What is time synchronization and how does it work? Which solutions exist for telecom networks and attached networks? Which accuracy and stability is required? Why should manufacturers and operators of equipment for telecom networks care about these terms?
Low cost OEM module for synchronizat ion of telecom networks, transmitters and base stations
This document has been created to answer these questions and offers you a comprehensive and easy-to-understand introduction. Read on ... Many Thanks to Mr. Gerd Backhaus for his friendly support at this publication!
Telecom Time Synchronization Overview Telecom Time Synchronization Equipment Examples of use Telecom Time Synchronization Terms and Glossary
Generation of reference clocks for synchronizat ion tasks, the output signals are available with high accuracy and stability.
Communication requires excellent quality of service in the network! Synchronization equipment, planning and installation account for 1% of the overall project equipment costs. Synchronization must be considered and planned from the very beginning of a project. If the manufacturer cannot deliver synchronization equipment, he must inform the customer so that the customer can take steps to:
LANTIME M900 NTP Server Time Server Platform for Customized Time and Frequency Synchroniza tion Systems
Identify appropriate synchronization equipment Plan system synchronization appropriately Seek a Time & Frequency Specialist if necessary
Otherwise the performance in the network will suffer and will not comply with the ITU (International Telecommunication Union) standard. After an inventory of the hardware available, a preliminary network overview is made including the available timing reference sources. This can be used to plan the synchronization of switching devices. For transmission network synchronization (SDH), a plan must be developed with a special sync planning tool. In ITU-Recommendation G.811 (Timing Characteristics of Primary
PTP/IEEE 1588 Grandmaste r Clock and NTP Time Server with integrated GPS radio
Reference Clocks) a network clock stability of 1 x 10 E-11 for the Primary Reference Clock (RPC) is recommended. This accuracy is derived from 1 acceptable slip in a 2 MBit/s transmission in an observation time of 70 days. 1 (frame) = 125 us 125 us / 70 d x 24 h/d x 3600 s/h = 2 x 10 E-11 or +-1 x 10 E-11 This clock stability can be generated by atomic clocks only! There are different possible approaches to achieve the required accuracy. Different solutions are possible and can be realized using MEINBERG timing equipment.
clock
The Meinberg SyncBox/PT P simplifies a migration towards PTP/IEEE 1588 by providing a wide range of legacy time synchronizat ion outputs.
125s
Signalling Information or digital signal
Coded speech signal or digital signals in slot 1 - 15 Coded speech signals or digital signals in slot 17 - 31
X 0 0 1 1 0 1 1 X 1 D N Y Y Y Y 488 ns D: Service bit for critical alarm (Alarm D=1) N: Service bit for major alarm (Alarm N=0) X: Reserved bits for international use Y: Reserved bits for national use
Meinberg NTP Time Servers deliver a highly precise and the system, and provide precise NTP time for the network. For example, reliable time stamps are necessary for diagnosis of system error messages.
Examples of Use
* Mobile Equipment
Clock CP
E1
PCM 30
SN
PCM 30 PCM 30 2,048 MBit/s
E1
Recovered Clock
Clock CP
T3
PCM 30
SN
PCM 30 PCM 30
T3
Galileo / GPS
Clock Stability: 10 E-11 ! Exchange/Switch
GPS170 / LIU GPS170 / LIU
Clock CP
PCM 30
PCM 30
SN
PCM 30
E1 2,048 MBit/s
The PCM transmitters are transporting speech, data and exchange clock stability in HDB3* coded data stream.
*HDB3 (High Density Bipolar of order 3 code) is a telecommunications line code and is based on AMI.
BSC
Base Station Control: A GSM network element that handles BTS management and radio resource control. The BSC manages the radio interface, mainly through the allocation, release, handover and power control of radio channels. The BSC is synchronized over the PCM30-transmission of the Mobile Switching Center (MSC) and send the received clock accuracy over further PCM30-transmissions to the base stations.
