Professional Documents
Culture Documents
Cvcalcs Sample
Cvcalcs Sample
xlsx
Nomenclature P1 P2 Delta P Pv G
Cf Cv del Ps Pc Gf
Critical Flow Factor Valve Flow Coefficient Pressure drop for critical flow calculations Critical Pressure Gas s.g. at flowing temperature
Liquids
Job No. Tag No. Service Flow (gpm) P1 (psia) Delta P (psi) Fluid s.g.
CV-XXX
LIQUID - Calc CV Cooler water TT heater water valve(sum) TT heater water valve(win)
245.46 56 485 39
404.95 40 40 40
19 5 10 10
0.5 1 1 1
XXXX
CV-XXX
48
45
XXXX
CV-XXX
48
45
INSTRUCTIONS 1 Press F5 and select whichever calculation you want to use (for example LIQUID-CalcCV) 2 Pick Edit Copy 3 Move the cursor to the line you want to copy to in the column under Job No. 4 Pick Edit Insert Paste (it will ask you if you want to Shift Cells Down - pick OK) 5 Enter values in all the cells with yellow backgrounds - other values will be calculated. FOR MORE INFO PRESS F5 and SELECT NOMENCLATURE
Page 1
97580531.xlsx
al flow calculations
Fluid Pv (psia)
Fluid Pc (psia)
Valve Cf
Check for Critical Flow Condition (cavitation or flashing) Flow del Ps Critical? Cv (psi)
Notes
48 15.64 3 3
0.75 0.75 1 1
NO NO NO NO
15.64
3206
0.75
NO
21.5
44.35
15.64
3206
0.75
NO
21.5
44.35
UID-CalcCV)
Page 2
97580531.xlsx
Saturated Steam
Job No 67194 67194 63593 67194 76997 XXXXX XXXXX Tag No Service Flow lb/hr 25600 106000 2590 15000 600 1000 1000 P1 Delta P (psia) (psi) 19.7 5 19.7 5 85 37 20 5 85 5 85 85 10 10
CANADA SALT OUTLET ADM OUTLET CV-105/205 team to water injector heater S Steam line purge ster Sterlilizer steam CV-XXX CV-XXX SAT'D STEAM - Calc Cv SAT'D STEAM - Calc Delta P
CV-XXX
SAT'D STEAM - Calc Flow Steam to kettles PV804A-C Booster motive steam, 10" PV804D Booster motive steam, 4"
10 35 1 1
Page 3
97580531.xlsx
Check for Critical Flow Condition Valve Cf 0.65 0.65 0.75 0.75 0.75 0.75 0.75 Cv 1092.5 4523.5 22.2 539.9 9.9 11.9 11.9 Flow Critical? YES YES YES NO NO NO NO P2 (psia) 14.7 14.7 48 15 80 75 75 170
Notes
NO NO NO NO
Page 4
97580531.xlsx
Gases
c Job No Tag No Service Flow lb/hr Gas M.W.
GASES - Calc Cv GASES - Calc Delta P GASES - Calc Delta P Cylinder lift GASES - Calc Flow
18 18 18 29 18
Page 5
97580531.xlsx
Temp (deg F)
P1 (psia)
Delta P (psi)
Valve Cf
Check for Critical Flow Condition at s.c.=32F, 14.7 psia Cv Flow Gas s.g. Gf P2 Critical? G (psia)
20 85 85 85 85
5 10 10 5 10
NO NO NO NO NO
15 75 75 80 75
Page 6
97580531.xlsx
Superheated Steam
Notes b c Job No Tag No
Page 7
97580531.xlsx
eated Steam
Service Flow lb/hr P1 (psia) Delta P (psi) Valve Cf Superheat (deg F)
SUPERHTD STEAM - Calc Cv SUPERHTD STEAM - Calc Delta P SUPERHTD STEAM - Calc Delta P SUPERHTD STEAM - Calc Flow SUPERHTD STEAM - Calc Flow
85 85 85 85 85
10 10 10 10 10
0 0 0 0 0
Page 8
97580531.xlsx
Notes
NO NO NO NO NO
Page 9
97580531.xlsx
XXXX XXXX
CV-XXX CV-XXX
48 48
45 45
5 5
1 1
XXXX
CV-XXX
48
45
Page 10
97580531.xlsx
Valve Cf
Check for Critical Flow Condition (cavitation or flashing) Required Turbulent Laminar Cv Cv Cv
del Ps (psi)
Notes
1000 1000
15.64 15.64
3206 3206
0.75 Err:522
Err:522
32.5 32.5
44.35 44.35
Err:522
1000
15.64
3206
32.5
44.35
Page 11
Liquids
Job No. Tag No. Service Flow (gpm) P1 (psia) Delta P (psi)
XXXX
CV-XXX
245.46
404.95
19
Fluid s.g.
Fluid Pv (psia)
Fluid Pc (psia)
Valve Cf
Check for Critical Flow Condition (cavitation or flashing) Flow del Ps Critical? Cv (psi)
Notes
0.5
48
615.76
0.75
NO
39.8
407.74