.68 6.50 0.51
5.00 7.68 6.50 0.47
5.51 9.45 8.27 0.55
6.02 9.45 7.84 0.55
4.41 10.63 9.45 0.55
9.17 11.81 10.43 0.55
9.06 11.22 9.45 0.55
13.39 13.00 11.61 0.87
5.00 7.23 5.94 0.47
5.87 7.68 6.50 0.51
5.00 7.68 6.50 0.47
n2
F
0.16
2.95
0.16
2.95
0.16
3.46
0.16
3.74
0.16
4.33
0.16
4.72
0.16
5.71
0.16
6.30
0.16 8.66
0.31 10.04
0.16
2.95
0.16
3.46
0.16
3.74
D3
7.23
7.84
8.66
11.22
****
k3 d3
5.71 0.71
6.23 0.71
7.09 0.71
9.45 0.87
n3
0.16
0.31
0.31
0.31
Weight
***
LBS
6.61
8.16
11.02
14.33
22.05
24.25
55.12
61.73
52.91
81.57
8.16
11.02
14.33
4.41 2.17 0.55 3.54 6.77 10.63 5.51 9.45 8.27 0.55 0.16
4.33
20.94
5.00 NPT 1
3.94 2.36 0.63 4.06 7.28 11.22 6.02 9.45 7.84 0.55 0.16
4.72
24.25
NPT 2
6.61 NPT 11/2 ANSI 3 5.91 3.15 0.71 5.12 11.02 14.96 9.17 11.81 10.43 0.55 0.16
*Cold air connection, open flame, = 1,1 / **In the case of deviations from standard length: D (BIO, ZIO) or D1 (BIC) approx. 0.39 in (10 mm) larger due to weld seam.
***Standard overall length / ****Air connection to DIN 2501 PN 16
Dimensions [mm]
Type
Size
Table 4
Max. capacity*
Dimensions [mm]
kW
D** D1** GA
ZIO
40
20
40 NPT 3/8
BIO
50
40
50 NPT 1/2
BIOA
65
90
65 NPT 1/2
BIO
65
90
65 NPT 3/4
BIO
80
150
82 NPT 3/4
BIO
100
230
102 NPT 1
BIO
125
320
127 NPT 11/2
BIO
140
450
140 NPT 11/2
ZIO
165
630
169 NPT 11/2
ZIO
200
1000
194 NPT 2
BIC
50
15, 30, 35
55 76 NPT 1/2
BICA
65 10, 25, 50, 60, 70 69 90 NPT 1/2
BIC
65 10, 25, 50, 60, 70 69 90 NPT 3/4
BICF, BOCF 65 in preparation
BIC
80
105
86 115 NPT 3/4
BICF, BOCF 80 in preparation
BIC
100 90, 160, 180, 200 104 127 NPT 1
BICF, BOCF 100 in preparation
BIC
140
270, 320, 360 142 168 NPT 11/2
BICF, BOCF 140 in preparation
LA
H
NPT 3/4 46
NPT 11/2 50
48
50
NPT 11/2 62
NPT 2 112
NPT 2 100
ANSI 21/2 135
ANSI 3 150
ANSI 4 210
ANSI 6 220
NPT 11/2 50
48
50
NPT 11/2 62
L3
44
73
95
73
90
103
120
130
150
220
73
95
73
L4
99
149
170
156
172
185
256
280
360
469
149
170
156
L5
191
235
253
245
270
285
355
380
235
253
245
L6
77
127
149
127
140
153
212
233
230
340
127
149
127
Weight ***
D2
100
181
195
195
240
240
270
300
285
330
181
195
195
k2
80
151
165
165
210
200
240
265
240
295
151
165
165
d2
9
12
13
12
14
14
14
14
14
22
12
13
12
n2 F
4
75
4
75
4
88
4
95
4 110
4 120
4 145
4 160
4 220
8 255
4
75
4
88
4
95
D3
185
200
220
285
****
k3 d3 n3
145 18 4
160 18 8
180 18 8
240 22 8
h
38
38
44
48
55
60
73
80
38
44
48
S
6
12
16
12
14
16
18
18
10
10
12
16
12
kg
3
3,7
5
6,5
10
11
25
28
24
37
3,7
5
6,5
NPT 2
112 55
14
110
NPT 2
100 60
120
11
ANSI 3
150 80
28
9,5
*Cold air connection, open flame, = 1,1 / **In the case of deviations from standard length: D (BIO, ZIO) or D1 (BIC) approx. 0.39 in (10 mm) larger due to weld seam.
