Coupling Housing Alignment Project

Sundyne Corporation August 2008

LMV-801 Max Flow: 380 gpm Max Head: 720

LMV-802 Max Flow: 150 gpm Max Head: 210

LMV-806 Max Flow: 380 gpm Max Head: 760

LMV-322 Max Flow: 230 gpm Max Head: 3,000

LMV-311 Max Flow: 400 gpm Max Head: 6,300

Timeline of Events
Visit from Dennis Schrumpf / Matt Schaeffer, ConocoPhillips Wood River in January 2008 Request of improvements with alignment of driver to pump. Request for elimination of dowel pinning or reworking procedures. Request was specific to Sundyne OH3 Bearing Box Pump (Sundyne LMV-80x Series). LMV 80x pumps shown in earlier slides are API OH5 designs with the impeller mounted directly on the driver shaft. Add a bearing housing (bearing box) to convert to OH3 design.

Bearing Box Change


Request for improvement well timed with Bearing Box redesign.

Sundyne Bearing Housing for OH3 Design

Overview of Bearing Box Changes


API OH3 Compliant Back-to-Back Angular Contact Bearings More Modular
Uses same coupling housing as Gear-Driven Units

Coupling Housing Change


Request for Improved Alignment Well Timed:
New Design Being Implemented

Previous Design: Fabricated from Steel

New Design: Cast Aluminum

Overview of Coupling Housing Changes


One Piece Casting
All configurations with 3 castings Ability to hold high tolerances

Aluminum (Light Weight) Non-Sparking All DBSE Problems Addressed Coupling Alignment Issues Addressed

Coupling Alignment Fix


Change was Implemented Across All Sundyne LMx Products
Direct Drive and Gear Driven Fix was considered a global product improvement.

Proposed Changes
Change:
Dimensions Tolerances
0.005 Unilateral to 0.004 Equilateral
Nominal 0.0015 0.002

Motor

Nominal + 0.0015 0.002

Coupling Housing

HO13AA03 HO13AA04 HO13AB03 HO06AA16 HO06AA19 HO06AB01 HO06AA05 HO06AG04 HO06AW03

Nominal 0.0015 0.002

Bearing Box / Gearbox

Preliminary Results
To Date:
Data taken on 4 sets of hardware, 16 combinations. Data as Follows:
TIR Conc TIR Ang Avg 0.007125 0.002625 Max 0.014 0.005 Min 0.0015 0.0005

Preliminary Results
To Date:
One housing appears to give consistently bad values. Inspection being performed to determine cause. Without housing, data as follows:
TIR Conc TIR Ang Avg 0.005542 0.002417 Max 0.011 0.005 Min 0.0015 0.0005

Preliminary Results
Sundyne feels confident it can achieve:
TIR Conc. Avg. 0.005 Max 0.010 TIR Ang. 0.003 0.005

Future Plans:
Evaluate Per PN 41.25-52 30 units to see actual results Revise, if necessary, assumptions and design to achieve goal

Documentation
Process note 41.25-52 attached ISO Form 2910 attached
Alignment Verification Report Included in Final Documentation

Sundyne Process Note PN41.25-52

Sundyne Process Note PN41.25-52

Typical Coupling Drawing

Conclusion

Questions?