Professional Documents
Culture Documents
Trend IQ 3 Overview
Trend IQ 3 Overview
IQ 3 Controller Overview
Course Objective
Honeywell
Introduction Hardware Ethernet Network Configuration Setup Portable Display Panel Supervisor Software Interface Field devices
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
INTRODUCTION
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
Ethernet TCP/IP is a suite of protocols Original intent of development was to have multiple routes which could be used by computers communicating with each other. Developed by the US Department of Defence in 1973, mainly for the purpose of interconnecting different brands of computers. TCP/IP is a non- proprietary product and is now the accepted communication protocol on the Internet For more details on TCP/IP, visit the following website:
http://www.cisco.com
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
Demand for simple and fast information access WWW becoming de-facto standard for B2B connectivity Total data connectivity (http, xml,.etc) Distribution of live information (mobile devices etc.) Open solution with lowest proprietary content (harness the IT and Web world of solutions) Increasing regulations Energy issues (Part L, Carbon taxes, cost volatility, etc.) requiring control solutions Changing building infrastructure On-line buildings linked directly to the Internet Flood-wired Ethernet networks becoming standard inside buildings
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
IT / Web-based technology is widely implemented all over the world. Most widely used OPEN protocol network. Even more popular than BACnet, LONwork, MODbus, etc. Make use of building or structure existing IT backbone setup. Reduce cost and installation works. The smartest and best cost means of liberating field data for both operators and other information systems. Move away from expensive but slow Lease Line. Move away from a typical Building Management System network. No need of expensive software or specialised hardware for remote access. Using commonly available web-browser for access such as INTERNET EXPLORER
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
Web enabled: Makes it easy to access and control the building, in real-time, from a standard Web browser Managers and operators can remotely; find out whats going on in their buildings, take rapid action to help manage costs, correct comfort problems, etc.
WWW
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
IT level
Use IP networking as far down the system as is economically viable Build native embedded web-serving capability as far down the system as is economically viable And ultimatelyManagement and IT level communications in IT compatible formats
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
Uses Ethernet and TCP/IP networking technologies, IT network enable, accessible from anywhere. Built- webBuilt-in web-server, no proprietary software required to access controller or view user specified web pages Modular Hardware Extendibility and Flexibility, up to 96 Input / Output points Flexible number of strategy modules Controllers optimised to application DIN Rail Mounted Backward compatibility with predecessor controllers IQ2 series of controller
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
Inputs & Outputs 6 Analogue outputs & 6 Universal inputs 6 Analogue outputs & 10 Universal inputs only 6 Analogue outputs & 10 Universal inputs Plus up to 80 extra points via I/O expansion modules
IQ3xcite/96
10
N O V A R
I N T E L L I G E N T
File Number
Honeywell
Modules is connected via a rigid connector or Belden cable 3084A for up to 30 metres Maximum up to 15 boards can be fitted, limited to an additional of 80 Input / Output points The following module board are available :
Note Xcite 16DI module and Xcite 8DI module can accept both voltage free contact and 24 Vac supply.
11
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
3 Levels Hierarchy
Actuators
12
B U I L D I N G
S Y S T E M S
File Number
Ethernet Platform
BuiltBuilt-in microprocessor, intelligence in every controller. MCF 5272 microprocessor, speed 66MHz Memory 16 Mbytes SDRAM & 8 Mbytes Flash Built-in Real Time Clock BuiltNo replaceable fuse required. Protected by a self resetting thermal solid state breaker Auto-restart capabilities AutoPeer-toPeer-to-Peer Controller Share Global Data among the Ethernet network
IQ 3XCITE
IQ 3XCITE
Network or stand-alone operation stand Ideal for individual or small equipment application for stand-alone operation stand Able to support up to more than 13,400 controllers in a single network, sufficient for large building services or application.
