AS-INTERFACE OVERVIEW
AS-Interface has established itself as the global standard in cost-effective transmission of standard and safe components using only one cable for power and communication.
ADVANTAGES OF AS-INTERFACE
s Free choice of topology s Works with all fieldbusses s Simple installation using a redundant piercing connection technology s Reverse-polarity protected flat cable s Distributed solutions s Transmission of safe input and output signals s Simple extension, flexible adaptation s Automatic addressing after device exchanges s Monitoring of sensor failures, cable breaks and short-circuits s High noise immunity enables secure data transfer on unshielded flat cable s Diagnostic functions using display on master and local display via LED on modules s Statistical evaluation of transmission errors
AS-INTERFACE IS SAFE
Safety systems can be used with devices in safety applications up to Category 4 (according to EN 954-1) or SIL3 (according to IEC 61508). Safe signals can be transmitted on the same flat cable, which reduces cabling costs. Safety PLCs cards are completely unnecessary. A safety monitor listens to the communication on the AS-Interface network and constantly evaluates the data from the safety devices. Groupings and logic combinations can be configured in a Windows-based software package.
AS-Interface scanner with serial RS232 connection or gateways to all popular fieldbusses can bring all information into the control system. When AS-Interface is integrated into a running system, existing programs in the PC or PLC can still be used, since the AS-Interface behaves like an I/O card. The scanners and gateways control and monitor data exchange with the modules and AS-Interface sensors/ actuators utilizing the Master-Slave principle. From the viewpoint of the upper level network, however, the gateway behaves like a slave with more than 32 bytes of input/output data as well as additional analog channels and management channels.
G4 DESIGN IN IP67
Scanner/gateways are available as PC cards, as control cabinet devices, and as field devices. With scanner/ gateways, configuration errors, peripheral errors, communication errors, duplicate addresses and ground faults are securely diagnosed. All diagnostic information of the safety monitor is transmitted to a higher level network. Using the integrated safety monitor with PROFIBUS-gateway, all safety-related diagnostics can also be read off the gateway locally, in plain text. s H x W x D: 70 x 90 x 100 mm s Assembly in the field in protection class IP67 s DIN rail or panel mounting s Connection of fieldbus / power via screwed connections and AS-Interface directly via a redundant piercing connection technology
Order code VBG-PB-K20-D VBG-IP-K20-D VBG-EN-K20-D VBG-PN-K20-D VAG-MOD-K20-D VBG-DN-K20-D VBG-PB-G4F-R4 VAG-PB-G4F-R4 VBG-CCL-G4F
Interface PROFIBUS Modbus/TCP EtherNet/IP PROFINET Modbus/RS485 DeviceNet PROFIBUS PROFIBUS CC-Link
Order code VBG-PB-K20-DMD VBG-PB-K20-DMD-BV VBG-PB-K20-DMD-C1* VBG-IP-K20-DMD VBG-EN-K20-DMD VBG-EN-K20-DMD-C1* VBG-PN-K20-DMD VBG-DN-K20-DMD VBG-DN-K20-DMD-BV
Interface PROFIBUS PROFIBUS, basic version PROFIBUS Modbus/TCP EtherNet/IP EtherNet/IP PROFINET DeviceNet DeviceNet, basic version
K20 DESIGN
s H x W x D: 120 x 75 x 80 mm s Single or dual master with gateway function for control cabinet s Large backlit display s Duplicate address detection s Ground fault detection s Stainless steel housing s Removable terminals
K25 DESIGN
s H x W x D: 120 x 45 x 45 mm s Single master with PROFIBUS connection for control cabinet s 7 segment display s Stainless steel housing s Removable terminals
K24
Order code VAN-115/230AC-K17 VAN-115/230AC-K24 VAN-115/230AC-K17-CL2 VAN-115/230AC-K21-EFD VAN-115/230AC-K22-EFD VAN-24DC-K6** 3A K17-STR- K24-STR- VAN-G4-PE-4A VAN-KE2-2PE
Description Overload indicator Overload indicator Class II power supply Ground fault monitoring Ground fault monitoring Input voltage 24 V DC
Output voltage 30.5 V DC (galvanically isolated) 30.5 V DC (galvanically isolated) 30.5 V DC (galvanically isolated) 30.5 V DC (galvanically isolated) 30.5 V DC (galvanically isolated) 30.5 V DC (galvanically isolated)
Power supplies for auxiliary power and AS-i with external decoupling 23 V DC - 32 V DC adjustable Power supplies for auxiliary power and AS-i with external decoupling 23 V DC - 32 V DC adjustable Galvanic isolation input voltage 30 V DC Galvanic isolation input voltage 30 V DC 30.5 V DC (galvanically isolated) 30.5 V DC (galvanically isolated)
REPEATERS
If an AS-Interface network is over 100 m long, it can be extended an additional 100 m using a repeater. Up to two repeaters may be connected in series. In a star configuration, network lengths of 1 km can be implemented. The repeater galvanically isolates the two network segments and transmits the data modulation from one segment to the other. Since repeaters isolate the connected network segments, an AS-Interface power supply or power extender must be located in both segments. This does not affect the maximum number of modules. LEDs on the repeater display operating voltage and any communication error.
