Professional Documents
Culture Documents
Alignment On Sundyne Compor Pump
Alignment On Sundyne Compor Pump
Alignment On Sundyne Compor Pump
Timeline of Events
Visit from Dennis Schrumpf / Matt Schaeffer, ConocoPhillips Wood River in January 2008 Request of improvements with alignment of driver to pump. Request for elimination of dowel pinning or reworking procedures. Request was specific to Sundyne OH3 Bearing Box Pump (Sundyne LMV-80x Series). LMV 80x pumps shown in earlier slides are API OH5 designs with the impeller mounted directly on the driver shaft. Add a bearing housing (bearing box) to convert to OH3 design.
Aluminum (Light Weight) Non-Sparking All DBSE Problems Addressed Coupling Alignment Issues Addressed
Proposed Changes
Change:
Dimensions Tolerances
0.005 Unilateral to 0.004 Equilateral
Nominal 0.0015 0.002
Motor
Coupling Housing
Preliminary Results
To Date:
Data taken on 4 sets of hardware, 16 combinations. Data as Follows:
TIR Conc TIR Ang Avg 0.007125 0.002625 Max 0.014 0.005 Min 0.0015 0.0005
Preliminary Results
To Date:
One housing appears to give consistently bad values. Inspection being performed to determine cause. Without housing, data as follows:
TIR Conc TIR Ang Avg 0.005542 0.002417 Max 0.011 0.005 Min 0.0015 0.0005
Preliminary Results
Sundyne feels confident it can achieve:
TIR Conc. Avg. 0.005 Max 0.010 TIR Ang. 0.003 0.005
Future Plans:
Evaluate Per PN 41.25-52 30 units to see actual results Revise, if necessary, assumptions and design to achieve goal
Documentation
Process note 41.25-52 attached ISO Form 2910 attached
Alignment Verification Report Included in Final Documentation
Conclusion
Questions?