***Standard overall length / ****Air connection to DIN 2501 PN 16
L7
B1
Type
Size
E3 W1
BIO/C
BIO/C
ZIO
ZIO
N
B1
in
mm in mm
1.54 39
1.77 45
2.17 55
2.36 60
100
140
165
200
Dimensions
E3
W1
in mm
0.12 3
36
0.12 3
42
Table 5
L7
in
7.68
10.87
11.42
15.75
g*
mm
195
276
290
400
NPT 1/4
NPT 3/8
NPT 3/8
NPT 3/8
BI..G
Dimensionsforburnerswith
separatelow-firerate supply for gas and air
Type
L7
Size
B
E1
W1
E2
W2
BIO/C
BIO/C
BIO/C
BIO/C
ZIO
ZIO
80
100
125
140
165
200
B
in
mm
2.24 57
2.24 57
2.13 54
2.48 63
Dimensions
C
E1
E2
L7
in mm
in
mm in
mm
in
mm
2.13 54 0.28
7 0.39 10 6.97 177
2.13 54 0.28
7 0.39 10 7.48 190
2.56 65 0.35
9 0.31
8 10.28 261
2.44 62 0.63 16 0.71 18 10.87 276
Gas connection: NPT 1/4 / Gas pressure: 12 16 "WC (30 40 mbar) / Air connection: NPT 3/8
if used with separate ZMI 16 pilot burner: NPT 1/2 / Air pressure: 12 16 "WC (30 40 mbar)
BI..L
BIC..L
Burner tubes and tube extensions:
Length graded in steps of 3.94 inch (100
mm), max. length 26.24 ft (8000 mm),
components made of normal steel; also
available made of high-temperature or corrosion-resistant steel on request.
Table 6
W1
36
36
30
42
W2
45
45
30
45
BIC(A)
Used preferably as impulse burner with
moderate to high outlet velocity 262 to 492 ft/s
(80 to 150 m/s) on industrial furnaces and
kilns on which temperature regulation is
performed by an impulse system.
Selection
Type (Table 7)
BIO(A), ZIO
Burner with steel tube
Optimum combustion is ensured either by a
burner tile integrated within the refractory
brickwork or by a high-temperatureresistant burner additional tube or steel
tubes if used in combustion chambers in
the low and moderate temperature range.
BICF
The burner operates in flame mode up to a
furnace or kiln temperature of 1562F
(850C). Thereafter, it switches over to flameless oxidation on the basis of the FLOX
principle. This minimises the nitrous oxide
values.
BOCF
Can be used in FLOX mode for furnace and
kiln temperatures above 1562F (850C).
BICF and BOCF are particularly well-suited
to installations with pre-heated combustion air.
Selection
Table 7
Type
Housing
BIO
BIOA
BIC
BICA
BICF
BOCF
ZIO
GG 25
AlSi
GG 25
AlSi
GG 25
GG 25
ST
Operation
Air temp.
F
68 842
68 392
68 842
68 392
68 842
68 842
68 842
Flame
Flame
Flame
Flame
Flame/FLOX
FLOX
Flame
C
20 450
20 200
20 450
20 200
20 450
20 450
20 450
Furnace temp.