N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S
13
File Number
Fully programmable to suit different application Proportional Integral Derivatives Control Boolean Algebraic & Logic Module Function Modules Optimisation Start/Stop Control Plant Rotation / Duty Cycling Sequential Control Etc. Optional Portable Display Panel Smart Display Panel (SDU) IQVIEW (Network Display Panel)
IQVIEW
14
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Comply to Different Standards UL Listed Standard (24 Vac) EN Standards (100 230Vac) BSI Standard : BS EN ISO 9001:2000 CE Certified Electromagnetic Compatibility Directive (89/336/EEC) Low Voltage Directive (73123/EEC)
15
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Faster Network speed Ethernet 10 Base T Network Network baud rate up to 10 Mbytes/sec No memory battery back-up required. back All strategy and data stored in non-volatile memory nonBuiltBuilt-in Web browser Capability
16
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Individual Time Scheduling capabilities Allow more than 5 time zones per controller Unlimited number of switching per 24 hours duration period Incorporate override facilities for special events
Enhance security features More than 6 user can be set up Maximum up to 99 access level Support alphanumeric password up to 30 characters Automatic sign-off capabilities
17
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Points in alarms will be highlighted in web pages Retransmit alarm to Supervisor software via IP address Retransmit alarm via SMTP to email server address
Power Indicator (Status & Fault) Watchdog Indicator (Software & RAM fault) Input / Output Bus Indicator (I/O Module Bus fault) Input / Output Terminal Indicator Network Transmission Indicator
18
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
HARDWARE
19
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
Optional Battery Card If an IQ 3Xcite Controller is set up to be a time master, an optional battery card is recommended to be installed. The battery shall help to maintain the Real Time Clock (RTC) for several years. However it need to be replaced every 5 years.
N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S
20
File Number
Honeywell
21
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
22
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
23
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
24
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
Power Supply
25
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
26
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
27
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
28
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
End-ofEnd-of-Line Terminator
29
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
30
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
31
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
32
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
24 Vdc Power Supply (max 1.3 A) 24 Vdc Power Supply (max 2.5 A) 24 Vdc Power Supply (max 5 A)
33
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
ETHERNET NETWORKS
34
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Ethernet Networks
TREND Ethernet Networks
IQ 3 series controller
Honeywell
SUPERVISOR
Uses Ethernet and TCP/IP networking technologies, IT network enable, accessible from anywhere.
WAN
35
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Ethernet Networks
Physical Medium
Network Cable
Honeywell
10 Base T Use a Physical STAR Topology, but uses a Logical BUS Topology for communication Device attach to HUB using a CAT3 or higher twisted pair cable HUBs & devices have LINK LED which indicates the segment is healthy Expand the network by daisy chaining HUB, Other similar networks in this style 100 Base T CAT5 (100Mbytes/s) 1000 Base T CAT6 (1Gbytes/s)
36
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Ethernet Networks
Physical Medium
Network Cable
Types of cable (Ethernet)
Honeywell
37
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Ethernet Networks
Physical Medium
TREND Ethernet Devices (Industrial Rate)
Honeywell
Industrial rate network equipment is designed to operate in harsh industrial environmental. DIN rail mounting and suitable for use in controller enclosure
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Web Pages Configuration
Introduction
Honeywell
IQ 3 controllers incorporate a web server which can deliver user-specific pages to a usercomputer running standard internet browser software.
IQ 3XCITE
39
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Web Pages Configuration
Welcome Page
Honeywell
IQ 3 controllers incorporate a web server which can deliver user-specific pages to a usercomputer running standard internet browser software.
40
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Web Pages Configuration
Module Page
Honeywell
Module page options allows the user to see the controller strategy. Values can be changed with the keyboard and sent with eitherEnter or one of the adjustment icons.
41
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Web Pages Configuration
Plant GraphIQs
Honeywell
42
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Web Pages Configuration
Create GraphIQs
Honeywell
43
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Security Configuration
Default System Guest
Honeywell
IQ 3 controllers incorporate a security features to prevent unathuorised access to the parameter of the controller. However, as default, no user is set up at the controller. Although no user is set up, one user still exist; System Guest with L100 (level 100) access). If you do not Log into the IQ 3 controller, you are log in as a System Guest which allow you full access for an unprotected controller
44
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Security Configuration
Default System Guest
Honeywell
As soon as you configure a user, the System Guess access level is changed to L-1 L(level -1). Hence basic read only access is given However, user 1 should always be configured at level 99 first and removed last.
45
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Configuration
Security Configuration
Level of Access
Honeywell
Once Users are configured, the module view window will only show appropriate modules depending on level access
46
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
47
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Portable Display
Display Panel
Introduction
Honeywell
TREND have provided portable display panel for the new IQ 3 network system
48
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Portable Display
TREND Network Display Panel IQ VIEW Portable Display A touch screen network display panel for interface to the TREND System Features
Honeywell
Provide a user interface to the TREND IQ system Self-configuration Display graphs View & adjustment of system values View alarms Trend Loop or Ethernet Connection Password user protection
49
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Portable Display
Display Panel
IQ View Overview
Honeywell
50
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Portable Display
Display Panel
IQ View Physical
Honeywell
51
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Portable Display
Display Panel
IQ View Connection
Honeywell
52
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Portable Display
Display Panel
IQ View Connection
Honeywell
53
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Portable Display
TREND Portable Display Panel Smart Display Unit (SDU) A small display panel for interface to the TREND System Features
Honeywell
Electroluminescent 4 x 20 character display Illuminated button for selection or adjustment Allows viewing and adjustment of plant parameters. Display the alarm log Access IQ via supervisor port only.
