Professional Documents
Culture Documents
ADDC Guidelines
ADDC Guidelines
LG Electronics Air Conditioning Marketing 20 Yoido-dong, Youngdungpo-gu, Yoido P.O.Box 355 Seoul 150-721, Korea Phone: 82-2-3777-7985 Fax: 82-2-3777-5136 http://www.lge.com
EU-CA091
w w w. l g e a i rc o n . c o m
02
03
08
Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG
09
DC Inverter Compressor BLDC Fan Motor *Testing Combinations
Capacity INDOOR OUTDOOR 2.5kW UT09 UU09W 3.5kW UT21 UU21W 5.0kW UT18 UU18W
2.5kW 3.5kW 5.0kW 3.62 3.70 3.33 3.21 3.64 3.21
U n i q u e
F e a t u r e s
DC Inverter Technology
With the advancement of inverter technology comes more silent, economical and powerful air conditioning systems.
Step-up Inverter by the PFC & the Sine Wave Control Technology
(PFC : Power Factor Correction)
The LG air conditioner is manufactured using the PFC and the sine wave technology. By the PFC contorl, raising the operating voltage from the existing DC 280V to DC 380V can be done. Thereby, it makes the operation smooth in a high-frequency area. The sine wave control enables soft operation in a low frequency area, thereby expanding the product's operating range. This also markedly improves the product's energy efficiency. Sine wave Control in BLDC Compressor
110Hz
90Hz
Power Time On Off On Off On Off Power Time
21 18 10
Loss
Full range
Sine wave
Rectangle wave
DC 380V (Boost up)
V I
Sine wave
Partial switching
46% Reduction
54% Reduction
806x1057x690mm 950x1380x330mm
Easy to Service
Easy & efficient installation of outdoor unit will provide the best solution for small offices and shops.
BLDC Fan
BLDC fan motor offers additional energy saving in operating mode. Compared with AC motors, BLDC fan motor can cut energy by 35% at full velocity. AC motor is operating at full velocity only, but BLDC Motor can change velocity according to load. Energy efficiency levels at low velocities in particular have been improved by 65%. Stator Rotor
Energy Saving
65%
35%
3 pieces of screw Ez SVC
1 way
Portial Load Full Load
4 way
Load
Inverter Technology
COP
Cooling
Heating
40
Synchro
Simultaneously On/Off (1 Cycle) Connectable up to 4 indoor units Only using simple branch piping DC Inverter : 12.5/14.0/15.0 kW 3Phase DC Inverter : 12.5/14.0/15.0 kW
41
2 branch PMUB11A
3 branch PMUB111A
4 branch PMUB1111A
Synchro operation
It offers very useful solution to customer with reasonable prices. It uses 2,3 or 4 indoor units with one outdoor unit. Each indoor units are running as one cycle with same mode(cooling or heating). It helps same air distribution all arround the middle or larger room(office or open places) even in irregualr shaped spaces. The total capacity based on outdoor unit for Synchro operation are the same as for the fixed combinations.
