Xforce Family
Patented Xforce load cells exclusive at Zwick Roell Xforce load cells are only available from Zwick Roell. These high accuracy load cells are used for all Zwick load frames. Applicational range Xforce load cells are ideal for tensile, compression and flexural / bending testing as well as through-zero cyclic testing. Parasitic forces All Xforce load cells are highly insensitivie to parasitic forces (transverse forces, bending moments, torque moments). Construction type and configuration of the load cells All Xforce load cells are based on the rotation-symmetric or axis-symmetric principle and are therefore highly insensitive to transverse forces. The low overall height allows shorter test arrangements to be achieved with, for example, reduced bending issues. The construction type provides a high operating force, very small measurement distances and high stiffness. Simple mechanical pin system All load cells have an accurately fitted play-free connection pin so that grips and test fixtures can be quickly and firmly aligned on the machine test axis. Self identifying sensor plugs The smart load cells have a unique electronic identification system stored on internal EEPROM: testXpert II testing software automatically identifies sensor type and properties no calibration required at sensor change
force and travel limits automatically imported sensor overloads plus date stored in EEPROM Second connection bolt for two test areas Xforce K load cells are the only load cells which can be used for two test areas because of double sided connection studs. Faster load cell changeover by option connection via mounting stud If several load cells are used or if there is to be a frequent changing of load cells, we recommend the option connection via mounting stud. This offers flexibility and significant time savings. The load cell cables will not be strained by screwing/ unscrewing when changing load cells. Reference positions for various test set-ups are automatically achieved (with the threaded mounting the reference position changes depending on the amount of threads used).
PI 716 2.0212
Xforce Xforce HP fulfill all P 5 criterias fulfill all Xforce K from 1% of FN 5 criterias
from 2% of FN 5 criterias from 1% of FN
0.2% 0.4%
Xforce K
Measurement range ISO 7500: Accuracy grade 1 0.2% < 1% ... 100% of FN 1% Accuracy 0.4% Repeatability < 1% Reversibility < 1,5% Zero error < 0,1% ISO 7500: Accuracy grade 1 Resolution < 0,5% Accuracy < 1% Repeatability < 1% Xforce P Fulfill all 5 criterias Reversibility < 1,5% from 0.4% of FN Zero error < 0,1% Resolution < 0,5% Xforce HP Fulfill all 5 criterias Xforce from 0.2% of F criterias Xforce K P Fulfill all 5 N from 0.4% of FN 0.2% Xforce 0.4%
HP Xforce K
Fig. 1 Accuracy grade 1: Xforce HP and XforceMeasurement range K load cells fulfill the 0.2% 0.4% 1% requirements of all five criteria from 0.2% of... 100% of FN the capacity, Xforce P load cells from 0.4% of the capacity. Accuracy grade 0.5: Xforce load cells fulfill the requirements of all five criteria from 1% rsp. 2% of the capacity.
Xforce HP typical accuracy < 0.25% Xforce to from 0.4% of F Linearity according K ISO 7500-1 N Xforce HP typical accuracy < 1% Xforce HP typical accuracy < 0.25% from 0.1% of FN Xforce K from 0.4% of FN Xforce K
0.1% 0.4% Xforce HP Measurement range 1% ... typical accuracy < 1%100% of FN from 0.1% of FN Measurement range ... 100% of FN
Xforce K
0.1% 0.4%
1%
Fig. 2 The linearity error (relative accuracy) is < 0.25% in the range from 0.4 ... 100% of the capacity. The measurement range which achieves a relative accuracy < 1%, typically starts at 0.1% of the rated capacity.