BTS
Base Transceiver Station: A GSM network element that provides radio interface of the network. The BTS controls the radio transmission to and from the mobile terminals. It is synchronized over the PCM30 transmission from BSC and provides thereby the clock accuracy at the air interface.
GSM
Global System for Mobile Communications: GSM is the standard for the digital transmission technique which is world wide adopted. GSM uses 900 MHz and 1.800 MHz for transmission and receiving.
MSC
Mobile Switching Center: A GSM network element, for exchanging mobile subscribers. The MSC arranges also the switching to the subscribers in PSTN (Public switched telephone network). The MSC is a digital switching center which contains components like TRAU, BSCs and
BTSs for the radio interface. The MSC is synchronized by local clock sources, e. g. PRCs, GPS receivers or clock outputs (T4) of SDH network elements.
PBX
Private Branch Exchange: A telephone switch located on a customer's premises that primarily establishes voice-grade circuits over E1 links to PSTN (Public Switched Telephone Network).
PDH
The Plesiochronous Digital Hierarchy is a digital communication technology. PDH is based on the fundamental concepts of Time Division Multiplexing (TDM). Plesiochronous: (Greek - plesio, meaning near and chronos, meaning time) The meaning of Plesiochronous therefore is "nearly synchronous". Plesiochronous Digital Hierarchy is used to multiplex PCM30 transmissions to data streams with higher data rates and for transmission over digital transport equipment such as fiber optic and microwave radio systems. Although this transmission clock accuracy is not highly exact, the PCM30 data flow is transferred from synchronized switching centers, regarding data and clock transparency. Digital switching centers transfers synchronous PCM30 - data flow with this transmission technique to other switching centers, and the recovered clock can be used for its own synchronization. Much of the transport infrastructure based on plesiochronous digital hierarchy (PDH) is being replaced with SONET or SDH based infrastructure.
PRC
Primary Reference Clock: Usually a caesium standard that provides frequencies compliant with ITU G.811 or ETSI EN 300 462-6-1. The accuracy of PRC must be > 1 x 10-11.
SLIP
Slip = PCM30 - Frame Slip - always arises in a PCM receiver. The data are stored errorfree in a buffer, which can take up 2 PCM Frames. The buffer is read with the clock of the switching center. If the receiving switching center has a lower frequency than the transmitting switching center, the buffer cannot read the data in the same rate as these is written by the transmitter. A buffer overflow occurs with the result of a frame slip. If the receiving switching center has a higher frequency than the transmitting switching center, the buffer is faster read out, than it is filled. A buffer underflow occurs followed by
a slip frame. The slip rate is proportional to the frequency deviation between transmitter and receiver.
T3
Name of a clock input for clock generators (usually PLL) of a network element like e.g. switching center, BSC, BTS and SDH. These inputs can be synchronized with 2,048 MHz or 2,048 MBit/s. The interfaces are either symmetrical or asymmetrical.
T4
Designation of the clock output of a clock generator in a network element e.g. switching center, BSC, BTS and SDH. These output can deliver 2,048 MHz or 2,048 MBit/s. The interfaces are either symmetrical or asymmetrical.
E1
E1 transfers 32 time slots for each PCM frame - the first time slot of the first frame is the frame alignment signal (FAS). This signal makes the recognition of the frame in the PCM receiver, so that thereafter the time slots with speech data or data can be assigned to their goals correctly. The first time slot of the second PCM frame is the non frame alignment signal (NFAS) to transfer alarms and checksums (CRC4).