Synchro
DC INVERTER
42
3PHASE DC INVERTER
43
Synchro Outdoor
Synchro Outdoor
UU60W U3D
"Synchro application (simultaneous operation). Refer to combination table. " 24.7/23.5 1, 220~240, 50 950*1380*330 (37.4*54.3*13.0) 103(227) 3600(127) 55(1942) X 2 55/51 9.52 (3/8) 15.88 (5/8) 80 40 40 10 30 1
UU43W U3D
Nominal Capacity (Min~Rated~Max) Norminal Input (Min~Rated~Max) Running Current Power supply Dimensions Net Weight Refrigerant Air Circulation Noise Level(H/L) SVC Valve Gas Max. Interunit Piping Length Cooling Heating Cooling Heating Cooling/Heating W*H*D Outdoor Charge* kW Btu/h kW kW A ,V,Hz mm(inch) kg(lbs) g(oz) CMM(CFM) dB(A)3 mm (inch) m m m m m m
"Synchro application (simultaneous operation). Refer to combination table. " 4.09/4.28 3 ,380~415 , 50 "950*1380*330 (37.4*54.3*13.0)" 103(227) 3600(127) 55(1942) X 2 55/51 9.52 (3/8) 15.88 (5/8) 80 40 40 10 30 1
UU49W U3D
"Synchro application (simultaneous operation). Refer to combination table. " 4.98/5.23 3 ,380~415 , 50 "950*1380*330(37.4*54.3*13.0)" 103(227) 3600(127) 55(1942) X 2 55/51 9.52 (3/8) 15.88 (5/8) 80 40 40 10 30 1
UU61W U3D
"Synchro application (simultaneous operation). Refer to combination table. " 5.91/5.79 3 ,380~415 , 50 "950*1380*330 (37.4*54.3*13.0)" 103(227) 3600(127) 55(1942) X 2 55/51 15.88 (5/8) 80 40 40 10 30 1
Sound Press,1m Liquid mm (inch) Total Piping(Main+Total Branch) Main Piping Total Branch Piping Each Branch Piping Indoor Unit~Outdoor Unit Indoor Unit~Indoor Unit
Sound Press,1m Liquid mm (inch) Total Piping(Main+Total Branch) Main Piping Total Branch Piping Each Branch Piping Indoor Unit~Outdoor Unit Indoor Unit~Indoor Unit
Cooling Heating
Cooling Heating
-10 ~ 43 -15 ~ 24
Cooling Heating
Cooling Heating
-10~43 -15~24
Note : Due to our policy of innovation some specifications may be changed without notification.
Note : Due to our policy of innovation some specifications may be changed without notification.
Synchro
9.52 (3/8)
44
45
Synchro
Combination Table
Possible combination of indor units Installation scene Duo
IDU : INDOOR UNIT ODU : OUT DOOR INUT BD : BRANCH DISTRIBUTOR UNIT REMO : WIRED REMOTE CONTROLLER IDU REMO ODU
Installation Information
1. Piping Connections
Model Indoor Quartet
ODU BD IDU IDU REMO IDU IDU IDU
Cassette Duct Ceiling & Floor 1 Inverter 3 Inverter Inch [mm] Inch [mm]
UT18 NQD UB18 NHD UV18 NBD 1/4 (6.35) 1/2 (12.7)
UT24 NPD UB24 NHD UV24 NBD 3/8 (9.52) 5/8 (15.88)
UT30 NPD UB30 NGD UV30 NBD 3/8 (9.52) 5/8 (15.88)
Trio
ODU BD IDU IDU REMO IDU
Model Outdoor
BD
Liquid Gas
OUTDOOR UNITS
Capacity (kW) Cooling Heating 12.5 14.0 15.0 14.0 16.0 17.0
Ceiling & Floor UV24 NBD *2 UV24 NBD *2 UV30 NBD *2 PVRCUSZ0
Ceiling & Floor UV18 NBD *3 UV18 NBD *3 UV18 NBD *3 PVRCUSZ0
Duct -
2. Power Supply
Model Outdoor Power Supply Model Outdoor Power Supply
UU42W U3D UU43W U3D UU48W U3D UU49W U3D UU60W U3D UU61W U3D
1 Inverter
, Voltage
3 Inverter
, Voltage
Applied Accessiries
PMUB11A
PMUB1111A
1 Inverter 3 Inverter
UU30 35 UU30W 35
UU37 40 UU36W 35
UU48 40 UU48W 50
UU60 50 UU60W 50
Model Outdoor
4. Drain Pipe
Model Indoor Cassette
Measurement Conditions
1. Capacities are based on the following conditions: Cooling: Heating: - Indoor Temperature 27oC DB /19oC WB - Outdoor Temperature 35oC DB / 24oC WB - Indoor Temperature 20oC DB / 15oC WB - Outdoor Temperature 7oC DB / 6oC WB
- Level Difference Within Zero. - No optional accessories (i.e. Plasma kit, elevation grille etc.) - With maximum air volume.
Note :Due to our policy of innovation some specifications may be changed without notification.
Branch Pipe
Model PMUB11A PMUB111A PMUB1111A
Synchro