POWER EXTENDER
The VAN-G4-PE-4A Power Extender and a DC power supply with 30 V DC can be used instead of an AS-Interface power supply unit. When an AS-Interface power extender is used, the distance between the power supply unit and the power extender is not included in the calculation of the bus length. The combination of power extender, repeater for the field and the IP67 G4 gateway enables a distributed AS-Interface solution, with which no control cabinet is necessary.
G4 KE2
All KE, KE1 and KE2 series modules are only 22.5 mm wide, offer an integrated addressing jack and removable color-coded terminals for simple connection: Yellow = AS-Interface Black = Signals Gray = 24 V DC Red = Relays / 230 V AC/DC All terminal blocks are included in the delivery.
KE1 DESIGN
This flat design is 50 mm high and has 16 terminal connections. It is ideal for compact junction boxes.
KE DESIGN
The KE modules have 24 terminal connections and an installation height of 105 mm.
KE2 DESIGN
This design has 16 terminal connections and is 92 mm high.
Order code VAA-4E4A-KE1-Z/E2 VBA-4E2A-KE1-Z/E2 VBA-4E-KE1-Z VAA-4E4A-KE-ZE/E2 VAA-4E4A-KE-ZE/R VBA-4E3A-KE-ZE/E2 VBA-4E3A-KE-ZE/R VBA-4E4A-KE-ZE/E2 VBA-4E-KE-ZE VBA-2E-KE2-I/U
8
Description Double terminal connection, supply of inputs/outputs from auxiliary power Inputs for 2-wire sensors/pushbuttons only Inputs for 2-wire sensors/pushbuttons only Max 0.7 A output current Max 2 A output current, relay outputs Max 3 A output current Max 2 A output current, relay outputs Max 0.7 A output current
ANALOG MODULES
Analog signals can also be simply and quickly transmitted with AS-Interface. Current values (4 mA 20 mA) and/ or voltage values (0V 10 V) can be transmitted with the 2-channel control cabinet module VAA-2E-KE2-I/U. Signal detection is done by simply wiring to the proper terminals. Resolution is 16 bit and 7 cycles are required per channel for transmission.
Description Supply from AS-i Supply from AS-i, encapsulated, removable screw terminals Supply from AS-i, circuit board, pins Supply from AS-i, circuit board, screw terminals Expoxy ll, removable screw terminals
Three housing designs are available. The G12 flat module offers a connection using M12 connectors, the G4 module offers a cable glands, and the G16 compact module can be connected to sensors using a 3-pin M8 connector.
Order code VBA-4E-G12-ZAJ VBA-4E-G12-ZAL* VBA-4E4A-G12-ZAJ/EA2L VAA-4E4A-G12-ZAJ/EA2L* VAA-4E4A-G12-ZAJ/EA2J VBA-2E2A-G12-ZAJ/EA2L VAA-4A-G12-EA2L VBA-4E4E-G12-ZAJ
* externally supplied from AUX
Encapsulated electronics
Laser marking
One-piece housing Precise alignment No-tool accessible addressing jack Finger recess Stainless steel base Stainless steel mounting bar with positive "click" feedback Integrated stainless steel DIN clip Cable catch simplifies cable placement
AS-INTERFACE G16 COMPACT MODULE WITH 4 inputs in shorter design 4 input and 4 outputs, in longer design 4 inputs and 4 outputs, in longer design
Output-specific diagnostics
11
G4 MODULES
Input connections are made with cable glands and cage-clamp terminals. This allows the input cables to be cut to any length, saving plug connector costs and avoiding metal parts that could corrode. These modules are preferred in process technology and in the food industry because of aggressive cleaning agents. Connection to the AS-Interface is made with flat cable or round cable with screw terminals. The G4 module can be mounted on the DIN rail or can be bolted to the surface. There are also analog value modules for current, voltage or PT100 available in the G4 housing.