F
C
122 2912 50 1600
122 2912 50 1600
122 2642 50 1450
122 2642 50 1450
122 2642 50 1450
1562 2642 850 1450
122 2912 50 1600
Burner size
Burner head
[%]
200
180
96
160
Capacity
90
140
Gas pressure
85
120
80
100
32 100 200 300 400 500 600 700 800
75
[F]
[F]
0
0
Fig. 8
Fig. 9
Capacity/performance data
BIO(A), BIC(A), BICF, BOCF, ZIO for natural gas
Type
ZIO 40 2)
BIO 50
BIO 50
BIO(A) 65
BIO(A) 65
BIO 65
BIO 80
BIO 80
BIO 80
BIO 100
BIO 100
BIO 100
BIO 125 7)
BIO 125 7)
BIO 140
BIO 140
BIO 140
ZIO 165
ZIO 165
ZIO 165
ZIO 200
ZIO 200
BIC 50
BIC 50
BIC 50
BIC 50
BIC 50
BIC(A) 65
BIC(A) 65
BIC(A) 65
BIC(A) 65
BIC(A) 65
BIC(A) 65
BIC(A) 65
BIC(A) 65
BICF, BOCF 65
BIC 80
BICF, BOCF 80
BIC 100
BIC 100
BIC 100
BIC 100
BIC 100
BIC 100
BICF, BOCF 100
BIC 140
BIC 140 7)
BIC 140
BIC 140 7)
BIC 140
BIC 140 7)
BICF, BOCF 140
68
20
H
A
136
40
R
A
136
40
H
C
307
90
R
E (A)
307
90
H
E (A)
307
90
K
E
512
150
R
E
512
150
H
E
512
150
K
E
785
230
R
E
785
230
H
E
785
230
K
E
1092
320
R
D
1092
320
H
D
1535
450
R
E
1535
450
H
E
1535
450
K
E
2150
630
R
D
2150
630
H
D
2150
630
K
D
3412 1000
R
A
3412 1000
H
A
B020
B028
B028
A035
A035
B020S
B025S
B033
B033
B040
B040
A048
A048
in preparation
B040
in preparation
B050
B050
B065
B065
A082
A082
in preparation
B070
B085
A120
in preparation
Table 10
Flame length
4), 8)
inch
cm
5.91 7.84
15 20
7.84 8.66 20 22
7.09 13.8 18 35
7.84 9.06 20 23
11.81 21.65 30 55
7.84 5.75 20 40
23.62 35.43 60 90
7.84 21.65 20 55
5.75 39.37 40 100
5.75 35.43 40 90
27.56 53.15 70 135
13.78 5.75 35 40
23.62 47.24 60 120
3.94 19.69
27.56 47.24
3.94 23.62
43.31 94.49
Orifice plate
Gas supply pressure
p
max. 1)
"WC mbar
"WC
mbar
10
25
10.8
27
14
35
3 (-) 7,5 (-) 16 (10.8) 40 (27)
3 (-) 7,5 (-) 10.8 (7.2) 27 (18)
3
7,5
21.2
53
3.8
9,5
9.6
24
3.8
9,5
8.8
22
3.8
9,5
17.2
43
3.6
9
12
30
3.6
9
9.2
23
3.6
9
16
40
12
30
12.8
32
3.2
8
13.2
33
3.2
8
16
40
3.2
8
23.2
58
10 50
13.2
33
70 120
16
40
12.4
31
10 60
10.4
26
110 240
8
20
51
102
102
119
119
34
85
171
171
205
205
239
239
15
30
30
35
35
10
25
50
50
60
60
70
70
H..R
R
H
R
H
H..R
H..R
R
H
R
H
R
H
A
C
C
C
C
- (A)
- (A)
E (A)
E (A)
E (A)
E (A)
E (A)
E (A)
3.94 5.91
3.94 6.30
4.72 7.84
5.91 7.84
6.30 8.66
4.33 8.66
4.33 8.66
7.09 10.63
4.33 8.66
6.69 9.84
7.84 12.99
6.69 9.84
9.06 5.75
10 15
10 16
12 20
15 20
16 22
11 22
11 22
18 27
11 22
17 25
20 33
17 25
23 40
- (-)
- (-)
- (-)
- (-)
2 (-)
5 (-)
2 (-)
5 (-)
3.2 (-) 8 (-)
3.2 (-) 8 (-)
