Professional Documents
Culture Documents
The Direct Methanol Fuel Cell
The Direct Methanol Fuel Cell
The Direct Methanol Fuel Cell
DMFC (1)
DMFC (2)
DMFC (3)
In the DMFC Methanol is oxidized directly at the anode (as opposed to H2 as in the PEMFC). High energy density. Liquid CH3OH is preferred over vapour due to the simplicity of design offered; existing liquid fuel distribution network. CH3OH is considered by some of have lower market entry barriers than H2 (eg. less explosive). Cheap and easy to manufacture. Low temperature operation N2 does not burn so no NOx.
DMFC (5)
Cell Reactions Anode: CH3OH(l) + H2O 6e- + 6H+ + CO2(g) PtRu catalyst E0 = 0.046V
E0 = 1.23V
xx
CHOH
xxx
COH
CO
HCOOH
COOH
CO2 The mechanism of methanol electro-oxidation at Pt. From V. S. Bagotzky, Yu. B. Vassilyev and O. A. Khazova, J. Electroanal. Chem., 81 (1977) 229.
DMFC (7)
DMFCs are usually based on porous carbon electrodes and the construction of the fuel cells is very similar to that of the PEMFC, differing primarily in the pattern and depth of the flow channels of the bipolar plates.
DMFC (8)
FlowField
The structure of Gas Diffusion Electrodes (GDEs) (Porous carbon area up to 1000 m2 g-1)
DMFC (9)
Schematic of an experimental vapour-fed single cell DMFC showing the component parts.
DMFC (10)
Cell voltage /V
0.2 0.0
50
250
Typical good polarisation curves for DMFC and PEMFC operating with ambient air at 60 C & 90 C, respectively.
DMFC (11)
The Polymer Electrolyte Membrane employed (Nafion) is permeable to methanol. Methanol reacts at cathode (as well as O2) lowering the cathode potential and hence the cell voltage- BIG problem. Also swells Nafion. Consequently, major research effort on methanol-tolerant cathode catalysts for the DMFC.
11
DMFC (12)
Catalysts for Oxygen Reduction (Cathode) Ruthenium-based chalcogenides (RhRuxSy , RuSe, etc)
12
DMFC (13)
In Newcastle:
13
DMFC (14)
DMFC (15)
4M
RhRu5.9S4.7 2M & 4M methanol, 0.75 mg cm-2 2M
Effect of anode methanol feed concentration and cathode loading on the performance of a liquid-feed DMFC operating at 90C with ambient pressure oxygen. All anodes: PtRu (1:1); 2 mg Pt cm2 (60 wt % on Vulcan XC-72R).
15
DMFC (16)
-2
50 40 30 20 10 0 0
Pt, (Atm. O2) 0.1 barg O2
0.5 barg O2
Rh2Ru11.8S9.4
400
Effect of oxidant pressure on the power characteristics of a liquid-feed DMFC operating at 90 C with 4 M methanol feed. Anode E-TEK PtRu, 60 w/o on XC-72, 2 mg cm-2 Pt. Cathode = 1.5 mg cm-2 Rh2Ru11.8S9.4, 60 w/o Ketjen 600 or 0.75 mg cm-2 Pt, 60 w/o XC16 72.
DMFC (17)
17
DMFC (18)
GCD Chromatograph (Pye Unicam) incorporating a flame ionizer detector and a Shimadzu Chromatopac C-E1B integrator.
Analysis was carried out on exhausts sampled from both Pt and sulfide cathode-based MEAs over a range of cell operating and polarization conditions. Each sample was mixed with a 2% n-propan-1-ol internal standard in order to normalize the signals, and then compared with a curve obtained from a range of methanol standards.
18
DMFC (19)
4M MeOH MoV
2M MeOH ReV
2M MeOH MoV
Pt
Effect of current density and anode methanol feed concentration on the concentration of methanol in the cathode exhausts of: MEA-Pt (, 2 M; , 4 M); MEA-MoV (, 2 M; , 4 M); MEA-ReV (*, 2 M). Cell operated with ambient pressure oxygen.
19
DMFC (20)
DMFC problems 60 100 C = Low temperature- poor kinetics at anode and cathode-much lower power density than H2/O2. Needs Ru co-catalyst- Pt poisons otherwise. Methanol cross over through membrane to cathode, Pt active for methanol oxidation, hence mixed potential. Durability: membrane, agglomeration of Pt
Ballard Power Systems, Inc.: Canada based, global leader in PEM (proton exchange membrane) fuel cell technology. Back up power, Distributed Generation, Vehicles (bus, material handling trucks) http://www.ballard.com/files/PDF/ProductPortfolio.pdf Intelligent Energy: UK based, H2 fuel cells. Aerospace, Military, Motive systems. http://www.intelligent-energy.com/
2011 buses running on route RV1 between Covent Garden and Tower Gateway Station, London
Portable applications
portable appliances and power tools small personal vehicles Consumer electronics like laptops, mobile phones Backup power
Fujitsu fuel cell powered laptop. The methanol powered laptop has a battery life of 8 to 10 hours