Order code VBA-4E-G4-ZE VAA-4E4A-G4-ZE/E2 VBA-2E2A-G4-ZE/E2 VBA-4E3A-G4-ZE/E2 VBA-4E4A-G4-ZE/E2 VBA-4E-G4-PT100 VBA-2E-G4-I VBA-2E-G4-U VBA-2A-G4-I VBA-2E-G4-U
Inputs/outputs 4/ 4/4 2/2 4/3 4/4 4 x analog PT100 / 2 x analog I / 2 x analog V / / 2 x analog I / 2 x analog U
Inputs/outputs 1/3
Description Pneumatic module, 4 inputs/2 outputs, exhaust lter, supplied from AS-i Pneumatic module, 4 inputs/2 outputs, exhaust lter, externally supplied Pneumatic module, 2 outputs, guided exhaust
PNEUMATIC MODULES
Distributed pneumatic modules respond well to the AS-Interface. Shorter air pressure lines reduce energy consumption and improve reaction time. This solution is superior to central valve clusters for air pressure lines that are longer than 2 meters. The module has 2 pneumatic outputs (2 8 bar) for up to two valves and 4 inputs, e.g., for end position detection. Different modules are available for exhaust via sinter filters, for guided exhaust in stainless steel guides and with manual actuation. The modules can be powered by AS-Interface or via auxiliary power.
12
Description For direct mount to actuator 2 x M12 plug connection for AS-i and valve control For direct mount to actuator M12 connection for AS-i, terminal compartment connection for valve control Circuit board with position sensorfor box installation
EX-MODULES IN G5 DESIGN
can be connected to AS-Interface in hazardous areas to zone 1. The Ex-module with ATEX approval is encapsulated (EEx m). Intrinsically safe NAMUR sensors (EEx ia) can be mounted in zone 0 and connected to the G5 module. The AS-Interface connection uses round cable (shifted to increased protection class EEx e), which is introduced using screwed connections. The signals are converted internally to intrinsically safe signals. Up to 4 IEC 60947-5-6-type NAMUR sensors or mechanical contacts can be connected. The outputs can be used to control, intrinsically safe valves.
13
Safe signals can be transmitted via AS-Interface on the same network. Emergency e-stop buttons, safety contacts, door interlocks, key switches, blade switches, and safety light curtains can be connected directly or via safe input modules on AS-Interface. Also motors, brake actuators, fans, etc. can be safely controlled via safe output modules. A safety monitor checks communication and ensures safe power-down to Category 4 according to EN 954-1 or to SIL3 according to IEC 61508. In contrast to solutions based on massive parallel wiring and global AUX power shut-down, Safety at Work is a highly distributed, flexible and easily modified solution. Additionally, this AS-Interface safety concept allows implementing powerful logic conditions and several zones can be remotely switched off via safe output modules if necessary.
14
Logic functions are easily configured on the PC and, with drag-and-drop, they are loaded into the safety monitor. Configurations are easily copied; devices are simple and quick to exchange. All diagnostic data can be transmitted to the controls.
