Copyright Siemens AG 2004 All rights reserved The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved.
Disclaimer of Liability We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are welcomed.
Siemens AG Bereich Automation and Drives Geschaeftsgebiet Industrial Automation Systems Postfach 4848, D- 90327 Nuernberg
Siemens Aktiengesellschaft
A5E00325950-01
1.1
Creating a Project
1-1
Creating a Project
Proceed as follows in order to create a project: 1. Select the menu command File > New. 2. Enter a name for the project (such as "PDM_1") in the displayed dialog box. Verify that the "Project" and not the "Library" option is selected. 3. Confirm by clicking "OK".
1-2
4. The new project task window "PDM_1" is displayed. Double-click the "Networks" icon in the right-hand screen section. After this, the left-hand screen section will be shifted over.
1-3
1-4
1-5
3. In the "Name" field, enter the desired name for the HART device (in our example HART_1). Note: If have an option of 128 tags or more, the change log is also active. All changes to a project are recorded in this log. In addition, a dialog box is displayed in which you are prompted to enter comments on changes. 4. Confirm your entries with "OK". The program adds a device named "HART_1 1" to the project. The device is inserted in the right-hand section of the window.
1-6
5. Double-click the device that you have just created. The SIMATIC PDM application is opened. In the dialog box that is displayed, select whether you want to work as a "Maintenance Engineer" or "Specialist". Confirm your selection with "OK".
6. The "SIMATIC PDM Device Selection" dialog box is displayed. Now select your HART device type. If it is not available, you can install the desired device at this time. To do so, click the Device Catalog button. In the dialog box that is then displayed, navigate to the folder containing the device catalog. Now select the HART device type. 7. Confirm your selection with "OK". Note: This process may take a few minutes. All current device descriptions (.DDLs) will be loaded. Updates can be downloaded form the following Siemens website (address current as of May 2000):
http://www.feldgeraete.de/76/produkte/simatic_pdm/infos.html
1-7
Selecting a Sensor
To select a sensor, proceed as follows: 1. Double-click one of the sensors which you have inserted (such as on HART_1 1 in the example). 2. Select Sensors > Pressure > SIEMENS > SITRANS P-DS > Pressure > 16 Bar menu command to choose the appropriate sensor. Configure any other devices you have selected for your project in the same manner.
3. After you have made your selections, confirm them with "OK".
1-8
1-9
1.2
1-10
1.3
Configuring a Device
Start SIMATIC PDM by double-clicking the device symbol in the SIMATIC Manager. In the dialog box that is then displayed, select the "Specialist" or "Maintenance Engineer" option. Confirm your selection with "OK". The SIMATIC PDM logo is now displayed.
SIMATIC PDM is now opened for the HART device that you selected. The values displayed in the right-hand section of the window are not "current" values but come from the DDL that you selected. To obtain the current values for your device, select the Device > Upload to PG/PC menu command or click the corresponding button in the toolbar.
1-11
Caution: Before downloading data to a device, you should connect the software to the HART device via the HART modem and upload the data currently in the device to your PC. To do this, select the Device > Upload to PG/PC menu command or click the corresponding button in the toolbar. The on-screen values are replaced by the actual values for the device. In the status bar, the status changes from "Not connection" to "Connected". If you edit these values, their status changes from "Initial value" or "Uploaded" to "Changed". To transfer the data to the sensor, select the menu command Device > Download to Device or click the corresponding button in the toolbar. All previous sensor data will be overwritten with your edited data. Therefore, be sure to verify the correctness of all data before you transfer it to the device.
1-12
Note: It is possible that the HART device is not integrated in your version of SIMATIC PDM. If this is the case, then please contact a Siemens representative at the appropriate Siemens business office or service partner. To find the appropriate contact person, please go to: http://www.siemens.com/automation/partner
Congratulations! You now have worked through this "Getting Started" and become acquainted with important terms, procedures and functionalities of SIMATIC PDM. You are now ready to create your first project. Should you encounter problems finding information on certain functions or operating sequences for SIMATIC PDM or should you forget required command sequences, please refer to our extensive Help on SIMATIC PDM. We wish you a lot of success with your future projects!