Professional Documents
Culture Documents
OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
References
OptiX Metro 200 User Manual
Page 1
Page 2
Page 3
Network Application
Network Application
MSC
E1
OptiX T2000
E1
E1
BSC
E1 Ecc
BSC
Ecc E1
E1
STM-1 Ring
BSC
Metro200
E1 E1 BTS BTS
BTS
BTS
BTS
Page 4
Network Application
Networking
The following network topologies are supported by Metro 200
Link Topology
Ring Topology
Page 5
Page 6
Hardware Structure
System Structure
155Mbit/s VC-4 VC-4 2.048Mbit/s
Line unit
155Mbit/s VC-4
Tributary unit
2.048Mbit/s
Timing unit
NM system
Page 7
Hardware Structure
Interfaces
9. Power Switch
Page 8
Page 9
Units Introduction
Tributary unit
Receive and transmit 8E1(75/120) signals. Provide automatic protection switching. Provide inloop and outloop. Process the VC-12 path overhead (POH) and monitor the path
of each service.
Page 10
Units Introduction
Line unit
Provide one or two S-1.1 STM-1 optical interfaces. Detect and report various alarm signals and
Page 11
Units Introduction
Cross-connect unit
Perform cross connection to the line and line signals, line
freely.
Support network topologies such as point-to-point, chain and
ring.
Support configuring Network Element (NE) into Terminal
Page 12
Units Introduction
Main control & Orderwire unit
Extract/insert, switch and broadcast the overhead bytes, support
alarm events received by the line unit, tributary unit, timing unit, orderwire unit, etc..
Facilitate the SDH NM system in managing NE boards.
Pass the control and management information to upstream or
downstream NEs.
Provide DCC for communication with remote NEs.
Units Introduction
Timing unit
Provide synchronization clock for the system line unit and
tributary unit.
Lock the line and tributary timing source for system
synchronization.
Provide the system with five timing sources. In maser/slave synchronization mode, the clock of NE node
Holdover mode
Free-run mode
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14
Page 15
follow:
64kbit/s service
Page 16
OptiX iManager T2000 OptiX iManager T2000 performs operation, administration and maintenance (OAM) over the OptiX Metro 200, realizing service configuration and allocation, and ensuring reliable running of the network. Web-LCT In the terminal computer with an Explorer of Release 5.0 or above, input the IP address, you can configure services or query alarms of the OptiX Metro 200, as well as other NMS operations.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17
Path Protection
Two-fiber unidirectional path protection ring Two-fiber bidirectional path protection ring
Page 18
It provides two DC power supply ports, backing up each other. Monitor the input voltage and generate alarms for over-voltage or under-voltage.
220V AC:
Two internal power modules back up each other. Provide alarms upon power module failure.
Page 19
Page 20
Page 21
Summary
Network Application Hardware Structure Units Introduction Main Features of OptiX Metro 200
Page 22
Thank You
www.huawei.com