syngo GRAPPA

Powered by Tim

www.siemens.com/medical
syngo GRAPPA
Powered by Tim

GRAPPA is a Siemens exclusive, k-space


based parallel imaging technique. GRAPPA
is important clinically because GRAPPA
can be applied through the entire body,
head-to-toe at smaller FoV’s without
artifacts. All Tim matrix coils, array coils
and various combinations of coil elements
are compatible with GRAPPA. Both 2D
and 3D scans can utilize GRAPPA to speed
acquisition and/or resolution.

Clinical Role
1. Higher Speed:
a) GRAPPA with Tim matrix coils
gives maximum freedom in
selecting the slice orientation
and acceleration factors.
b) Speed can be utilized to improve
temporal resolution in dynamic
studies and cardiac exams.
c) Reducing scan times and
breath-hold periods particularly
for uncooperative patients and
Figure 1: Primary sclerosing cholangitis. 2 min. 3D MRCP with iPAT factor 4.
Institute of Clinical Radiology, University Hospitals, Grosshadern, children can eliminate certain
Ludwig-Maximilians-University, Munich, Germany. movement artifacts (Figure 1).

2. Better resolution and anatomical


coverage:
a) The time saved with speed can be
utilized for high resolution scans
achieved in the same scan times
(Figures 2A–2C).
b) Alternatively, the anatomical
coverage (increase TR and # of
slices) can be increased keeping
the time the same.
2
Figure 2A: 3D WE TrueFISP, GRAPPA 2. Figure 2B: Fat Sat, GRAPPA 2, 2:12, 3.5, 8 cm. Figure 2C: GRAPPA 2, 2:00, 2 mm, 9 cm.

Figure 3A: Without GRAPPA – more distortions. Figure 3B: With GRAPPA – less distortions.

3. Reduction of artifacts:
Figure 4:
a) Using GRAPPA permits MR GRAPPA 2, 3D Fat Sat
parameter changes like TE and VIBE, 120 slices in
bandwidth that help reduce 16 sec breath-hold,
susceptibility artifacts particularly 2 mm partitions.
for EPI based sequences. This is Courtesy of NYU,
MAGNETOM Avanto.
beneficial in the orbital, nasal sinus
and posterior fossa regions in the
brain.

3
On account of certain regional limitations of Contact Address USA
sales rights and service availability, we cannot Siemens Medical Solutions USA, Inc.
guarantee that all products included in this Magnetic Resonance Division
brochure are available through the Siemens 51 Valley Stream Parkway
sales organization worldwide. Availability and Malvern, PA 19355-1406 USA
packaging may vary by country and is subject Telephone: 1-888-826-9702
to change without prior notice. Some/all of the
features and products described herein may not
be available in the United States.

The information in this document contains


general technical descriptions of specifications
and options as well as standard and optional
features which do not always have to be present
in individual cases.

Siemens reserves the right to modify the design,


packaging, specifications and options described
herein without prior notice. Please contact your
local Siemens sales representative for the most
current information.

Note: Any technical data contained in this


document may vary within defined tolerances.
Original images always lose a certain amount
of detail when reproduced.

© 02.2007, Siemens AG
Order No. A91MR-1100-9C-7600
Printed in Germany
CC MR 01100 WS 02073.

Headquarters
Siemens AG, Medical Solutions
Henkestr. 127, D-91052 Erlangen
Germany
Telephone: +49 9131 84-0
www.siemens.com/medical

www.siemens.com/medical

You might also like