4.4 (-) 11 (-)
4.4 (-) 11 (-)
358
105
11.81 5.75
30 40
307
307
546
546
614
614
90
90
160
160
180
180
R
H
R
H
R
H
E
E
E
E
E
E
5.91 13.78
13.78 19.69
9.84 17.72
17.72 25.59
11.81 19.69
17.72 23.62
15 35
35 50
25 45
45 65
30 50
45 60
921
921
1091
1091
1228
1228
270
270
320
320
360
360
R
H
R
H
R
H
E
E
E
E
E
E
7.84 5.75
19.69 23.62
5.75 23.62
5.75 31.50
11.81 31.50
5.75 35.43
20 40
50 60
40 60
40 80
30 80
40 90
Velocity
3), 6)
ft/s
m/s
164
50
49
15
213
65
66
20
230
70
66
20
66
20
230
70
66
20
82
25
197
60
230
70
230
70
66
20
262
80
82
25
11.2
13.2
5.2
10.4
4.8
- (2.8)
- (5.6)
13 (13)
7.2 (7.2)
12.8 (14)
8.8 (6)
16.4 (16)
10 (7.2)
28
33
13
26
12
- (7)
- (14)
32 (32)
18 (18)
32 (35)
22 (15)
41 (40)
25 (18)
12
12
7.2
10
7.2
- (2.8)
- (5.6)
13 (10)
7.2 (8)
11.2 (8)
8 (8)
11.2 (12)
7.6 (7.2)
30
30
18
25
18
- (7)
- (14)
32 (25)
18 (20)
28 (20)
20 (20)
28 (30)
19 (18)
328
361
328
262
246
213
312
426
394
344
328
279
262
100
110
100
80
75
65
95
130
120
105
100
85
80
7,5
16
40
14
35
590
180
1
1
2.8
2.8
3.4
3.4
2,5
2,5
7
7
8,5
8,5
6
4.8
12
11.2
12
9.6
15
12
30
28
30
24
5.6
0.4
12
7.2
10
7.2
14
10
30
18
25
18
328
312
344
328
246
230
100
95
105
100
75
70
1.8
1.8
2.6
2.6
3.2
3.2
4,5
4,5
6,5
6,5
8
8
12
11.6
12.8
12
12
12
30
29
32
30
30
30
8.8
8
9.2
8
5.6
8
22
20
23
20
14
20
508
476
410
394
230
213
155
145
125
120
70
65
Ionisation current: 5 35 A, depending on set burner capacity and flame amplifier used.
Values in parenthesis for BIOA, BICA. In addition, the burner heads feature code numbers which
allow a direct assignment to the pressure loss diagrams.
1) Natural gas L, cold-air operation, open flame, = 1.1, Hu = 8.9 kWh/m3, Lo = 8.4 m3/m3, = 0.8 kg/m3.
In the case of operation with natural gas H, convert as a function of the kW burner capacity in order to determine the gas flow rate.
2) ZIO 40 is an unregulated pilot burner.
3) Calculated on the basis of flame temperature 1600C R and K head, 1500C H head, referred to
max. burner capacity.
4) BIO measured with burner tile, as of burner tile front edge, opening 6 with R head, cylindrical
with H head, length 3 x D in each case.
5) Connection ratings are guideline values. Higher capacities are possible in the case of various
burners (on request).
6) BIO calculated for burner tiles as specified in 4). It is possible to increase the flow velocity to the
values of the BIC burners by reducing the outlet diameter of the burner tile.
