The Sunny Central CP series maximizes project investment returns through innovative technology and time-saving features.
Optiprotect integrates string failure detection into the inverter and centrally monitors up to 1,600 module strings without requir-
ing conventional communication wiring in the field. The self-learning monitoring system significantly simplifies commissioning.
Up to 32 motor-driven, adjustable DC inputs ensure maximum plant availability. And, thanks to its compact and weatherproof
enclosure, the inverters can be loaded and transported with ease and set up almost anywhere.
Oc|c|oo o|ccco |c |||||,cc|o |\
SUNNY CENTRAL
500CP / 630CP / 720CP / 760CP / 800CP
SUNNY CENTRAL
500CP / 630CP / 720CP / 760CP / 800CP
Reliable
Safe and easy installation due to
separate connection area
Powerful grid management functions
(including LVRT)
Flexible
Configurable DC voltage range
Optional: Extended input voltage
range up to 1,100 V
Efficient
Full nominal power at ambient
temperatures up to 50 C
110% rated power at ambient
temperatures up to 25 C
Economical
Optiprotect ensures maximum
plant availability
Outdoor-rated enclosure allows for
direct field deployment
Technical data
Sunny Central
500CP
Sunny Central
630CP
Input Data (DC)
Max. DC power (@ cos =1) 560 kW 713 kW
Max. input voltage
1)
1000 V / 1100 V optional 1000 V / 1100 V optional
MPP voltage range (@ 25 C / @ 50 C at 50 Hz) 449 V 820 V / 430 V 820 V
2)
529 V 820 V / 500 V 820 V
2)
MPP voltage range (@ 25 C / @ 50 C at 60 Hz) 449 V 820 V / 436 V 820 V
2)
529 V 820 V / 505 V 820 V
2)
Rated input voltage 480 V 550 V
Max. input current 1250 A 1350 A
Minimum input voltage / V
MPP_min
at I
MPP
< I
DCmax
429 V / 430 V 498 V / 500 V
Number of independent MPP inputs 1 1
Number of DC inputs 9 / 32 (Optiprotect) 9 / 32 (Optiprotect)
Output (AC)
Rated power (@ 25 C) / nominal AC power (@ 50 C) 550 kVA / 500 kVA 700 kVA / 630 kVA
Nominal AC voltage / range 270 V / 243 V 297 V 315 V / 284 V 347 V
AC frequency / range 50 Hz, 60 Hz / 47 Hz 63 Hz 50 Hz, 60 Hz / 47 Hz 63 Hz
Rated frequency / rated voltage 50 Hz / 270 V 50 Hz / 315 V
Max. output current 1176 A 1283 A
Max. THD < 3 % < 3 %
Power factor at rated power / adjustable shift factor 1 / 0.9 leading ... 0.9 lagging
Feed-in phases / connection phases 3 / 3 3 / 3
E ciency
7)
Max. e ciency / European e ciency / CEC e ciency 98.6 % / 98.4 % / 98.5 % 98.7 % / 98.5 % / 98.5 %
Protection
Input side disconnection device Motor-driven switch-disconnector / circuit breaker (Optiprotect)
Output side disconnection device AC circuit breaker
DC overvoltage protection / AC overvoltage protection Surge arrester type I / surge arrester type I
Grid monitoring
Ground fault monitoring / Remote ground fault monitoring / /
Insulation monitoring
Surge arrester for auxiliary supply
Protection class (as per IEC 62103) / overvoltage category (as per IEC 60664-1) I / III I / III
General Data
Dimensions (W / H / D) 2562 / 2279 / 956 mm (101 / 90 / 38 inch)
Weight 1800 kg 1800 kg
Operating temperature range -20 C +50 C -20 C +50 C
Noise emission
5)
60 db(A) 60 db(A)
Max. self-consumption (in operation) / self-consumption (at night) 1700 W
4)
/ < 100 W 1700 W
4)
/ < 100 W
External auxiliary supply voltage 230 / 400 V (3 / N / PE) 230 / 400 V (3 / N / PE)
Cooling concept OptiCool OptiCool
Degree of protection: electronics / connection area (as per IEC 60529) IP54 / IP23 IP54 / IP23
Application Unprotected outdoors Unprotected outdoors
Maximum permissible value for relative humidity (non-condensing) 15 % 95 % 15 % 95 %
Maximum operating altitude above MSL 2000 m 2000 m
Fresh air consumption 3000 m/h 3000 m/h
Features
DC terminal Ring terminal lug / cage terminal
(Optiprotect)
Ring terminal lug / cage terminal
(Optiprotect)
AC terminal Ring terminal lug Ring terminal lug
Display
Communication protocols Ethernet (optical ber optional), modbus Ethernet (optical ber optional), modbus
Sunny String-Monitor RS485 / is not required (Optiprotect) RS485 / is not required (Optiprotect)
Color of enclosure, door, base, roof RAL 9016 / 9016 / 7005 / 7004
Certicates and approvals (more upon request) EN 61000-6-2, EN 61000-6-4, EEG conformity, Arrt du 4/23/08,
R.D. 1663 / 2000, R.D. 661 / 2007, BDEW-MSRL / FGW / TR8
Classication of the ambient conditions (according to IEC 60721-3-4) 4S2, 4C2
Standard features Optional features Not available
Type designation SC 500CP-10 SC 630CP-10
Sunny Central
720CP
Sunny Central
760CP
Sunny Central
800CP
808 kW 853 kW 898 kW
1000 V / 1100 V optional 1000 V / 1100 V optional 1000 V / 1100 V optional
577 V 820 V / 525 V 820 V
2) 3)
609 V 820 V / 554 V 820 V
2) 3)
641 V 820 V / 583 V 820 V
2) 3)
577 V 820 V / 525 V 820 V
2) 3)
609 V 820 V / 554 V 820 V
2) 3)
641 V 820 V / 583 V 820 V
2) 3)
565 V 595 V 620 V
1400 A 1400 A 1400 A
515 V / 515 V 545 V / 545 V 568 V / 570 V
1 1 1
9 / 32 (Optiprotect) 9 / 32 (Optiprotect) 9 / 32 (Optiprotect)
792 kVA / 720 kVA 836 kVA / 760 kVA 880 kVA / 800 kVA
324 V / 292 V 356 V 342 V / 308 V 376 V 360 V / 324 V 396 V
50 Hz, 60 Hz / 47 Hz 63 Hz 50 Hz, 60 Hz / 47 Hz 63 Hz 50 Hz, 60 Hz / 47 Hz 63 Hz
50 Hz / 324 V 50 Hz / 342 V 50 Hz / 360 V
1411 A 1411 A 1411 A
< 3 % < 3 % < 3 %
1 / 0.9 leading ... 0.9 lagging
3 / 3 3 / 3 3 / 3
98.6 % / 98.4 % / 98.5 % 98.6 % / 98.4 % / 98.5 % 98.6 % / 98.4 % / 98.5 %
Motor-driven switch-disconnector / circuit breaker (Optiprotect)
AC circuit breaker
Surge arrester type I / surge arrester type I

