Central Changing of Triggers in WinCC V6.2 Images (PDL)
Central Changing of Triggers in WinCC V6.2 Images (PDL)
I&S IS E&C PS 2
Content
Requirements Overview of the basic functions Functions o Search tags & change trigger cycles o Search tag list & change trigger cycles o Search trigger cycle and replace trigger cycle o Search tag list and a certain trigger cycle and replace trigger cycle o Search all triggers and create logfiles Contact
Siemens AG
Seite 1 / 10
SIEMENS AG
I&S IS E&C PS 2
Requirements Hardware
The minimum requirements of the WinCC Version stated below are valid. Please note: The faster the CPU of the PC, the faster many images can be edited!
Software
Windows XP SP2 Windows 2003 SP1 & R2 WinCC V6.2
Important hints:
Back up your WinCC project or the WinCC images before using the Trigger Tool for the first time. The images are being saved while editing and you cannot undo this procedure. The WinCC project must be opened in the WinCC Explorer. If there are already images during installation, select unchange so that you can still use your new version.
Siemens AG
Seite 2 / 10
SIEMENS AG
I&S IS E&C PS 2
General functions: It is either possible to search in all WinCC images or in the image that is currently open in the Graphics Designer. A logfile can be created with every change to document the changes.
Siemens AG
Seite 3 / 10
SIEMENS AG
I&S IS E&C PS 2
Function 4: Search Tag list with a certain Trigger cycle and replace Trigger cycle
It is possible to search a trigger cycle and a taglist in all WinCC images or in the actively open WinCC image. The cycle can be changed if the trigger cycle is found in connection with a tag in the tag list.
Siemens AG
Seite 4 / 10
SIEMENS AG
I&S IS E&C PS 2
Siemens AG
Seite 5 / 10
SIEMENS AG
I&S IS E&C PS 2
Function 2
Search Tag List & Change Trigger cycle
Press Select Tag List and select the text file with the tag names that have to be searched. Select the target trigger in the selection dialog box. Select if all images or the one that is currently open need to be searched. Select if a logfile needs to be created. Change Trigger to start the process!
Siemens AG
Seite 6 / 10
SIEMENS AG
I&S IS E&C PS 2
Function 3
Search Trigger cycle and replace Trigger cycle
Select the trigger cycle in the first selection dialog box. Select the target trigger in the second selection dialog box. Select if all images or the one that is currently open need to be searched. Select if a logfile needs to be created. Change Trigger to start the process!
Siemens AG
Seite 7 / 10
SIEMENS AG
I&S IS E&C PS 2
Function 4
Search Trigger cycle and replace Trigger cycle
Select the trigger cycle in the first selection dialog box. Press Select Tag List and select the text file with the tag names that have to be searched. Select the target trigger in the second selection dialog box. Select if all images or the one that is currently open need to be searched. Select if a logfile needs to be created. Change Trigger to start the process!
Siemens AG
Seite 8 / 10
SIEMENS AG
I&S IS E&C PS 2
Function 5
Search all triggers and create logfiles
Select if all images or the one that is currently open need to be searched. Press Find all Triggers to start the process.
Siemens AG
Seite 9 / 10
SIEMENS AG
I&S IS E&C PS 2
Contact
Siemens AG Industrial Solutions and Services I&S IS E&C PS 24 Schreiberhauer Strasse 3 90475 Nrnberg, Germany Tel.: +49 911 895-2492 Ansprechpartner: Norbert Wagner Norbert.Wagner@siemens.com Markus Tannert Markus.Tannert@siemens.com Dieter Ungemach Dieter.Ungemach@siemens.com Competence Center: WinCC-COC-Nbg.Automation@Siemens.com