7) Suitable only for cold air.
8) The flame diameter is approx. 1-2 x burner tube diameter or burner tile outlet diameter.
Flame shape
Code letter Flame shape
R
H
K****
normal
long
flat
Table 11
Regulating range*
continuous constant air flow rate high/low
1:10
1:3
>1:10
1:10
1:4
1:10
>1:10
Low-fire rate
>1.05
>1.3
>1.05
**
0.8 1.3
0.6 1.5
0.9 1.2
Furnace temp.
F
C
122 2462
50 1350
932 2913 500 1600
122 2462
50 1350
Air temp.***
F
C
68 482 20 250
68 842 20 450
68 752 20 400
Type of gas
Table 12
Code letter
Type of gas
B
G
M
D
BTU/ft3
773 1160
2416 2802
2416 3382
290 483
kWh/m3(n)
8 12
25 29
25 35
35
Variant
Table 13
Code letter
Version
Regulating range
continuous high/low
G*
L
R
Low-fire rate
Furnace temp.
Capacity
1000
BTU/h kW
F
C
up to 1:100 34 51 10 15 > 1.05 122 2462 50 1350
up to 1:650 ~ 5
~ 1,5 > 1.05 122 2912 50 1600
1:10
1:10
1:10
Air temp.
F
68 482
68 842
68 482
* Burners may not be operated at low-fire rate for longer than 6 hours since this would otherwise involve the risk of overheating and failure.
Burner length
BIO(A), ZIO in the burner tile (Table 18)
The total burner length measured from the
burner mounting flange is equal to the length
of the burner tube (L1). The position of the
burner head must be selected such that the
burner head projects into the burner tile:
L2 = W - L10 (Fig. 14).
Depending on the burner head, the burner
tube length can be calculated as follows:
R, K head: L1 = L2 + 0.59 inch (15 mm),
H head:
L1 = L2 + 2.56 inch (65 mm).
yyyy
,,,,
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
L1
,,,,
yyyy
yyyy
,,,,
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
yyyy
,,,,
,,,,
yyyy
W
L1
L2
L2
Fig. 16
BIC(A), BICF, BOCF (Fig. 17)
The total burner insertion depth into the furnace or kiln is dependant on the length of
the burner extension made of steel and the
ceramic tube length (Table 29). These lengths
should be selected so that the burner nozzle
ends within the area of the inside of the furnace or kiln wall or is max. 2 inch (50 mm)
behind it.
L10
Fig. 14
,,
in
4.53
4.53
6.50
6.50
8.46
10.43
10.43
12.40
mm
115
115
165
165
215
265
265
315
L1-2
Table 15
Additional
tube length
H head
R head
in
mm
in
mm
1.97
50 3.94 100
1.97
50 3.94 100
3.94 100 5.90 150
3.94 100 5.90 150
5.90 150 7.84 200
7.84 200 9.84 250
7.84 200 9.84 250
9.84 250 11.81 300
L1
L8
2"
50mm
Fig. 17
C
20 250
20 450
20 25
Fig. 19
Fig. 20
Fig. 21
Fig. 22
yyyyyyyyy
,,,,,,,,,
,,,,,,,,,
yyyyyyyyy
,,,,,,,,,
yyyyyyyyy
,,,,,,,,,
yyyyyyyyy
,,,,,,
yyyyyy
,,,,,,
yyyyyy
,,,,,,
yyyyyy
,,,,,,
yyyyyy
,,,,,,
yyyyyy
,,,,,,
yyyyyy
,,,,,,
yyyyyy
Fig. 23
,,,,,,
yyyyyy
,,,,,,
yyyyyy
yyyyyy
,,,,,,
,,,,,,
yyyyyy
,,,,,,
yyyyyy
,,,,,,
yyyyyy
,,,,,,
yyyyyy
yyyyy
,,,,,
,,,,,
yyyyy
,,,,,
yyyyy
,,,,,
yyyyy
,,,,,
yyyyy
Burner size
Type of tile
50
65
65
80
80
100
100
100
125
140
140
165
165
200
Fig.