/ / /


I / III I / III I / III
2562 / 2279 / 956 mm (101 / 90 / 38 inch)
1800 kg 1800 kg 1800 kg
-20 C +50 C -20 C +50 C -20 C +50 C
60 db(A) 60 db(A) 61 db(A)
1700 W
4)
/ < 100 W 1700 W
4)
/ < 100 W 1700 W
4)
/ < 100 W
230 / 400 V (3 / N / PE) 230 / 400 V (3 / N / PE) 230 / 400 V (3 / N / PE)
OptiCool OptiCool OptiCool
IP54 / IP23 IP54 / IP23 IP54 / IP23
Unprotected outdoors Unprotected outdoors Unprotected outdoors
15 % 95 % 15 % 95 % 15 % 95 %
2000 m 2000 m 2000 m
3000 m/h 3000 m/h 3000 m/h
Ring terminal lug / cage terminal
(Optiprotect)
Ring terminal lug / cage terminal
(Optiprotect)
Ring terminal lug / cage terminal
(Optiprotect)
Ring terminal lug Ring terminal lug Ring terminal lug

Ethernet (optical ber optional), modbus Ethernet (optical ber optional), modbus Ethernet (optical ber optional), modbus
RS485 / is not required (Optiprotect) RS485 / is not required (Optiprotect) RS485 / is not required (Optiprotect)
RAL 9016 / 9016 / 7005 / 7004
EN 61000-6-2, EN 61000-6-4, EMC conformity, CE conformity, Arrt du 4/23/08, R.D. 1663 / 2000,
R.D. 661 / 2007, BDEW-MSRL / FGW / TR8
4S2, 4C2
SC 720CP-10 SC 760CP-10 SC 800CP-10
1) Startup at DC voltage < 1000 V
2) At 1.05 V
AC, nom
and cos = 1
3) Further AC voltages, DC voltages and power classes can be configured (for more detailed information, see technical information Innovations_CP at www.SMA.de)
4) Self-consumption during nominal operation
5) Sound pressure level at a distance of 10 m
6) With complete dynamic grid support
7) Efficiency measured without internal power supply
SMA America, LLC
Toll Free +1 888 4 SMA USA
www.SMA-America.com
.
C
C
|
/
|
|
|
O
.
|
|




.
'
/

c

o

.

,

C
o

|
c
|
c

|
|o

o
o

|
c
o
o


c
|

.
'
/

.
c
|c

o
c
|

c
|c

,

/
C
.

o
x
|
c

o

|||

|
c
||c


c
c

|
c


|c

|o
c
|

|c
c
|

|c

o
c

|
||

o
c
|

|c
c
|

c
o
||
|c
c
||c

.
o
o
.

|
c

||c
|
||||,

|
c

|
||

.

|

|
|o
o

c


c
|
|c

|
o
|

o
o

You might also like