Order code
1 or 2 shut-off circuits, expanded logic function Additionally with control from safe output modules Monitor with plain text display
VAS-2A1L-K31
Graphics display, operating buttons, SD memory card, control from safe outputs, 2 shut-off circuits Additional integrated AS-i master with PROFIBUS interface
VBG-PB-K30-D-S
Order code
VAZ-SW-SIMON
15
s 2 force-controlled contacts s Field-mount or panel mount housing s Self-monitoring via spring preload s Optional integrated illumination
Description Field-mount housing Field-mount housing with illumination Panel mount version 22 mm Panel mount version 22 mm with illumination Emergency shut-off with 2 additional operating buttons Mobile emergency shut-off with enabling switch
STACK LIGHTS
Up to 4 modules can be controlled via the AS-Interface module. s Modular stacking system in IP65 s LEDs with 100,000 hours service life premounted in the lighting module s Acoustical alarm with 85, 105 db (A) s Excellent visibility with 70 mm diameter s Connection via cage-clamp terminals s Also direct parallel wiring without AS-i module possible
Order code VAA-4A-70MM VAZ-LED-70MM-RD VAZ-LED-70MM-YE VAZ-LED-70MM-GN VAZ-LED-70MM-BU VAZ-LED-70MM-CL VAZ-FLASH-70MM-RD VAZ-FLASH-70MM-YE VAZ-HORN-70MM-85dBA
Description AS-Interface trigger module Continuous lamp in red Continuous lamp in yellow Continuous lamp in green Continuous lamp in blue Continuous lamp in clear Flashing lamp in red Flashing lamp in yellow Acoustic alarm 85 dBA
VAZ-HORN-70MM-105dBA Acoustic alarm 105 dBA VAZ-CLAMP-70MM VAZ-CLAMP-70MM-90 VAZ-MH 100-70MM VAZ-MH 90-70MM VAZ-TUBE400-70MM VAZ-TUBE-BASE-70MM VAZ-1/2-Conduit-70MM Clamp connector, straight Clamp connector, angled Base with 100 mm mounting rod Base, angled 90 400 mm mounting rod Fastening base for mounting rods conduit
16
SAFER MODULES
All safe modules are approved by TV according to IEC 61508. Sensors with safety functions, e-stops, position end switches, door interlock switches, or safety light curtains can be connected. For the G12 and KE1 series, the outputs in the module can be logically connected to the inputs via a parameter bit, without the need for programming in the master or PLC. Outputs are safely galvanically isolated from the AS-Interface and protected against overload/short circuits. LED indicators display the status of inputs/ outputs, peripheral errors, operating voltage and any auxiliary power on the modules.
Description 2 safe inputs and 2 standard outputs 2 safe inputs 2 safe inputs for SN sensors Connection of light grids with semiconductor output 2 safe inputs and 2 standard outputs, IP20 2 safe inputs, IP20 Safe output module, relay output, IP20
PLEASE NOTE: Safe modules and emergency shut-off switch each occupy a full address
THE G4 SERIES
s Connection via cord grip
17
ADDRESSING DEVICE
The AS-Interface System is easy to operate with the AS-Interface handheld VBP-HH1-V3.0 or VBP-HH1-V3.0-V1 according to Spec. 3.0. This offers: s Semiautomatic programming s Prevents accidental duplicate addressing s Displays all previously assigned addresses s Can activate switch outputs s Reads safety code sequences from safety modules/ nodes s Enables auxiliary power to be fed to the network s Rechargeable battery and charger are supplied
Description Addressing device for AS-Interface With additional M12 plug for the auxiliary power Programming cable for addressing unit
Order code VAZ-FK-R-YE VAZ-FK-R-BK VAZ-FK-R-YE-1000M VAZ-FK-R-BK-1000M VAZ-FK-S-YE VAZ-FK-S-BK VAZ-FK-S-YE-1000M VAZ-FK-S-BK-1000M VAZ-FK-S-YE-SAFETY VAZ-FK-CL1 VAZ-FK-CL2
Description TPE, yellow, 100 m TPE, black, 100 m TPE, yellow, 1000 m TPE, black, 1000 m Rubber, yellow, 100 m Rubber, black, 100 m Rubber, yellow, 1000 m Rubber, black, 1000 m Rubber, yellow, 100 m, Safety inscription Adhesive holder for a at wire Adhesive holder for 2 at wires (AS-i / AUX)
Order code U-G1FA U-G1FFA U-G1P U-G1PP U-G2FF U-G3FF VAZ-V1-B VAZ-V3-B
Description G1/G4 base, without AUX G1/G4 base, with AUX G1/G4 base, without AUX, round cable G1/G4 base, with AUX, round cable Base for G2 module with 8 slots Base for G2 module with 4 slots M12 Blind plugs M8 Blind plugs
Description 20 End seal with adhesive Cable gland for at cable end
19
Description Suitable for rubber and TPE wires Only suitable for rubber wires
Splitter box, adjustable M20 Integrated ange with at cable exit M12 T-piece, bridged for bus branching
Description Interface adapter RS485/RS232 for PC connection Interface adapter for PROFIBUS Simulator Interface cable for safety monitor to PC AS-i Control Tool Software for diagnosis/conguration Conguration software for AS-i Safety
INDUCTIVE SENSORS
...are available in cylindrical and rectangular designs. s Programmable NO/NC s Pre-fault indication (up to 4 switch points) s Oscillator monitoring