19, 20, 21
19, 20, 21
22
19, 20, 21
22
19, 20, 21
22
22
19, 20, 21
19, 20, 21
22
19, 20, 21
22
19, 20, 21
Radiant tube
heating*
24 Burner additional
tube with
secondary air holes
Air heating
25 Burner additional
High/Low
tube with secondary High/Low/Off
air holes, combustion Continuous
chamber
20 Cylindrical
21 Diameter-restricted
22 Flat flame
quarl
23 Cylindrical
yyyy
,,,,
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
Regulation
Head Max.
Remarks
type capacity
High/Low
R
100% Only cold-air operation recomContinuous
mended, otherwise the nitrous
oxide values may become excessive
High/Low
R, H 100% Normal to moderate
High/Low/Off
flow velocity
Continuous
High/Low
R, H
80% Moderate to high velocity
High/Low/Off
High/Low
High/Low/Off
Continuous
High/Low
High/Low/Off
Continuous
High/Low
High/Low/Off
Continuous
100%
100%
100%
100%
* If the burners are used in radiant tubes or small combustion chambers, it is advisable to conduct a test under operating conditions. The burnersmust be sealed via the furnace or kiln flange on the installation or at the burner tile so as to prevent hot exhaust gases flowing back.
yyyyyy
,,,,,,
,,,,,,
yyyyyy
,,,,,,
yyyyyy
,,,,,,
yyyyyy
,,,,,,
yyyyyy
yyyyyyyyy
,,,,,,,,,
,,,,,,,,,
yyyyyyyyy
,,,,,,,,,
yyyyyyyyy
,,,,,,,,,
yyyyyyyyy
,,,,,,,,,
yyyyyyyyy
,,,,,,,,,
yyyyyyyyy
,,,,,,,,,
yyyyyyyyy
,,,,
,yy,yyyy
y,y,
,,,,
,,,,
yyyy
y,y,yyyy
,,,,y,y,y,
yyyy
,,,,
y,y,yyyy
,,,,
y,
,,,,
yyyy
y,y,yyyy
,,,,y,y,y,
yyyy
,,,,
y,y,yyyy
,,,,
yyyy
y,y,
,,,,
y,y,yyyy
,,,,
yyyy
,,,,y,y,y,
yyyy
,,,,
y,y,y,yyyy
,,,,
y,
,,,,
yyyy
y,y,yyyy
,,,,y,y,
yyyy
,,,,
y,yyyy
,,,,y,y,
y,yyyy
Burner tile shape and flame shape are combined, depending on type of application, in
order to achieve optimum function.
Fig.
yyyyyyyyyyyyyyyy
,,,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,,
yyyyyyyyyyyyyyyy
,,,,,,,,,,,,,,,,
yyyyyyyyyyyyyyyy
,,,,,,,,,,,,,,,,
yyyyyyyyyyyyyyyy
,,,,,,,,,,,,,,,,
yyyyyyyyyyyyyyyy
,,,,,,,,,,,,,,,,
yyyyyyyyyyyyyyyy
,,,,,,,,,,,,,,,,
yyyyyyyyyyyyyyyy
,,,,,,,,,,,,,,,,
yyyyyyyyyyyyyyyy
yyyy
,,,,
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
R
R, H
K
R, H
K
R, H
K
K
R, H
R, H
K
R, H
K
R, H
Type of
application
Industrial furnaces
and kilns, open
firing installations
Industrial furnaces
and kilns, open
firing installations
Industrial furnaces
and kilns, open
firing installations
Industrial furnaces
and kilns, open
firing installations
Tangentially fired
crucibles
Fig. 24
,,,,
yyyy
yyyy
,,,,
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
,,,,
yyyy
Flame shape
B, M, G, D
B, M, G, D
B, M, G, D
B, M, G
B, M, G
B, M, G, D
D
B, M, G
B, M, G
B, M, G, D
B, M, G, D
B, M, G, D
B, M, G, D
B, M, G, D
Table 18
Type of gas
Fig. 25
,
0.2"
5mm
L8
D4
L9
2"
50mm
P 0.6"
15mm
Fig. 26
Fig. 27
Furnace/kiln temp.