54
Honeywell
SUPERVISOR SOFTWARE
55
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Supervisor Software
INTRODUCTION
SUPERVISOR SOFTWARE : WHAT IS IT ?
Honeywell
A real time, user interface independent of the TREND System to allow monitoring and parameter adjustment to the system controllers. Main Features :
Device Viewer Graph Display Password Access Scheduling Capabilities Alarm Management
Workstation Supervisor - 963 Supervisor Software Pocket PC Supervisor - 916 Mobile Display Software (MDS)
N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S
File Number
56
Supervisor Software
TREND 963 Supervisor Software
A graphical real-time interface software for monitor / control for the graphical, TREND building system Workstation Supervisor
Honeywell
Features :
Time Schedules
Set-point Adjustment
Schematics Page
Alarm Database
Password Protection
Email Retransmission
Client -Server
57
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
963 Server Similar facilities with 963 Lite in addition of enabling the 963 to act as a web server allowing access through a web browser software such as Internet Explorer 963 Secure Similar facilities with 963 Lite plus an additional security features to comply to FDA Regulation 21 CPR Part 11 for pharmaceutical application 963 SNMP Similar facilities with 963 Lite plus the capabilities of retransmitting alarm in Simple Network Management Protocol (SNMP) format 963 SMS Direct Similar facilities with 963 Lite plus the capabilities of retransmitting alarm in Short Message Services (SMS) text messaging. GSM modem included
58
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Supervisor Software
TREND 916MDS Software
A portable real-time interface software for monitor / control for the portable, TREND building system Pocket PC Supervisor
Honeywell
Navigator
Monitoring Data
Trend Logs
Alarm Logs
Features Small hand held device true portability Instant operation, fast connection, Any Where Simple interface, easy to train, easy to use Ethernet (wireless), GSM, Bluetooth, Serial connection Trend parameters can be viewed and adjusted
59
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
INTERFACE
60
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Interface Device
TREND Relay Module
Single Relay Module (SRMV) :
Honeywell
Enables a controller analogue voltage output signal to drive a single changeover relay (Digital Output) Maximum resistive load 8 Amps
TREND Single Relay Module Voltage
Enables two controller analogue voltage output signal to drive two single changeover relay independently (Digital Output) Maximum resistive load 5 Amps with manual override link
TREND Single Relay Module AC
61
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Interface Device
TREND Signal Converter Module
Two Voltage (V) to two Current (I) Converter Driver Module (2VID)
Honeywell
Converts two channel controller analogue voltage output signal (0 to 10Vdc) to two current output signal (0 mA to 20 mA) Manual override links for aid of commissioning.
TREND 2VID Module
Converts a controller analogue voltage output signal (0 to 10Vdc) to a proportional pneumatic signal (0.2 bar to 1bar) Requires an external 24 Vac power supply.
62
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
FIELD DEVICES
63
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Field Devices
TREND provides a wide range of field devices to suit the need of many different applications. Range of Field Devices
Honeywell
Field Sensors
Temperature, Humidity, Pressure, Air Quality, Carbon Dioxide, Velocity Differential Pressure Current Transformer, Multi-parameter meter Occupancy Valve, Damper Threaded, Flanged
Field Switches
Electricity Meters
Detectors
Electronic Actuators
Valves
64
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Field Devices
TREND Wireless Temperature Sensors
Honeywell
No cable, no screwdriver, no hassle Simple set-up software Battery life in excess of 5 years
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Field Devices
TREND LCD Temperature Sensors
Honeywell
Connect to the controller via supervisor port (T-Bus) Can display reading in either Celsius or Fahrenheit Available in two variants
66
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Summary
TREND Network Summary
ETHERNET PNC
Honeywell
ENC2
EM/MPO
TMNG
IQ VIEW
GSM
IQ 242
TMNG
IQ VIEW
LINC
IQ 3XACT SUPERVISOR
MOBILE SOFTWARE
67
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
TREND System
Typical Building Application
Applications
Honeywell
68
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number
Honeywell
THE END
69
N O V A R
I N T E L L I G E N T
B U I L D I N G
S Y S T E M S
File Number