Indoor and outdoor installations for: Offshore oil & gas exploration and production Fence line emission monitoring at industrial sites Petrochemical storage areas LNG/LPG storage, pumping, and filling Pipelines Paint booths and paint production Bus terminals [natural gas powered vehicles]
MSA 2008
MSA 2008
MSA 2008
New Features
Advanced Xenon Flash source
Improved, low-profile stainless steel housings w/swivel mounts Heated detector and source optics
MSA 2008
New Features
Explosion-proof enclosure Data port (I.S. approved)
Heated optics
Small (robust) footprint swivel mount
MSA 2008
mounting plate
MSA 2008
shoulder strap
PDA charger
MSA 2008
New Features
3mA: maintenance call early warning of preventative maintenance Programmable configuration and diagnostics via hand-held unit 3 year system warranty, 10-year lamp warranty
MSA 2008
Product Features
High sensitivity and fast response to hydrocarbon gases
Detection range up to 120 meters
MSA 2008
Product Features
Alignment Kit
Allen wrenches
MSA 2008
Product Features
Gases detected: simultaneous detection of flammable gases C1-C8
Models
MSA 2008
Product Features
Dual-spectrum reference sensor, triple optics detector
Immune
radiation Continuous operation in extreme environmental conditions Operational integrity with up to 90% reduction in signal
MSA 2008
MSA 2008
Specification
Sensitivity Range: 0 - 5 LEL. m (optional 0-2 LEL. m)
Displacement/Misalignment tolerance to fault : 1
MSA 2008
Specification
Warranty:
3 years for the complete system 10 years for Xenon Flash Lamp Explosion proof: Class I, Div. I, Groups A-D, Class I, Div. 2, Groups A-D
MSA 2008
Electrical Specification
Power supply: 24 VDC nominal (18 - 32 VDC)
Power consumption: Detector: 150mA @ 24 VDC Source: 100mA @ 24 VDC (detector/source 300mA peak includes heated optics) Electrical connection: 2 x M25 x 1.5mm or 2 x 14 NPT
MSA 2008
4- 20 mA Output Signals
4mA: Zero
3mA: Maintenance call: early warning of preventative maintenance
0mA: Fault
MSA 2008
Maintenance Call
Maintenance Call provides a 3mA output as a pre-warning maintenance signal. The SafEye Xenon 800 Detector continues to function in this mode.
MSA 2008
Communication Features
RS-485 Modbus RTU communication
Data communication with a host computer or universal controller
MSA 2008
MSA 2008
MSA 2008
MSA 2008
Detector status Change setup Current gas reading Detector serial number Address (if networked) Many other diagnostic features
MSA 2008
MSA 2008
MSA 2008
MSA 2008
The New SafEye Xenon 800 Open Path Gas Detection System