Order code NCB4-12GM60-B3B-V1 NCN4-12GM60-B3B-C2-V1 NCB5-18GM60-B3B-V1 NCN8-18GM60-B3B-V1 The VariKont L series can be installed without tools and has four LED indicators on its four corners for switch status and operating voltage, visible in any direction from a distance. NBB15-30GM60-B3B-V1 NBB6-F-B3B NBB20-L2-B3B-V1 NBN40-L2-B3B-V1 NBB20+U1+B3B NBN30+U1+B3B NBN40+U1+B3B NBB40-FP-B3B-P1 NBB50-FP-B3B-P1 NBN50-FP-B3B-P1
Description Embeddable 4 M12 Non-embeddable 4 M12 Embeddable 5 M18 Non-embeddable 8 M18 Embeddable 15 M30 Embeddable 6 (12 x 30 x 45) mm Embeddable 20 VariKont L Non-embeddable 40 VariKont L Embeddable 20 VariKont Non-embeddable 30 VariKont Non-embeddable 40 VariKont Embeddable 40 FP Embeddable 50 FP Non-embeddable 50 FP
PHOTOELECTRIC SENSORS
Series 28 AS-Interface Intelligent Sensors are the first photoelectric sensors that are compatible with AS-Interface specification 3.0. One of the most important features of this expanded standard is that it can support 62 AS-Interface modules on one bus instead of the previous 31. This makes AS-Interface even more powerful. Every photoelectric sensor can connect directly to the bus, enabling more information, such as status and error messages or commands for parameterization, to be transmitted over the bus. Light on/dark on operation and timer functions can be parameterized online. s Robust, impact resistant plastic housing s Protection class IP67 s Brightly lit display LEDs for Power ON, visible from greater distances s Yellow display LED on the front and rear of the device, so the signal can be read from several directions s Sensitivity adjustment standard s Insensitive to extraneous light, even with flourescent lamps s Simple mounting using dovetailed fastening and pass-through mounting hole
Principle of operation Retroreective sensors Retroreective sensors Retroreective sensors Diffuse mode sensor with background suppression Diffuse mode sensor with background suppression
Description with foreground suppression for safe detection of sheet-shrink-wrapped objects with pole lter for standard applications with laser light for large ranges with visible red light for safe detection of entire surfaces independent of color and structure with visible red light for safe detection of entire surfaces independent of color and structure with laser light for large ranges
RL28-8-H-700-RT-B3B/73c
700 mm
LD28/LV28-LAS-F1-B3B/73c
22
400 m
Regardless of the industry, AS-Interface is always a good alternative to wiring sensors and actuators to higher level controllers such as a PC, PLC, CNC, or DCS.
CHEMICAL
Herberts, a manufacturer, produces industrial lacquers, some of which also contain solvents and are thus categorized as explosion hazardous. The storage tanks are connected with 14 km of pipeline and are controlled over AS-Interface. The open topology enables a system layout that best fits each application, and the AS-Interface gateway to PROFIBUS allows uncomplicated networking.
LOGISTICS
The mail distribution center in Brussels was modernized to achieve higher flexibility and faster processing speed. The solution was AS-Interface. A key aspect for this application was the AS-Interface logic module, which can connect inputs directly to outputs. This improves reaction time and eliminates the need for expensive control circuitry.
MECHANICAL ENGINEERING
Pittl, an automobile transporter in Austria, retooled their modular welding cells with various functions onto AS-Interface and also integrated safety-oriented signals, such as emergency shut-off, over the same flat cable. This saves installation costs and improves process safety.
AUTOMOBILE MANUFACTURE
At OPEL in Rsselsheim, chained assembly lines with over 1 km AS-Interface lines were broken into segments via sliding contacts and connected to AS-Interface. Here, over 1,700 modules with thousands of sensors and 140 masters are proving their reliability every day.
23
Pepperl+Fuchs sets the standard in quality and innovative technology for the world of automation. Our expertise, dedication, and heritage of innovation have driven us to develop the largest and most versatile line of industrial sensor technologies and interface components in the world. With our global presence, reliable service, and flexible production facilities, Pepperl+Fuchs delivers complete solutions for your automation requirements wherever you need us.
Contact Pepperl+Fuchs GmbH Knigsberger Allee 87 68307 Mannheim Germany Tel. +49 621 776-4411 Fax +49 621 776-27-4411 E-mail: fa-info@de.pepperl-fuchs.com
Worldwide Headquarters Pepperl+Fuchs GmbH Mannheim Germany E-mail: info@de.pepperl-fuchs.com USA Headquarters Pepperl+Fuchs Inc. Twinsburg USA E-mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd Singapore Company Registration No. 1999003130E E-mail: sales@sg.pepperl-fuchs.com
www.pepperl-fuchs.com