HDLBusPro English Webinar
HDLBusPro English Webinar
HDLBusPro English Webinar
DLP programming
8 in 1 programming 4z, switch, Logic programming Dimmer, relays programming
About iRidium mobile GUI editor overview Advantages vs other systems Main functions and graphical capabilities New functions in latest versions
Licensing system Touch GUI programming Transfer to iPad/Android etc. Test Demo project Get free license, unlimited trial licensing etc.
October 14
October 18
Available online
October 25
|
About company
About HDL
About HDL
Connections
The standard International communication Language & Protocol, it is short for Transfer Control Protocol/Internet Protocol.
Transport
RS485
RS 485 is commonly used in Data Communication , Computer Network, and also the Distributed Industry Control system, for the data converter and transmission.
Transport
DMX512
DMX is short for Digital Multiplex512 means there are maximum 512 bytes of Control Signal in the DMX512 cables at one time. The Protocol was made by Technology Association of American drama in 1986. It was mainly used for the communication between console and Dimmer but now the DMX512 Protocol is expanded to other device, such as color changer, computer lights, Smoker Generator and so on.
DALI is short for ----Digital Addressable Lighting Interface. It defines the communication protocol between ballast s and controller. Those DALI ballasts use Lower Voltage cable as the Lighting control signal bus. All ballast s on bus can be assigned an address automatically, so the fluorescent light can be control led separately or by random group control
KNX
OPC is short for ---OLE for Process Control. It is an industry process control standard. Before the birth of OPC , there is no unified standard interface between hardware driver and application software. OPC aims to provide an standard interface for communication between different devices and software from different companies.
LonWorks (local operation network) is a networking platform specifically created to address the needs of control applications. The platform is built on a protocol created by Echelon Corporation for networking devices over media such as twisted pair, powerlines, fiber optics, and RF. It is used for the automation of various functions within buildings such as lighting and HVAC; see building automation.
ModBus
Modbus is a serial communications protocol originally published by Modicon (now Schneider Electric) in 1979 for use with its programmable logic controllers (PLCs). Simple and robust, it has since become a de facto standard communication protocol, and it is now a commonly available means of connecting industrial electronic devices.
AC220V
Other Sunbet
Programming Module/Converter
Dimming Module
Relay Module
LCD Panel
6-Gang Switch
PC RS485
Network topology
YES
NO
If bigger networks
Limitations / Recommendations
1200m (recommend 1000m) of cable inside one
network
64 devices in one network (if cable < 500m) 32 devices in one network (if cable is 500-1000m)
Connectors
Old connector
New connector
Power
750mA Power Supply 2.4A Power Supply 24V by default Keep more than 15V per device with voltage drop in mind How much mA each device consumes? See Catalogue (20-40mA usually)
Simple inputs
Switches and sensors
Key switch
1-gang US box 1-gang US box 1-gang US box
Euro backbox (square or round) US bachbox (1gang) Slim by special order (special box)
8 buttons
6 buttons
Rouund box
Square box
8 separate buttons Round box Firmware update over bus New bus and power connector
Paper icons Round box Firmware update over bus New bus and power connector
Touch surface Round box Firmware update over bus New bus and power connector
Back boxes
EU Round Box MAIN! (can fit square box also) EU Square Box US 1-gang Box HDL special boxes
Bus sensors
Movement sensors 8 in 1 12 in 1
Movement sensors
Movement PIR
Light Level
IR in IR out Dry IN x 2
Logic functions
Security functions
Dry inputs
SB-DN-DRY-24Z SB-DRY-4Z
MSD08.40 MSD04.40
By using these devices you can connect mechanical switches to the system
Variable inputs
Sensors
Temperature
DLP, 12 in 1, air sensors 4ch sensor input 6ch HVAC controller
Temperature sensors available in many HDL devices Used to air temperature detection
Used mostly for warm floor temperature detection Can be used to detect outside temp (down to -20)
Used mostly for warm floor control and temperature detection Up to 8 sensors for one module HDL 1-Wire digital sensors used
Power metering
3 phase x 1 channel 1 phase x 3 channel Use with 50A, 100A or 200A transformers Built-in logic If power . Than . Monitor power from software
IR inputs
Inbuilt
NEW ONE
Wireless receivers
Commands, issued IR
are stored in the device
TCP/IP interface
TCP/IP interface
TCP/IP interface
RS232 interface
Transparent mode
NUVO control mode Custom string control mode (99 in, 99 out)
HEX
ASCII
Integration bridge
KNX Gateway
2-way interface
between HDL Bus and KNX
DMX Gateway
Control DMX512 protocol commands Mostly for LED and RGB LED control Include TCP/IP interface 48 channel 512 channel DMX Recorder
650mA/ch 3A/ch
DALI Gateway
Control 64 DALI ballasts Mostly used for fluorescent lights control Includes DALI power supply HDL also produces DALI electronic ballasts
SMS Gateway
Online controller
Raspberry Home Online Controller Browser HTML5 control of HDL Bus Pro. Internet or LAN Easy configuration (scan HDL devices, web interface) Any platform: iOS, Android, Windows, MacOS etc.
Relay Outputs
ON/OFF control
Relays
10 Amp
HVAC controller
Motor relay
2 motors 220V control 1 motor 24V control May be other options UV switch 1 and 2 makes it:
FWD STOP REV
STOP
% percentage
control
Variable Outputs
Dimmers etc.
Dimmers DIN
Trailing Edge 1A 6A Leading Edge 2A 6A Leading edge is cheaper, more power Trailing edge is better dimming. But eye can hardly tell usually, for most types of lamps Also TE better protected from short cirquit and overheating
SB-DN-D0206 SB-DN-D0403 SB-DN-D0602 HDL-MD0206.432 HDL-MD0403.432 HDL-MD0602.432 SB-DN-DT0106 SB-DN-DT0203 SB-DN-DT0402 SB-DN-DT0601 HDL-MDT0204.433 HDL-MDT0403.433 HDL-MDT0602.433
Dimmers Wall
Controls lighting
ballasts
0-10V device
HDL also
produces 0-10V ballast
Can be controlled
directly via UV Switches
Infrared Outputs
AC and AV control
255 IR address signals memory Real capacity depends on how long signal is, can be 30-50 signals or more Control ACs, TVs etc. Learn new IR signals using IR reader (USB to PC)
Logic controller
Clock, calendar and
timer functions
Security controller
8 security areas Many sensors are monitored in each area
Z-Audio
IN:
Audio IN
iLife
Preconfigured GUI
software
iRidium Mobile
Worlds most functional smart home software Great HDL Bus compatibility
LAN Or internet
Examples
Control for different systems
Lighting
Climate
Security
Media
THANK YOU!
www.hdlchina.com