Xforce P Xforce HP (200 N - 250 kN) (200 N - 10 kN) Multiple bending beam 150% of FN 150% of FN 300% of FN 100% of FN 150% of FN 150% of FN 300% of FN 100% of FN 150% of FN 150% of FN 300% of FN 100% of FN
150% of FN 150% of FN 300% of FN 100% of FN 150% of FN 150% of FN 1.000 N (2 200% to 4.000% of FN(2 (200 N) 0.07% of Fact / mm 0.1% of FN / mm +10...+60 C -30...+60 C 0.005% of FN per K 0.005% of FN per K 2mV/V IP 42 3.5 m 2mV/V IP 54 3.5 m 2mV/V IP 54 3.5 m 0.01% of FN per K 0.004% of FN per K 0.01% of FN per K 0.0025% of FN per K 0.2% of FN / mm +10...+60 C -30...+60 C 0.2% of FN / mm +10...+60 C -30...+60 C 0.25% of Fact / mm 0.07% of Fact / mm 0.015% of Fact / mm 0.005% of FN / mm +10...+60 C -30...+60 C 0.001% of FN per K 0.004% of FN per K
0.25% of Fact / mm
0.01% of FN per K
Design Force limits/ranges Operating force Limit force Force at break Limiting transverse load at mounting stud Parasitic influences Influence of bending moment Influence of torque Temperature range Storage temperature Temperature influence on the zero-signal TK0 Temperature influence on the characteristic value TKC Further characteristics Nominal characteristic Protection class Cable length
0.01% of FN per K
2mV/V IP 42 3.5 m
(1
(2
HP/K version recommended for applications in which bending moments or overloads in the tensile/compression direction may occur. Via integrated mechanical support frame.
Explanations regarding parasitic influences and force measurement in general can be found in Application Note AI00108 (Force measurement with Xforce load cells), which we will be happy to make available on request.
Xforce P ( up to 100 N)
Xforce HP
(1
(up to 100 N)
Maximum capacity FN [kN] Maximum capacity FN [lbf] Item number Item number for ProLine (2 Accuracy grade 1 from (0.4% of FN) Accuracy grade 0.5 from (2% of FN) Connection Dia. of mounting stud [mm] Limiting bending moment [Nm] (3 Limiting torque [Nm] 10 2.25 060253 063920 0.04 N 0.2 N M28x1.5 8 1.0 10 20 4.50 060256 063921 0.08 N 0.4 N M28x1.5 8 1.30 10 50 11.24 060257 063922 0.2 N 1N M28x1.5 8 2.0 10
(1
(2
HP version recommended for applications in which bending moments or overloads in the tensile/compression direction may occur. Only in combination with a ProLine load frame; please see note regarding this. (3 Max. bending moments Mb for load cells not loaded in the measurement direction. If the load cell is simultaneously loaded to its nominal load the values must be halved.
20 4496 017907 019242 80 N 400 N flange 1 36 460 (250) 1500 (250) 0.2 45 011571 018548 0.4 N 2N M28x1.5 8 3 (2) 14 (5) 10 2248 325944 20 N 100 N flange 1 20 500 500
30 6744 017908 019246 120 N 600 N flange 1 36 500 (250) 1800 (250)
50 11240 017909 019248 200 N 1000 N flange 1 36 650 (250) 3000 (250)
100 22481 017910 019254 400 N 2000 N flange 2 60 4500 (3500) 10000 (6500) 2.5 562 011568 018545 5N 25 N M28x1.5 20 34 (30) 80 (17)
150 33721 017911 600 N 3000 N flange 2 60 5000 (4000) 12500 (5800)
250 56202 017912 1000 N 5000 N flange 2 60 6000 (5000) 15000 (11000) 10 2248 011565 018543 20 N 100 N M28x1.5 20 115 (80) 200 (17) 250 56202 318930 500 N 2500 N flange 2 60 30000 55000
10 2248 017953 018554 20 N 100 N flange 1 20 115 (80) 200 (17) 150 33721 320304 300 N 1500 N flange 2 60 8000 20000
(5
Note: with Xforce load cells the mounting stud diameter has been changed from 8 to 20 mm for the 1kN load cell! Only in combination with a ProLine load frame; please see note regarding this. (3 The values relating to the limit moments for the connecting system are in brackets. If these are exceeded, re-calibration will be necessary. (4 Max. bending moments Mb for load cells (LC) not loaded in the measurement direction. If the LC is simultaneously loaded to its nominal load the values must be halved. (5 Already included: Option 2. Mounting studs for use of the load cell in two test areas. (6 HP/K version recommended for applications in which bending moments or overloads in the tensile/compression direction may occur.