F
C **
2282
1250
2462
1350
2462
1350
2642
1450
Air temp.
F
C
68 302 20 150
68 482 20 250
68 482 20 250
68 842 20 450
Table 28
Burner head
Type of control
R
H
R
H
1), 3)
1), 2), 3)
1), 3)
1), 2), 3)
Table 29
102
30 B
1.10
28
119
35 A
1.38
35
34
10 B, S*
0.79
20
85
25 B, S*
0.98
25
170
50 B
1.30
33
170
50 B
1.30
33
204
60 B
1.57
40
204
60 B
1.57
40
238
70 A
1.89
48
358
105 B
1.57
40
307
90 B
1.97
50
307
90 B
1.97
50
546
160 B
2.56
65
546
160 B
2.56
65
614
180 A
3.23
82
921
270 B
2.76
70
1092
320 B
3.35
85
1228
360 A
4.72 120
Material
CRYSTAR-D
CarSIK-GG
****
Modifications
The following modifications are possible:
Secondary air connections for preventing condensation in the burner.
Burner tubes on BIO(A) with secondary air
holes and/or of stainless steel design in
conjunction with burner additional tubes for use
in radiant tubes and combustion chambers
(Fig. 24 + 25).
10
Valves for gas and air mounted on the burner and ignition transformer and automatic
burner control as complete unit.
Modified BIC burners in sizes 50-100 in
conjunction with a pot housing SLG as
pot burner for roof firing of tunnel kilns in the
ceramics industry (Fig. 30). The performance data corresponds to that for the
BIC(A) burners.
Pot burner
Type code
RSG 140 /100 -50
Type
Secondary air tube [mm] = 100, 140
Burner size = 65, 100
Length of the secondary air housing L11 [mm] =
0, 50, 100, 150
SLG
Fig. 30
2000
1800
1600
1400
[F]
[C]
Flame temperature
3600
3200
2800
2400
L11
1200
1000
800
2000
1600
600
1200
400
800
200
400
32
12
8 10 12 14 16 18 20
Fig. 31
RSG
Fig. 32
Capacity/performance data BIC(A) burners with annular excess air burner housing RSG
max.
max.
Type
Housing
Capacity Secondary air
1000
BTU/h kW ft3/h m3/h
BIC(A) 65 RSG 100/65-0
170
50 7768 220
BIC(A) 65 RSG 100/65-0
204
60 14124 400
BIC 100 RSG 140/100-0 682 200 14124 400
Table 33
TGI, TZI
We certify that the burner meets the requirements of the applicable Directives and
Standards with a "Manufacturers Declaration" as defined by the Machinery Directive (89/392/EEC), Annex II B.
R, K (450C)
600
500
400
H (450C)
300
200
R, K (20C)
H (20C)
100
70
FLOX (450C)
50
10
50
100
Capacity [%]
Fig. 34
Type code
BIC
65
G*
(70)
Z*
Type
BIO, BIOA, ZIO, BIC, BICA, BICF, BOCF
Burner size
ZIO 40
* When "without", this letter is dropped, i.e. the next one moves up.
Type code
Type
TSC 100
CRYSTAR-D
Kromschroder Inc.
1691-H Georgetown Rd.
Hudson, OH 44236
Phone 3 30-3 42-05 95
Fax
3 30-3 42-05 96
www.kromschroder.com
KSINCUSA@ad.com
TSC
We reserve
the right to make
technical changes
designed to improve
our products
without prior notice.
12