Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 24

Internal

OptiX Metro 200 Hardware Description


www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

References
OptiX Metro 200 User Manual

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 1

Upon completion this course, you will be able to:


Know the network application of OptiX Metro 200.

Understand the hardware structure and features of OptiX Metro 200.


Understand the functions of normally used units.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 2

Chapter 1 Network Application

Chapter 2 Hardware Structure


Chapter 3 Units Introduction

Chapter 4 Main Features of OptiX Metro 200

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 3

Network Application
Network Application
MSC
E1

OptiX T2000
E1

STM-4 Ring 155622H(Metro1000)

E1

BSC
E1 Ecc

BSC
Ecc E1

STM-1 Ring Metro200


E1 E1

E1

STM-1 Ring
BSC

Metro200
E1 E1 BTS BTS

BTS BTS BTS

BTS

BTS

BTS

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 4

Network Application
Networking
The following network topologies are supported by Metro 200

Link Topology

Ring Topology

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 5

Chapter 1 Network Application

Chapter 2 Hardware Structure


Chapter 3 Unit Introduction

Chapter 4 Main Feature of OptiX Metro 200

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 6

Hardware Structure
System Structure
155Mbit/s VC-4 VC-4 2.048Mbit/s

Line unit
155Mbit/s VC-4

VC-4 crossconnect matrix


VC-4

Tributary unit
2.048Mbit/s

Asynchronous transparent data

Order wire unit

Timing unit

Main contr ol unit

NM system

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 7

Hardware Structure
Interfaces

OptiX Metro 200


1. Grounding Terminal 6. Boolean Value Interface 11. NM Interface 2. Indicators 3. Optical Interface 4. Reset Switch 5. Clock Input/Output Interface 10. Indicators for the Optical Interfaces

7. ESD Wrist Strap Jack 12. Transparent Data Interface (F2)

8. -48V Power Unit

9. Power Switch

13. E1 Electrical Interface

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 8

Chapter 1 Network Application

Chapter 2 Hardware Structure


Chapter 3 Units Introduction

Chapter 4 Main Features of OptiX Metro 200

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 9

Units Introduction
Tributary unit
Receive and transmit 8E1(75/120) signals. Provide automatic protection switching. Provide inloop and outloop. Process the VC-12 path overhead (POH) and monitor the path

of each service.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 10

Units Introduction
Line unit
Provide one or two S-1.1 STM-1 optical interfaces. Detect and report various alarm signals and

performance events on the line.


Process high order overhead
Form networks such as chain and ring when working

with cross-connect unit.


Provide inloop and outloop for prompt fault location.. Provide Automatic Laser Shutdown (ALS) function.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 11

Units Introduction
Cross-connect unit
Perform cross connection to the line and line signals, line

and tributary signals, and tributary and tributary signals.


Add/drop the tributary E1 signal and groom VC-4 signals

freely.
Support network topologies such as point-to-point, chain and

ring.
Support configuring Network Element (NE) into Terminal

Multiplexer (TM) or Add/Drop Multiplexer (ADM).

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 12

Units Introduction
Main control & Orderwire unit
Extract/insert, switch and broadcast the overhead bytes, support

point-to-point, point-to-multipoint equipment interconnection.


Transform, process and save the performance data and hardware

alarm events received by the line unit, tributary unit, timing unit, orderwire unit, etc..
Facilitate the SDH NM system in managing NE boards.
Pass the control and management information to upstream or

downstream NEs.
Provide DCC for communication with remote NEs.

Monitor, maintain and manage the equipment in real time.

Access asynchronous serial data.


HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 13

Units Introduction
Timing unit
Provide synchronization clock for the system line unit and

tributary unit.
Lock the line and tributary timing source for system

synchronization.
Provide the system with five timing sources. In maser/slave synchronization mode, the clock of NE node

generally has the following three working modes: Locked mode

Holdover mode
Free-run mode
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14

Chapter 1 Network Application

Chapter 2 Hardware Structure


Chapter 3 Units Introduction

Chapter 4 Main Features of OptiX Metro 200

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 15

Main Features of OptiX Metro 200


Access Capability
OptiX Metro 200 provides service access capabilities listed as

follow:

Service Type STM-1 E1 service 2 8

Maximum Access Capability

64kbit/s service

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 16

Main Features of OptiX Metro 200


Management Mode
OptiX Metro 200 support two different management mode:

OptiX iManager T2000 OptiX iManager T2000 performs operation, administration and maintenance (OAM) over the OptiX Metro 200, realizing service configuration and allocation, and ensuring reliable running of the network. Web-LCT In the terminal computer with an Explorer of Release 5.0 or above, input the IP address, you can configure services or query alarms of the OptiX Metro 200, as well as other NMS operations.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17

Main Features of OptiX Metro 200


Network Protection

Path Protection

Two-fiber unidirectional path protection ring Two-fiber bidirectional path protection ring

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 18

Main Features of OptiX Metro 200


Power Supply Protection
-48V DC:

It provides two DC power supply ports, backing up each other. Monitor the input voltage and generate alarms for over-voltage or under-voltage.
220V AC:

Two internal power modules back up each other. Provide alarms upon power module failure.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 19

Main Features of OptiX Metro 200


Service auto-configuration
Services will be automatically configured once the NE is powered on;
Single optical interface:

configure the 1 ~ 8 tributary E1 services to the 1 ~ 8 STM-1 timeslots, bidirectional;


Dual optical interfaces:

configure the 1 ~ 8 tributary E1 services to the 1 ~ 8 STM-1 timeslots, unidirectional PP protected.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 20

Main Features of OptiX Metro 200


Installation
On the wall; In the 19-inch cabinet; In the 300mm-deep ETS cabinet; In the 600mm-deep ETS cabinet.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 21

Summary

Network Application Hardware Structure Units Introduction Main Features of OptiX Metro 200

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 22

Thank You
www.huawei.com