Trau
Transcoder Rate Adaption Unit. The TRAU belonged functionally to the mobile switching center. It has the GSM specific language coding and - decoding (from 64 kBit/s to 16 kBit/s per voice channel in both direcctions). It is synchronized over the PCM30-Transmission from MSC and transmits the received clock accuracy over PCM30 transmissions to the base station control (BSC). The TRAU is located at the BSC or directly at the MSC (mobile Switching center).
technology SDH network elements are synchronized. The payload data is stored in "containers" with additional information - the "Overhead" and the "Payload" is transmitted as synchronous transport module (e.g. STM-1). This transmission is normally accomplished over optical media. STM-1 designates a data rate of 155 MBit/s - e.g. 63 PCM30 transmissions can be transported. These 155 MBit/s data stream transports also the clock accuracy to the next SDH network element and synchronizes its clock generator. Thus a continuous synchronization of the SDH network is possible. The clock outputs (T4) of the SDH network elements can be used for the synchronization of further SDH network components or other connected mobile equipment. SDH uses the following Synchronous Transport Modules (STM) and rates: STM-1 (155 MBit/s) STM-4 (622 MBit/s) STM-16 (2.5 Gbit/s) STM-64 (10 Gbit/s)
The "line rate" describes the raw bit rate transferred via the optical fiber. A certain amount of the bit rate are the overhead, that includes information that provides OAM&P: Operations, Administration, Maintenance, and Provisioning information like framing, trace, multiplexing, status, and performance monitoring. The payload rate which is the available bandwidth for user data as packets or ATM cells is calculated by the line rate minus the overhead rate. Other rates like OC-9, OC-18, OC-24, OC-36, OC-96 were never widely implemented. Maybe higher rates like OC-3072 will defined in future times. The SONET/SDH level designations including a "c" suffix (e.g. "OC-48c") indicate a "concatenated" or "clear" channel. This shows, that the entire payload rate is available as a single channel of communications. In these channels the entire payload rate can be used by a single flow of packets. Opposed to the concatenated or clear channel is the "channelized". In a channelized link the payload rate is divided into several fixed rate channels. E.g. the payload of an OC-48 link can be subdivided into four OC-12 channels. In this scenario the data rate of a single cell or packet flow has its limitations in the bandwidth of the individual channel.
ANSI T1.105: SONET - Basic Description including Multiplex Structure, Rates and Formats ANSI T1.105.01: SONET - Automatic Protection Switching ANSI T1.105.02: SONET - Payload Mappings ANSI T1.105.03: SONET - Jitter at Network Interfaces ANSI T1.105.03a: SONET - Jitter at Network Interfaces - DS1 Supplement
ANSI T1.105.03b: SONET - Jitter at Network Interfaces - DS3 Wander Supplement ANSI T1.105.04: SONET - Data Communication Channel Protocol and Architectures ANSI T1.105.05: SONET - Tandem Connection Maintenance ANSI T1.105.06: SONET - Physical Layer Specifications ANSI T1.105.07: SONET - Sub-STS-1 Interface Rates and Formats Specification ANSI T1.105.09: SONET - Network Element Timing and Synchronization ANSI T1.119: SONET - Operations, Administration, Maintenance, and Provisioning (OAM&P) - Communications ANSI T1.119.01: SONET: OAM&P Communications Protection Switching Fragment
ITU-T G.707: Network Node Interface for the Synchronous Digital Hierarchy (SDH) ITU-T G.781: Structure of Recommendations on Equipment for the Synchronous Digital Hierarchy (SDH) ITU-T G.782: Types and Characteristics of Synchronous Digital Hierarchy (SDH) Equipment ITU-T G.783: Characteristics of Synchronous Digital Hierarchy (SDH) Equipment Functional Blocks ITU-T G.803: Architecture of Transport Networks Based on the Synchronous Digital Hierarchy (SDH)
Source: Synchronization in Telecom Networks (Dissertation from Gerd Backhaus at Meinberg Sales Meeting 2007)
Meinberg Funkuhren GmbH & Co. KG Lange Wand 9 D - 31812 Bad Pyrmont
Legal Notice and Privacy Policy | Sitemap Homepage: http://www.meinberg.de E-Mail: info@meinberg.de